File name: Pandora134s1_BristolPA_20210901_L2Fit_fsus1c2d20210612p1-8.txt File generation date: 20251126T235358.2Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Luke Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 134 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora134_OF_v4d20200325.txt Instrument calibration file used: Pandora134s1_CF_v2d20210612.txt Level 1 file used: Pandora134s1_BristolPA_20210901_L1_smca1c2d20210612p1-8.txt Full location name: Franklin D. Roosevelt Middle School; Bristol, Pennsylvania Short location name: BristolPA Country of location: United States Location latitude [deg]: 40.1074 Location longitude [deg]: -74.8824 Location altitude [m]: 10 Local noon date: 20210901 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 241 385 Nominal wavelengths inside fitting window [nm]: 306.0769 306.2182 306.3595 306.5008 306.6420 306.7833 306.9246 307.0658 307.2070 307.3482 307.4894 307.6306 307.7718 307.9130 308.0541 308.1953 308.3364 308.4775 308.6187 308.7598 308.9008 309.0419 309.1830 309.3240 309.4651 309.6061 309.7471 309.8881 310.0291 310.1701 310.3111 310.4521 310.5930 310.7340 310.8749 311.0158 311.1567 311.2976 311.4385 311.5793 311.7202 311.8610 312.0019 312.1427 312.2835 312.4243 312.5651 312.7059 312.8466 312.9874 313.1281 313.2689 313.4096 313.5503 313.6910 313.8317 313.9724 314.1130 314.2537 314.3943 314.5349 314.6755 314.8161 314.9567 315.0973 315.2379 315.3784 315.5190 315.6595 315.8000 315.9406 316.0811 316.2215 316.3620 316.5025 316.6429 316.7834 316.9238 317.0642 317.2046 317.3450 317.4854 317.6258 317.7661 317.9065 318.0468 318.1871 318.3275 318.4678 318.6081 318.7483 318.8886 319.0289 319.1691 319.3093 319.4495 319.5898 319.7300 319.8701 320.0103 320.1505 320.2906 320.4308 320.5709 320.7110 320.8511 320.9912 321.1313 321.2713 321.4114 321.5514 321.6915 321.8315 321.9715 322.1115 322.2515 322.3915 322.5314 322.6714 322.8113 322.9513 323.0912 323.2311 323.3710 323.5109 323.6507 323.7906 323.9304 324.0703 324.2101 324.3499 324.4897 324.6295 324.7693 324.9090 325.0488 325.1885 325.3283 325.4680 325.6077 325.7474 325.8871 326.0267 326.1664 326.3060 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210901T181853.3Z 7914.763116 509 1 51.52 2 36.69 214.29 70.07 286.79 0.00 1 0.00 1 0 49 5.634e-03 3.053e-03 6.304e-03 3.225e-03 -2.450929e-06 1.219045e-06 4.956454e-08 3.581529e-07 2.612152e-06 230.40 -2.00 3.49 -2.00 321.47 0.00e+00 1.619733e-03 4.274958e-04 2.304596e-05 1.185936e-05 6.852794e-04 289.55 -2.00 20.00 -2.00 321.35 0.00e+00 