File name: Pandora210s1_Bandung_20221117_L2Fit_fsus1c4d20220922p1-8.txt File generation date: 20260324T210736.5Z Data description: Level 2 spectral fitting results file Data file version: fsus1c4p1-8 Local principal investigator: Risyanto Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 210 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora210_OF_v4d20210929.txt Instrument calibration file used: Pandora210s1_CF_v4d20220922.txt Level 1 file used: Pandora210s1_Bandung_20221117_L1_smca1c4d20220922p1-8.txt.bz2 Full location name: Laboratory of Observation, Electronics, and Computation - Deputy of Research and Short location name: Bandung Country of location: Indonesia Location latitude [deg]: -6.8948 Location longitude [deg]: 107.5865 Location altitude [m]: 752 Local noon date: 20221117 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: data preparation 1.8 field cal First and last pixel inside fitting window: 260 404 Nominal wavelengths inside fitting window [nm]: 306.0949 306.2358 306.3768 306.5177 306.6586 306.7994 306.9403 307.0812 307.2220 307.3629 307.5037 307.6445 307.7853 307.9261 308.0669 308.2076 308.3484 308.4891 308.6299 308.7706 308.9113 309.0520 309.1927 309.3334 309.4740 309.6147 309.7553 309.8960 310.0366 310.1772 310.3178 310.4584 310.5990 310.7395 310.8801 311.0206 311.1611 311.3016 311.4421 311.5826 311.7231 311.8636 312.0041 312.1445 312.2849 312.4254 312.5658 312.7062 312.8466 312.9869 313.1273 313.2677 313.4080 313.5483 313.6886 313.8290 313.9693 314.1095 314.2498 314.3901 314.5303 314.6706 314.8108 314.9510 315.0912 315.2314 315.3716 315.5118 315.6519 315.7921 315.9322 316.0723 316.2124 316.3525 316.4926 316.6327 316.7727 316.9128 317.0528 317.1929 317.3329 317.4729 317.6129 317.7529 317.8928 318.0328 318.1728 318.3127 318.4526 318.5925 318.7324 318.8723 319.0122 319.1521 319.2919 319.4318 319.5716 319.7114 319.8512 319.9910 320.1308 320.2706 320.4103 320.5501 320.6898 320.8296 320.9693 321.1090 321.2487 321.3883 321.5280 321.6677 321.8073 321.9469 322.0866 322.2262 322.3658 322.5054 322.6449 322.7845 322.9240 323.0636 323.2031 323.3426 323.4821 323.6216 323.7611 323.9006 324.0400 324.1795 324.3189 324.4583 324.5977 324.7371 324.8765 325.0159 325.1553 325.2946 325.4339 325.5733 325.7126 325.8519 325.9912 326.1305 326.2697 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20221117T004244.2Z 8356.029678 281 1 49.99 2 57.50 108.08 31.28 318.89 0.00 1 0.00 1 0 33 1.065e-02 3.845e-03 8.797e-03 3.379e-03 -1.683017e-06 1.285276e-06 1.277652e-07 3.514900e-07 5.038998e-06 227.81 -2.00 3.06 -2.00 321.90 0.00e+00 1.645680e-03 4.748153e-04 6.685303e-05 2.591555e-05 1.320879e-03 289.56 -2.00 20.00 -2.00 321.80 0.00e+00 6.146821e-04 6.351765e-04 4.452351e-05 2.353312e-05 2.272485e-03 289.56 -2.00 20.00 -2.00 321.70 0.00e+00 2.736872e-03 9.860569e-04 1.974103e-04 1.028062e-05 2.413127e-03 289.56 -2.00 20.00 -2.00 321.76 0.00e+00 2.181592e-01 5.044551e-03 3.861500e-04 3.763284e-03 1.358406e-02 219.87 5.43 0.00 0.95 23.38 318.20 0.00e+00 7.191648e-04 3.015941e-04 2.190105e-05 1.268038e-05 3.612818e-04 289.56 -2.00 20.00 -2.00 316.95 0.00e+00 1.855 0.000 303.00 329.40 4 6.1376e+00 1.2094e-02 1.6560e-02 1.8193e-03 4.2703e-02 2.0825e-03 1.8093e-02 2.8033e-03 3.4549e-04 4.5887e-02 1.5545e-02 9.7945e-03 1.0574e-03 1.3561e-04 2.5285e-02 -9.6430e-03 4.1687e-03 7.8098e-04 4.1171e-05 9.6620e-03 -4.1905e-04 2.8943e-03 2.1576e-04 5.4498e-05 6.3299e-03 1.8541e-04 -8.7308e-03 2.8381e-03 3.2334e-04 2.1132e-05 3.8769e-03 -2.2864e-05 1.0722e-04 6.6774e-06 9.1184e-07 3.3383e-04 4.2459e-03 0.0000e+00 1.6841e+00 3.2679e-01 3.5670e-03 4.3023e-04 8.5715e-01 12 8 8 10 0 0 99.93 18.66 0.03 0.00425 0.00407 22 5 1 5 0 2272.130 21.06 15.01 18.66 31.68 12.5 954.08 -5597 2375 2592 3437 -2275 -1189 -574 -360 -332 1537 -715 -2000 2016 -1931 2984 -2205 1264 -2352 2388 367 -110 801 2101 721 -1044 2800 -439 303 -1452 2431 -1635 175 17 -575 -1054 217 -194 -35 -450 55 -145 -179 133 -892 1016 -411 350 -703 702 685 785 -473 -15 1067 18 84 184 83 -457 210 -366 439 -596 599 -574 170 227 121 -629 -266 536 -25 244 -1297 208 -223 185 -340 713 -436 48 43 -41 -365 -150 -605 -597 -34 -286 829 282 574 -362 -110 -146 311 223 70 -283 -238 -57 343 67 173 422 -300 306 -406 302 -73 119 -425 -230 -20 337 337 -219 396 -56 41 -581 -32 -567 267 2 69 39 7 -278 123 -93 -208 191 78 293 -248 206 -366 140 -94 153 100 128 -115 -76 -667 285 324 424 -309 -179 -96 -67 -67 312 -152 -446 459 -446 679 -542 316 -630 625 96 -27 184 477 175 -273 750 -124 80 -401 723 -584 72 8 -291 -531 111 -100 -18 -238 28 -72 -88 65 -469 553 -238 210 -437 434 430 488 -294 -9 690 13 61 137 60 -317 137 -240 306 -453 481 -478 138 176 90 -426 -166 325 -16 180 -1081 178 -203 176 -346 762 -489 54 48 -43 -354 -138 -523 -515 -32 -281 887 329 685 -419 -119 -149 319 233 79 -336 -295 -74 462 94 243 583 -409 384 -476 350 -86 143 -550 -312 -27 450 436 -269 476 -65 46 -674 -39 -741 346 3 94 56 10 -437 196 -146 -338 299 118 435 -370 319 -589 241 -174 290 199 258 -232 -152 SS 20221117T012845.5Z 8356.061638 315 1 49.58 2 46.69 109.59 39.48 306.51 0.00 1 0.00 1 0 33 4.252e-03 3.234e-03 2.513e-03 1.399e-03 -1.399106e-06 5.413070e-07 4.796302e-08 3.514020e-07 2.020527e-06 227.81 -2.00 3.06 -2.00 321.30 0.00e+00 5.497953e-04 1.869852e-04 2.185112e-05 2.581413e-05 5.328029e-04 289.56 -2.00 20.00 -2.00 321.03 0.00e+00 9.686337e-05 2.647660e-04 1.878197e-05 2.349379e-05 9.116032e-04 289.56 -2.00 20.00 -2.00 321.27 0.00e+00 -1.154830e-03 3.560571e-04 6.096330e-06 1.040252e-05 9.639595e-04 289.56 -2.00 20.00 -2.00 321.18 0.00e+00 1.782661e-01 1.974498e-03 1.272715e-04 3.764264e-03 5.380134e-03 235.87 2.76 0.00 1.18 9.33 317.08 0.00e+00 1.339603e-04 9.462004e-05 2.239079e-05 1.260276e-05 1.423349e-04 289.56 -2.00 20.00 -2.00 315.84 0.00e+00 1.455 0.000 303.00 329.40 4 5.1619e+00 5.8366e-03 1.2917e-02 1.8166e-03 1.7109e-02 4.5725e-02 7.5608e-03 1.3694e-03 3.2390e-04 1.8271e-02 -1.1186e-02 3.9574e-03 3.8168e-04 1.1836e-04 1.0155e-02 4.7271e-04 1.4247e-03 1.7646e-04 2.6579e-05 3.7164e-03 1.9372e-03 1.0735e-03 5.8173e-05 4.4210e-05 2.4874e-03 7.7462e-04 -4.8887e-03 1.2149e-03 7.2392e-05 2.0487e-05 2.1223e-03 2.1576e-06 4.3018e-05 2.2002e-06 8.7557e-07 1.3367e-04 2.7662e-03 0.0000e+00 8.1828e-01 1.5005e-01 3.5332e-03 5.5801e-04 3.8457e-01 12 8 8 10 0 0 100.00 18.67 0.36 0.00277 0.00278 65 14 1 5 0 762.650 21.06 15.01 18.67 33.41 12.6 966.77 -705 103 -120 415 893 -4 16 -136 -372 -253 -357 88 347 -370 271 198 522 -346 -343 -467 282 -167 1007 211 444 -100 -45 193 122 -107 -9 247 14 -2 -59 -3 52 135 224 48 -388 -236 -74 -228 -87 81 191 74 247 -111 76 -157 -24 -292 -5 -119 -330 17 21 -326 6 -115 -2 81 -137 -8 83 248 18 -78 -269 -452 -397 4031 -184 -327 -254 -9 -88 -32 24 110 61 -18 244 -209 -260 -273 -118 -75 7 -50 -25 -193 -94 28 -239 -220 -291 -82 159 109 54 230 140 121 -42 12 109 56 -170 -231 81 -74 237 141 125 -169 -35 59 8 -93 -225 -111 -120 74 -169 133 -135 162 186 -37 -111 -187 163 -81 59 0 13 137 31 -19 46 12 -129 -139 22 -27 90 197 -1 4 -41 -119 -82 -119 30 120 -130 94 70 194 -134 -135 -180 100 -55 324 72 157 -38 -17 69 44 -44 -4 135 8 -1 -37 -2 33 84 139 32 -248 -146 -46 -148 -59 53 129 50 171 -78 53 -108 -17 -211 -4 -97 -279 14 16 -249 4 -85 -2 72 -125 -7 71 194 14 -55 -186 -333 -328 3216 -165 -312 -254 -10 -100 -38 28 130 68 -19 226 -180 -243 -246 -118 -82 8 -60 -29 -209 -96 28 -254 -254 -351 -103 208 148 76 334 200 163 -52 13 119 62 -200 -293 108 -99 313 181 151 -194 -38 62 9 -106 -271 -138 -153 96 -228 189 -201 245 287 -57 -167 -273 232 -116 87 0 20 229 55 -35 85 22 -238 SS 20221117T021610.3Z 8356.094563 343 1 48.56 2 35.72 113.08 49.18 298.48 0.00 1 0.00 1 0 49 9.038e-03 5.346e-03 7.174e-03 4.191e-03 -9.265493e-06 