File name: Pandora207s1_ArlingtonTX_20230210_L2Fit_ffus5c6d20221018p1-8.txt File generation date: 20240823T120640.7Z Data description: Level 2 spectral fitting results file Data file version: ffus5c6p1-8 Local principal investigator: Yang Li Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 207 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora207_OF_v5d20210722.txt Instrument calibration file used: Pandora207s1_CF_v6d20221018.txt Level 1 file used: Pandora207s1_ArlingtonTX_20230210_L1_smca1c6d20221018p1-8.txt Full location name: University Of Texas, Arlington Science Hall Short location name: ArlingtonTX Country of location: United States Location latitude [deg]: 32.7316 Location longitude [deg]: -97.1142 Location altitude [m]: 15 Local noon date: 20230210 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 5 "But different Reference day, final winter reference" First and last pixel inside fitting window: 324 589 Nominal wavelengths inside fitting window [nm]: 322.5163 322.6562 322.7962 322.9361 323.0759 323.2158 323.3557 323.4956 323.6354 323.7752 323.9151 324.0549 324.1947 324.3345 324.4742 324.6140 324.7538 324.8935 325.0332 325.1729 325.3127 325.4524 325.5920 325.7317 325.8714 326.0110 326.1507 326.2903 326.4299 326.5695 326.7091 326.8487 326.9883 327.1278 327.2674 327.4069 327.5465 327.6860 327.8255 327.9650 328.1044 328.2439 328.3834 328.5228 328.6623 328.8017 328.9411 329.0805 329.2199 329.3593 329.4986 329.6380 329.7773 329.9167 330.0560 330.1953 330.3346 330.4739 330.6131 330.7524 330.8917 331.0309 331.1701 331.3094 331.4486 331.5878 331.7269 331.8661 332.0053 332.1444 332.2836 332.4227 332.5618 332.7009 332.8400 332.9791 333.1181 333.2572 333.3962 333.5353 333.6743 333.8133 333.9523 334.0913 334.2303 334.3692 334.5082 334.6471 334.7861 334.9250 335.0639 335.2028 335.3417 335.4805 335.6194 335.7582 335.8971 336.0359 336.1747 336.3135 336.4523 336.5911 336.7299 336.8686 337.0074 337.1461 337.2848 337.4235 337.5622 337.7009 337.8396 337.9782 338.1169 338.2555 338.3942 338.5328 338.6714 338.8100 338.9486 339.0871 339.2257 339.3642 339.5028 339.6413 339.7798 339.9183 340.0568 340.1953 340.3337 340.4722 340.6106 340.7491 340.8875 341.0259 341.1643 341.3027 341.4410 341.5794 341.7177 341.8561 341.9944 342.1327 342.2710 342.4093 342.5476 342.6858 342.8241 342.9623 343.1006 343.2388 343.3770 343.5152 343.6534 343.7915 343.9297 344.0678 344.2060 344.3441 344.4822 344.6203 344.7584 344.8965 345.0345 345.1726 345.3106 345.4487 345.5867 345.7247 345.8627 346.0007 346.1386 346.2766 346.4145 346.5525 346.6904 346.8283 346.9662 347.1041 347.2419 347.3798 347.5177 347.6555 347.7933 347.9311 348.0689 348.2067 348.3445 348.4823 348.6200 348.7578 348.8955 349.0332 349.1709 349.3086 