File name: Pandora119s1_Athens-NOA_20211117_L2Fit_fsus1c3d20201216p1-8.txt File generation date: 20250409T110746.9Z Data description: Level 2 spectral fitting results file Data file version: fsus1c3p1-8 Local principal investigator: Stelios Kazadsis Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 119 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora119_OF_v1d20201007.txt Instrument calibration file used: Pandora119s1_CF_v3d20201216.txt Level 1 file used: Pandora119s1_Athens-NOA_20211117_L1_smca1c3d20201216p1-8.txt Full location name: National Observatory of Athens, Thiseio Short location name: Athens-NOA Country of location: Greece Location latitude [deg]: 37.9878 Location longitude [deg]: 23.7750 Location altitude [m]: 130 Local noon date: 20211117 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 232 376 Nominal wavelengths inside fitting window [nm]: 306.1334 306.2745 306.4157 306.5569 306.6980 306.8392 306.9803 307.1215 307.2626 307.4037 307.5448 307.6858 307.8269 307.9680 308.1090 308.2501 308.3911 308.5321 308.6731 308.8141 308.9551 309.0960 309.2370 309.3779 309.5189 309.6598 309.8007 309.9416 310.0825 310.2234 310.3643 310.5051 310.6460 310.7868 310.9276 311.0685 311.2093 311.3501 311.4908 311.6316 311.7724 311.9131 312.0538 312.1946 312.3353 312.4760 312.6167 312.7574 312.8980 313.0387 313.1793 313.3200 313.4606 313.6012 313.7418 313.8824 314.0230 314.1635 314.3041 314.4446 314.5852 314.7257 314.8662 315.0067 315.1472 315.2877 315.4281 315.5686 315.7090 315.8495 315.9899 316.1303 316.2707 316.4111 316.5515 316.6918 316.8322 316.9725 317.1129 317.2532 317.3935 317.5338 317.6741 317.8144 317.9546 318.0949 318.2351 318.3753 318.5156 318.6558 318.7960 318.9361 319.0763 319.2165 319.3566 319.4968 319.6369 319.7770 319.9171 320.0572 320.1973 320.3374 320.4774 320.6175 320.7575 320.8975 321.0376 321.1776 321.3176 321.4575 321.5975 321.7375 321.8774 322.0173 322.1573 322.2972 322.4371 322.5770 322.7169 322.8567 322.9966 323.1364 323.2763 323.4161 323.5559 323.6957 323.8355 323.9752 324.1150 324.2548 324.3945 324.5342 324.6739 324.8136 324.9533 325.0930 325.2327 325.3724 325.5120 325.6516 325.7913 325.9309 326.0705 326.2101 326.3496 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20211117T093751.9Z 7991.401295 359 1 49.25 2 57.56 171.02 130.88 16.31 0.00 1 0.00 1 0 49 6.218e-03 2.337e-03 5.966e-03 2.279e-03 -1.378180e-07 8.284129e-07 1.573495e-08 4.461431e-07 2.781268e-06 223.76 -2.00 3.45 -2.00 321.98 0.00e+00 7.137801e-04 3.096158e-04 1.727248e-05 5.434165e-05 