File name: Pandora61s1_AldineTX_20220824_L2Fit_fsus1c1d20210909p1-8.txt File generation date: 20260321T201022.0Z Data description: Level 2 spectral fitting results file Data file version: fsus1c1p1-8 Local principal investigator: James Flynn Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 61 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora61_OF_v5d20210204.txt Instrument calibration file used: Pandora61s1_CF_v1d20210909.txt Level 1 file used: Pandora61s1_AldineTX_20220824_L1_smca1c1d20210909p1-8.txt.bz2 Full location name: University Of Houston Trailer Short location name: AldineTX Country of location: United States Location latitude [deg]: 29.9011 Location longitude [deg]: -95.3262 Location altitude [m]: 8 Local noon date: 20220824 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 267 412 Nominal wavelengths inside fitting window [nm]: 306.0766 306.2175 306.3584 306.4992 306.6400 306.7809 306.9217 307.0625 307.2032 307.3440 307.4848 307.6255 307.7662 307.9070 308.0477 308.1884 308.3290 308.4697 308.6103 308.7510 308.8916 309.0322 309.1728 309.3134 309.4540 309.5946 309.7351 309.8756 310.0162 310.1567 310.2972 310.4377 310.5781 310.7186 310.8591 310.9995 311.1399 311.2803 311.4207 311.5611 311.7015 311.8418 311.9822 312.1225 312.2628 312.4031 312.5434 312.6837 312.8240 312.9643 313.1045 313.2447 313.3849 313.5252 313.6654 313.8055 313.9457 314.0859 314.2260 314.3661 314.5062 314.6464 314.7864 314.9265 315.0666 315.2066 315.3467 315.4867 315.6267 315.7667 315.9067 316.0467 316.1867 316.3266 316.4666 316.6065 316.7464 316.8863 317.0262 317.1661 317.3060 317.4458 317.5856 317.7255 317.8653 318.0051 318.1449 318.2847 318.4244 318.5642 318.7039 318.8436 318.9834 319.1231 319.2628 319.4024 319.5421 319.6817 319.8214 319.9610 320.1006 320.2402 320.3798 320.5194 320.6590 320.7985 320.9381 321.0776 321.2171 321.3566 321.4961 321.6356 321.7750 321.9145 322.0539 322.1934 322.3328 322.4722 322.6116 322.7509 322.8903 323.0297 323.1690 323.3083 323.4477 323.5870 323.7262 323.8655 324.0048 324.1440 324.2833 324.4225 324.5617 324.7009 324.8401 324.9793 325.1185 325.2576 325.3968 325.5359 325.6750 325.8141 325.9532 326.0923 326.2314 326.3704 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220824T232927.1Z 8271.978786 5 1 43.38 2 72.97 272.91 88.43 296.09 0.00 1 0.00 1 0 49 1.880e-02 2.263e-03 9.024e-03 1.111e-03 3.272004e-07 4.228585e-07 7.876924e-08 3.784346e-07 8.963163e-06 229.25 -2.00 3.24 -2.00 323.26 0.00e+00 8.265819e-04 1.770613e-04 4.285971e-05 4.342912e-05 2.338140e-03 294.35 -2.00 20.00 -2.00 323.76 0.00e+00 2.634355e-04 2.213128e-04 1.423310e-05 2.557020e-05 4.062203e-03 