1.641522e-06 1.603759e-07 3.513816e-07 4.299034e-06 227.81 -2.00 3.06 -2.00 321.16 0.00e+00 2.704980e-03 5.666236e-04 9.581186e-05 2.579887e-05 1.131572e-03 289.56 -2.00 20.00 -2.00 320.91 0.00e+00 -3.150789e-04 7.942466e-04 3.206172e-05 2.347329e-05 1.945025e-03 289.56 -2.00 20.00 -2.00 321.16 0.00e+00 1.794594e-03 1.095535e-03 1.218991e-04 1.040502e-05 2.049298e-03 289.56 -2.00 20.00 -2.00 321.05 0.00e+00 1.513434e-01 5.408634e-03 3.329680e-04 3.764640e-03 1.133683e-02 204.30 8.35 0.00 1.48 19.81 316.73 0.00e+00 4.038709e-04 2.719211e-04 4.904551e-05 1.259472e-05 3.022893e-04 289.56 -2.00 20.00 -2.00 315.60 0.00e+00 1.231 0.000 303.00 329.40 4 7.1053e+00 1.3479e-02 1.1005e-02 1.8173e-03 3.6260e-02 1.6384e-02 1.7674e-02 2.3445e-03 3.2309e-04 3.8583e-02 3.5841e-02 1.0285e-02 1.0726e-03 1.1679e-04 2.1449e-02 -2.0866e-02 3.9901e-03 3.5640e-04 2.6788e-05 7.7293e-03 -1.7022e-03 3.1577e-03 3.2835e-04 4.2405e-05 5.3020e-03 1.4106e-04 -3.0003e-02 3.6999e-03 3.7848e-04 2.3964e-05 5.2561e-03 1.7733e-04 1.3088e-04 6.3329e-06 8.6762e-07 2.8407e-04 2.7888e-03 0.0000e+00 2.5704e+00 4.6856e-01 2.1000e-02 6.0603e-04 8.4806e-01 12 9 8 11 8 0 99.96 18.71 0.55 0.00279 0.00414 14 3 1 5 0 3468.170 21.06 15.00 18.71 31.73 12.5 953.52 728 764 1603 -1473 2843 253 1800 -1486 1320 -722 -1838 2814 -2384 201 -2006 -337 -2794 -730 -1003 2702 91 1637 917 -1231 1371 364 1012 -1084 2232 -187 233 -1928 785 579 420 -404 210 -343 -165 786 -411 699 -908 447 -298 10 -88 1265 123 -576 -842 -281 -691 923 395 -192 261 -159 -258 -771 106 -1369 -92 -602 244 -165 433 -3 437 -332 597 220 -707 1688 -539 191 -380 1060 -279 162 343 853 -291 -347 -255 -209 -549 -175 613 -64 1086 -195 424 -217 455 -597 -1056 -531 -404 -247 706 354 -234 35 -150 522 -469 7 -799 -119 -216 -274 52 439 132 110 253 -735 -123 372 -88 -739 161 -706 499 -56 433 -336 864 273 -129 -101 53 23 -111 102 -308 -76 149 463 183 74 -238 -159 -173 155 175 379 -352 671 67 514 -476 439 -248 -648 972 -876 73 -736 -124 -1097 -289 -405 1033 34 572 318 -451 509 143 400 -415 844 -80 114 -1069 479 376 280 -276 143 -231 -110 502 -267 437 -575 291 -204 7 -62 901 89 -425 -617 -211 -527 722 317 -163 227 -133 -206 -580 78 -1091 -80 -543 224 -150 388 -2 328 -230 400 156 -565 1454 -510 189 -396 1117 -316 190 406 990 -322 -367 -246 -186 -485 -163 622 -71 1238 -229 496 -240 473 -613 -1150 -622 -494 -302 887 463 -320 49 -206 669 -582 8 -881 -132 -252 -343 69 582 172 139 303 -839 -134 406 -98 -840 189 -868 618 -70 567 -467 1238 401 -195 -151 76 32 -155 142 -446 -118 237 779 327 137 -448 -298 -320 SS 20221117T022444.1Z 