File name: Pandora207s1_ArlingtonTX_20221203_L2Fit_fnvs5c6d20221007p1-8.txt File generation date: 20240911T083451.5Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c6p1-8 Local principal investigator: Yang Li Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 207 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora207_OF_v5d20210722.txt Instrument calibration file used: Pandora207s1_CF_v6d20221007.txt Level 1 file used: Pandora207s1_ArlingtonTX_20221203_L1_smca1c6d20221007p1-8.txt Full location name: University Of Texas, Arlington Science Hall Short location name: ArlingtonTX Country of location: United States Location latitude [deg]: 32.7316 Location longitude [deg]: -97.1142 Location altitude [m]: 15 Local noon date: 20221203 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 5 "But different Reference day, final winter reference" First and last pixel inside fitting window: 892 1434 Nominal wavelengths inside fitting window [nm]: 400.0476 400.1803 400.3131 400.4459 400.5786 400.7114 400.8441 400.9768 401.1095 401.2421 401.3748 401.5074 401.6401 401.7727 401.9053 402.0379 402.1705 402.3030 402.4356 402.5681 402.7006 402.8331 402.9656 403.0981 403.2306 403.3630 403.4955 403.6279 403.7603 403.8927 404.0251 404.1574 404.2898 404.4221 404.5544 404.6867 404.8190 404.9513 405.0836 405.2158 405.3481 405.4803 405.6125 405.7447 405.8769 406.0090 406.1412 406.2733 406.4055 406.5376 406.6697 406.8018 406.9338 407.0659 407.1979 407.3299 407.4620 407.5940 407.7259 407.8579 407.9899 408.1218 408.2537 408.3856 408.5175 408.6494 408.7813 408.9131 409.0450 409.1768 409.3086 409.4404 409.5722 409.7040 409.8357 409.9675 410.0992 410.2309 410.3626 410.4943 410.6260 410.7576 410.8893 411.0209 411.1525 411.2841 411.4157 411.5473 411.6788 411.8104 411.9419 412.0734 412.2049 412.3364 412.4679 412.5993 412.7308 412.8622 412.9936 413.1250 413.2564 413.3877 413.5191 413.6504 413.7818 413.9131 414.0444 414.1757 414.3069 414.4382 414.5694 414.7007 414.8319 414.9631 415.0943 415.2254 415.3566 415.4877 415.6188 415.7500 415.8811 416.0121 416.1432 416.2743 416.4053 416.5363 416.6673 416.7983 416.9293 417.0603 417.1912 417.3222 417.4531 417.5840 417.7149 417.8458 417.9766 418.1075 418.2383 418.3692 418.5000 418.6308 418.7615 418.8923 419.0231 419.1538 419.2845 419.4152 419.5459 419.6766 419.8073 419.9379 420.0685 420.1992 420.3298 420.4604 420.5909 420.7215 420.8520 420.9826 421.1131 421.2436 421.3741 421.5046 421.6350 421.7655 421.8959 422.0263 422.1567 422.2871 422.4175 422.5478 422.6782 422.8085 422.9388 423.0691 423.1994 423.3297 423.4600 423.5902 423.7204 423.8506 423.9808 424.1110 424.2412 424.3713 424.5015 424.6316 424.7617 424.8918 425.0219 425.1520 425.2820 425.4121 425.5421 425.6721 425.8021 425.9321 426.0620 426.1920 426.3219 426.4518 426.5817 426.7116 426.8415 426.9714 427.1012 427.2311 427.3609 427.4907 427.6205 427.7502 427.8800 428.0097 428.1395 428.2692 428.3989 428.5286 428.6582 428.7879 428.9175 429.0472 429.1768 429.3064 429.4360 429.5655 429.6951 429.8246 429.9541 430.0837 430.2132 430.3426 430.4721 430.6015 430.7310 430.8604 430.9898 431.1192 431.2486 431.3779 431.5073 431.6366 431.7659 431.8952 432.0245 432.1538 432.2831 