File name: Pandora134s1_BristolPA_20211204_L2Fit_fsus1c2d20210612p1-8.txt File generation date: 20251127T001843.3Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 134 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora134_OF_v6d20200325.txt Instrument calibration file used: Pandora134s1_CF_v2d20210612.txt Level 1 file used: Pandora134s1_BristolPA_20211204_L1_smca1c2d20210612p1-8.txt Full location name: Franklin D. Roosevelt Middle School; Bristol, Pennsylvania Short location name: BristolPA Country of location: United States Location latitude [deg]: 40.1074 Location longitude [deg]: -74.8824 Location altitude [m]: 10 Local noon date: 20211204 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 241 385 Nominal wavelengths inside fitting window [nm]: 306.0769 306.2182 306.3595 306.5008 306.6420 306.7833 306.9246 307.0658 307.2070 307.3482 307.4894 307.6306 307.7718 307.9130 308.0541 308.1953 308.3364 308.4775 308.6187 308.7598 308.9008 309.0419 309.1830 309.3240 309.4651 309.6061 309.7471 309.8881 310.0291 310.1701 310.3111 310.4521 310.5930 310.7340 310.8749 311.0158 311.1567 311.2976 311.4385 311.5793 311.7202 311.8610 312.0019 312.1427 312.2835 312.4243 312.5651 312.7059 312.8466 312.9874 313.1281 313.2689 313.4096 313.5503 313.6910 313.8317 313.9724 314.1130 314.2537 314.3943 314.5349 314.6755 314.8161 314.9567 315.0973 315.2379 315.3784 315.5190 315.6595 315.8000 315.9406 316.0811 316.2215 316.3620 316.5025 316.6429 316.7834 316.9238 317.0642 317.2046 317.3450 317.4854 317.6258 317.7661 317.9065 318.0468 318.1871 318.3275 318.4678 318.6081 318.7483 318.8886 319.0289 319.1691 319.3093 319.4495 319.5898 319.7300 319.8701 320.0103 320.1505 320.2906 320.4308 320.5709 320.7110 320.8511 320.9912 321.1313 321.2713 321.4114 321.5514 321.6915 321.8315 321.9715 322.1115 322.2515 322.3915 322.5314 322.6714 322.8113 322.9513 323.0912 323.2311 323.3710 323.5109 323.6507 323.7906 323.9304 324.0703 324.2101 324.3499 324.4897 324.6295 324.7693 324.9090 325.0488 325.1885 325.3283 325.4680 325.6077 325.7474 325.8871 326.0267 326.1664 326.3060 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20211204T155549.7Z 8008.663770 172 1 51.01 2 63.69 166.04 67.63 161.54 0.00 1 0.00 1 0 49 5.665e-03 2.102e-03 6.648e-03 1.680e-03 1.649891e-06 6.030649e-07 2.455536e-08 3.499690e-07 2.542394e-06 223.12 -2.00 3.49 -2.00 322.37 0.00e+00 3.358508e-04 2.329681e-04 8.571017e-06 1.140115e-05 6.661903e-04 279.05 -2.00 20.00 -2.00 322.49 0.00e+00 3.355035e-04 3.103934e-04 6.693243e-06 2.382592e-05 1.194458e-03 279.05 -2.00 20.00 -2.00 