8356.100510 349 1 49.70 2 33.77 114.05 51.01 297.37 0.00 1 0.00 1 0 49 1.499e-03 1.212e-03 1.278e-03 8.878e-04 -6.198238e-07 3.522365e-07 3.216367e-08 3.513312e-07 7.115568e-07 227.81 -2.00 3.06 -2.00 320.59 0.00e+00 5.596125e-04 1.146421e-04 2.551229e-05 2.576635e-05 1.884020e-04 289.56 -2.00 20.00 -2.00 320.23 0.00e+00 1.681220e-04 1.697484e-04 3.714306e-06 2.350297e-05 3.233797e-04 289.56 -2.00 20.00 -2.00 320.76 0.00e+00 3.935121e-05 2.100404e-04 2.056270e-05 1.034995e-05 3.399250e-04 289.56 -2.00 20.00 -2.00 320.50 0.00e+00 1.449866e-01 1.154505e-03 8.904359e-05 3.765313e-03 1.882780e-03 230.46 1.99 0.00 1.45 3.29 315.92 0.00e+00 7.512977e-05 4.919157e-05 9.094469e-06 1.256659e-05 5.007710e-05 289.56 -2.00 20.00 -2.00 314.81 0.00e+00 1.202 0.000 303.00 329.40 4 4.8774e+00 3.4881e-03 1.0657e-02 1.8161e-03 6.0333e-03 2.5448e-02 4.2644e-03 1.1743e-03 3.1565e-04 6.4114e-03 -1.7498e-03 2.3050e-03 3.0638e-04 1.0512e-04 3.5766e-03 -5.9986e-04 8.0518e-04 8.2094e-05 2.2303e-05 1.2736e-03 1.4554e-06 6.3338e-04 8.9932e-05 3.8296e-05 8.8347e-04 1.3529e-03 -2.9412e-03 7.5429e-04 6.9924e-05 2.1447e-05 8.7510e-04 9.3352e-05 2.6706e-05 1.4760e-06 8.3032e-07 4.7113e-05 2.8281e-03 0.0000e+00 8.5000e-01 9.8550e-02 5.4762e-03 6.7149e-04 1.4434e-01 11 8 0 10 0 0 99.91 18.72 0.26 0.00283 0.00354 47 10 1 5 0 1057.390 21.06 15.00 18.72 31.77 12.6 955.33 74 -404 -106 -162 431 41 384 -203 192 -144 -51 -138 -176 -97 109 319 -31 -36 59 34 -164 0 270 95 27 234 -22 78 122 -11 93 163 -199 34 -17 -157 -134 152 -23 -50 -118 108 -109 -240 -173 -178 47 222 -49 -10 -41 129 -83 99 13 -49 0 -7 104 -85 -74 -47 -78 57 -159 107 365 187 35 -154 -120 -80 -45 791 -79 -86 -211 87 -48 -123 -27 208 70 -43 54 -298 -72 -89 86 165 186 -100 -52 -51 55 -34 -46 -85 -142 -130 136 6 -55 69 86 89 -66 -15 34 -48 -12 -175 -127 23 90 95 31 -59 -24 -64 23 -208 23 73 60 -7 -26 75 31 4 78 -9 -24 -61 33 -6 -68 49 18 106 81 19 -21 -90 -60 21 -125 -34 -51 136 14 146 -85 77 -58 -23 -58 -75 -42 51 153 -14 -17 28 16 -78 0 115 42 12 112 -11 36 56 -6 50 104 -144 26 -13 -125 -107 119 -18 -37 -84 75 -75 -173 -131 -140 38 183 -41 -8 -34 106 -69 86 11 -44 0 -6 90 -69 -60 -40 -69 54 -154 102 332 171 28 -116 -88 -61 -38 686 -74 -86 -219 97 -53 -140 -31 237 81 -46 52 -289 -69 -83 87 184 223 -113 -62 -57 57 -34 -50 -101 -176 -155 167 7 -73 94 114 111 -82 -17 37 -53 -14 -221 -157 28 111 123 38 -68 -26 -68 25 -238 28 89 76 -9 -34 97 42 6 110 -12 -33 -81 44 -8 -93 71 28 163 133 33 -37 -154 -100 SS 20221117T022950.4Z 8356.104055 352 1 49.91 2 32.61 114.70 52.10 296.74 0.00 1 0.00 1 0 33 2.940e-03 