349.4463 349.5840 349.7216 349.8593 349.9969 350.1345 350.2721 350.4097 350.5473 350.6849 350.8225 350.9600 351.0976 351.2351 351.3726 351.5101 351.6476 351.7851 351.9225 352.0600 352.1974 352.3348 352.4723 352.6097 352.7471 352.8844 353.0218 353.1592 353.2965 353.4338 353.5712 353.7085 353.8458 353.9830 354.1203 354.2576 354.3948 354.5321 354.6693 354.8065 354.9437 355.0809 355.2180 355.3552 355.4924 355.6295 355.7666 355.9037 356.0408 356.1779 356.3150 356.4520 356.5891 356.7261 356.8632 357.0002 357.1372 357.2742 357.4111 357.5481 357.6851 357.8220 357.9589 358.0958 358.2327 358.3696 358.5065 358.6434 358.7802 358.9171 359.0539 359.1907 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Spectrometer control temperature [°C], 999=no temperature signal Column 165: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 166: Temperature in head sensor [°C], 999=no temperature signal Column 167: Temperature at electronics board 1 [°C], 999=no temperature signal Column 168: Temperature at electronics board 2 [°C], 999=no temperature signal Column 169: Humidity in head sensor [%], -9=no humidity signal Column 170: Pressure in head sensor [hPa], -9=no pressure signal Columns 171-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-702: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230210T155153.8Z 8441.661040 281 1 50.70 2 62.25 132.05 89.98 263.92 0.00 1 0.00 1 0 49 2.128e-03 1.631e-03 3.705e-04 3.309e-04 2.820206e-06 1.164728e-07 1.374110e-07 4.456207e-07 7.164209e-07 225.09 -2.00 3.32 -2.00 340.97 0.00e+00 -9.024184e-04 3.233998e-05 3.644013e-05 1.896109e-05 2.008862e-04 282.24 -2.00 20.00 -2.00 338.44 0.00e+00 3.556126e-04 4.705300e-06 2.004542e-06 2.959477e-05 3.304970e-05 282.24 -2.00 20.00 -2.00 346.95 0.00e+00 -2.055788e-04 1.384704e-05 1.389361e-05 1.712630e-05 9.701237e-05 282.24 -2.00 20.00 -2.00 345.61 0.00e+00 -7.854714e+05 2.949140e+04 4.287490e+04 2.332528e+05 1.845372e+05 263.58 -2.00 10.73 -2.00 352.22 0.00e+00 2.942770e-01 5.018755e-04 2.275884e-03 1.803180e-03 2.599491e-03 225.09 -2.00 3.32 -2.00 331.08 0.00e+00 1.447716e-02 7.751617e-04 6.096547e-03 1.378087e-04 3.149075e-03 282.24 -2.00 20.00 -2.00 329.10 0.00e+00 2.136 0.000 319.50 362.20 4 2.3799e+00 4.9393e-04 1.5097e-02 1.6909e-03 3.4405e-03 -6.1825e-04 1.2675e-04 2.3644e-03 2.9885e-04 7.7283e-04 -8.5667e-03 2.2850e-04 5.5664e-04 1.0362e-04 1.4508e-03 -2.8446e-03 1.3434e-04 7.8653e-04 3.5404e-05 6.3257e-04 5.2369e-03 1.9830e-04 4.4971e-04 7.7963e-05 1.1437e-03 2.0615e-02 -3.4035e-02 3.0397e-04 2.0007e-04 8.8537e-05 2.0439e-03 2.6185e-05 6.2033e-06 4.4712e-06 9.4691e-07 4.2067e-05 1.5345e-03 0.0000e+00 3.3497e-01 3.2591e-02 1.4243e-02 5.2128e-03 2.1136e-01 12 8 8 10 0 0 100.00 20.27 0.23 0.00153 0.00186 833 