File name: Pandora180s1_BronxNY_20210603_L2Fit_fsus1c2d20210302p1-8.txt File generation date: 20260323T065939.4Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Luke Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 180 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora180_OF_v1d20201002.txt Instrument calibration file used: Pandora180s1_CF_v2d20210302.txt Level 1 file used: Pandora180s1_BronxNY_20210603_L1_smca1c2d20210302p1-8.txt Full location name: New York Botanical Garden NYSDEC (USEPA AQS ID 36-005-0133) Short location name: BronxNY Country of location: USA Location latitude [deg]: 40.8679 Location longitude [deg]: -73.8781 Location altitude [m]: 31 Local noon date: 20210603 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 229 374 Nominal wavelengths inside fitting window [nm]: 306.0637 306.2046 306.3455 306.4864 306.6273 306.7681 306.9090 307.0498 307.1906 307.3315 307.4723 307.6131 307.7539 307.8946 308.0354 308.1762 308.3169 308.4577 308.5984 308.7391 308.8798 309.0205 309.1612 309.3019 309.4425 309.5832 309.7238 309.8644 310.0051 310.1457 310.2863 310.4269 310.5674 310.7080 310.8486 310.9891 311.1297 311.2702 311.4107 311.5512 311.6917 311.8322 311.9726 312.1131 312.2536 312.3940 312.5344 312.6749 312.8153 312.9557 313.0961 313.2364 313.3768 313.5172 313.6575 313.7978 313.9382 314.0785 314.2188 314.3591 314.4994 314.6396 314.7799 314.9201 315.0604 315.2006 315.3408 315.4810 315.6212 315.7614 315.9016 316.0418 316.1819 316.3221 316.4622 316.6023 316.7424 316.8825 317.0226 317.1627 317.3028 317.4428 317.5829 317.7229 317.8629 318.0029 318.1430 318.2829 318.4229 318.5629 318.7029 318.8428 318.9828 319.1227 319.2626 319.4025 319.5424 319.6823 319.8222 319.9620 320.1019 320.2417 320.3816 320.5214 320.6612 320.8010 320.9408 321.0806 321.2203 321.3601 321.4998 321.6396 321.7793 321.9190 322.0587 322.1984 322.3381 322.4778 322.6174 322.7571 322.8967 323.0363 323.1760 323.3156 323.4552 323.5947 323.7343 323.8739 324.0134 324.1530 324.2925 324.4320 324.5715 324.7110 324.8505 324.9900 325.1295 325.2689 325.4084 325.5478 325.6872 325.8266 325.9660 326.1054 326.2448 326.3841 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210603T152439.3Z 7824.642122 344 1 29.48 2 26.33 127.79 64.88 236.43 0.00 1 0.00 1 0 49 1.570e-02 8.386e-03 1.260e-02 6.360e-03 -3.198966e-06 2.467111e-06 1.098750e-07 3.793663e-07 7.506647e-06 232.22 -2.00 3.51 -2.00 321.52 0.00e+00 3.171888e-03 8.650062e-04 4.951745e-05 3.945874e-05 1.974842e-03 285.43 -2.00 20.00 -2.00 321.41 0.00e+00 -2.485897e-04 1.188448e-03 3.826017e-05 2.492711e-05 3.328497e-03 285.43 -2.00 20.00 -2.00 321.47 0.00e+00 2.001789e-03 1.717788e-03 1.644348e-04 1.359551e-05 3.521476e-03 285.43 -2.00 20.00 -2.00 321.43 0.00e+00 1.733260e-01 8.590903e-03 4.724415e-04 1.753760e-03 1.946827e-02 211.77 