7.842887e-04 6.010752e-04 3.743685e-06 2.385774e-05 1.186941e-03 289.55 -2.00 20.00 -2.00 321.38 0.00e+00 1.693302e-04 8.308538e-04 5.431172e-05 1.786890e-05 1.252987e-03 289.55 -2.00 20.00 -2.00 321.36 0.00e+00 1.685082e-01 4.391332e-03 1.824285e-04 2.329209e-03 6.813790e-03 228.04 6.43 0.00 3.46 11.87 317.32 0.00e+00 -6.009168e-05 2.250435e-04 3.595189e-05 2.479421e-05 1.799286e-04 289.55 -2.00 20.00 -2.00 316.07 0.00e+00 1.246 0.000 303.00 329.40 4 5.8207e+00 1.2065e-02 1.2128e-02 2.0255e-03 2.1909e-02 4.2029e-02 1.6262e-02 1.5622e-03 6.1978e-04 2.3187e-02 5.3844e-03 8.6682e-03 4.9633e-04 2.2438e-04 1.2884e-02 -6.1702e-03 3.1906e-03 1.6661e-04 3.9511e-05 4.7267e-03 -5.4174e-05 2.4749e-03 3.8868e-05 4.5124e-05 3.2497e-03 8.3997e-04 -1.0653e-02 2.9370e-03 2.0214e-04 4.8264e-05 3.0184e-03 4.0604e-04 9.5673e-05 3.6608e-06 7.5110e-07 1.6523e-04 -3.2279e-03 1.1888e-04 1.2858e+00 3.6258e-01 8.0940e-03 6.5976e-04 5.3567e-01 12 8 8 10 0 0 99.99 21.68 0.32 -0.00323 -0.00013 44 8 1 5 0 1170.541 27.15 20.00 21.68 30.84 10.6 1017.98 1637 -413 -1597 -410 408 338 362 -23 -970 138 162 1479 -129 278 -1636 1929 -683 1439 -898 -710 -433 -405 627 7 -221 440 -288 1723 -1658 1902 -69 -144 87 -841 192 100 110 -84 556 674 -880 77 -761 102 68 -473 494 122 767 -94 375 -450 234 -867 -140 -377 87 -447 -160 -139 -235 -404 -245 -266 -164 93 249 124 9 1104 120 618 77 469 -69 28 55 543 74 317 53 330 -156 -93 -489 -44 -7 -175 91 -172 166 49 -135 -76 -254 1 32 -454 -58 158 -100 80 56 124 187 -80 327 -182 185 -217 -762 -265 22 -34 257 -27 31 -216 15 -114 -145 -267 -107 314 -88 224 -64 100 -97 445 -243 136 38 229 -260 237 -301 211 -262 248 197 142 69 -254 -212 281 -79 -320 -79 79 72 86 -6 -274 39 47 439 -40 87 -515 598 -228 492 -324 -251 -143 -125 187 2 -73 154 -103 564 -560 687 -29 -72 49 -508 118 63 69 -53 346 406 -517 44 -433 60 43 -308 331 84 531 -66 262 -311 161 -625 -107 -308 73 -367 -119 -96 -161 -301 -204 -237 -149 83 214 100 7 727 77 424 59 395 -63 27 55 569 82 367 62 382 -172 -95 -459 -38 -6 -161 91 -187 194 59 -155 -82 -257 1 35 -529 -69 196 -129 106 78 177 262 -106 400 -208 204 -246 -914 -341 29 -45 338 -35 38 -252 16 -122 -160 -315 -131 396 -112 289 -87 143 -142 662 -370 205 56 329 -368 337 -449 332 -442 440 370 273 135 -495 -405 SS 20210901T183319.0Z 7914.773136 515 1 49.96 2 38.35 219.49 72.61 288.75 0.00 1 0.00 1 0 49 7.846e-03 3.997e-03 8.623e-03 4.369e-03 -4.740156e-06 1.650379e-06 1.104208e-07 3.581538e-07 3.644985e-06 230.40 -2.00 3.49 -2.00 321.47 0.00e+00 2.007986e-03 5.789869e-04 