432.4123 432.5415 432.6707 432.7999 432.9291 433.0583 433.1875 433.3166 433.4457 433.5748 433.7039 433.8330 433.9621 434.0911 434.2202 434.3492 434.4782 434.6072 434.7362 434.8651 434.9941 435.1230 435.2519 435.3808 435.5097 435.6386 435.7674 435.8963 436.0251 436.1539 436.2827 436.4115 436.5403 436.6690 436.7978 436.9265 437.0552 437.1839 437.3126 437.4412 437.5699 437.6985 437.8271 437.9557 438.0843 438.2129 438.3415 438.4700 438.5985 438.7270 438.8555 438.9840 439.1125 439.2410 439.3694 439.4978 439.6262 439.7546 439.8830 440.0114 440.1397 440.2681 440.3964 440.5247 440.6530 440.7812 440.9095 441.0377 441.1660 441.2942 441.4224 441.5506 441.6787 441.8069 441.9350 442.0632 442.1913 442.3194 442.4474 442.5755 442.7035 442.8316 442.9596 443.0876 443.2156 443.3436 443.4715 443.5995 443.7274 443.8553 443.9832 444.1111 444.2390 444.3668 444.4946 444.6225 444.7503 444.8781 445.0058 445.1336 445.2613 445.3891 445.5168 445.6445 445.7722 445.8999 446.0275 446.1551 446.2828 446.4104 446.5380 446.6656 446.7931 446.9207 447.0482 447.1757 447.3032 447.4307 447.5582 447.6856 447.8131 447.9405 448.0679 448.1953 448.3227 448.4501 448.5774 448.7048 448.8321 448.9594 449.0867 449.2139 449.3412 449.4684 449.5957 449.7229 449.8501 449.9773 450.1044 450.2316 450.3587 450.4858 450.6129 450.7400 450.8671 450.9942 451.1212 451.2482 451.3753 451.5023 451.6292 451.7562 451.8832 452.0101 452.1370 452.2639 452.3908 452.5177 452.6446 452.7714 452.8982 453.0250 453.1518 453.2786 453.4054 453.5321 453.6589 453.7856 453.9123 454.0390 454.1657 454.2923 454.4190 454.5456 454.6722 454.7988 454.9254 455.0520 455.1785 455.3050 455.4316 455.5581 455.6846 455.8110 455.9375 456.0639 456.1904 456.3168 456.4432 456.5695 456.6959 456.8223 456.9486 457.0749 457.2012 457.3275 457.4538 457.5800 457.7063 457.8325 457.9587 458.0849 458.2111 458.3372 458.4634 458.5895 458.7156 458.8417 458.9678 459.0939 459.2199 459.3460 459.4720 459.5980 459.7240 459.8500 459.9759 460.1019 460.2278 460.3537 460.4796 460.6055 460.7314 460.8572 460.9830 461.1089 461.2347 461.3604 461.4862 461.6120 461.7377 461.8634 461.9891 462.1148 462.2405 462.3662 462.4918 462.6174 462.7431 462.8687 462.9942 463.1198 463.2454 463.3709 463.4964 463.6219 463.7474 463.8729 463.9983 464.1238 464.2492 464.3746 464.5000 464.6254 464.7507 464.8761 465.0014 465.1267 465.2520 465.3773 465.5026 465.6278 465.7530 465.8783 466.0035 466.1286 466.2538 466.3790 466.5041 466.6292 466.7543 466.8794 467.0045 467.1296 467.2546 467.3796 467.5046 467.6296 467.7546 467.8796 468.0045 468.1294 468.2544 468.3793 468.5041 468.6290 468.7539 468.8787 469.0035 469.1283 469.2531 469.3779 469.5026 469.6274 469.7521 469.8768 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Spectrometer control temperature [°C], 999=no temperature signal Column 159: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 160: Temperature in head sensor [°C], 999=no temperature signal Column 161: Temperature at electronics board 1 [°C], 999=no temperature signal Column 162: Temperature at electronics board 2 [°C], 999=no temperature signal Column 163: Humidity in head sensor [%], -9=no humidity signal Column 164: Pressure in head sensor [hPa], -9=no