294.35 -2.00 20.00 -2.00 322.78 0.00e+00 -1.031328e-03 4.822856e-04 5.693197e-05 2.661037e-05 4.364357e-03 294.35 -2.00 20.00 -2.00 323.10 0.00e+00 4.227286e-01 2.462290e-03 1.455650e-04 6.423127e-03 2.513245e-02 239.55 1.36 0.00 1.01 42.18 320.93 0.00e+00 -6.354727e-04 2.252383e-04 3.831159e-05 5.757834e-05 6.671678e-04 294.35 -2.00 20.00 -2.00 319.60 0.00e+00 3.362 0.000 303.00 329.40 4 5.8025e-01 5.5964e-03 3.2662e-02 1.9433e-03 7.7888e-02 3.2396e-02 1.0197e-02 3.5695e-03 5.0642e-04 8.3381e-02 -1.4521e-02 5.0096e-03 4.4048e-04 3.8539e-04 4.6126e-02 -6.6518e-03 2.9479e-03 1.0048e-03 2.6406e-04 2.0545e-02 5.4865e-03 1.6066e-03 2.4125e-04 1.0011e-04 1.2867e-02 7.9770e-03 -1.8275e-02 4.4833e-04 1.7728e-04 4.1736e-05 2.5516e-03 -8.0901e-04 3.9348e-05 3.8955e-06 2.2690e-06 6.1667e-04 -1.0698e-02 4.2444e-05 -4.5220e-01 8.1316e-02 1.7768e-03 7.2554e-04 1.1222e+00 12 8 8 10 0 0 5.86 18.98 1.32 -0.01070 -0.01687 1323 525 1 5 0 32.250 22.71 15.00 18.98 39.07 20.4 1055.96 736 2959 -701 1909 -5969 5016 -9766 2600 -10203 2360 -3496 3279 -607 2082 2910 -2414 2728 -4604 3807 -2845 2768 -3503 3568 -2170 1966 2623 1495 1132 -1629 1742 -888 1889 -599 2113 -952 1253 -982 309 -220 499 111 -696 31 -573 762 -463 696 -838 464 171 155 -477 -218 132 -176 502 -128 313 -1168 -402 -757 354 16 521 276 8 -226 -886 -365 -1287 175 -847 845 282 878 82 28 -170 -40 32 -38 262 -198 350 -189 224 -42 627 68 133 -8 36 -60 -362 41 -622 73 -153 120 -150 140 -254 46 -80 9 67 -98 198 -83 217 -143 84 -192 46 118 154 18 65 92 98 191 -207 308 -194 104 -161 -36 -79 -33 42 -76 -26 18 136 19 172 -143 -11 -155 62 -118 2 -6 33 78 1 23 99 -25 69 -235 202 -483 132 -622 139 -227 211 -42 143 201 -180 208 -395 318 -252 227 -294 288 -199 191 277 167 124 -184 208 -114 280 -105 399 -196 261 -211 66 -48 107 24 -153 7 -140 199 -131 207 -265 150 57 51 -156 -71 44 -64 198 -55 135 -491 -162 -307 154 8 278 154 4 -120 -441 -164 -543 72 -378 423 161 557 57 21 -132 -33 28 -34 231 -168 277 -139 155 -29 465 57 125 -9 40 -66 -377 39 -564 67 -153 126 -167 163 -317 57 -106 13 87 -122 251 -100 263 -181 113 -250 61 166 209 24 81 110 113 226 -266 428 -290 148 -238 -56 -130 -57 74 -137 -47 31 228 30 272 -235 -19 -297 128 -266 6 -15 77 185 2 SS 20220824T233440.7Z 8271.982416 8 1 43.03 2 74.10 273.54 89.42 296.69 0.00 1 0.00 1 0 81 1.329e-02 1.639e-03 1.165e-02 1.289e-03 -3.355436e-07 4.946196e-07 1.514681e-08 3.785213e-07 6.358324e-06 229.25 -2.00 3.24 -2.00 323.40 0.00e+00 9.983658e-04 2.083348e-04 2.222712e-05 4.348582e-05 1.687427e-03 294.35 -2.00 20.00 -2.00 323.97 0.00e+00 6.003203e-04 2.621257e-04 9.018125e-06 2.553002e-05 2.852206e-03 294.35 -2.00 20.00 -2.00 