322.06 0.00e+00 5.136306e-04 5.163033e-04 7.715186e-05 1.656499e-05 1.228869e-03 279.05 -2.00 20.00 -2.00 322.22 0.00e+00 2.784756e-01 2.661574e-03 2.161916e-04 2.329653e-03 6.968972e-03 225.65 2.25 0.00 2.08 12.01 319.16 0.00e+00 -1.034430e-05 1.798672e-04 2.495634e-05 2.372031e-05 1.765613e-04 279.05 -2.00 20.00 -2.00 318.09 0.00e+00 2.243 0.000 303.00 329.40 4 3.8917e+00 6.1781e-03 2.1791e-02 2.0328e-03 2.1814e-02 2.7057e-02 9.8380e-03 2.4908e-03 6.7695e-04 2.3406e-02 -1.5771e-03 5.2003e-03 4.2734e-04 2.7747e-04 1.2761e-02 -6.0679e-04 2.5787e-03 9.9552e-05 7.9709e-05 5.1574e-03 -2.3021e-04 1.6440e-03 5.1389e-05 6.4250e-05 3.6020e-03 1.8761e-03 -2.6982e-03 1.2970e-03 6.0295e-05 3.3769e-05 1.3110e-03 2.7736e-04 4.9736e-05 1.7884e-06 7.4234e-07 1.6327e-04 5.3982e-03 7.4103e-05 -5.5902e-02 1.4220e-01 1.2996e-03 3.1611e-04 4.1119e-01 12 8 8 10 0 0 99.85 21.65 0.15 0.00540 0.00751 69 12 1 5 0 739.071 27.15 20.00 21.65 11.61 13.8 948.73 141 -444 -701 362 -1281 537 -550 -1284 88 -903 356 131 2353 -538 1762 490 2115 -1644 510 112 33 -219 838 -46 1110 -688 -70 -1883 935 -1423 318 376 -129 -164 -426 -486 -193 -99 -230 653 -89 -4 -111 169 -297 64 -569 848 -203 646 -380 1183 -1272 -30 -49 572 498 -198 -751 -79 -728 497 87 39 28 138 72 -38 631 221 472 -259 328 -35 372 -554 -111 -199 155 -211 30 -187 298 -111 68 -291 -119 -42 111 18 -100 123 -7 126 -300 19 -143 -84 -136 50 -124 152 -36 171 -34 204 -144 204 -88 96 9 -15 -97 124 37 65 39 -75 -82 56 -17 -24 -39 -108 105 -42 55 -199 51 -11 282 -250 67 -184 94 62 19 -197 -91 260 -28 37 36 -35 -39 9 -32 -53 27 -102 48 -57 -152 11 -120 49 19 345 -82 261 76 347 -296 93 20 6 -35 135 -8 211 -145 -15 -382 187 -324 84 118 -46 -63 -171 -199 -79 -41 -95 262 -35 -2 -44 72 -136 31 -287 431 -107 343 -201 606 -665 -16 -28 360 330 -129 -451 -45 -420 312 62 29 22 104 52 -25 380 124 263 -159 227 -27 308 -484 -101 -192 156 -222 32 -196 296 -103 58 -234 -98 -37 108 19 -116 145 -7 133 -299 19 -151 -94 -158 61 -157 201 -50 246 -48 277 -183 243 -102 115 12 -20 -134 172 49 85 50 -91 -95 63 -21 -30 -53 -149 147 -61 82 -315 83 -18 467 -412 108 -286 143 96 30 -340 -167 502 -57 78 76 -75 -82 SS 20211204T160054.0Z 8008.667292 175 1 5.28 2 63.47 167.33 67.36 162.71 0.00 1 0.00 1 0 49 1.467e-02 7.114e-03 2.101e-02 7.785e-03 2.050305e-06 2.818617e-06 7.675263e-08 3.499104e-07 6.505030e-06 223.12 -2.00 3.49 -2.00 321.70 0.00e+00 1.602039e-03 1.032275e-03 2.072483e-05 1.141512e-05 1.717766e-03 279.05 -2.00 20.00 -2.00 321.51 0.00e+00 -1.027936e-03 1.411027e-03 3.404838e-05 2.399066e-05 3.089269e-03 279.05 -2.00 