7.449757e-04 281.86 -2.00 20.00 -2.00 322.05 0.00e+00 -7.040282e-04 4.205952e-04 2.439774e-06 3.030319e-05 1.311736e-03 281.86 -2.00 20.00 -2.00 321.78 0.00e+00 -5.387438e-06 6.338245e-04 4.713480e-05 4.262350e-05 1.362835e-03 281.86 -2.00 20.00 -2.00 321.87 0.00e+00 2.294998e-01 3.351146e-03 1.635353e-04 2.249321e-03 7.636739e-03 228.11 3.52 0.00 1.58 13.30 318.32 0.00e+00 9.307211e-05 1.769761e-04 2.715660e-06 5.492178e-05 1.799062e-04 281.86 -2.00 20.00 -2.00 317.59 0.00e+00 1.858 0.000 303.00 329.40 4 4.4261e+00 8.5392e-03 1.7799e-02 2.3039e-03 2.4029e-02 3.4794e-02 1.2292e-02 1.9487e-03 3.2979e-04 2.5799e-02 -5.9460e-04 6.6529e-03 3.3864e-04 9.0820e-05 1.4212e-02 -4.5698e-03 2.8135e-03 9.2812e-05 3.6324e-05 5.4583e-03 2.1011e-03 1.8750e-03 3.4374e-05 5.9379e-05 3.6349e-03 6.4515e-04 -1.0952e-03 1.8685e-03 7.2068e-05 2.0948e-05 2.0717e-03 2.0798e-04 6.6507e-05 1.9983e-06 6.8051e-07 1.7614e-04 1.2302e-02 -6.3189e-05 3.0631e-01 2.1660e-01 2.5507e-03 5.6534e-04 5.0652e-01 12 8 8 10 0 0 99.89 20.04 0.25 0.01230 0.01389 51 12 1 5 0 965.536 25.47 20.01 20.04 20.45 32.3 933.74 2089 -960 -2212 2459 -1377 1912 -1716 607 549 1159 438 -593 141 -724 359 -177 551 232 -1182 1326 -2162 1548 -787 10 625 17 615 -1017 732 -830 560 -241 -185 -394 -126 476 -136 590 -252 195 -457 -574 13 -443 -21 -81 405 -75 73 285 -586 534 -139 368 -184 399 -259 -235 -238 -431 706 -395 559 -181 -219 357 -298 661 -454 147 -1 472 227 -150 -182 -135 148 -262 156 -36 108 54 -34 -113 -310 233 121 91 277 154 255 -268 90 -117 28 -114 -505 22 -56 -72 -168 255 -121 0 155 95 187 -319 51 -413 127 -288 90 388 -324 347 -158 51 160 -90 46 -217 90 -85 -46 -52 -103 43 60 198 -140 227 30 -53 12 -118 -7 -184 57 215 97 -45 -5 -6 -131 238 -121 -283 296 -187 286 -302 116 110 235 93 -131 32 -163 80 -42 136 60 -313 325 -506 341 -183 2 166 5 165 -262 198 -256 204 -104 -87 -193 -63 240 -69 303 -128 95 -219 -272 6 -233 -12 -47 236 -44 44 172 -350 319 -85 235 -128 295 -195 -164 -155 -270 456 -287 445 -151 -184 287 -227 458 -285 88 0 321 175 -125 -162 -125 142 -272 170 -40 121 58 -34 -105 -264 193 105 86 288 173 305 -319 100 -122 28 -116 -553 26 -68 -90 -216 346 -173 0 214 125 223 -367 58 -486 160 -381 122 516 -432 439 -189 60 177 -100 55 -270 118 -113 -62 -74 -150 65 94 309 -222 356 45 -77 17 -177 -11 -311 102 406 190 -91 -9 -13 -259 SS 20211117T103802.6Z 7991.443085 394 1 48.70 2 57.46 187.89 125.87 33.34 0.00 1 0.00 1 0 49 3.462e-03 1.399e-03 3.038e-03 1.168e-03 -5.743699e-07 4.237835e-07 1.243759e-08 4.461402e-07 1.553177e-06 223.76 -2.00 