322.89 0.00e+00 -1.034683e-03 5.915527e-04 6.353893e-05 2.662456e-05 3.085384e-03 294.35 -2.00 20.00 -2.00 323.24 0.00e+00 4.476245e-01 2.939557e-03 2.002119e-04 6.422715e-03 1.773920e-02 236.56 1.51 0.00 0.95 29.37 321.19 0.00e+00 -2.772717e-04 2.861281e-04 6.320459e-05 5.759589e-05 4.750464e-04 294.35 -2.00 20.00 -2.00 319.88 0.00e+00 3.585 0.001 303.00 329.40 4 6.2280e-01 6.3365e-03 3.4839e-02 1.9448e-03 5.4711e-02 2.3754e-02 1.2110e-02 3.8131e-03 5.0733e-04 5.8632e-02 -5.0848e-03 5.9267e-03 5.0369e-04 4.0564e-04 3.2983e-02 -1.9095e-02 3.5969e-03 3.0311e-04 3.0221e-04 1.5902e-02 1.1066e-02 1.9770e-03 1.1439e-04 1.1058e-04 9.1625e-03 6.0944e-03 -2.1655e-02 4.0723e-04 7.7885e-05 4.5064e-05 2.1155e-03 -9.6915e-04 4.6758e-05 3.4156e-06 2.2236e-06 4.3595e-04 -1.1086e-02 4.4108e-05 -4.0464e-01 9.0940e-02 1.1200e-03 7.2529e-04 7.9532e-01 12 8 8 10 0 0 31.47 19.02 1.34 -0.01109 -0.01848 1093 434 1 5 0 39.110 22.80 15.00 19.02 39.27 20.1 1055.55 314 -1736 278 -4869 599 5082 1009 -2297 6304 -5898 947 -4491 437 924 1239 -1324 -1867 -1043 -596 2321 -97 3697 -1039 1987 -3091 4032 -782 1698 -200 -859 653 -623 1133 -477 1398 28 -426 -436 344 -827 209 -137 107 692 176 813 -101 418 164 186 -559 -76 -550 -379 -226 -400 76 -589 -471 -657 89 109 573 335 467 -281 -373 -458 -719 -658 33 124 71 635 235 245 -225 147 17 98 193 -109 85 -116 161 -161 245 315 382 95 149 94 -25 -313 -251 -312 -329 -84 -42 33 -38 45 -137 30 -76 23 56 94 74 -142 -7 -177 41 28 207 132 34 28 -59 79 -53 68 138 -1 -4 -75 -246 -95 -70 152 -55 19 125 -25 195 98 -79 -73 -23 -72 17 -90 37 5 111 -60 9 -55 9 -166 21 186 41 -106 301 -322 52 -266 26 56 76 -85 -128 -75 -45 171 -7 258 -77 155 -277 373 -79 165 -20 -93 73 -83 172 -81 246 5 -80 -83 66 -160 40 -27 22 150 42 206 -28 118 48 56 -170 -23 -163 -116 -74 -145 30 -237 -183 -247 34 45 262 168 244 -147 -187 -213 -304 -259 13 52 34 344 143 161 -157 109 13 81 163 -92 68 -88 113 -107 163 227 309 86 151 102 -27 -319 -234 -275 -298 -82 -43 35 -44 54 -166 38 -101 30 69 119 89 -172 -8 -238 53 36 287 177 44 35 -70 90 -63 88 192 -2 -6 -112 -385 -158 -123 270 -100 35 221 -43 316 156 -130 -129 -45 -151 38 -218 93 13 269 -146 SS 20220824T233955.0Z 8271.986053 11 1 42.95 2 75.23 274.17 90.40 297.31 0.00 1 0.00 1 7 263 3.785e-02 2.250e-03 1.633e-02 1.598e-03 5.472260e-07 6.208194e-07 3.392892e-08 3.786277e-07 1.839837e-05 229.25 -2.00 3.24 -2.00 323.57 0.00e+00 1.644586e-04 2.672366e-04 1.755126e-05 4.352556e-05 4.986856e-03 294.35 -2.00 20.00 -2.00 324.25 0.00e+00 2.511990e-04 3.464938e-04 2.748559e-05 2.546724e-05 8.099522e-03 294.35 -2.00 20.00 -2.00 323.05 0.00e+00 -1.132707e-03 8.100205e-04 1.296584e-04 