20.00 -2.00 321.56 0.00e+00 2.642193e-03 2.097519e-03 2.245816e-04 1.668367e-05 3.183166e-03 279.05 -2.00 20.00 -2.00 321.57 0.00e+00 2.672844e-01 1.087156e-02 6.314821e-04 2.329526e-03 1.802779e-02 219.26 9.57 0.00 2.12 31.11 318.05 0.00e+00 4.061835e-06 6.337234e-04 1.731708e-04 2.371740e-05 4.553917e-04 279.05 -2.00 20.00 -2.00 317.04 0.00e+00 2.226 0.000 303.00 329.40 4 4.7105e+00 2.6234e-02 2.1754e-02 2.0228e-03 5.6277e-02 1.6492e-03 3.8228e-02 4.6811e-03 6.5461e-04 6.0602e-02 2.5396e-02 2.0918e-02 1.6289e-03 2.5373e-04 3.2977e-02 1.9947e-03 1.0067e-02 4.8629e-04 6.1368e-05 1.3020e-02 -1.3448e-02 6.8352e-03 1.9658e-04 5.6232e-05 9.2007e-03 8.3392e-04 1.3476e-03 5.0385e-03 1.6240e-04 2.7655e-05 3.1416e-03 -5.4251e-04 2.2016e-04 3.9268e-06 6.9903e-07 4.1884e-04 5.7096e-03 -7.0511e-05 -1.5130e-01 6.4049e-01 2.4074e-03 6.8256e-04 1.0574e+00 12 9 9 12 1 1 999.00 21.65 0.21 0.00571 0.00157 1 4 1 5 0 2548.561 27.15 20.00 21.65 11.78 13.8 950.27 3642 -768 476 -5065 5216 732 -5707 -2117 2733 2914 2231 -1281 32 2260 -569 -649 -3466 -2029 -2222 1329 -907 491 1651 -2174 413 -1393 2189 1829 -3576 -554 2444 2072 348 40 -599 2094 2 1095 -2416 56 -2251 1200 652 -1248 123 1477 721 2025 -981 -787 188 844 -1889 -1382 1206 593 1589 -1233 1708 -2516 22 -929 1467 -930 9 308 -315 -375 943 -56 1181 -1274 -374 358 924 -11 -678 452 184 -1295 -86 -53 -462 644 -1605 1645 -665 -51 607 -97 -762 16 -192 -460 -627 636 631 -45 -198 455 902 -623 888 -212 -51 229 448 -301 1011 -235 -261 39 838 -707 580 17 562 -744 589 -394 -671 -905 233 -14 659 -115 -563 -215 -578 326 770 -282 -457 361 -751 314 341 -241 -189 38 -173 198 -10 396 -112 360 -87 56 -617 603 100 -949 -383 512 564 452 -278 7 500 -128 -150 -876 -535 -603 346 -227 115 385 -564 113 -418 649 511 -1058 -176 874 864 164 20 -312 1086 1 573 -1304 29 -1180 605 336 -685 71 876 446 1267 -638 -519 121 535 -1224 -926 843 443 1224 -952 1206 -1760 15 -699 1185 -802 8 264 -262 -294 677 -38 796 -938 -302 310 851 -10 -671 466 197 -1445 -96 -58 -492 645 -1530 1466 -611 -50 633 -109 -910 19 -226 -514 -666 664 695 -52 -236 558 1134 -823 1209 -298 -70 306 568 -366 1197 -285 -330 51 1133 -960 769 22 706 -916 695 -458 -812 -1156 307 -19 897 -160 -814 -321 -883 501 1193 -437 -694 532 -1098 459 517 -383 -316 67 -315 369 -19 745 -210 SS 20211204T162344.4Z 8008.683152 184 1 42.31 2 62.73 173.19 66.34 168.05 0.00 1 0.00 1 0 65 6.800e-03 1.902e-03 6.959e-03 1.931e-03 -7.104597e-09 6.940623e-07 5.702730e-08 3.499512e-07 3.050606e-06 223.12 -2.00 3.49 -2.00 322.22 0.00e+00 3.494055e-04 2.651386e-04 3.291377e-05 