198 2 8 0 58.000 14.99 20.27 13.31 21.06 21.06 11.5 943.42 -76 378 787 1125 913 878 582 586 297 -30 -308 -553 -681 -717 -402 -432 43 36 149 58 -75 -278 -453 -385 -388 -226 -69 48 56 111 62 72 -28 -84 -116 -179 -88 -119 85 67 93 131 123 170 154 177 21 -18 1 15 27 14 9 -38 -65 -103 -10 -65 42 -58 -105 -111 -19 -4 -6 47 -63 19 103 187 130 214 202 191 167 130 116 34 68 11 43 -52 -139 -206 -304 -267 -182 -82 -86 92 39 40 -53 -125 -95 23 255 360 341 105 34 -47 77 238 317 225 19 -92 -237 -167 -176 8 -60 -106 -101 -193 -113 -102 28 90 231 129 139 157 98 181 167 155 130 160 71 5 -48 -49 -190 -197 -214 -242 -268 -322 -191 -178 -60 -68 99 71 111 241 188 227 180 133 12 16 8 126 297 149 103 -85 -87 -68 35 0 35 -71 -127 -147 -162 -111 -219 -58 -108 18 74 67 37 -68 -96 -160 -120 -156 -95 -83 -2 110 85 101 65 -2 -96 -118 -251 -272 -291 -255 -188 -53 64 171 287 266 260 126 51 -87 -61 -70 -106 7 23 94 37 -9 -139 -148 -135 -164 -156 -139 -13 9 59 4 30 -44 -54 -70 -94 2 20 144 213 295 217 192 73 83 70 74 125 109 220 96 -3 -165 -105 -248 -195 -77 -44 -17 -90 5 -131 -146 -251 -150 -177 -152 -96 -81 -14 -77 83 251 -33 158 330 482 410 416 288 302 160 -17 -180 -304 -384 -406 -225 -237 25 21 88 32 -44 -177 -309 -278 -293 -174 -53 38 44 88 50 57 -22 -66 -90 -137 -67 -89 62 49 67 95 89 125 117 140 18 -16 1 14 27 14 9 -38 -64 -96 -9 -56 35 -49 -89 -95 -16 -3 -5 42 -58 17 95 172 118 197 187 178 156 122 108 31 61 10 37 -45 -124 -191 -294 -265 -182 -82 -85 90 39 38 -52 -122 -98 22 220 293 279 91 30 -43 68 200 258 185 16 -87 -234 -168 -175 7 -58 -106 -96 -190 -114 -102 28 87 218 123 137 163 108 204 190 174 142 170 74 5 -49 -49 -189 -192 -208 -242 -280 -350 -212 -199 -66 -74 108 79 127 279 219 260 203 147 12 15 8 113 255 131 97 -80 -89 -74 40 0 40 -82 -143 -160 -169 -114 -226 -61 -119 20 87 81 45 -80 -106 -169 -123 -160 -101 -92 -3 126 98 117 76 -2 -106 -128 -267 -288 -312 -283 -217 -60 77 217 370 346 333 158 63 -103 -70 -78 -119 8 28 116 45 -10 -153 -153 -136 -170 -171 -162 -16 12 75 5 37 -55 -68 -89 -119 2 25 188 280 389 284 247 92 102 85 89 152 135 276 119 -4 -186 -109 -261 -198 -78 -46 -17 -97 5 -142 -148 -234 -139 -154 -130 -82 -73 -13 -79 94 289 SS 20230210T160200.2Z 8441.668058 287 1 1.38 2 60.69 134.20 92.05 265.21 0.00 1 0.00 1 0 49 2.115e-03 2.022e-03 2.062e-03 1.982e-03 2.405050e-07 6.761330e-07 6.962347e-08 4.457134e-07 7.116612e-07 225.09 -2.00 3.32 -2.00 339.80 0.00e+00 -3.592222e-06 1.859546e-04 1.696077e-05 1.892905e-05 1.983750e-04 282.24 -2.00 20.00 -2.00 337.20 0.00e+00 8.257605e-05 2.863269e-05 3.772074e-06 2.959303e-05 3.303441e-05 282.24 -2.00 20.00 -2.00 346.01 0.00e+00 3.034880e-04 8.429001e-05 1.881371e-05 1.717748e-05 9.627985e-05 282.24 -2.00 20.00 -2.00 344.60 0.00e+00 4.064988e+05 