pressure signal Columns 165-707: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 708-1250: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20221203T133150.1Z 8372.563775 112 1 48.45 2 87.60 118.39 138.63 330.44 0.00 1 0.00 1 7 264 1.557e-02 9.090e-03 6.544e-04 4.379e-04 1.159016e+04 9.464676e+01 7.933113e+02 3.904032e+02 3.187396e+03 285.00 -2.00 20.00 -2.00 453.83 0.00e+00 9.617528e-04 6.140024e-05 5.542113e-05 2.538132e-05 1.706114e-03 285.00 -2.00 20.00 -2.00 460.43 0.00e+00 1.609861e-03 4.177473e-06 1.050575e-05 1.402739e-05 1.428492e-04 225.19 -2.00 2.08 -2.00 449.85 0.00e+00 7.582231e+06 6.540588e+04 1.812476e+05 2.344383e+05 2.292394e+06 265.75 -2.00 10.73 -2.00 462.39 0.00e+00 1.558559e+00 1.003507e-02 1.577798e-02 7.750832e-03 4.859228e-01 224.33 -2.00 3.32 -2.00 459.80 0.00e+00 -9.066314e-05 1.323603e-06 1.485951e-06 1.203773e-06 5.948024e-05 285.00 -2.00 20.00 -2.00 460.08 0.00e+00 14.981 0.047 397.00 473.00 4 2.8682e+00 7.5512e-04 4.0048e-02 3.9646e-04 1.9057e-02 -3.4250e-01 1.0205e-03 8.4272e-03 4.8751e-04 2.7312e-02 1.1656e-01 3.6365e-04 1.1350e-03 1.1752e-04 9.7209e-03 1.0566e-01 1.3463e-04 1.2630e-04 2.7493e-05 3.5732e-03 -8.1488e-02 8.6026e-05 6.5516e-05 2.3298e-05 2.2264e-03 5.4063e-03 -5.3988e-01 5.9170e-04 3.5516e-04 1.6912e-04 1.4172e-02 9.1703e-06 5.6834e-06 2.4905e-06 3.6002e-07 1.6462e-04 1.9176e-04 7.5170e-06 3.1937e-06 4.7853e-07 2.3470e-04 1.0386e-02 -5.4683e-05 8.4732e-01 4.8176e-02 1.6274e-02 5.2967e-03 1.3422e+00 12 10 8 10 0 0 49.12 20.69 1.60 0.01039 -0.00571 282 67 1 2 0 171.190 15.00 20.69 15.21 21.38 21.27 10.2 930.65 819 206 -1456 -2879 -3399 -3580 -1486 307 601 678 178 20 -557 330 -605 441 124 -74 -16 189 60 -1236 -2307 -5277 -6054 -5770 -3615 -1548 222 493 695 -655 -4064 -5399 -6736 -5742 -2832 -759 552 487 -956 -2091 -2367 -2055 -1208 -1797 -1952 -2980 -2445 -2444 -632 581 438 852 374 422 374 478 128 330 1789 2004 2974 2959 3448 3426 4344 4485 4872 4412 4047 3143 2568 2121 555 -937 -2015 -1465 -275 1251 2918 3308 3709 3761 3937 3933 4505 4403 4723 4523 4116 3862 4106 4070 3456 3544 3429 2989 2181 2401 1818 2180 2592 2977 3687 3085 2902 2534 2268 1356 1781 2084 1828 1921 1121 1078 587 612 310 532 518 964 838 672 820 537 170 -81 -87 -187 -325 -913 -864 -400 -720 -776 -998 -843 -1079 -838 -1344 -1241 -905 -1172 -1231 -797 -373 -761 -1139 -1570 -1662 -1905 -1709 -1819 -1618 -1418 -1350 -1055 -1250 -844 -1091 -1174 -1307 -1092 -1183 -1540 -1765 -1815 -1686 -1940 -2227 -2791 -2745 -2429 -2161 -1696 -1456 -1415 -1719 -1708 -1919 -1656 -1438 -995 -991 -1025 -1254 -1421 -1364 -1454 -1404 -1321 -1309 -1500 -1214 -1129 -1473 -1488 -1398 -1079 -1094 -734 -579 -343 -413 -704 -694 -1153 -1144 -1125 -954 -786 -539 -466 -422 -529 -600 -619 -701 -708 -974 -754 -885 -763 -708 -669 -867 -1254 -1438 -2084 -2069 -1991 -2036 -2385 -2362 -2567 -2499 -1725 -974 -526 -479 -403 -379 -187 -187 8 102 51 -141 -124 -164 -482 -85 -136 -24 58 126 120 94 -116 -183 33 137 234 388 63 289 487 392 444 592 569 640 823 872 856 998 920 1028 1079 1133 1289 1234 1449 1492 1783 1902 1958 1972 1758 1799 1966 2248 2320 2312 2012 2177 2116 2180 1993 2051 2000 1829 1658 1554 1543 1536 1696 1667 1804 1660 1754 1436 1170 968 