3.45 -2.00 321.99 0.00e+00 6.223087e-04 1.591963e-04 1.198021e-05 5.435921e-05 4.153815e-04 281.86 -2.00 20.00 -2.00 322.05 0.00e+00 -1.484209e-04 2.156786e-04 2.999439e-06 3.029855e-05 7.299952e-04 281.86 -2.00 20.00 -2.00 321.79 0.00e+00 -1.547281e-04 3.279849e-04 1.828122e-05 4.258988e-05 7.586978e-04 281.86 -2.00 20.00 -2.00 321.88 0.00e+00 2.275954e-01 1.724901e-03 7.110190e-05 2.249510e-03 4.252361e-03 227.30 1.81 0.00 1.60 7.40 318.37 0.00e+00 9.875565e-05 9.112602e-05 2.175568e-06 5.492219e-05 1.002323e-04 281.86 -2.00 20.00 -2.00 317.64 0.00e+00 1.853 0.000 303.00 329.40 4 3.0919e+00 4.3376e-03 1.7748e-02 2.3040e-03 1.3379e-02 2.0879e-02 6.2959e-03 1.8483e-03 3.2916e-04 1.4370e-02 1.5113e-03 3.4128e-03 1.9753e-04 9.0227e-05 7.9162e-03 -2.1529e-03 1.4408e-03 6.3695e-05 3.7139e-05 3.0408e-03 1.3669e-05 9.6074e-04 1.2096e-05 6.0337e-05 2.0251e-03 2.4786e-03 2.4205e-03 9.6050e-04 5.7297e-05 2.0388e-05 1.1273e-03 2.9817e-04 3.3808e-05 1.7999e-06 6.8814e-07 9.8093e-05 1.0767e-02 -3.3199e-05 -1.2783e-01 1.1084e-01 1.6720e-03 5.1223e-04 2.8129e-01 11 8 0 10 0 0 99.94 20.16 0.17 0.01077 0.01304 247 57 1 5 0 197.106 25.58 20.00 20.16 22.01 32.6 944.16 1458 -448 -45 -112 -865 759 -822 977 -489 -112 379 -682 718 -772 585 -602 1003 -88 -5 363 -892 474 -559 895 645 -63 -276 -458 107 -610 349 -172 -73 -254 -185 -153 -112 333 -335 113 -261 -314 503 -166 348 -56 195 8 289 185 -263 221 -339 187 -147 320 -150 12 -16 -348 474 -38 171 55 -71 12 -172 33 -272 206 -202 -40 277 83 98 -256 67 -104 116 -235 -25 41 1 92 -292 120 34 242 89 50 20 -194 119 -140 62 40 -44 -39 -330 167 -76 94 -9 -24 157 22 133 -88 70 -203 70 -166 -22 189 85 197 9 34 -109 -47 3 -106 34 -199 52 -94 -85 -41 27 94 -11 50 3 56 -9 -44 66 -76 -6 7 70 10 -8 11 -50 170 -57 -6 -14 -119 117 -147 177 -94 -22 82 -144 165 -179 133 -146 254 -24 -1 93 -212 105 -129 220 171 -18 -75 -117 29 -193 131 -71 -33 -122 -92 -76 -56 164 -164 53 -120 -142 234 -84 184 -31 112 5 172 111 -154 127 -201 118 -101 234 -111 8 -10 -209 295 -27 135 46 -59 9 -129 22 -177 125 -127 -26 205 68 86 -236 65 -110 128 -269 -28 45 1 85 -246 96 29 226 92 58 25 -235 135 -144 61 40 -49 -46 -406 213 -102 124 -12 -33 212 30 162 -100 80 -243 90 -229 -29 263 115 255 12 40 -120 -52 4 -135 45 -272 72 -135 -122 -62 42 148 -18 77 5 80 -13 -64 103 -130 -12 14 136 20 -15 22 -98 SS 20211117T111814.8Z 7991.471005 418 1 11.26 2 59.30 198.83 121.02 43.16 0.00 1 0.00 1 0 49 4.069e-03 1.993e-03 4.292e-03 2.035e-03 1.103849e-07 7.443110e-07 2.150478e-08 4.460813e-07 1.821522e-06 223.76 -2.00 