1.699579e+05 4.374620e+04 2.331617e+05 1.817831e+05 263.58 -2.00 10.73 -2.00 352.14 0.00e+00 2.781150e-01 2.687263e-03 2.127863e-03 1.803216e-03 2.562762e-03 225.09 -2.00 3.32 -2.00 330.04 0.00e+00 -3.417151e-03 3.811898e-03 3.539040e-03 1.231797e-04 3.128357e-03 282.24 -2.00 20.00 -2.00 327.93 0.00e+00 2.034 0.000 319.50 362.20 4 2.2847e+00 2.9837e-03 1.4377e-02 1.6901e-03 3.3627e-03 1.1500e-02 7.1902e-04 2.2532e-03 2.9902e-04 7.5649e-04 -1.2800e-03 1.3219e-03 4.3100e-04 9.6728e-05 1.4301e-03 -1.7009e-03 6.9477e-04 5.8337e-04 3.5074e-05 6.2591e-04 2.5939e-04 1.1031e-03 4.7471e-04 7.1604e-05 1.1239e-03 2.3219e-02 -2.2720e-04 1.8767e-03 2.5863e-04 9.4386e-05 1.9950e-03 5.1730e-05 3.7076e-05 4.5164e-06 9.3998e-07 4.1813e-05 1.0999e-03 0.0000e+00 3.6634e-01 1.9526e-01 1.8182e-02 5.5171e-03 2.1203e-01 12 9 9 12 1 1 999.00 20.27 0.17 0.00110 0.00174 2 41 2 8 0 283.450 15.00 20.27 13.72 21.06 21.06 11.7 949.44 150 336 -561 291 -367 454 -150 -217 41 -12 334 48 440 -524 124 -157 -256 311 196 -99 -564 -76 -46 148 -235 201 381 -130 137 -373 487 -272 -98 -442 -325 138 -155 -79 339 117 184 65 170 408 148 11 193 -126 -44 -369 75 -41 -104 -37 107 82 -126 -85 -95 374 -90 198 14 -181 -274 332 -167 113 87 119 62 -349 170 -400 339 -102 -79 -109 -92 -101 205 -328 181 4 -125 -240 111 56 -117 427 191 7 367 290 87 108 193 -246 2 -247 -340 97 -220 -198 176 274 -269 191 -217 -54 -93 -78 -211 -64 333 -59 -174 -118 417 22 162 134 -134 183 -5 -6 -208 -102 -5 -96 -15 -148 80 150 -22 -235 327 -16 -91 -140 -48 -174 -173 -86 306 293 -174 41 -52 411 -201 -101 -219 190 80 64 -43 258 263 -241 -76 -254 86 -176 122 5 -233 83 25 24 -167 18 -96 229 273 -230 9 -248 388 -334 290 86 36 37 222 546 -31 -38 -118 11 -259 225 -283 -92 57 12 69 -97 -107 123 66 356 -291 -199 -79 -135 -142 -98 -279 -101 235 151 13 -51 -53 50 202 382 -99 -360 205 -222 103 -145 158 61 70 -221 33 -67 111 236 -29 -112 247 -2 -156 88 -258 -76 96 122 -88 176 124 29 199 -179 -196 108 -163 -269 150 3 -10 184 -66 -84 -32 -277 36 -221 -200 -189 211 374 89 203 -341 171 -227 294 -97 -147 27 -9 243 34 326 -393 92 -114 -180 225 138 -73 -425 -59 -38 125 -201 175 333 -115 121 -333 435 -244 -88 -390 -284 118 -132 -69 289 99 155 54 144 350 126 10 176 -118 -42 -365 75 -41 -103 -37 107 79 -118 -79 -86 336 -82 182 13 -169 -260 309 -159 109 83 113 59 -335 164 -389 329 -99 -76 -103 -85 -94 188 -306 167 4 -121 -241 112 56 -116 421 192 7 380 301 87 105 177 -221 2 -227 -317 91 -208 -177 158 248 -251 184 -214 -54 -93 -76 -205 -64 331 -61 -181 -121 432 22 160 134 -139 195 -6 -6 -230 -111 -5 -101 -16 -155 83 154 -22 -241 332 -16 -97 -150 -53 -186 -188 -92 329 313 -191 46 -58 450 -217 -110 -226 193 76 60 -39 236 249 -236 -79 -271 92 -194 134 6 -251 88 26 25 -174 19 -101 248 296 -256 