1.141543e-05 7.988631e-04 279.05 -2.00 20.00 -2.00 322.26 0.00e+00 3.548171e-04 3.549652e-04 1.730588e-05 2.385368e-05 1.435027e-03 279.05 -2.00 20.00 -2.00 321.95 0.00e+00 7.467705e-04 5.744042e-04 9.166513e-05 1.655648e-05 1.475217e-03 279.05 -2.00 20.00 -2.00 322.07 0.00e+00 2.692904e-01 2.960973e-03 2.903378e-04 2.329666e-03 8.355022e-03 224.07 2.59 0.00 2.17 14.41 318.89 0.00e+00 2.189322e-04 1.931061e-04 7.954794e-05 2.371178e-05 2.110604e-04 279.05 -2.00 20.00 -2.00 317.84 0.00e+00 2.171 0.000 303.00 329.40 4 4.2138e+00 6.9352e-03 2.1100e-02 2.0305e-03 2.6123e-02 1.9070e-02 1.0822e-02 3.0001e-03 6.7204e-04 2.8077e-02 -2.1657e-03 5.7566e-03 5.4284e-04 2.7112e-04 1.5285e-02 -1.0332e-04 2.7908e-03 1.4857e-04 7.2962e-05 6.0740e-03 2.3122e-04 1.8248e-03 1.0450e-04 6.1827e-05 4.2910e-03 1.4760e-03 -1.7274e-03 1.4632e-03 9.3589e-05 3.2462e-05 1.5544e-03 5.6828e-04 5.6821e-05 1.7301e-06 7.4219e-07 1.9736e-04 5.2822e-03 1.6065e-04 2.9477e-01 1.6542e-01 2.2904e-03 3.8243e-04 4.9494e-01 12 9 9 12 1 1 99.98 21.65 0.18 0.00528 0.00962 35 8 1 5 0 1170.605 27.15 20.00 21.65 12.75 13.8 957.50 4813 -1210 1835 -1048 -310 1669 1791 -851 1085 -837 -394 -484 503 -671 59 64 718 -613 -752 -72 -1019 363 1143 1318 1021 1328 -436 -607 -1640 -1259 115 -348 -215 949 -39 -28 -339 239 -236 849 -806 -512 -360 133 -210 -106 -246 329 596 362 -126 -640 -839 690 10 155 414 44 60 -666 -423 -85 -19 25 -222 125 135 271 74 17 267 -133 -112 423 -12 -12 -222 -98 -136 301 68 16 224 27 83 -35 -184 220 80 -18 9 173 29 113 -105 206 -109 -386 -302 47 -71 202 -30 -63 -163 125 -52 -33 -127 43 -187 -147 160 12 46 -13 50 -220 -143 78 -55 51 115 -52 155 82 24 -78 74 -76 219 -13 -85 -1 164 -132 -43 -62 -96 269 35 39 -20 -34 -126 337 -99 152 -88 -27 165 202 -112 152 -124 -60 -78 83 -114 10 11 132 -120 -153 -14 -193 65 202 251 213 300 -102 -132 -367 -311 33 -118 -83 386 -17 -12 -148 104 -104 362 -345 -215 -153 60 -101 -54 -131 178 329 203 -70 -352 -463 392 6 103 286 30 38 -398 -254 -56 -14 19 -177 98 101 188 46 10 156 -85 -80 331 -10 -11 -207 -96 -140 321 74 17 229 25 73 -29 -155 199 80 -19 10 206 34 122 -106 205 -117 -440 -356 57 -90 267 -42 -91 -231 169 -65 -39 -149 52 -236 -197 221 17 62 -18 63 -268 -166 89 -66 64 154 -72 216 116 36 -121 117 -124 357 -21 -134 -2 246 -202 -68 -106 -173 509 69 80 -42 -71 -257 SS 20211204T162903.4Z 8008.686844 188 1 51.72 2 62.62 174.57 66.15 169.31 0.00 1 0.00 1 0 49 1.512e-02 3.852e-03 1.554e-02 4.075e-03 -2.225247e-06 1.466566e-06 6.887476e-08 3.499599e-07 6.785840e-06 223.12 -2.00 3.49 -2.00 322.36 0.00e+00 1.405890e-03 5.651447e-04 