3.45 -2.00 321.44 0.00e+00 5.344500e-04 2.672057e-04 2.234781e-05 5.428042e-05 4.866621e-04 281.86 -2.00 20.00 -2.00 321.26 0.00e+00 -1.929761e-04 3.698509e-04 3.207164e-06 3.030393e-05 8.577225e-04 281.86 -2.00 20.00 -2.00 321.39 0.00e+00 2.690393e-04 5.194088e-04 3.672439e-05 4.256776e-05 8.916130e-04 281.86 -2.00 20.00 -2.00 321.34 0.00e+00 2.403698e-01 2.783548e-03 9.827648e-05 2.249336e-03 5.007880e-03 226.49 2.80 0.00 1.51 8.70 317.49 0.00e+00 1.068227e-04 1.326596e-04 1.427366e-06 5.491791e-05 1.183858e-04 281.86 -2.00 20.00 -2.00 316.84 0.00e+00 1.951 0.000 303.00 329.40 4 3.3633e+00 7.3550e-03 1.8691e-02 2.3048e-03 1.5730e-02 1.9818e-02 1.0022e-02 1.9782e-03 3.3000e-04 1.6900e-02 7.0399e-04 5.4815e-03 3.0047e-04 8.6118e-05 9.2971e-03 1.3108e-03 2.3147e-03 7.5901e-05 3.0187e-05 3.6006e-03 -1.8417e-03 1.5962e-03 6.0504e-05 5.4208e-05 2.4011e-03 1.6825e-03 9.2331e-04 1.3778e-03 4.5662e-05 1.4460e-05 1.2361e-03 2.0132e-04 5.7136e-05 1.6577e-06 6.8350e-07 1.1546e-04 9.2435e-03 -5.1664e-06 2.1567e-01 1.8152e-01 2.8877e-03 5.2865e-04 3.2536e-01 12 9 9 12 1 1 99.85 20.24 0.25 0.00924 0.01078 15 16 1 5 0 693.269 25.58 19.98 20.24 22.81 32.4 947.61 426 -906 -271 1550 221 1180 -1295 528 94 -135 -441 -638 1356 -538 1075 184 -631 145 -756 320 -286 1042 -41 -1295 55 -126 -86 -1128 638 -187 449 43 367 232 -222 -73 -522 192 66 442 94 -192 416 -530 -44 -427 101 179 -49 166 -38 -14 -555 187 92 225 -143 -49 22 -16 -78 303 157 166 -315 179 -442 584 -58 69 235 25 -55 -279 234 -256 258 -484 58 135 5 -23 12 396 -220 -526 77 39 306 -222 139 13 181 -32 -110 122 -111 -35 -1 128 85 -222 42 -55 97 -205 198 15 184 -263 -162 -212 -7 287 -84 110 -68 -140 28 -197 9 144 82 75 9 -105 -20 125 -40 96 201 -140 -120 19 -128 -30 105 -104 45 191 23 -29 -108 17 -38 62 -145 -43 240 38 228 -292 130 24 -36 -123 -183 392 -158 309 56 -189 45 -240 104 -86 296 -12 -419 19 -43 -30 -378 223 -70 199 21 199 131 -130 -43 -309 112 38 247 51 -104 231 -320 -28 -287 70 126 -33 120 -27 -9 -397 132 70 185 -119 -38 16 -11 -56 244 140 145 -278 162 -378 444 -43 48 167 19 -47 -245 220 -253 268 -511 65 154 5 -26 12 391 -199 -488 70 39 318 -257 172 15 208 -34 -116 133 -124 -42 -2 156 108 -301 56 -75 134 -264 246 18 213 -321 -200 -281 -9 384 -109 137 -85 -167 31 -223 11 176 106 99 12 -146 -27 183 -60 147 311 -212 -175 27 -176 -43 159 -162 76 328 42 -51 -194 30 -67 SS 20211117T113757.8Z 7991.484697 428 1 27.96 2 60.72 203.95 118.31 47.53 0.00 1 0.00 1 0 49 5.090e-03 1.984e-03 4.533e-03 1.711e-03 1.497054e-07 6.213075e-07 2.139425e-08 