10 -270 409 -345 297 89 37 39 239 591 -34 -40 -126 12 -273 235 -294 -94 59 12 73 -107 -123 144 77 417 -337 -231 -89 -151 -157 -106 -303 -114 267 172 15 -57 -56 53 207 399 -104 -396 230 -251 118 -170 184 72 83 -260 38 -79 132 283 -35 -133 290 -2 -180 102 -293 -86 109 141 -101 204 138 31 206 -179 -195 106 -163 -277 157 3 -10 185 -64 -78 -29 -250 32 -205 -193 -193 220 415 SS 20230210T160713.6Z 8441.671685 289 1 10.91 2 59.91 135.35 93.13 265.88 0.00 1 0.00 1 0 33 5.384e-04 5.051e-04 4.882e-04 4.670e-04 5.073592e-07 1.597657e-07 7.016302e-08 4.457099e-07 1.811687e-07 225.09 -2.00 3.32 -2.00 339.84 0.00e+00 1.220376e-04 4.389502e-05 1.577887e-05 1.892471e-05 5.036479e-05 282.24 -2.00 20.00 -2.00 337.25 0.00e+00 4.865367e-05 6.749821e-06 2.159436e-06 2.959298e-05 8.427445e-06 282.24 -2.00 20.00 -2.00 346.05 0.00e+00 2.049916e-04 1.985104e-05 1.500457e-05 1.718145e-05 2.450268e-05 282.24 -2.00 20.00 -2.00 344.63 0.00e+00 2.335922e+05 4.017263e+04 3.379552e+04 2.331604e+05 4.621555e+04 263.58 -2.00 10.73 -2.00 352.08 0.00e+00 2.698446e-01 6.344642e-04 2.056180e-03 1.803078e-03 6.500578e-04 225.09 -2.00 3.32 -2.00 330.12 0.00e+00 1.292733e-03 9.133232e-04 6.397378e-04 1.239430e-04 7.965379e-04 282.24 -2.00 20.00 -2.00 328.02 0.00e+00 1.986 0.000 319.50 362.20 4 2.2598e+00 7.0340e-04 1.4037e-02 1.6902e-03 8.5738e-04 1.2608e-02 1.6883e-04 2.1960e-03 2.9898e-04 1.9199e-04 -1.1426e-03 3.1143e-04 4.2054e-04 9.6855e-05 3.6354e-04 -8.1003e-04 1.6575e-04 3.8032e-04 3.5217e-05 1.5903e-04 4.0035e-04 2.6094e-04 2.9174e-04 7.1669e-05 2.8547e-04 2.4726e-02 -2.7979e-03 4.4315e-04 2.2895e-04 9.4146e-05 5.1170e-04 -2.2612e-05 8.7043e-06 4.2334e-06 9.6317e-07 1.0641e-05 1.4920e-03 0.0000e+00 -9.9627e-02 4.6295e-02 1.6349e-02 5.5767e-03 5.4329e-02 12 9 1 12 1 1 99.96 20.27 0.26 0.00149 0.00121 45 52 1 8 0 223.580 15.00 20.27 14.30 21.06 21.06 11.8 953.21 69 5 14 -40 -33 149 81 87 54 29 1 38 -31 -211 -122 -123 51 14 -1 4 -59 43 55 31 -29 -48 -14 15 67 31 -131 -102 60 -53 -102 -44 86 -27 -49 73 -31 89 166 151 -12 59 -2 -24 25 64 -50 36 0 -8 -40 -61 -17 -57 -26 1 -159 47 -11 -36 57 -70 -63 113 126 -91 29 44 16 52 37 -4 25 -58 -34 31 29 -46 3 -35 -69 43 -35 57 23 5 31 8 29 -12 -55 -59 52 -31 -26 -23 19 17 23 -4 -40 -2 -120 49 -23 -89 -11 37 104 -27 54 -8 -68 -56 3 6 59 34 33 48 -24 -46 -32 58 26 32 63 31 23 40 31 22 23 -51 -51 -31 14 42 6 22 -11 -42 -47 -8 -70 14 68 6 0 -26 32 68 44 -13 43 -23 -38 11 -26 42 -23 -60 7 -52 29 -56 -38 -19 -20 14 -70 -31 43 -9 40 -75 44 0 -3 -12 -48 98 48 -14 -12 -32 -12 -56 37 12 3 -2 40 -44 -32 0 -6 5 -22 35 -57 -2 29 -6 -22 34 -14 -4 7 61 41 -11 30 -78 -10 8 26 41 85 -12 -30 14 -1 -42 -9 48 -71 58 -25 35 60 19 -45 49 -82 -16 37 -13 48 84 -28 -48 -23 49 -19 -68 -31 8 -4 20 1 111 -71 -159 13 -82 -30 -45 -1 -27 59 74 40 3 8 -23 -20 95 51 57 36 20 0 28 -23 -157 -90 -89 36 9 -1 3 -44 34 45 27 -24 -42 -12 13 59 27 -117 -91 53 -46 -88 -38 73 -23 -42 62 -27 75 141 130 -10 52 -2 -23 24 63 -50 37 0 -9 -39 -58 -16 -52 -24 1 -142 43 -10 -33 52 -67 -61 110 122 -88 28 42 15 51 36 -4 24 -56 -32 28 26 -42 3 -34 -66 43 -35 57 23 5 31 8 29 -13 -57 -58 49 -28 -23 -22 17 16 21 -4 -35 -2 -108 48 -23 -89 -11 36 100 -27 55 -8 -71 -58 3 6 60 35 33 50 -26 -49 -35 65 29 34 67 33 24 41 31 22 23 -53 -53 -34 16 47 6 24 -12 -47 -51 -9 -77 16 76 6 0 -26 31 62 41 -12 41 -22 -40 12 -28 45 -25 -65 7 -55 30 -59 -40 -20 -22 15 -77 -35 49 -10 44 -77 45 0 -3 -13 -51 106 52 -16 -13 -34 -12 -59 38 12 3 -2 43 -49 -37 0 -8 6 -25 42 -66 -3 32 -6 -24 38 -16 -4 8 67 44 -11 30 -81 -11 8 30 47 99 -15 -35 17 -1 -50 -11 57 -85 69 -30 42 71 22 -53 56 -93 -18 42 -16 56 96 -31 -52 -24 49 -19 -68 -31 8 -5 21 1 111 -68 -144 12 -71 -26 -42 -1 -28 61 81 SS 20230210T170746.1Z 8441.713728 316 1 44.01 2 52.19 150.42 105.59 273.65 0.00 1 0.00 1 0 33 7.659e-03 7.453e-03 6.707e-03 6.315e-03 7.327162e-07 2.132143e-06 9.108391e-08 4.458565e-07 2.571335e-06 225.09 -2.00 3.32 -2.00 338.92 0.00e+00 -2.022883e-04 5.684728e-04 1.503326e-05 1.885074e-05 6.886897e-04 282.24 -2.00 20.00 -2.00 336.52 0.00e+00 -1.387994e-04 9.621412e-05 1.205023e-05 2.959259e-05 1.247881e-04 282.24 -2.00 20.00 -2.00 345.13 0.00e+00 8.475410e-04 2.810820e-04 4.817687e-05 1.721592e-05 3.472357e-04 282.24 -2.00 20.00 -2.00 343.48 0.00e+00 3.562901e+05 5.330775e+05 1.086728e+05 2.330971e+05 6.370459e+05 263.58 -2.00 10.73 -2.00 350.78 0.00e+00 2.461548e-01 8.103097e-03 1.822258e-03 1.802916e-03 9.010923e-03 225.09 -2.00 3.32 -2.00 330.18 0.00e+00 1.831982e-02 1.250367e-02 1.461783e-02 1.346307e-04 1.131884e-02 282.24 -2.00 20.00 -2.00 328.15 0.00e+00 1.627 0.000 319.50 362.20 4 7.7394e+00 9.5602e-03 1.1618e-02 1.6894e-03 1.1965e-02 1.1525e-01 2.1359e-03 1.8825e-03 2.9831e-04 2.5926e-03 -1.1862e-02 4.0462e-03 5.0049e-04 9.3518e-05 4.9970e-03 1.0473e-03 2.2601e-03 1.8377e-03 3.4820e-05 2.2091e-03 5.1898e-06 3.4350e-03 1.4592e-03 6.7917e-05 3.8395e-03 1.3172e-04 -1.7816e-02 6.2110e-03 3.3752e-04 8.5994e-05 7.7252e-03 -1.5513e-04 1.2684e-04 6.6120e-06 1.0943e-06 1.5112e-04 -4.3310e-04 0.0000e+00 2.2814e+00 6.4094e-01 2.0063e-02 4.9161e-03 7.9024e-01 12 8 8 10 0 0 64.61 20.25 1.70 -0.00043 -0.00235 11 4 2 8 0 4000.000 15.00 20.25 14.01 21.06 21.06 11.6 949.31 -1378 1799 138 -949 411 -953 446 -16 1383 -1184 959 447 254 -42 -1022 1206 -557 899 -1697 -536 182 -141 -399 -132 754 144 14 -13 -240 -1164 620 408 -920 450 435 1368 -562 704 -392 402 482 -265 -958 -359 -284 -543 812 -620 571 -22 -130 211 -210 164 -90 -74 -373 1493 -1105 -235 -855 1970 -855 68 -838 -69 