7.560857e-05 1.140941e-05 1.779138e-03 279.05 -2.00 20.00 -2.00 322.48 0.00e+00 -8.900250e-05 7.532325e-04 7.906456e-06 2.381104e-05 3.193617e-03 279.05 -2.00 20.00 -2.00 322.04 0.00e+00 -4.626127e-04 1.255615e-03 5.699699e-05 1.659729e-05 3.279222e-03 279.05 -2.00 20.00 -2.00 322.20 0.00e+00 2.671622e-01 6.295476e-03 2.644508e-04 2.329590e-03 1.859422e-02 219.14 5.46 0.00 2.20 32.22 319.06 0.00e+00 -1.370592e-04 4.251481e-04 8.364817e-05 2.371665e-05 4.659275e-04 279.05 -2.00 20.00 -2.00 318.01 0.00e+00 2.163 0.000 303.00 329.40 4 5.4935e+00 1.4066e-02 2.1022e-02 2.0331e-03 5.8431e-02 3.5669e-02 2.2530e-02 2.6857e-03 6.7534e-04 6.2551e-02 8.6396e-03 1.2103e-02 1.0577e-03 2.7526e-04 3.4059e-02 -9.9024e-03 5.9911e-03 4.1978e-04 7.5996e-05 1.3399e-02 1.3424e-03 3.9071e-03 1.6476e-04 6.2601e-05 9.4588e-03 4.2229e-04 -5.7816e-03 3.2129e-03 1.3573e-04 3.5671e-05 3.4546e-03 6.9384e-04 1.2091e-04 3.7717e-06 7.5341e-07 4.3961e-04 5.0615e-03 1.8523e-04 -1.6534e-01 3.5398e-01 8.0910e-03 3.1268e-04 1.0853e+00 12 9 9 12 1 1 99.97 21.65 0.38 0.00506 0.01036 14 3 1 5 0 3447.110 27.15 20.00 21.65 13.09 13.8 959.57 8791 1102 8276 -4191 -347 -5349 -2881 -2021 1615 -2184 1694 1337 -1391 944 853 780 1682 -3636 1971 -671 1815 -2338 1827 1062 417 -1075 -901 -431 -1433 1334 -961 1839 -289 1458 -900 499 -53 1305 -780 1736 -62 243 -678 -745 -1227 -746 -245 560 -431 -84 -1816 1092 -944 945 -532 192 549 -686 -574 -398 664 -721 397 341 502 -224 840 506 187 -329 250 -1014 361 1020 353 -269 -880 228 -210 347 498 143 81 113 -768 -384 -387 -256 195 196 -123 -26 159 299 44 -22 -56 182 -518 -501 -267 502 -149 42 -83 328 69 253 -625 -23 -91 -78 -332 -143 549 -134 252 -356 -41 178 494 33 -49 -102 292 -353 471 17 -184 1 163 -152 25 157 -178 -221 21 -86 109 406 -243 -64 61 -288 212 564 84 616 -347 -29 -531 -320 -252 213 -309 240 199 -219 149 132 126 287 -694 370 -127 316 -401 303 191 82 -234 -199 -89 -300 303 -262 584 -107 567 -371 208 -22 539 -329 703 -25 97 -276 -324 -574 -366 -125 291 -231 -45 -984 565 -498 514 -317 123 368 -452 -347 -228 378 -460 282 258 387 -171 606 337 113 -186 139 -626 250 773 293 -234 -805 220 -215 366 530 151 81 104 -660 -310 -316 -228 190 210 -143 -31 181 316 43 -21 -59 204 -606 -612 -338 665 -209 61 -118 445 87 299 -728 -28 -115 -105 -461 -197 734 -174 315 -429 -46 198 576 42 -65 -139 403 -504 699 26 -298 1 270 -250 40 243 -270 -339 33 -147 199 787 -500 -137 130 -620 450 SS 20211204T184532.1Z 8008.781621 274 1 51.15 2 68.01 208.82 68.83 201.57 0.00 1 0.00 1 0 49 2.176e-02 3.300e-03 2.081e-02 3.341e-03 2.980005e-06 