4.461357e-07 2.282367e-06 223.76 -2.00 3.45 -2.00 321.86 0.00e+00 7.789799e-04 2.306440e-04 2.453371e-05 5.433771e-05 6.079114e-04 281.85 -2.00 20.00 -2.00 321.84 0.00e+00 2.496132e-04 3.122567e-04 1.280725e-06 3.031073e-05 1.073163e-03 281.85 -2.00 20.00 -2.00 321.70 0.00e+00 1.926632e-04 4.685353e-04 4.783754e-05 4.260864e-05 1.115225e-03 281.85 -2.00 20.00 -2.00 321.76 0.00e+00 2.540232e-01 2.503670e-03 1.421071e-04 2.249493e-03 6.272360e-03 229.55 2.38 0.00 1.43 10.90 318.24 0.00e+00 1.797164e-04 1.319516e-04 2.684627e-06 5.492165e-05 1.481412e-04 281.85 -2.00 20.00 -2.00 317.54 0.00e+00 2.035 0.000 303.00 329.40 4 3.5592e+00 6.4667e-03 1.9502e-02 2.3048e-03 1.9695e-02 3.2287e-02 9.2342e-03 2.1033e-03 3.3209e-04 2.1153e-02 -4.9449e-03 4.9811e-03 3.5125e-04 9.0263e-05 1.1608e-02 2.6347e-03 2.1891e-03 1.0466e-04 3.8186e-05 4.5259e-03 -1.4819e-03 1.4354e-03 4.9960e-05 6.1770e-05 3.0383e-03 1.2420e-03 1.2940e-03 1.2561e-03 6.8882e-05 1.7492e-05 1.4060e-03 2.8305e-04 4.8947e-05 2.0456e-06 6.7905e-07 1.4448e-04 8.5630e-03 -1.6392e-05 -4.4384e-03 1.5154e-01 2.9658e-03 5.3731e-04 3.9185e-01 12 9 9 12 9 1 99.94 20.28 0.21 0.00856 0.01072 35 14 1 5 0 771.747 25.58 20.02 20.28 23.07 32.5 949.44 2927 -1839 1200 -1506 -1455 -139 -672 88 -157 1050 -1199 761 819 17 279 -318 1665 -67 457 156 -214 310 -316 701 -945 277 -1176 431 316 -101 363 -614 583 -532 -295 -102 -195 458 -334 223 -409 -27 55 67 -14 -249 99 62 284 -93 165 -114 -286 -38 -183 260 -231 -123 -136 -76 54 487 212 -310 285 -172 20 -60 -178 232 1 350 56 241 -73 -181 375 -152 112 -352 59 122 72 116 -303 195 -134 160 -41 205 198 -201 151 -59 -54 -185 132 -62 -209 -90 -145 137 -160 180 161 -17 275 -278 -29 -306 -101 -344 51 60 297 231 -156 100 -227 87 -248 -159 64 -139 125 -122 128 -80 187 79 -55 109 -183 168 22 61 -79 72 -19 34 296 -110 25 -180 -74 316 -225 144 -183 -192 -21 -113 16 -31 209 -254 163 180 4 61 -74 405 -17 119 39 -49 70 -74 171 -254 79 -324 113 86 -32 134 -270 275 -266 -151 -53 -101 235 -170 110 -198 -13 27 36 -8 -144 60 38 177 -58 101 -69 -177 -25 -128 194 -177 -87 -91 -48 36 361 171 -262 241 -141 16 -44 -118 144 1 248 44 205 -67 -169 370 -159 122 -390 65 133 74 112 -266 168 -119 157 -44 231 239 -241 172 -63 -54 -193 147 -71 -253 -111 -187 184 -222 254 222 -23 335 -327 -34 -368 -128 -465 70 81 392 298 -191 119 -262 101 -303 -204 85 -187 171 -170 186 -123 287 123 -87 167 -276 250 32 90 -122 119 -34 62 564 -212 50 -347 -140 SS 20211117T114155.3Z 7991.487445 431 1 8.93 2 61.04 204.96 117.74 48.38 0.00 1 0.00 1 0 37 3.434e-03 