863 973 865 1125 781 511 504 161 196 53 30 -318 -236 -278 -291 -236 -155 34 -95 45 -147 -286 -377 -399 -419 -556 -652 -697 -702 -671 -529 -761 -421 -682 -379 -306 -423 -528 -488 -402 -690 -566 -816 -601 -557 -597 -663 -754 -720 -932 -888 -761 -674 -616 -416 -410 -475 -785 -888 -975 -986 -840 -863 -950 -938 -955 -899 -842 -892 -1022 -932 -804 -822 -881 -786 -675 -643 -533 -391 -372 -329 -233 -232 -172 -138 -168 -189 -46 54 201 434 626 590 513 501 584 633 576 379 120 52 103 69 259 244 471 678 819 848 814 781 689 610 538 434 316 198 120 244 411 509 527 340 276 233 321 390 376 281 229 244 467 647 668 809 766 686 507 270 19 -176 -112 18 120 145 174 189 280 258 237 351 311 310 207 62 -103 -108 -74 3 63 -12 -169 -135 -161 -273 -253 -371 -319 -431 -409 -313 -347 -323 -331 -313 -309 -244 -230 -76 -65 -217 -341 -488 -502 -301 -89 -35 -42 -310 -557 -617 -596 -589 -605 -759 -955 -970 -974 -788 -494 -64 338 535 422 258 12 -168 -231 -290 -210 -152 67 267 275 220 145 112 92 159 297 482 534 545 475 474 532 737 896 323 82 -574 -1131 -1330 -1406 -586 122 240 272 72 8 -224 132 -244 178 50 -30 -6 77 25 -502 -927 -2109 -2401 -2302 -1456 -631 91 203 286 -267 -1635 -2318 -2882 -2467 -1235 -336 245 215 -422 -918 -1034 -899 -529 -787 -849 -1293 -1052 -1060 -278 257 194 379 166 187 165 210 56 147 802 909 1349 1343 1571 1580 2023 2104 2283 2062 1878 1451 1177 959 247 -411 -878 -638 -122 568 1350 1550 1749 1787 1888 1911 2211 2174 2326 2225 2021 1898 2029 2017 1716 1758 1698 1475 1070 1168 886 1069 1292 1515 1906 1607 1499 1292 1148 688 913 1082 959 1009 589 565 307 320 163 283 280 528 465 376 459 300 95 -45 -48 -102 -176 -494 -468 -219 -400 -434 -560 -475 -610 -473 -758 -701 -514 -669 -717 -471 -221 -449 -665 -903 -949 -1085 -981 -1062 -961 -859 -833 -657 -784 -532 -639 -687 -762 -633 -684 -899 -1048 -1087 -1003 -1128 -1241 -1647 -1500 -1364 -1268 -1026 -888 -855 -1026 -1013 -1138 -993 -874 -611 -619 -645 -788 -887 -838 -888 -864 -819 -822 -959 -780 -723 -937 -942 -888 -695 -727 -499 -395 -231 -270 -447 -431 -708 -711 -726 -633 -531 -367 -318 -287 -360 -408 -420 -470 -469 -647 -505 -557 -488 -454 -421 -569 -795 -886 -1267 -1262 -1229 -1257 -1460 -1431 -1553 -1535 -1024 -611 -353 -342 -301 -292 -145 -143 6 71 35 -96 -87 -121 -371 -66 -108 -19 45 96 88 65 -78 -125 23 102 169 287 47 217 360 288 323 435 430 492 639 687 681 805 756 849 890 932 1053 1004 1177 1201 1421 1515 1571 1606 1458 1487 1563 1704 1717 1706 1526 1714 1707 1777 1638 1694 1675 1560 1343 1267 1262 1254 1361 1317 1429 1319 1408 1195 1007 857 773 865 763 985 692 466 468 151 171 48 28 -275 -205 -243 -256 -208 -135 30 -83 40 -133 -262 -345 -361 -378 -504 -599 -650 -661 -631 -499 -715 -388 -619 -339 -271 -378 -476 -444 -373 -653 -545 -800 -591 -548 -591 -627 -726 -704 -924 -887 -755 -658 -591 -417 -412 -460 -784 -902 -992 -998 -848 -873 -965 -961 -985 -935 -887 -951 -1100 -1014 -883 -915 -993 -890 -766 -730 -605 -442 -419 -369 -260 -259 -193 -156 -191 -215 -55 63 232 492 699 660 579 571 669 735 682 460 149 66 131 88 325 307 588 834 1000 1038 1000 965 859 768 686 562 417 266 162 329 547 718 746 486 399 338 467 567 548 413 338 359 675 922 943 1135 1078 975 731 396 28 -264 -167 27 177 215 258 