6.796163e-05 1.185561e-05 9.560150e-04 289.55 -2.00 20.00 -2.00 321.34 0.00e+00 -3.721398e-05 8.127198e-04 2.036837e-05 2.386293e-05 1.653635e-03 289.55 -2.00 20.00 -2.00 321.37 0.00e+00 -5.369495e-04 1.126656e-03 7.520341e-05 1.786010e-05 1.744868e-03 289.55 -2.00 20.00 -2.00 321.35 0.00e+00 1.751892e-01 5.970511e-03 2.527187e-04 2.329230e-03 9.483038e-03 228.55 8.41 0.00 3.33 16.51 317.34 0.00e+00 3.167458e-04 3.073867e-04 5.806631e-05 2.479518e-05 2.507090e-04 289.55 -2.00 20.00 -2.00 316.10 0.00e+00 1.274 0.000 303.00 329.40 4 6.3629e+00 1.6417e-02 1.2414e-02 2.0251e-03 3.0448e-02 5.9221e-02 2.2166e-02 2.1961e-03 6.1958e-04 3.2244e-02 1.2963e-02 1.1771e-02 7.0174e-04 2.2496e-04 1.7924e-02 -8.0143e-03 4.3746e-03 2.6306e-04 3.9832e-05 6.6015e-03 -3.5328e-03 3.3642e-03 2.2294e-04 4.5302e-05 4.5254e-03 4.7478e-04 -1.9135e-02 3.8941e-03 2.8369e-04 4.8291e-05 4.2871e-03 4.5669e-04 1.2979e-04 4.6223e-06 7.5403e-07 2.3029e-04 -2.9311e-03 1.3927e-04 1.6071e+00 4.8520e-01 1.4757e-02 6.3055e-04 7.3839e-01 12 8 8 10 0 0 99.97 21.68 0.35 -0.00293 0.00055 20 4 1 5 0 2497.738 27.15 19.99 21.68 31.25 10.5 1020.21 1001 -1783 637 -329 -916 554 2442 1924 -579 650 -2745 1709 1534 -638 -1031 1106 1175 -3023 -676 846 2146 -1422 1205 592 -22 306 1873 634 -1402 -1479 359 -894 -428 -698 975 -226 92 -1118 -369 681 -252 -633 -1423 -647 496 196 -105 -431 1178 458 -497 884 428 71 501 289 420 -421 -337 451 -685 -96 70 -211 -259 701 174 -228 194 -259 -371 -54 -419 -50 -190 228 777 -78 274 123 463 -11 -219 -98 -462 -146 5 -566 -555 619 -135 479 -73 121 585 146 -709 -304 -189 -185 143 271 128 -220 -265 659 -268 -187 -742 -185 194 -33 -127 -241 -404 110 216 -11 13 511 134 -116 109 -246 340 -230 279 -122 324 -74 190 -23 -77 56 114 -239 503 -138 -48 144 113 94 -103 -476 140 170 -339 123 -63 -177 117 564 492 -161 181 -813 499 463 -199 -319 342 380 -1063 -238 290 681 -437 355 183 -7 107 654 209 -474 -549 152 -447 -240 -417 590 -142 57 -703 -229 408 -147 -361 -813 -385 308 127 -71 -297 809 322 -348 603 294 51 381 235 352 -344 -250 312 -472 -72 58 -188 -236 626 150 -183 141 -173 -241 -37 -326 -42 -173 216 764 -82 306 142 543 -13 -243 -100 -434 -127 4 -525 -561 671 -159 575 -85 132 590 147 -766 -352 -226 -231 183 362 179 -315 -373 870 -331 -214 -830 -210 231 -42 -170 -325 -536 140 262 -12 15 546 148 -137 134 -311 430 -300 377 -174 475 -110 287 -35 -113 80 161 -341 740 -218 -80 256 211 181 -200 -922 266 SS 20210901T184301.9Z 7914.779883 518 1 50.92 2 39.58 222.78 74.31 290.07 0.00 1 0.00 1 0 49 1.148e-03 6.557e-04 