2.701062e-05 8.805993e-03 294.35 -2.00 20.00 -2.00 323.43 0.00e+00 4.910333e-01 3.876588e-03 4.048143e-04 6.422301e-03 5.070872e-02 247.91 1.70 0.00 0.88 22.32 321.51 0.00e+00 1.545487e-04 3.970288e-04 1.683112e-04 5.769063e-05 1.344047e-03 294.35 -2.00 20.00 -2.00 320.23 0.00e+00 3.843 0.001 303.00 329.40 4 6.6855e-01 6.6822e-03 3.7351e-02 1.9466e-03 1.5733e-01 3.8043e-02 1.4999e-02 4.8371e-03 5.2177e-04 1.6759e-01 4.1520e-03 8.1740e-03 1.0369e-03 4.3531e-04 9.7433e-02 -2.2290e-02 6.0783e-03 1.9227e-04 3.4897e-04 4.9955e-02 1.0158e-02 2.8691e-03 1.7875e-04 1.2444e-04 2.5723e-02 4.3143e-03 -3.8685e-02 1.4051e-03 8.8025e-05 4.8951e-05 6.7025e-03 -1.1177e-03 6.3103e-05 4.6739e-06 2.1708e-06 1.2429e-03 -1.1242e-02 3.3518e-05 -8.8639e-01 1.1358e-01 1.9443e-03 7.0314e-04 2.1711e+00 12 10 8 10 0 0 -4.45 19.05 1.32 -0.01124 -0.01977 928 368 1 5 0 46.070 22.90 14.99 19.05 39.34 20.1 1055.80 -19390 -18526 -14244 -15128 -9892 -10283 -13617 -1414 -861 -589 -1643 205 7802 6562 -453 3643 3541 -2762 8978 1310 5012 -11 632 1762 1542 6196 2230 2741 -1644 2060 1103 1028 -337 233 -424 1907 -1906 -317 138 -350 55 141 1151 969 666 393 -225 -129 -139 -275 535 -1017 91 272 358 337 -523 48 -1248 -117 -755 535 -74 409 -346 -612 -327 -458 -171 -620 404 132 432 448 473 -246 -17 -222 28 5 -40 199 -128 320 -56 44 2 577 237 377 -23 -160 -201 -398 -400 -716 -33 403 471 68 100 -265 -158 -175 -6 11 -69 187 185 214 69 67 -133 -58 45 167 241 251 -49 94 -28 -80 82 30 46 -106 15 -169 -59 129 -16 12 22 -179 -34 14 53 19 -113 -37 -141 -14 1 -16 113 60 -528 -533 -418 -458 -307 -349 -521 -56 -37 -27 -79 10 386 335 -24 198 203 -174 545 84 310 -1 41 122 117 497 193 234 -146 192 118 117 -44 33 -65 297 -311 -52 23 -58 9 24 203 184 138 88 -54 -32 -36 -74 142 -270 24 73 104 108 -183 17 -437 -40 -260 198 -31 186 -166 -292 -149 -194 -66 -224 144 51 191 226 267 -151 -11 -154 21 4 -32 157 -97 226 -37 28 2 393 182 326 -23 -166 -208 -388 -356 -604 -29 371 458 70 109 -310 -201 -218 -7 14 -90 230 218 253 86 88 -182 -80 60 218 303 302 -56 105 -32 -101 113 44 71 -171 24 -279 -103 230 -29 23 39 -300 -54 24 86 34 -217 -77 -320 -34 2 -43 299 159 SS 20220824T234509.6Z 8271.989695 14 1 42.86 2 76.37 274.80 91.38 297.93 0.00 1 0.00 1 7 263 8.899e-02 4.943e-03 2.459e-02 2.225e-03 -1.171064e-06 8.736956e-07 5.676290e-07 3.786752e-07 3.990354e-05 229.25 -2.00 3.24 -2.00 323.72 0.00e+00 2.732990e-04 3.794876e-04 1.825912e-04 4.357479e-05 1.100644e-02 294.35 -2.00 20.00 -2.00 324.44 0.00e+00 5.252559e-04 4.979308e-04 1.435446e-04 2.542659e-05 1.900475e-02 294.35 -2.00 20.00 -2.00 323.18 0.00e+00 3.222606e-03 1.169416e-03 7.032251e-04 2.769639e-05 2.065866e-02 