281 417 387 357 530 474 477 323 98 -165 -174 -119 6 101 -19 -275 -221 -264 -450 -420 -619 -535 -724 -686 -524 -582 -543 -555 -526 -520 -409 -386 -127 -109 -368 -584 -841 -860 -509 -149 -59 -71 -537 -982 -1096 -1061 -1052 -1090 -1391 -1672 -1710 -1711 -1365 -887 -112 577 908 724 454 22 -291 -405 -513 -372 -268 117 465 481 390 260 203 167 291 541 877 975 1001 881 883 987 1355 1629 SQ 20221203T134036.6Z 8372.569868 115 1 49.24 2 85.98 119.62 139.43 333.40 0.00 1 0.00 1 0 65 6.551e-03 3.898e-03 3.749e-04 2.601e-04 6.533379e+03 5.635722e+01 4.638513e+02 3.904676e+02 1.341289e+03 285.00 -2.00 20.00 -2.00 452.57 0.00e+00 3.816031e-04 3.430290e-05 1.743456e-05 2.175209e-05 7.058702e-04 285.00 -2.00 20.00 -2.00 459.85 0.00e+00 1.093923e-03 2.434529e-06 7.421936e-06 1.401917e-05 5.959366e-05 225.07 -2.00 2.08 -2.00 448.68 0.00e+00 4.709942e+06 3.819808e+04 8.497646e+04 2.343799e+05 9.573798e+05 265.75 -2.00 10.73 -2.00 461.67 0.00e+00 1.263152e+00 5.962899e-03 8.862709e-03 8.352451e-03 2.039585e-01 224.33 -2.00 3.32 -2.00 459.22 0.00e+00 -2.663936e-05 7.792372e-07 9.133366e-07 1.198076e-06 2.502769e-05 285.00 -2.00 20.00 -2.00 459.55 0.00e+00 11.418 0.021 397.00 473.00 4 2.3840e+00 3.1919e-04 2.9592e-02 4.1472e-04 6.9855e-03 -1.5589e-01 4.4809e-04 6.1890e-03 3.6956e-04 9.7178e-03 7.2230e-02 2.0711e-04 8.2174e-04 1.2024e-04 4.1623e-03 2.5260e-02 9.0408e-05 9.1719e-05 3.3452e-05 1.5954e-03 -3.0962e-02 4.3819e-05 3.0323e-05 1.7786e-05 8.0636e-04 1.3695e-02 -1.6795e-01 1.1801e-04 8.1413e-05 9.0182e-05 4.1594e-03 -2.1937e-06 3.2699e-06 1.3956e-06 3.6221e-07 6.9254e-05 5.3123e-05 4.4795e-06 1.8548e-06 4.4006e-07 9.8726e-05 8.4110e-03 -2.3098e-05 7.0769e-01 2.8312e-02 4.9274e-03 4.0672e-03 5.8152e-01 12 8 8 10 0 0 22.64 20.68 1.06 0.00841 0.00385 568 135 1 2 0 84.590 15.00 20.68 15.68 21.38 21.27 10.0 931.98 -1020 -1012 -1334 -1420 -1751 -1555 -1404 -919 -1012 -1009 -1008 -1083 -1134 -954 -1121 -1139 -1036 -1306 -1159 -1307 -1222 -1214 -1367 -1606 -1500 -1686 -1560 -1206 -1023 -948 -824 -610 -759 -809 -652 -652 -674 -437 -29 -51 -140 -144 34 141 288 312 81 312 482 503 434 666 677 796 766 844 1057 1143 1152 1064 1060 1016 1242 1471 1362 1331 1264 1242 1312 1308 1433 1418 1589 1923 1902 2355 2431 2343 2122 1630 1391 1503 1593 1547 1365 1191 1102 1085 1057 1085 1076 983 958 1015 1035 1165 1171 1308 1214 1358 1447 1169 1057 794 730 542 753 775 879 745 333 458 267 259 286 165 91 143 -149 -248 -350 -331 -454 -544 -550 -431 -419 -460 -322 -286 -190 -313 -481 -402 -495 -451 -549 -564 -548 -567 -582 -717 -548 -551 -728 -613 -534 -502 -476 -455 -583 -629 -675 -747 -839 -749 -701 -634 -692 -597 -729 -705 -724 -696 -627 -765 -821 -823 -839 -768 -746 -696 -769 -927 -968 -810 -783 -651 -705 -624 -634 -678 -620 -492 -516 -647 -607 -579 -478 -500 -565 -592 -576 -554 -639 -662 -687 -699 -591 -476 -567 -475 -444 -350 -258 -315 -317 -482 -463 -363 -361 -372 -247 -191 -290 -331 -305 -306 -317 -341 -380 -370 -380 -401 -390 -431 -520 -586 -724 -756 -757 -789 -704 -913 -1025 -1054 -986 -762 -471 -259 -81 5 110 162 131 34 -70 -147 -220 -255 -39 64 259 239 241 213 52 -98 -254 -286 -281 -211 -72 131 285 256 239 301 256 265 279 416 511 565 570 638 675 727 756 797 793 