1.856e-03 2.786e-03 1.788e-03 -2.250052e-06 7.026742e-07 3.918478e-08 3.513336e-07 1.395717e-06 227.81 -2.00 3.06 -2.00 320.79 0.00e+00 1.268761e-03 2.363040e-04 2.667197e-05 2.578191e-05 3.698630e-04 289.56 -2.00 20.00 -2.00 320.42 0.00e+00 -1.425214e-04 3.417448e-04 3.714985e-06 2.347433e-05 6.347745e-04 289.56 -2.00 20.00 -2.00 320.89 0.00e+00 -1.054650e-04 4.302937e-04 3.672942e-05 1.044535e-05 6.665851e-04 289.56 -2.00 20.00 -2.00 320.70 0.00e+00 1.478107e-01 2.330339e-03 1.469458e-04 3.765041e-03 3.689127e-03 227.88 3.94 0.00 1.41 6.44 316.30 0.00e+00 1.061268e-05 1.059485e-04 3.921926e-06 1.258144e-05 9.820861e-05 289.56 -2.00 20.00 -2.00 315.17 0.00e+00 1.187 0.000 303.00 329.40 4 5.9723e+00 6.8613e-03 1.0520e-02 1.8174e-03 1.1833e-02 3.4154e-02 8.5486e-03 1.2133e-03 3.2005e-04 1.2563e-02 6.5417e-03 4.6641e-03 3.9965e-04 1.1090e-04 7.0170e-03 -4.0822e-03 1.6439e-03 1.0327e-04 2.4432e-05 2.4974e-03 -2.4614e-03 1.3158e-03 7.8956e-05 4.0779e-05 1.7352e-03 4.6078e-04 -1.3713e-02 1.5793e-03 1.4246e-04 2.3363e-05 1.7614e-03 7.5447e-05 5.4217e-05 2.8950e-06 8.3963e-07 9.2425e-05 2.6905e-03 0.0000e+00 1.1990e+00 2.0175e-01 7.5447e-03 7.0232e-04 2.8446e-01 12 8 8 10 0 0 99.97 18.72 0.31 0.00269 0.00327 25 5 1 5 0 1996.350 21.06 15.00 18.72 32.06 12.6 957.67 -672 -214 22 -273 773 1335 -392 -441 -24 -547 -483 539 -1084 354 418 -308 -427 465 -60 -313 134 675 200 363 289 -103 337 503 724 320 211 254 -248 194 -47 -208 -210 130 -67 -10 -154 -39 -147 25 -40 -112 88 397 -118 -158 37 -299 440 -35 -235 44 260 -25 -19 -42 -320 -97 -332 -306 40 2 54 318 -208 128 -359 61 129 243 -93 79 -159 -64 105 -86 92 239 -49 -196 -38 -277 -170 -216 244 298 305 8 -39 -107 95 -17 -333 57 85 -25 201 -226 145 195 69 54 -26 62 7 -102 -124 -133 32 -51 179 91 36 -98 39 230 -375 -104 -264 134 -234 -75 200 52 -131 186 162 -252 38 -178 138 -69 -20 -84 131 -26 40 38 115 -126 18 -168 -58 6 -74 212 396 -130 -159 -9 -212 -190 214 -445 145 169 -128 -185 206 -27 -139 55 253 81 138 115 -43 141 218 318 143 108 152 -169 140 -35 -157 -158 96 -49 -7 -104 -25 -96 17 -29 -83 68 310 -93 -127 29 -234 345 -29 -205 41 246 -23 -15 -32 -244 -78 -303 -298 39 2 50 274 -162 91 -249 45 105 219 -91 81 -170 -67 117 -100 108 277 -54 -214 -38 -254 -154 -207 255 341 344 9 -43 -121 101 -18 -372 69 98 -31 251 -293 195 269 93 68 -33 72 7 -116 -148 -172 40 -64 223 110 45 -115 44 248 -414 -121 -323 168 -300 -98 270 68 -179 260 231 -359 53 -240 181 -92 -28 -124 205 -43 70 64 197 -217 31 SS 20221117T023512.0Z 8356.107778 355 1 49.02 2 31.41 115.44 53.27 296.12 0.00 1 0.00 1 0 33 