1.185e-03 6.134e-04 1.571182e-07 2.324758e-07 2.210875e-08 3.581398e-07 5.315161e-07 230.40 -2.00 3.49 -2.00 321.47 0.00e+00 3.918427e-04 8.137700e-05 1.430963e-05 1.182575e-05 1.395463e-04 289.55 -2.00 20.00 -2.00 321.41 0.00e+00 -1.460181e-04 1.151387e-04 5.439129e-06 2.386502e-05 2.415813e-04 289.55 -2.00 20.00 -2.00 321.38 0.00e+00 1.718583e-04 1.566105e-04 2.154173e-05 1.797764e-05 2.552229e-04 289.55 -2.00 20.00 -2.00 321.37 0.00e+00 1.671002e-01 8.443182e-04 7.142390e-05 2.329192e-03 1.389653e-03 233.03 1.26 0.00 3.50 2.42 317.30 0.00e+00 8.339200e-05 4.272202e-05 2.123247e-05 2.479528e-05 3.668464e-05 289.55 -2.00 20.00 -2.00 316.06 0.00e+00 1.296 0.000 303.00 329.40 4 2.9036e+00 2.4108e-03 1.2605e-02 2.0259e-03 4.4555e-03 2.0654e-02 3.2044e-03 1.4158e-03 6.1838e-04 4.7268e-03 -3.9799e-03 1.6865e-03 1.8332e-04 2.2260e-04 2.6236e-03 3.6772e-04 6.0803e-04 5.3205e-05 4.0204e-05 9.6346e-04 1.7763e-04 4.6549e-04 5.2500e-05 4.5659e-05 6.6210e-04 1.4814e-02 1.5099e-03 5.5064e-04 5.2291e-05 4.6540e-05 5.7781e-04 4.6390e-04 1.7899e-05 1.2884e-06 7.2591e-07 3.3613e-05 -2.9975e-03 9.7447e-05 4.5488e-01 6.7742e-02 2.6235e-03 6.3691e-04 1.0790e-01 10 0 0 10 0 0 99.98 21.68 0.18 -0.00300 0.00054 604 107 1 5 0 84.247 27.26 19.99 21.68 31.35 10.5 1020.82 549 16 219 -105 -80 -89 -291 -191 94 -341 347 -240 265 -171 171 116 106 -129 90 11 187 -153 201 48 1 250 -83 77 15 -18 -176 70 -84 -32 -144 91 -191 165 -164 98 -52 -107 -66 115 -110 -65 21 12 -25 8 105 42 30 -1 30 -29 24 -92 16 -8 -146 -59 43 -32 128 -8 27 -46 109 -7 105 -8 81 -12 56 -90 74 6 14 -29 65 90 10 35 -71 -126 -124 -76 2 37 100 38 -50 70 -10 103 27 -132 -112 -17 -66 25 19 76 -8 52 -52 51 -72 -48 -59 -83 -44 -38 28 -57 14 42 -5 36 22 -38 -30 -50 115 -33 65 16 -36 62 38 -36 -4 13 22 -28 -16 41 30 -17 92 -12 0 -30 -62 97 3 44 -20 -16 -19 -71 -51 27 -98 102 -73 83 -54 53 37 35 -45 32 4 60 -46 64 16 0 94 -32 27 5 -7 -73 34 -47 -19 -88 57 -119 102 -101 58 -30 -65 -39 72 -66 -41 14 8 -17 6 71 31 22 -1 22 -23 20 -74 12 -6 -104 -46 34 -27 113 -7 22 -38 82 -5 69 -6 65 -11 54 -82 70 6 15 -33 75 102 11 34 -69 -112 -110 -73 2 38 114 45 -56 79 -11 108 30 -148 -130 -21 -83 33 26 107 -12 68 -61 60 -82 -56 -74 -103 -58 -50 35 -70 18 51 -6 40 25 -46 -39 -66 152 -45 85 22 -52 90 57 -53 -6 18 30 -39 -23 63 50 -31 176 -24 1 -60 -119 SS 20210901T184830.8Z 7914.783690 522 1 50.83 2 40.30 224.57 75.26 290.83 0.00 1 0.00 1 0 49 2.994e-03 1.218e-03 1.978e-03 9.465e-04 4.857105e-07 3.559398e-07 1.800116e-08 3.581773e-07 1.386612e-06 230.39 -2.00 3.49 -2.00 