294.35 -2.00 20.00 -2.00 323.57 0.00e+00 5.108207e-01 5.603067e-03 2.124034e-03 6.421706e-03 1.191446e-01 243.12 2.38 0.00 0.84 50.45 321.74 0.00e+00 -1.618510e-03 6.002701e-04 8.876606e-04 5.784557e-05 3.116228e-03 294.35 -2.00 20.00 -2.00 320.50 0.00e+00 4.140 0.001 303.00 329.40 4 8.8797e-01 9.4895e-03 4.0343e-02 1.9472e-03 3.6527e-01 -1.8052e-02 2.1752e-02 1.6609e-02 5.5482e-04 3.9242e-01 -9.3121e-03 1.2377e-02 1.3015e-03 4.5019e-04 2.2051e-01 2.7974e-02 9.2464e-03 8.9189e-03 3.4985e-04 8.6004e-02 -1.3216e-02 4.2045e-03 3.1547e-03 1.2266e-04 5.2127e-02 2.5061e-03 -3.4679e-02 2.0306e-03 1.4528e-03 4.4178e-05 7.9095e-03 -1.2197e-03 9.0089e-05 7.2194e-06 2.2406e-06 2.9263e-03 -1.0942e-02 2.5544e-05 -6.0745e-01 1.5114e-01 4.5451e-03 6.8516e-04 4.5544e+00 12 10 8 10 0 0 6.33 19.07 1.36 -0.01094 -0.02025 641 254 1 5 0 66.840 22.90 14.99 19.07 39.36 20.0 1055.57 -31402 -47124 15331 -39663 -6115 -48793 4365 -24732 9457 -7144 12359 1802 -4418 14758 -11192 17611 -7931 5549 -9334 18025 -9651 4720 -7908 -343 6962 6501 8327 207 9868 -2480 11650 -528 8475 1870 6271 484 4236 4077 2595 5475 -1146 598 -1315 3479 -1749 1407 415 1576 46 384 507 -767 2186 -1291 1542 -732 1255 -2003 560 -2184 914 -639 -985 -1111 -1311 -735 -2108 718 -1620 1356 -420 1362 -1167 996 247 -100 -288 -791 261 -403 410 -416 256 -727 231 -550 89 501 559 213 155 176 -313 -308 -1159 -540 -714 863 266 549 103 256 -137 -22 55 -197 321 -78 595 105 411 51 205 -135 122 204 281 368 -195 366 -267 15 -90 59 -210 -279 -166 -108 -39 -6 193 -207 2 -232 268 -300 4 -254 -113 -56 -7 -31 -31 126 44 131 -834 -1440 362 -1254 -171 -1871 139 -1021 349 -307 497 80 -212 644 -580 790 -443 301 -580 942 -592 258 -480 -21 453 463 614 16 719 -213 1026 -54 932 238 814 68 587 570 371 769 -172 91 -212 580 -332 280 89 352 11 93 123 -185 509 -321 403 -215 394 -666 177 -691 286 -221 -385 -475 -587 -325 -904 279 -587 449 -141 491 -494 472 132 -58 -178 -524 181 -296 307 -312 184 -493 145 -331 54 330 415 180 147 178 -317 -294 -1017 -444 -604 772 254 549 109 292 -157 -27 70 -248 385 -96 701 125 508 67 257 -171 164 266 353 442 -225 407 -309 19 -125 88 -303 -421 -263 -182 -70 -11 356 -383 4 -396 435 -481 7 -455 -221 -120 -15 -76 -81 341 119 357 SS 20220824T235538.5Z 8271.996974 17 1 42.87 2 78.63 276.05 93.32 299.21 0.00 1 0.00 1 0 98 1.070e-01 5.627e-03 5.005e-02 4.395e-03 -1.153224e-08 1.775707e-06 1.671225e-06 3.787744e-07 4.727594e-05 229.25 -2.00 3.24 -2.00 324.01 0.00e+00 8.121787e-04 7.854172e-04 4.260322e-04 4.402092e-05 1.413793e-02 294.35 -2.00 20.00 -2.00 324.77 0.00e+00 2.961614e-03 1.028091e-03 6.783473e-04 2.537886e-05 2.381575e-02 294.35 -2.00 20.00 -2.00 