826 779 710 769 719 749 795 831 716 741 685 652 566 587 504 604 748 728 775 773 828 866 820 733 684 685 579 470 454 460 473 515 559 577 528 469 461 463 346 297 304 250 219 217 113 81 73 62 12 -47 -84 -91 -62 -30 -40 -44 -86 -148 -177 -226 -261 -149 -25 -58 -118 -223 -287 -351 -438 -470 -530 -495 -491 -442 -378 -403 -353 -342 -350 -297 -357 -281 -225 -193 -142 -133 -224 -295 -256 -258 -328 -286 -290 -327 -272 -330 -297 -300 -319 -298 -276 -297 -298 -210 -172 -139 -121 -124 -121 -69 -29 -64 -70 -36 -85 -30 -35 -44 -41 -8 -41 -34 -82 -33 -61 -69 -91 -116 -96 -33 -49 66 9 11 80 63 77 80 114 109 168 214 258 247 229 240 271 222 199 186 206 178 188 207 211 180 152 120 142 161 159 166 131 116 160 194 241 204 249 197 171 171 88 -4 -30 -35 20 27 8 45 3 30 -5 31 23 29 90 74 5 -28 -19 -27 13 18 -31 -68 -67 -105 -90 -91 -137 -124 -135 -131 -101 -88 -95 -56 -71 -110 -80 -96 -59 -54 -97 -174 -223 -215 -186 -126 -104 -105 -171 -255 -250 -251 -225 -198 -281 -277 -312 -282 -260 -228 -141 0 83 94 45 -21 -52 -31 -20 -37 -21 65 124 72 48 73 91 48 103 137 194 261 255 254 286 294 347 388 -362 -360 -507 -535 -657 -587 -539 -359 -399 -401 -402 -431 -453 -382 -451 -462 -421 -533 -475 -539 -504 -497 -550 -633 -585 -665 -630 -500 -432 -404 -351 -255 -307 -320 -255 -258 -277 -185 -12 -22 -59 -60 14 58 120 130 33 138 211 224 198 309 315 372 357 392 490 527 531 497 507 495 608 721 673 669 648 644 680 674 729 713 788 933 896 1076 1094 1060 990 796 703 774 829 814 729 648 611 606 589 602 594 543 534 568 579 650 652 722 662 733 780 638 592 460 433 324 443 446 499 423 192 270 160 155 170 98 54 84 -88 -150 -199 -192 -269 -326 -330 -256 -247 -270 -186 -163 -107 -175 -270 -229 -287 -264 -323 -333 -325 -335 -342 -423 -325 -329 -446 -384 -335 -313 -292 -272 -344 -370 -401 -453 -522 -479 -460 -421 -464 -403 -496 -478 -486 -463 -416 -512 -562 -570 -575 -507 -463 -416 -461 -579 -644 -522 -511 -418 -443 -389 -394 -428 -399 -322 -345 -437 -408 -384 -309 -320 -365 -386 -381 -375 -435 -448 -459 -463 -392 -322 -400 -346 -324 -251 -177 -207 -202 -302 -295 -243 -252 -265 -178 -138 -208 -237 -218 -218 -221 -233 -259 -256 -266 -286 -280 -301 -346 -371 -439 -448 -451 -477 -425 -544 -602 -616 -587 -480 -320 -180 -61 4 91 136 107 27 -51 -103 -153 -186 -30 52 203 189 191 166 42 -74 -179 -195 -193 -152 -55 100 224 206 191 236 198 203 215 332 415 465 478 540 581 640 669 702 696 717 670 610 651 602 625 669 712 626 645 566 507 427 441 392 493 630 621 667 669 685 731 702 632 591 589 487 387 374 379 394 447 506 539 500 440 427 425 321 269 282 232 202 198 102 74 67 57 11 -44 -76 -82 -56 -28 -38 -43 -82 -141 -167 -214 -238 -138 -23 -55 -111 -208 -261 -330 -404 -428 -487 -459 -460 -401 -350 -381 -340 -331 -338 -289 -352 -282 -230 -201 -149 -139 -229 -295 -252 -254 -331 -298 -308 -347 -286 -345 -311 -316 -338 -318 -297 -324 -329 -234 -194 -159 -140 -145 -143 -82 -34 -76 -82 -42 -99 -35 -40 -51 -48 -10 -49 -40 -94 -37 -70 -79 -103 -134 -111 -38 -57 80 11 13 98 78 95 98 146 139 211 266 321 308 288 304 347 288 263 251 282 246 258 281 284 243 208 166 198 223 222 232 185 164 225 268 348 291 353 279 245 248 130 -6 -45 -53 30 40 11 67 4 45 -8 47 35 44 138 117 9 -45 -31 -43 20 29 -50 -110 -109 -171 -147 -150 -227 -206 -225 -219 -169 -146 -159 -94 -119 -184 -133 -160 -97 -89 -163 -278 -356 -363 -308 -207 -170 -173 -273 -415 -410 -412 -369 -327 -472 -473 -537 -483 -438 -375 -224 0 136 147 71 -34 -88 -53 -34 -63 -37 110 208 121 83 127 160 84 182 241 339 433 426 427 484 494 578 637 SQ 20221203T134707.6Z 8372.574393 118 1 50.51 2 84.80 120.56 139.97 335.65 0.00 1 0.00 1 0 65 3.329e-03 2.190e-03 2.329e-04 1.742e-04 4.865215e+03 3.663547e+01 3.661440e+02 3.903163e+02 6.811619e+02 285.00 -2.00 20.00 -2.00 451.56 0.00e+00 7.607634e-04 2.236646e-05 1.084588e-05 2.030068e-05 3.566733e-04 285.00 -2.00 20.00 -2.00 459.31 0.00e+00 8.482700e-04 1.600154e-06 5.641835e-06 1.402097e-05 3.017842e-05 225.05 -2.00 2.08 -2.00 446.89 0.00e+00 3.163917e+06 2.493622e+04 5.987610e+04 2.343628e+05 4.849526e+05 265.75 -2.00 10.73 -2.00 461.14 0.00e+00 1.060520e+00 4.069777e-03 6.172698e-03 8.489143e-03 1.035718e-01 224.33 -2.00 3.32 -2.00 458.65 0.00e+00 -1.800810e-05 5.325181e-07 7.191348e-07 1.194385e-06 1.271901e-05 285.00 -2.00 20.00 -2.00 459.05 0.00e+00 9.531 0.012 397.00 473.00 4 2.0354e+00 2.0886e-04 2.4496e-02 4.1966e-04 3.4674e-03 -1.2038e-01 2.8637e-04 5.1197e-03 3.3083e-04 4.6567e-03 3.7943e-02 1.3545e-04 6.7760e-04 1.2045e-04 2.1557e-03 1.4370e-02 5.6038e-05 7.5565e-05 3.2978e-05 8.2429e-04 -1.7979e-02 2.8008e-05 2.2927e-05 1.7364e-05 4.0389e-04 2.8441e-02 -1.2078e-01 9.1453e-05 4.1763e-05 7.0275e-05 1.9232e-03 4.3297e-05 2.0764e-06 1.0315e-06 3.6283e-07 3.5188e-05 -1.0604e-05 2.9175e-06 1.3736e-06 4.4407e-07 5.0120e-05 4.1784e-03 1.7660e-05 5.9534e-02 1.8969e-02 3.5580e-03 4.0420e-03 2.9902e-01 12 8 8 10 0 0 90.74 20.67 0.84 0.00418 0.00603 896 213 1 2 0 53.390 15.00 20.67 15.60 21.38 21.27 10.0 931.73 -316 -260 -738 -886 -1007 -805 -531 -349 -315 -270 -436 -516 -596 -516 -575 -473 -491 -571 -599 -520 -483 -536 -776 -825 -927 -921 -810 -533 -460 -404 -322 -350 -487 -579 -621 -549 -343 -154 -162 41 -116 -31 -100 -7 121 174 125 130 232 151 193 275 307 234 368 356 472 596 580 513 525 547 555 609 606 617 543 628 630 690 770 758 853 951 1079 1123 1239 1340 1090 980 833 861 773 767 632 548 466 490 453 478 549 502 456 493 517 525 562 579 613 685 644 618 546 475 376 415 370 408 390 341 157 129 114 38 50 8 34 -100 -120 -196 -223 -240 -322 -361 -311 -339 -305 -305 -304 -244 -245 -222 -242 -179 -229 -249 -286 -280 -299 -223 -310 -312 -282 -241 -314 -296 -255 -249 -200 -242 -239 -184 -261 -245 -325 -371 -314 -378 -324 -338 -363 -375 -310 -375 -297 -404 -474 -448 -453 -384 -288 -303 -349 -362 -473 -432 -390 -403 -348 -370 -323 -410 -281 -239 -283 -295 -330 -385 -296 -321 -346 -303 -325 -360 -286 -328 -288 -327 -242 -233 -247 -206 -98 -147 -81 -100 -114 -125 -242 -208 -225 -241 -216 -218 -245 -176 -177 -211 -171 -214 -184 -272 -208 -205 -168 -147 -141 -114 -190 -213 -226 -222 -268 -273 -238 -380 -391 -302 -247 -121 -96 -81 8 -10 -7 -51 -10 -63 -86 -36 -68 -18 54 99 83 107 102 68 -19 -41 -42 -28 35 101 171 126 170 101 98 90 114 203 259 330 294 351 372 375 436 401 380 395 409 404 404 401 430 452 430 507 470 456 346 321 374 359 435 502 429 402 407 430 433 416 391 342 313 317 253 268 252 271 276 298 260 274 217 212 198 149 139 153 108 53 57 28 15 83 