321.62 0.00e+00 6.055536e-04 1.267636e-04 1.051689e-05 1.181036e-05 3.635689e-04 289.55 -2.00 20.00 -2.00 321.54 0.00e+00 -2.125578e-04 1.767638e-04 6.491273e-06 2.384884e-05 6.297707e-04 289.55 -2.00 20.00 -2.00 321.50 0.00e+00 4.284596e-04 2.487050e-04 4.587506e-05 1.774866e-05 6.659972e-04 289.55 -2.00 20.00 -2.00 321.51 0.00e+00 1.673114e-01 1.319441e-03 1.102031e-04 2.329332e-03 3.627380e-03 230.00 1.95 0.00 3.50 6.31 317.59 0.00e+00 7.721435e-05 6.982787e-05 6.607858e-06 2.479701e-05 9.573030e-05 289.55 -2.00 20.00 -2.00 316.32 0.00e+00 1.310 0.000 303.00 329.40 4 3.2979e+00 3.6177e-03 1.2742e-02 2.0261e-03 1.1615e-02 1.0521e-02 4.9503e-03 1.4362e-03 6.2749e-04 1.2336e-02 1.7245e-04 2.6169e-03 2.1864e-04 2.3017e-04 6.8367e-03 -3.1062e-03 9.6524e-04 8.0953e-05 4.1645e-05 2.5215e-03 1.9968e-03 7.3992e-04 3.2489e-05 4.6700e-05 1.7291e-03 9.8525e-03 1.2968e-03 8.7824e-04 8.6200e-05 4.4987e-05 1.4666e-03 5.1174e-04 2.8025e-05 1.6987e-06 7.5524e-07 8.7812e-05 -2.9413e-03 1.2297e-04 4.7354e-01 1.0561e-01 2.9349e-03 5.7238e-04 2.7981e-01 11 8 0 10 0 0 99.99 21.68 0.22 -0.00294 0.00096 802 142 1 5 0 63.364 27.15 20.00 21.68 31.26 10.6 1020.30 1156 -837 1037 -1318 1112 -348 796 -325 532 -785 454 -566 -141 -545 240 -97 305 -276 192 91 31 -133 -46 543 37 143 -241 216 -92 121 -549 196 -336 218 -362 287 -325 133 -213 164 -21 221 21 217 12 72 158 159 -50 115 30 -139 207 -56 0 -112 126 -223 202 -173 189 -175 -101 -265 113 -99 165 -108 193 38 -56 57 112 35 2 -115 27 -41 -113 1 98 138 -56 48 -329 36 -63 161 -182 187 -67 69 -116 206 -145 40 -66 70 -70 43 -119 -7 -39 172 28 63 -16 14 -13 -117 -3 20 56 -26 103 -68 13 -97 81 13 105 -196 -43 -152 136 -167 107 -71 52 44 136 -70 -39 -57 -11 -42 -10 1 11 54 23 74 21 -42 -64 182 -148 186 -234 194 -68 173 -79 137 -207 124 -160 -41 -161 69 -28 94 -89 64 30 9 -38 -13 159 12 47 -82 67 -29 42 -224 92 -181 124 -213 171 -194 79 -129 95 -11 119 11 122 7 45 102 104 -33 77 20 -93 138 -39 0 -88 102 -179 145 -115 126 -126 -82 -231 100 -87 138 -84 136 24 -35 38 84 29 2 -106 26 -43 -125 1 115 159 -61 49 -302 31 -54 144 -180 203 -77 82 -134 220 -144 40 -71 81 -85 54 -152 -9 -54 248 40 83 -19 16 -14 -133 -4 26 75 -36 137 -88 16 -114 90 14 116 -233 -54 -196 176 -221 145 -103 78 67 212 -108 -59 -83 -16 -61 -15 2 19 98 43 145 41 -83 -123 SS 20210901T185351.5Z 7914.787401 525 1 49.37 2 41.03 226.26 76.19 291.56 0.00 1 0.00 1 0 49 9.185e-03 4.569e-03 9.535e-03 4.602e-03 -4.629601e-06 1.737108e-06 1.224963e-07 3.581623e-07 4.243545e-06 230.39 -2.00 3.49 -2.00 321.54 