323.46 0.00e+00 2.470649e-03 2.519025e-03 1.668885e-03 3.130532e-05 2.481371e-02 294.35 -2.00 20.00 -2.00 323.86 0.00e+00 5.991812e-01 1.200311e-02 4.140017e-03 6.420633e-03 1.437499e-01 238.79 4.62 0.00 0.74 237.53 322.34 0.00e+00 -2.353838e-03 1.429579e-03 3.863277e-03 5.842437e-05 3.757676e-03 294.35 -2.00 20.00 -2.00 321.20 0.00e+00 4.897 0.001 303.00 329.40 4 1.1881e+00 2.5016e-02 4.9631e-02 1.9436e-03 4.3806e-01 8.0824e-03 5.0718e-02 4.8987e-02 6.2310e-04 4.7165e-01 -5.9699e-02 2.4480e-02 3.2556e-03 3.8333e-04 2.8797e-01 8.2966e-02 1.5009e-02 2.2354e-02 2.3037e-04 9.8303e-02 -3.2352e-02 8.1237e-03 7.6704e-03 8.7324e-05 7.0036e-02 8.5220e-04 -3.5655e-02 5.8951e-04 3.5654e-03 1.6073e-05 1.3203e-02 -1.6495e-03 1.8216e-04 3.0820e-05 2.4278e-06 3.5303e-03 -1.0184e-02 -1.4029e-05 -3.3750e-01 2.5990e-01 4.3461e-02 8.5155e-04 4.9204e+00 12 8 8 10 0 0 -13.59 19.08 1.56 -0.01018 -0.02277 328 130 1 5 0 130.670 22.90 15.00 19.08 39.01 20.0 1052.13 -33791 -50490 -58641 37358 -16302 24836 3520 22476 -3476 -13290 4977 -3649 -19174 1847 -11891 -3297 28301 15668 -4190 25495 -7981 -370 -29668 -5314 7897 19310 9141 20570 -532 8597 -10825 4242 12517 8252 7840 148 3730 -2719 1950 -3430 5193 1760 2472 -1680 84 2954 -4352 3318 2201 2872 -2221 2779 319 2602 1076 666 987 689 -446 -3822 650 -758 701 -613 -1127 -1477 1150 -322 105 979 -112 -158 125 173 519 44 -718 -643 -162 -447 -801 -220 -759 -772 -24 -1432 215 -1149 362 -16 366 -324 94 -837 -300 -144 -274 439 -384 757 -477 466 155 217 465 487 51 95 88 -187 388 283 527 -11 700 114 -224 -512 415 -228 81 -215 355 303 -330 -225 -411 -238 -50 70 -113 -99 94 -138 433 -416 21 -211 -137 70 200 -149 -110 112 12 162 -1097 -1724 -2075 1151 -550 807 123 786 -135 -548 199 -153 -870 78 -535 -147 1167 698 -208 1125 -399 -18 -1668 -283 424 1045 540 1139 -33 541 -852 346 1089 804 806 17 413 -318 223 -413 597 214 314 -239 12 432 -725 546 382 510 -413 486 56 464 210 144 233 169 -109 -953 160 -207 213 -207 -398 -520 378 -99 30 259 -30 -47 43 68 230 21 -371 -354 -94 -273 -502 -136 -456 -435 -13 -735 112 -668 236 -12 308 -295 85 -722 -234 -106 -205 347 -323 665 -452 473 174 264 590 616 62 110 98 -210 453 351 678 -15 871 138 -262 -577 445 -239 88 -259 472 440 -509 -364 -705 -435 -95 138 -226 -198 180 -253 748 -708 37 -404 -287 160 459 -371 -290 306 34 452 SS 20220825T001354.4Z 8272.009657 22 1 43.16 2 82.56 278.25 96.64 301.52 0.00 1 0.00 1 0 131 1.272e-01 3.354e-02 1.849e-01 3.040e-02 2.140273e-05 1.295416e-05 2.458563e-06 3.787606e-07 5.603110e-05 229.25 -2.00 3.24 -2.00 324.27 0.00e+00 1.162387e-02 5.920226e-03 1.606504e-03 4.395510e-05 1.524731e-02 294.35 -2.00 20.00 -2.00 