1.437e-03 3.456e-03 1.614e-03 1.478384e-06 5.903593e-07 2.203097e-08 4.460872e-07 1.534260e-06 223.76 -2.00 3.45 -2.00 321.43 0.00e+00 -2.004858e-05 2.115896e-04 7.135983e-06 5.428123e-05 4.085981e-04 281.85 -2.00 20.00 -2.00 321.24 0.00e+00 -1.159649e-05 2.928050e-04 5.347940e-06 3.031548e-05 7.239689e-04 281.85 -2.00 20.00 -2.00 321.39 0.00e+00 3.208243e-04 4.086694e-04 2.013254e-05 4.257567e-05 7.524947e-04 281.85 -2.00 20.00 -2.00 321.33 0.00e+00 2.551548e-01 2.214056e-03 3.162828e-05 2.249418e-03 4.230298e-03 228.89 2.12 0.00 1.42 7.34 317.54 0.00e+00 7.794541e-05 1.064094e-04 3.441864e-07 5.491818e-05 1.003059e-04 281.85 -2.00 20.00 -2.00 316.88 0.00e+00 2.056 0.000 303.00 329.40 4 2.6445e+00 5.9891e-03 1.9697e-02 2.3051e-03 1.3259e-02 2.2593e-02 8.0721e-03 2.0402e-03 3.3112e-04 1.4258e-02 -7.9826e-03 4.3762e-03 1.5663e-04 8.5921e-05 7.8154e-03 4.6227e-03 1.8960e-03 1.7802e-05 3.1961e-05 3.0526e-03 -4.4917e-04 1.2904e-03 2.7489e-05 5.5670e-05 2.0571e-03 3.0526e-03 1.2185e-03 1.0317e-03 1.0973e-05 1.3543e-05 9.3925e-04 2.0448e-05 4.4934e-05 1.4283e-06 6.7197e-07 9.7407e-05 9.2090e-03 -3.8252e-05 2.6962e-01 1.3886e-01 8.7322e-04 5.3288e-04 2.6389e-01 12 9 1 12 1 1 98.06 20.29 0.20 0.00921 0.00937 19 26 1 5 0 437.785 25.68 19.99 20.29 23.16 32.6 950.29 218 909 958 -1211 1114 -834 -547 1090 138 959 -431 431 -223 -529 -591 -590 14 -416 916 -656 -80 -401 -82 256 -50 332 130 269 -1213 394 -227 -200 412 -239 -41 -154 23 9 -306 -561 229 473 240 19 402 -260 157 19 203 159 70 87 -228 -217 119 148 -69 224 -92 266 -81 -61 124 12 10 -147 -134 -369 9 16 217 -147 -350 245 61 145 -42 -46 6 -233 10 149 -38 -181 88 145 135 -26 48 188 -197 4 -127 -154 166 131 -2 -127 15 -39 -89 101 5 37 14 60 15 -158 49 -48 -105 47 179 37 153 136 36 -91 -122 12 -84 -68 -131 -25 73 -17 -137 -72 -20 67 115 -19 -49 33 66 116 -91 11 -83 74 18 -47 53 12 -54 32 142 151 -192 188 -165 -123 270 33 236 -112 115 -61 -146 -162 -171 4 -134 295 -204 -23 -110 -23 78 -17 116 44 86 -415 153 -99 -103 218 -134 -23 -90 13 5 -175 -312 133 271 133 12 254 -173 109 13 136 115 50 60 -163 -154 92 122 -58 176 -66 184 -58 -50 107 11 9 -128 -110 -290 7 12 157 -113 -306 222 59 139 -43 -50 7 -263 11 162 -41 -176 82 130 127 -26 52 215 -243 5 -145 -170 172 141 -2 -150 18 -48 -114 136 7 51 18 78 19 -186 58 -59 -131 63 246 50 201 171 45 -109 -139 14 -103 -84 -171 -33 99 -23 -197 -104 -29 101 174 -28 -73 47 93 168 -135 17 -139 127 31 -84 96 22 -95 SS 20211117T114700.6Z 7991.490979 434 1 16.42 2 61.48 206.24 116.99 49.44 0.00 1 0.00 1 0 49 8.202e-03 