1.201314e-06 1.437845e-07 3.500469e-07 9.562751e-06 223.11 -2.00 3.49 -2.00 322.88 0.00e+00 3.387716e-04 4.820041e-04 7.151830e-05 1.132139e-05 2.518265e-03 279.04 -2.00 20.00 -2.00 323.21 0.00e+00 6.540722e-04 6.320014e-04 3.790940e-05 2.382445e-05 4.617217e-03 279.04 -2.00 20.00 -2.00 322.45 0.00e+00 -1.653308e-03 1.173628e-03 9.649365e-05 1.629568e-05 4.718783e-03 279.04 -2.00 20.00 -2.00 322.71 0.00e+00 3.298661e-01 5.960192e-03 5.610072e-04 2.329360e-03 2.683244e-02 228.49 4.20 0.00 1.76 45.96 320.10 0.00e+00 6.697777e-04 4.673364e-04 2.809140e-05 2.368752e-05 6.912882e-04 279.04 -2.00 20.00 -2.00 319.02 0.00e+00 2.647 0.000 303.00 329.40 4 4.4477e+00 1.3044e-02 2.5719e-02 2.0360e-03 8.3422e-02 3.8860e-02 2.2669e-02 3.2963e-03 6.9259e-04 8.9603e-02 -1.1978e-02 1.1780e-02 1.4131e-03 2.9483e-04 4.8566e-02 7.2424e-03 6.6254e-03 1.2743e-03 1.0853e-04 1.9232e-02 -2.6110e-03 3.9010e-03 1.1228e-04 7.8040e-05 1.4500e-02 7.0143e-04 -3.0192e-03 2.4399e-03 2.5117e-04 3.0547e-05 2.9278e-03 3.4678e-04 1.0370e-04 7.4633e-06 7.5220e-07 6.3029e-04 4.8517e-03 1.0633e-04 4.0080e-02 2.5653e-01 2.5416e-03 3.0531e-04 1.4034e+00 12 8 8 10 0 0 99.99 21.66 0.22 0.00485 0.00750 42 7 1 5 0 1217.619 27.26 20.00 21.66 15.21 13.9 974.53 -8721 15805 -3577 1693 285 -936 8174 -3196 -628 -3032 5357 -2221 1091 -3179 2402 -4047 5955 -1373 1491 -3816 -301 -2345 -3575 -1283 3285 819 423 993 -442 -1051 1316 -103 1213 -525 330 477 -1093 1108 -1369 -317 -211 -774 -54 1343 146 979 -1209 1078 -1026 1441 -687 902 -1068 -43 -274 1520 426 339 -481 -668 -147 28 -122 -451 -177 7 402 -611 1322 76 589 -112 176 -185 -166 -501 407 -254 -144 -445 243 -26 628 -381 -289 -489 -23 -275 -451 407 72 106 -32 76 -74 476 227 5 -635 123 -279 175 -57 459 -226 306 79 76 84 -177 -152 -208 -57 219 12 265 176 -172 100 -193 460 -497 355 -418 -232 -17 217 141 -76 12 223 -166 -51 -483 281 -156 -120 58 108 58 147 -134 -158 222 -46 -366 589 -166 75 14 -52 487 -243 -51 -266 457 -214 106 -327 232 -431 620 -163 179 -478 -34 -262 -414 -160 433 122 64 141 -64 -172 249 -24 314 -149 97 144 -336 335 -428 -97 -64 -235 -17 444 52 369 -491 439 -437 611 -293 371 -451 -19 -131 779 233 183 -242 -322 -72 15 -75 -297 -119 5 250 -352 674 37 284 -60 107 -127 -124 -395 333 -223 -134 -431 237 -25 570 -323 -226 -362 -17 -229 -419 413 80 121 -35 78 -70 441 226 6 -713 144 -342 225 -79 655 -321 413 100 90 98 -212 -192 -280 -79 302 16 345 219 -206 115 -216 543 -643 482 -594 -336 -25 340 232 -130 20 389 -287 -85 -781 442 -249 -203 104 208 120 324 -305 -367 517 -106 SS 20211204T185039.2Z 8008.785176 277 1 51.02 