444 -798 987 -901 643 -835 471 508 -284 100 1231 645 -1093 42 490 -1307 945 81 150 1069 1641 -937 -327 -363 516 -1273 -301 475 -876 -197 -457 118 426 930 -913 -759 -175 1128 144 -470 576 725 1252 -1190 1912 -549 284 -577 358 268 -400 110 -115 474 -251 354 -285 76 -160 -297 546 -55 663 -665 367 -1011 374 -756 -599 -322 658 -205 -440 157 -1381 1338 -900 1095 -1107 -198 -195 233 12 -194 677 -779 680 572 -189 -583 -288 -1077 -1663 1654 -1226 234 306 697 552 515 -486 -425 -417 -315 2032 -1513 141 462 201 -59 831 -350 -427 647 883 -305 -374 -47 -97 -136 1707 50 421 -371 1008 -534 39 -1764 120 -906 -240 648 -904 -861 -421 1019 -421 1388 -382 746 952 825 -399 -16 -147 -835 768 -525 642 554 19 -33 507 -1282 -614 640 -122 1273 -558 -739 -178 281 455 166 128 317 -19 -1086 1304 -601 1020 -13 -374 -970 1259 314 -469 -81 -731 534 -802 -432 -974 -83 -195 -392 271 -1164 -277 -1194 137 -135 -1407 -764 826 -304 968 853 842 1076 -742 908 70 -501 223 -548 263 -10 867 -789 648 314 183 -30 -743 842 -386 607 -1187 -384 137 -114 -345 -120 706 138 14 -13 -233 -1146 602 396 -898 428 409 1262 -522 635 -351 353 421 -232 -846 -319 -257 -513 801 -654 622 -25 -150 245 -246 190 -102 -81 -390 1468 -1081 -227 -841 1896 -851 67 -844 -70 457 -836 1011 -934 651 -859 481 521 -294 103 1241 640 -1079 40 459 -1257 912 81 156 1137 1745 -1015 -349 -385 551 -1427 -342 535 -958 -197 -418 101 366 829 -864 -724 -162 978 122 -404 517 696 1254 -1242 1920 -552 282 -592 375 290 -447 121 -125 498 -260 367 -309 86 -191 -366 673 -68 780 -767 408 -1124 407 -819 -638 -336 675 -218 -488 179 -1641 1550 -1049 1233 -1283 -231 -233 281 13 -232 785 -896 732 573 -175 -495 -233 -893 -1474 1546 -1279 255 316 733 582 541 -503 -422 -438 -324 2048 -1472 140 472 211 -63 886 -368 -427 607 879 -279 -355 -46 -97 -138 1703 50 424 -372 967 -505 36 -1647 111 -877 -241 684 -1033 -1026 -512 1227 -506 1599 -437 813 994 844 -413 -17 -163 -955 859 -568 643 520 17 -31 499 -1364 -681 724 -141 1481 -674 -904 -219 345 511 188 146 363 -22 -1269 1474 -679 1105 -14 -394 -1023 1306 333 -507 -86 -751 509 -713 -358 -785 -65 -160 -339 244 -1085 -250 -1019 106 -96 -954 -505 540 -211 729 714 777 1078 SS 20230210T174841.0Z 8441.742142 335 1 2.10 2 48.73 162.48 113.94 279.21 0.00 1 0.00 1 0 33 5.937e-04 5.798e-04 6.028e-04 5.862e-04 -1.051360e-07 1.981072e-07 3.653183e-08 4.457576e-07 1.996690e-07 225.09 -2.00 3.32 -2.00 339.36 0.00e+00 6.138128e-05 5.384891e-05 8.460470e-06 1.888687e-05 5.492606e-05 282.24 -2.00 20.00 -2.00 336.71 0.00e+00 3.473573e-05 8.653075e-06 1.010869e-06 2.959218e-05 9.409176e-06 282.24 -2.00 20.00 -2.00 345.65 0.00e+00 1.236742e-04 2.510459e-05 1.051122e-05 1.720548e-05 2.696819e-05 282.24 -2.00 20.00 -2.00 344.18 0.00e+00 9.036125e+04 4.962203e+04 