0.00e+00 2.719229e-03 6.196221e-04 7.456455e-05 1.180199e-05 1.115557e-03 289.55 -2.00 20.00 -2.00 321.43 0.00e+00 2.389629e-04 8.548081e-04 3.602506e-05 2.385201e-05 1.932258e-03 289.55 -2.00 20.00 -2.00 321.43 0.00e+00 2.338850e-03 1.244245e-03 1.987284e-04 1.768289e-05 2.043084e-03 289.55 -2.00 20.00 -2.00 321.43 0.00e+00 1.669545e-01 5.969739e-03 4.750532e-04 2.329232e-03 1.112972e-02 204.84 8.34 0.00 3.54 19.36 317.42 0.00e+00 -1.713851e-04 3.348540e-04 8.290237e-05 2.480010e-05 2.937677e-04 289.55 -2.00 20.00 -2.00 316.25 0.00e+00 1.324 0.000 303.00 329.40 4 6.4300e+00 1.4480e-02 1.3037e-02 2.0264e-03 3.5604e-02 1.7595e-05 1.9762e-02 3.2079e-03 6.2834e-04 3.7840e-02 3.6242e-02 1.1300e-02 1.1176e-03 2.3142e-04 2.0991e-02 -1.6874e-02 4.5711e-03 2.6200e-04 4.2293e-05 7.7584e-03 -9.7070e-04 3.5907e-03 2.2560e-04 4.6630e-05 5.3038e-03 4.1910e-04 -1.1296e-02 4.1576e-03 3.6394e-04 4.6585e-05 4.5115e-03 3.9316e-04 1.3731e-04 5.8902e-06 7.5062e-07 2.6883e-04 -3.6237e-03 6.6922e-05 1.6065e+00 5.0373e-01 1.7026e-02 5.6046e-04 8.4682e-01 12 8 8 10 0 0 99.66 21.68 0.25 -0.00362 -0.00062 15 3 1 5 0 3290.902 27.15 20.00 21.68 31.26 10.6 1020.20 -886 3264 -4648 1395 547 1891 -995 -2049 1289 343 -324 678 1421 -1115 -3162 2035 -2918 133 780 1186 5 17 -195 755 861 1229 870 1667 1955 1059 -806 -57 -1007 -324 769 524 -503 -1 -685 509 -1325 418 -728 84 -180 -1085 1318 -303 726 710 -328 -471 515 -274 256 -317 414 -454 411 -651 210 -226 -754 -408 -231 235 -37 314 -46 313 118 265 67 897 -70 -456 -269 524 516 307 -281 -240 469 -344 -606 -585 -259 142 618 -48 282 167 -422 190 149 8 -638 -80 -539 -281 -111 844 547 -492 538 -171 563 -446 -518 -75 -543 -164 -6 220 917 468 31 -136 -308 -377 -536 -691 -96 144 -191 194 431 -296 104 35 13 -295 270 316 -208 -383 346 -142 -122 493 179 -7 -278 -278 213 -141 548 -873 244 98 367 -222 -510 333 91 -89 189 406 -331 -947 593 -933 43 261 390 2 5 -55 223 269 410 295 523 615 372 -332 -27 -553 -189 455 318 -307 -1 -416 297 -763 230 -403 49 -110 -699 861 -205 492 487 -226 -320 348 -193 192 -254 343 -367 299 -449 142 -167 -627 -359 -208 208 -31 248 -33 206 76 182 52 751 -64 -434 -265 547 569 353 -329 -278 514 -351 -566 -507 -224 131 619 -53 331 200 -490 205 151 8 -691 -93 -651 -351 -144 1122 764 -708 753 -227 689 -513 -579 -85 -655 -211 -8 298 1208 599 38 -159 -345 -407 -601 -826 -120 182 -245 253 586 -427 153 52 20 -451 401 458 -296 -548 516 -226 -206 878 336 -13 -545 -543 407 SS 20210901T190216.5Z 7914.793247 531 1 4.69 2 42.22 228.84 77.63 292.73 0.00 1 0.00 1 0 33 