2 68.49 209.98 69.19 202.70 0.00 1 0.00 1 0 49 1.451e-02 2.264e-03 1.947e-02 2.874e-03 2.108781e-06 1.035390e-06 5.612440e-08 3.500592e-07 6.436379e-06 223.11 -2.00 3.49 -2.00 322.95 0.00e+00 -6.209048e-04 4.177533e-04 4.909360e-05 1.130982e-05 1.682585e-03 279.04 -2.00 20.00 -2.00 323.30 0.00e+00 7.671480e-04 5.465125e-04 1.030467e-05 2.383157e-05 3.100454e-03 279.04 -2.00 20.00 -2.00 322.50 0.00e+00 -1.894010e-04 1.031173e-03 1.069257e-04 1.616998e-05 3.145996e-03 279.04 -2.00 20.00 -2.00 322.77 0.00e+00 3.351294e-01 5.167334e-03 4.024340e-04 2.329202e-03 1.793202e-02 226.29 3.56 0.00 1.73 31.00 320.22 0.00e+00 9.502138e-05 4.188415e-04 2.787540e-05 2.372117e-05 4.500504e-04 279.04 -2.00 20.00 -2.00 319.14 0.00e+00 2.702 0.000 303.00 329.40 4 4.0366e+00 1.1011e-02 2.6245e-02 2.0366e-03 5.5931e-02 2.2852e-02 1.9494e-02 3.2289e-03 6.9752e-04 5.9994e-02 -1.1678e-02 1.0226e-02 7.3797e-04 2.9911e-04 3.2442e-02 2.2108e-03 6.0315e-03 3.4010e-04 1.1691e-04 1.3073e-02 3.5484e-03 3.4893e-03 1.2535e-04 8.1680e-05 9.8807e-03 9.8614e-04 -1.0398e-04 2.1327e-03 9.5259e-05 2.9786e-05 1.7761e-03 2.1563e-04 8.9913e-05 3.0613e-06 7.5247e-07 4.1901e-04 5.0307e-03 6.6757e-05 3.2445e-01 2.1854e-01 3.2859e-03 3.1617e-04 9.1600e-01 12 8 8 10 0 0 99.89 21.66 0.13 0.00503 0.00668 79 14 1 5 0 645.731 27.26 19.99 21.66 15.35 13.8 975.02 3455 2415 -6580 -3044 -3220 -10083 -671 -2419 1989 4322 821 -1159 1509 4992 -741 168 -910 -1668 795 2220 164 25 -342 -1262 259 1638 11 -293 675 2032 -172 -930 -804 -24 -926 429 -626 950 586 189 -170 -863 -704 -406 -435 -450 337 247 1509 -312 674 -302 -37 -38 690 -109 -91 -178 109 -345 366 452 227 146 -209 168 220 -297 -190 -49 -548 228 349 64 -405 -305 -525 -16 -386 -61 -163 235 -443 664 -6 -37 277 222 -239 0 301 172 74 -208 -355 494 126 -249 156 -49 42 76 29 -57 -99 -33 197 46 317 -175 139 -180 -22 15 -37 -67 141 -29 25 168 -206 10 327 -368 -282 100 -89 -77 -22 201 11 53 -78 96 -27 70 -150 -32 -119 81 -118 118 285 -31 -184 114 89 -279 -125 -142 -552 -39 -166 144 323 67 -101 133 436 -68 16 -94 -186 90 246 18 3 -36 -147 33 226 2 -40 92 306 -31 -205 -204 -6 -264 124 -183 275 173 55 -49 -252 -211 -131 -151 -166 130 98 608 -131 275 -122 -15 -16 317 -55 -49 -94 53 -163 174 239 136 93 -137 108 134 -167 -96 -23 -262 120 210 43 -299 -237 -427 -14 -355 -58 -158 222 -401 551 -5 -27 207 182 -219 0 331 195 80 -211 -334 453 125 -266 172 -57 51 98 40 -81 -141 -45 248 55 367 -210 175 -242 -31 21 -49 -87 175 -35 28 187 -245 13 447 -524 -410 149 -139 -128 -38 347 19 92 -130 155 -43 111 -254 -59 -233 169 -261 271 669 -73 -431