325.05 0.00e+00 1.444407e-02 8.154222e-03 5.699830e-04 2.539077e-05 2.716809e-02 294.35 -2.00 20.00 -2.00 323.73 0.00e+00 1.676308e-02 1.934414e-02 2.055915e-03 3.540350e-05 2.951447e-02 294.35 -2.00 20.00 -2.00 324.13 0.00e+00 5.786963e-01 7.167650e-02 9.570213e-03 6.420099e-03 1.727245e-01 166.83 25.28 0.00 0.59 280.45 322.35 0.00e+00 -1.749197e-02 6.712303e-03 1.187251e-03 5.749280e-05 4.466549e-03 294.35 -2.00 20.00 -2.00 321.00 0.00e+00 7.137 0.004 303.00 329.40 4 1.3817e+00 1.9184e-01 6.9823e-02 1.9388e-03 5.2445e-01 9.8437e-01 2.1427e-01 3.1024e-02 6.6411e-04 5.6254e-01 -1.1128e+00 1.1863e-01 2.0423e-02 3.4816e-04 3.0776e-01 4.1210e-01 6.0756e-02 2.1260e-02 1.5081e-04 1.0304e-01 -8.4188e-04 3.5925e-02 3.2791e-03 5.1002e-05 7.3156e-02 5.0907e-05 3.4853e-01 7.9245e-02 1.4303e-03 1.1049e-05 8.2425e-03 -4.6487e-03 1.4280e-03 1.8653e-04 2.7282e-06 4.1684e-03 -7.5002e-03 -1.1294e-04 4.1824e+00 1.3925e+00 6.2551e-02 7.2949e-04 4.2438e+00 12 8 8 10 0 0 29.06 19.07 4.54 -0.00750 -0.04297 50 20 1 5 0 862.930 22.90 15.00 19.07 38.02 20.1 1045.15 -132 -17278 12752 5648 20467 -5433 26203 17031 24715 21178 10796 13392 -5074 20826 -1787 8871 -4510 32125 11622 18227 3597 -21515 -20434 -29697 -3876 -18030 4404 -31368 -16380 -25408 -3494 11823 27775 33569 12678 44440 11994 30443 -8756 15400 -11688 1126 -13568 -5225 -1341 3299 10511 12166 23977 7983 18877 -2627 15266 -11023 -2251 -6914 14076 -466 -549 -1185 -8450 5098 1742 20367 7008 7021 -9188 -1526 -20661 -13081 -21652 -17748 -6253 2119 6895 4072 7331 -1081 15905 -2689 10794 -466 -1142 -6722 -6519 -14589 -17197 -4101 -3051 11716 2649 11931 646 5671 -1760 722 -2349 -2456 994 -3212 2842 -1562 8774 -1278 7257 94 4556 -4127 218 -5662 -2647 -3593 -2258 549 1907 7252 -5091 1343 -4989 3853 -5759 428 -255 -462 -534 -327 1615 -3777 1426 22 1433 -972 1064 -589 3940 -1078 1272 369 -2353 1045 -460 2444 404 -50 -441 -1389 -8 -2533 901 547 1125 -811 1715 1917 2459 2273 1413 1437 -784 1259 -201 743 -673 1850 1430 1732 373 -2929 -2413 -4043 -268 -2440 292 -5091 -1792 -4097 -423 1430 3119 3963 2628 3327 2038 2367 -1815 1463 -2154 143 -2579 -918 -251 637 1937 2347 3659 1770 2990 -582 1846 -2412 -434 -1672 2432 -114 -126 -259 -2141 1116 502 4692 2159 2062 -3254 -409 -6545 -3089 -5736 -4957 -1819 677 2442 1665 2998 -535 6412 -1471 4787 -238 -552 -3213 -2834 -6848 -8815 -2020 -1793 6714 2014 8727 539 4067 -1237 447 -1495 -1641 676 -2507 2251 -1444 7959 -1458 7941 113 4959 -4671 223 -6212 -2889 -4160 -2692 644 2163 7414 -5718 1323 -5186 3583 -6368 491 -333 -677 -844 -542 2767 -7342 2767 45 2910 -2001 2044 -1094 6637 -1875 2195 690 -5054 2415 -1204 6770 1108 -142 -1297 -4160