3.247e-03 6.641e-03 2.617e-03 -4.661065e-07 9.511481e-07 5.923254e-08 4.461230e-07 3.662417e-06 223.76 -2.00 3.45 -2.00 321.75 0.00e+00 5.959925e-04 3.512213e-04 1.269809e-05 5.432181e-05 9.768833e-04 281.85 -2.00 20.00 -2.00 321.67 0.00e+00 -4.099872e-04 4.768025e-04 3.032290e-05 3.031616e-05 1.729090e-03 281.85 -2.00 20.00 -2.00 321.61 0.00e+00 2.199126e-03 7.119414e-04 1.296851e-04 4.259353e-05 1.797297e-03 281.85 -2.00 20.00 -2.00 321.64 0.00e+00 2.496483e-01 3.678796e-03 2.079287e-04 2.249431e-03 1.011245e-02 220.14 3.48 0.00 1.45 17.55 318.04 0.00e+00 -5.659881e-05 1.943783e-04 3.022454e-06 5.492073e-05 2.383779e-04 281.85 -2.00 20.00 -2.00 317.37 0.00e+00 2.084 0.000 303.00 329.40 4 3.9338e+00 8.9526e-03 2.0021e-02 2.3048e-03 3.1676e-02 -5.0998e-03 1.2898e-02 2.4570e-03 3.3229e-04 3.4083e-02 1.4667e-02 7.1710e-03 3.7200e-04 8.9577e-05 1.8696e-02 -4.3706e-03 3.2984e-03 5.7776e-05 3.6795e-05 7.3172e-03 -7.3848e-04 2.1862e-03 6.9691e-05 6.0426e-05 4.9105e-03 8.1522e-04 4.9286e-04 1.8245e-03 8.8653e-05 1.6045e-05 2.1778e-03 9.7627e-05 7.4549e-05 2.0929e-06 6.7715e-07 2.3260e-04 8.9597e-03 -5.6476e-05 4.1552e-01 2.2648e-01 1.2927e-03 5.2469e-04 6.2477e-01 12 9 9 12 1 1 99.83 20.30 0.19 0.00896 0.00970 11 8 1 5 0 1353.527 25.68 19.98 20.30 23.40 32.5 951.82 1634 -2864 161 -2333 2945 -2715 -767 1323 -2246 3241 -51 1156 428 156 412 -2090 562 -990 768 403 1007 1032 -1280 1683 -457 1416 -841 426 -411 -687 785 -1190 1213 -825 457 -664 -584 417 -376 338 -1274 592 -103 -223 598 -602 801 -320 870 -83 220 292 -771 418 283 887 -825 -185 -496 196 264 -637 -124 -279 237 50 -215 -81 -298 272 -3 492 -80 124 398 -38 364 105 63 -406 219 -73 371 -338 -380 738 -946 395 -148 -61 111 12 0 -13 -94 -130 -203 -311 -297 196 186 -91 322 107 -252 167 222 182 -194 -596 29 -123 327 -14 538 -147 34 183 -493 364 -358 168 -39 -146 19 -376 268 -22 174 -48 -9 64 -233 61 -93 219 -86 -23 -20 118 39 -22 -68 -69 80 185 -367 20 -298 388 -435 -138 254 -473 662 -11 259 99 36 95 -523 146 -268 212 106 243 243 -312 431 -130 421 -245 116 -120 -228 301 -540 586 -427 241 -358 -313 221 -198 172 -658 297 -54 -124 348 -365 498 -204 551 -53 141 184 -492 281 204 669 -644 -137 -341 132 181 -493 -102 -241 205 43 -171 -61 -204 178 -2 361 -66 108 366 -37 364 111 69 -452 247 -80 380 -328 -344 645 -871 391 -158 -69 132 14 0 -14 -97 -137 -227 -364 -356 244 239 -123 448 149 -346 219 275 215 -229 -726 37 -163 443 -18 706 -189 42 219 -572 419 -432 214 -51 -198 26 -530 387 -33 267 -74 -14 98 -350 90 -134 320 -134 -37 -34 209 72 -42 -130 -130 149