2.459524e+04 2.331190e+05 5.032850e+04 263.58 -2.00 10.73 -2.00 351.97 0.00e+00 2.090905e-01 7.468859e-04 1.587794e-03 1.802944e-03 6.956025e-04 225.09 -2.00 3.32 -2.00 329.76 0.00e+00 -2.568456e-04 1.071200e-03 3.341033e-04 1.275750e-04 8.786965e-04 282.24 -2.00 20.00 -2.00 327.66 0.00e+00 1.513 0.000 319.50 362.20 4 1.3636e+00 8.8698e-04 1.0695e-02 1.6897e-03 9.4656e-04 5.1896e-03 2.0442e-04 1.6744e-03 2.9885e-04 2.0703e-04 -5.9698e-04 3.8495e-04 2.9629e-04 9.3417e-05 3.9643e-04 -9.9866e-04 1.9727e-04 2.8996e-04 3.5046e-05 1.7381e-04 3.1980e-04 3.1682e-04 2.0991e-04 6.8779e-05 3.0891e-04 8.4858e-02 -1.5365e-03 5.6685e-04 1.6483e-04 9.4402e-05 5.8189e-04 9.5727e-06 1.1022e-05 3.4607e-06 9.8087e-07 1.1728e-05 1.0627e-03 0.0000e+00 -2.3900e-01 5.9553e-02 1.1271e-02 5.6648e-03 6.1814e-02 12 9 1 12 1 1 99.52 20.23 0.32 0.00106 0.00118 24 156 2 8 0 73.870 15.00 20.23 14.82 21.06 21.06 11.6 955.37 -129 8 200 -21 65 24 -67 7 -78 19 52 -104 -88 -1 0 -47 -29 -10 132 -11 56 37 -31 36 -60 72 28 -140 35 73 -47 -3 70 72 -43 -47 -60 -50 28 -24 81 -66 6 65 8 46 -32 114 27 -4 58 -18 -14 -51 -98 19 -32 42 -26 24 -32 -59 -16 46 3 -29 -32 89 37 38 42 15 149 -94 32 28 -179 -24 -74 33 41 -6 47 -4 -43 -88 -105 57 0 8 22 30 -51 125 -65 -25 -73 37 28 -70 -14 -39 8 46 30 84 -109 -66 -33 98 47 52 -19 58 11 -14 23 28 -57 -6 25 18 -46 -85 42 10 70 -37 10 -64 -15 -92 82 36 -10 -9 121 -49 -27 42 -38 10 35 21 39 -14 1 -13 -75 -103 -38 -57 56 54 38 -25 7 33 -10 -77 24 164 43 -18 76 23 34 21 -71 -102 -38 19 40 88 -45 47 33 -37 -28 51 -87 -5 -130 -42 19 26 107 -31 -12 -58 32 -33 -111 3 141 -13 -55 65 -52 3 -8 85 72 -46 30 59 64 15 -16 -108 8 -114 55 -77 -81 -66 33 12 -14 -1 2 85 -15 78 42 -26 -25 -40 -21 -24 26 9 -27 14 -48 34 12 -2 42 8 21 -53 -13 0 66 -29 -5 13 -50 77 -30 -114 72 75 1 -7 -15 37 20 17 94 -153 -42 -47 51 2 -84 5 130 -14 43 16 -46 5 -57 14 40 -81 -68 0 0 -37 -22 -8 102 -8 46 31 -27 31 -54 67 26 -130 32 68 -44 -3 65 66 -39 -43 -54 -44 25 -22 72 -58 5 58 7 42 -30 109 27 -4 59 -18 -15 -52 -100 20 -31 40 -24 22 -30 -56 -15 44 3 -28 -31 86 36 36 42 14 143 -91 31 27 -173 -24 -71 31 38 -5 45 -4 -43 -87 -105 56 0 9 21 31 -54 132 -66 -24 -68 34 25 -66 -14 -37 8 42 28 75 -103 -65 -33 99 47 51 -19 58 11 -14 24 28 -60 -6 24 18 -48 -90 46 11 76 -41 11 -69 -16 -95 84 37 -11 -9 121 -51 -28 44 -41 10 37 22 41 -16 2 -15 -82 -114 -42 -61 58 54 36 -23 6 30 -10 -76 24 174 46 -19 81 24 36 22 -73 -102 -38 20 41 95 -48 51 36 -40 -30 52 -89 -5 -135 -43 21 28 115 -32 -12 -62 33 -34 -113 3 144 -13 -58 70 -58 4 -9 99 83 -52 34 66 68 16 -17 -118 9 -130 62 -86 -86 -68 33 12 -14 -1 2 95 -17 87 48 -30 -28 -46 -24 -27 30 11 -32 16 -56 39 14 -2 46 9 24 -59 -15 0 72 -30 -5 13 -48 75 -29 -114 74 76 1 -7 -14 34 17 14 82 -135 -38 -46 53 2