1.510e-02 1.177e-02 3.643e-03 2.353e-03 -1.621393e-06 9.182887e-07 1.621264e-07 3.513460e-07 7.164022e-06 227.81 -2.00 3.06 -2.00 320.84 0.00e+00 -1.835591e-05 3.040295e-04 2.084413e-05 2.578845e-05 1.891999e-03 289.56 -2.00 20.00 -2.00 320.50 0.00e+00 -6.416377e-06 4.528387e-04 7.598702e-05 2.346698e-05 3.264091e-03 289.56 -2.00 20.00 -2.00 320.94 0.00e+00 -5.154973e-03 5.468748e-04 9.673008e-05 1.048698e-05 3.422187e-03 289.56 -2.00 20.00 -2.00 320.75 0.00e+00 1.700450e-01 3.138431e-03 2.384432e-04 3.764967e-03 1.890384e-02 248.46 4.84 0.00 1.29 33.08 316.38 0.00e+00 -1.657298e-05 1.391309e-04 3.519800e-05 1.257830e-05 5.044187e-04 289.56 -2.00 20.00 -2.00 315.17 0.00e+00 1.171 0.000 303.00 329.40 4 6.4570e+00 1.1155e-02 1.0763e-02 1.8170e-03 6.0821e-02 1.2894e-01 1.2813e-02 1.3273e-03 3.1701e-04 6.4340e-02 -5.3679e-02 6.5224e-03 4.3439e-04 1.1020e-04 3.5816e-02 1.4096e-02 2.1587e-03 1.8400e-04 2.4170e-05 1.2745e-02 6.5971e-03 1.7333e-03 1.1114e-04 4.0195e-05 8.9009e-03 2.8368e-04 3.0760e-03 2.1597e-03 9.2548e-05 2.3100e-05 9.0325e-03 -4.8008e-04 7.4715e-05 4.8124e-06 8.5057e-07 4.7464e-04 2.7620e-03 0.0000e+00 4.2001e+00 2.6428e-01 3.4263e-03 6.4362e-04 1.4430e+00 12 9 8 11 8 0 98.08 18.72 0.18 0.00276 -0.00090 14 3 1 5 0 3500.900 21.06 15.00 18.72 32.22 12.6 958.51 -1457 -2285 -1312 -1300 99 -1098 -106 582 -542 1499 -180 1743 -385 967 186 728 -900 -99 -210 552 651 -45 425 -298 359 -603 -28 -352 797 -69 574 161 726 592 686 350 44 745 -413 117 -283 -174 -864 -375 -651 -58 39 298 -51 -145 -85 -451 204 -228 -309 -650 -568 -478 -420 -695 -465 -941 -247 -274 239 45 99 60 -472 -472 -1900 -1675 -1666 15631 -1114 -388 -763 57 125 -15 148 658 587 -160 -30 -307 -503 -882 -352 6 -73 -732 -696 -109 502 -380 -802 -824 -305 49 717 595 70 529 85 461 218 226 -191 -26 -443 -759 -198 452 688 364 230 -418 -333 352 -16 -793 -278 -262 277 -1 55 -96 -206 396 24 21 -637 32 217 17 -60 -313 -250 332 85 199 129 -76 -47 -373 -638 -362 -368 28 -345 -35 206 -207 568 -70 683 -156 391 79 312 -390 -44 -94 252 274 -18 163 -119 147 -261 -12 -145 331 -32 304 96 488 423 503 262 33 545 -302 82 -191 -114 -565 -255 -464 -43 30 232 -40 -115 -67 -350 158 -185 -266 -568 -509 -428 -343 -535 -353 -763 -222 -253 226 42 91 52 -365 -348 -1371 -1269 -1344 12278 -1070 -392 -777 62 144 -18 180 787 664 -166 -29 -280 -450 -837 -364 6 -85 -875 -800 -117 531 -396 -885 -943 -364 61 922 793 94 719 114 601 262 261 -211 -30 -524 -929 -255 587 878 451 282 -484 -370 375 -18 -913 -333 -325 349 -2 70 -130 -290 566 35 30 -906 44 293 23 -84 -471 -388 547 142 346 226 -133 -81