29 27 -10 -43 -121 -77 -52 -44 -48 -88 -67 -156 -146 -120 -115 -85 -58 -104 -126 -148 -173 -149 -169 -152 -201 -200 -173 -150 -159 -123 -151 -136 -170 -160 -108 -122 -126 -116 -124 -185 -183 -205 -229 -157 -150 -177 -190 -225 -236 -236 -255 -234 -243 -235 -246 -223 -217 -235 -173 -157 -170 -112 -115 -73 -70 -53 -38 -38 -47 -43 -28 -43 -17 -7 5 -2 0 -32 -11 -30 -3 -44 7 28 41 43 17 55 45 28 67 102 80 122 158 155 180 182 179 144 166 102 118 113 95 68 143 131 131 116 89 66 102 81 116 89 79 80 112 163 159 150 173 143 146 83 50 41 19 25 20 35 18 16 39 19 16 38 13 47 19 -20 -35 -40 -38 -13 6 -33 -29 -29 -34 -36 -57 -45 -72 -61 -67 -49 -58 -65 -83 -63 -71 -66 -57 -36 -41 -43 -103 -148 -142 -125 -96 -67 -57 -116 -151 -173 -164 -141 -128 -171 -181 -208 -194 -184 -117 -61 24 73 92 40 -12 -25 -59 -49 -39 -34 22 37 24 48 52 5 10 66 73 120 142 154 164 191 189 252 268 -130 -107 -301 -357 -404 -325 -220 -148 -135 -117 -189 -224 -260 -226 -253 -210 -218 -255 -269 -235 -218 -240 -340 -351 -389 -392 -356 -242 -214 -190 -152 -161 -215 -266 -282 -253 -154 -72 -77 19 -58 -15 -49 -4 60 85 61 63 110 73 96 140 157 120 188 181 240 300 292 263 277 296 302 332 334 347 312 366 367 398 437 424 469 509 556 558 603 655 555 527 467 494 449 451 378 335 290 308 284 298 340 310 286 310 324 329 350 357 372 412 386 375 342 309 252 279 244 262 246 215 101 85 76 25 33 5 22 -66 -79 -132 -142 -157 -215 -243 -210 -226 -202 -201 -196 -156 -153 -138 -150 -113 -147 -162 -187 -184 -198 -146 -202 -204 -186 -160 -214 -207 -178 -174 -136 -159 -156 -118 -171 -164 -223 -264 -230 -280 -242 -238 -257 -264 -216 -259 -218 -280 -337 -322 -321 -261 -195 -196 -227 -246 -322 -309 -283 -287 -242 -254 -221 -285 -200 -173 -210 -220 -245 -282 -210 -225 -245 -217 -236 -268 -214 -244 -211 -236 -175 -172 -191 -155 -73 -116 -61 -71 -79 -84 -166 -151 -171 -176 -160 -161 -180 -129 -129 -153 -129 -157 -136 -203 -148 -148 -122 -103 -100 -76 -121 -133 -141 -141 -170 -171 -146 -231 -243 -200 -167 -91 -79 -67 7 -9 -6 -41 -8 -47 -64 -28 -53 -15 46 85 72 91 83 55 -14 -30 -31 -21 27 83 145 110 147 85 82 74 95 175 227 294 266 303 327 337 394 360 340 349 358 352 347 339 363 384 372 448 413 379 285 255 296 295 357 425 369 348 355 381 392 383 361 317 288 284 221 235 220 240 255 273 246 263 206 197 183 139 134 151 107 52 55 27 14 77 27 25 -10 -39 -110 -70 -49 -42 -46 -85 -64 -148 -140 -117 -114 -85 -57 -104 -125 -142 -163 -137 -154 -139 -186 -187 -165 -146 -158 -124 -153 -138 -166 -158 -109 -125 -132 -122 -130 -190 -184 -202 -238 -159 -157 -188 -201 -236 -247 -246 -267 -247 -258 -252 -267 -245 -241 -264 -197 -181 -200 -132 -135 -86 -82 -61 -44 -44 -54 -49 -32 -50 -20 -8 6 -2 -1 -36 -12 -33 -3 -50 8 32 49 52 21 69 57 36 85 128 100 149 192 189 219 223 222 180 210 131 155 152 128 91 189 172 172 155 120 89 138 110 157 122 109 110 158 227 219 204 236 198 205 118 72 60 28 37 29 51 26 23 56 27 23 55 20 70 28 -31 -54 -62 -58 -20 9 -51 -44 -44 -52 -57 -90 -72 -114 -96 -107 -78 -92 -105 -132 -100 -113 -105 -90 -57 -64 -69 -165 -237 -226 -197 -148 -104 -89 -185 -245 -283 -268 -231 -201 -272 -292 -339 -314 -294 -192 -97 36 112 143 63 -19 -40 -94 -79 -62 -55 35 59 37 77 85 8 16 109 120 196 233 253 272 319 314 415 434