5.380e-03 3.634e-03 4.267e-03 2.905e-03 3.092627e-07 1.117212e-06 3.650240e-08 3.580596e-07 2.488040e-06 230.39 -2.00 3.49 -2.00 320.63 0.00e+00 4.675770e-04 3.630205e-04 1.091299e-05 1.215572e-05 6.534021e-04 289.55 -2.00 20.00 -2.00 320.20 0.00e+00 1.242741e-04 5.375322e-04 1.186839e-05 2.433643e-05 1.131109e-03 289.55 -2.00 20.00 -2.00 320.79 0.00e+00 4.933606e-04 6.606398e-04 1.997545e-05 1.797398e-05 1.196492e-03 289.55 -2.00 20.00 -2.00 320.54 0.00e+00 1.791652e-01 3.673492e-03 8.922055e-05 2.328471e-03 6.515671e-03 238.40 5.25 0.00 3.22 11.34 316.06 0.00e+00 1.158054e-04 1.573737e-04 3.646895e-05 2.477724e-05 1.722184e-04 289.55 -2.00 20.00 -2.00 314.93 0.00e+00 1.349 0.000 303.00 329.40 4 4.1414e+00 1.1815e-02 1.3121e-02 2.0080e-03 2.0848e-02 4.0347e-02 1.4123e-02 1.5834e-03 5.8326e-04 2.2156e-02 -1.4040e-02 7.3735e-03 2.1304e-04 1.8634e-04 1.2280e-02 2.9139e-03 2.6355e-03 4.6102e-05 3.1139e-05 4.5388e-03 3.2407e-04 2.0403e-03 6.2868e-05 4.4519e-05 3.1056e-03 3.9394e-03 2.0258e-03 2.1725e-03 3.8550e-05 3.9544e-05 2.6202e-03 -2.4738e-04 8.2512e-05 1.4556e-06 6.9503e-07 1.5637e-04 1.7982e-03 1.1278e-04 1.1707e+00 2.9990e-01 1.2063e-03 8.2823e-04 4.9710e-01 12 9 9 12 1 1 67.17 21.68 0.28 0.00180 -0.00009 4 10 1 5 0 902.460 27.15 20.00 21.68 31.14 10.6 1019.14 -1208 1893 -848 74 -987 521 -228 286 -1425 218 501 566 586 -874 556 138 -136 -437 1037 -401 1477 -746 432 -1054 1139 -1416 465 361 728 -1026 815 -373 348 -779 -395 -81 1075 -617 362 -52 -345 229 151 -821 144 178 -184 562 -133 148 -175 970 -1197 720 -545 74 320 16 -631 395 -746 768 -30 377 -422 -131 -280 -508 522 -139 -588 75 -174 -229 482 -1 185 -25 611 46 -37 -163 381 -162 439 -496 170 -595 133 -170 530 -167 136 81 174 -176 -32 50 278 -14 -273 -36 -164 164 -153 274 -476 153 29 -250 -353 209 -184 69 -124 89 -186 48 -231 651 -23 -85 -113 -38 391 7 39 -155 -44 -3 248 -440 404 47 2 -36 172 35 52 -276 238 -208 227 -422 201 -328 541 -256 22 -295 167 -80 109 -579 89 207 240 254 -389 242 61 -63 -210 502 -194 668 -326 183 -469 523 -695 228 167 337 -519 456 -237 239 -563 -291 -61 794 -460 268 -38 -245 159 105 -593 108 137 -145 447 -108 120 -141 770 -968 590 -471 67 295 15 -535 318 -600 649 -28 360 -412 -127 -265 -458 436 -109 -456 60 -152 -214 472 -1 191 -27 683 53 -43 -189 425 -172 437 -471 161 -590 140 -189 616 -198 157 90 184 -186 -35 58 331 -17 -340 -46 -216 218 -203 348 -577 175 32 -287 -422 261 -236 89 -158 111 -226 56 -263 720 -26 -101 -138 -47 487 9 51 -210 -61 -4 348 -618 557 63 3 -48 237 51 78 -431 384 -343 376 -700 327