11.70 0.00 1.58 34.23 317.38 0.00e+00 2.064482e-04 4.617895e-04 1.546543e-04 6.321490e-05 5.108798e-04 285.43 -2.00 20.00 -2.00 316.27 0.00e+00 1.115 0.000 303.00 329.40 4 7.1067e+00 2.1169e-02 1.0990e-02 1.9437e-03 6.2430e-02 8.9142e-03 2.9212e-02 3.7593e-03 3.7076e-04 6.6236e-02 3.5066e-02 1.6533e-02 1.2172e-03 1.4072e-04 3.7260e-02 -1.2674e-02 6.5342e-03 2.2477e-04 3.6676e-05 1.3681e-02 -3.1690e-03 4.6724e-03 1.8745e-04 4.4016e-05 8.8747e-03 1.0820e-04 -1.0952e-02 5.9965e-03 3.7044e-04 2.8238e-05 8.0878e-03 5.6107e-04 2.0549e-04 7.3660e-06 9.6570e-07 5.0635e-04 1.3406e-04 6.6907e-05 3.2359e+00 7.3890e-01 9.9299e-03 5.7409e-04 1.5016e+00 12 8 8 10 0 0 99.90 24.01 1.42 0.00013 0.00442 9 9 1 5 0 3274.480 27.88 20.00 24.01 25.93 15.1 1074.93 -510 -1129 2206 -4382 3171 -595 -270 1075 -8360 5482 -4118 41 -680 747 2992 926 -319 167 2030 -1227 2291 1996 -429 5113 -1498 84 -2300 3082 -3075 1288 3049 1625 -573 -658 1380 -511 -151 -1623 1187 -784 2042 1277 -410 -509 -688 131 -1481 1762 -1079 -209 409 303 -436 -976 1086 -108 -1016 -1354 1397 -382 975 -416 -996 131 -374 29 -818 42 -152 -1129 -1156 -1430 1007 -1791 1582 -561 737 549 512 608 -690 1653 -219 242 -1935 25 348 -618 -773 1190 1649 -1105 1058 601 1004 497 -787 459 -946 615 217 463 -969 916 155 532 -577 170 -562 -1145 11 -1134 73 103 296 -28 -885 381 -506 -333 -924 406 144 -221 978 -443 -367 1 423 -663 356 -335 183 752 163 716 -558 -622 72 908 39 424 152 -618 -148 -125 -85 -207 412 -869 594 -125 -62 271 -2481 1462 -1229 12 -205 225 878 281 -102 55 674 -417 709 636 -136 1583 -517 30 -869 1060 -1119 489 1295 742 -306 -379 806 -311 -92 -992 700 -459 1124 689 -245 -287 -409 80 -964 1137 -724 -140 272 199 -289 -671 776 -83 -818 -1072 1093 -284 696 -317 -847 108 -321 25 -676 36 -116 -797 -782 -1012 770 -1560 1451 -555 683 543 537 664 -780 1813 -233 261 -1949 22 307 -579 -791 1309 1785 -1273 1278 687 1070 515 -860 533 -1173 784 263 580 -1287 1231 208 676 -756 204 -643 -1323 14 -1462 98 141 402 -38 -1119 451 -577 -365 -1029 471 176 -282 1257 -587 -504 2 634 -1027 558 -527 280 1112 237 1026 -834 -990 111 1481 67 768 281 -1156 -270 -227 SS 20210603T191908.6Z 7824.804960 478 1 3.12 2 35.65 250.04 105.58 277.16 0.00 1 0.00 1 0 49 7.779e-03 5.477e-03 7.292e-03 5.106e-03 -2.403768e-06 2.029883e-06 5.011923e-08 3.792546e-07 3.697108e-06 232.23 -2.00 3.51 -2.00 320.59 0.00e+00 1.104272e-03 6.599198e-04 2.700208e-05 3.942159e-05 9.692227e-04 285.45 -2.00 20.00 -2.00 320.28 0.00e+00 -5.405369e-04 9.493115e-04 2.465519e-05 2.498666e-05 1.648809e-03 285.45 -2.00 20.00 -2.00 320.80 0.00e+00 1.682885e-03 1.211027e-03 1.110560e-04 1.352372e-05 1.745555e-03 285.45 -2.00 20.00 -2.00 320.54 0.00e+00 1.737730e-01 6.400662e-03 1.848379e-04 1.752837e-03 9.674499e-03 219.00 8.95 0.00 1.54 16.95 315.89 0.00e+00 -3.296875e-04 2.739821e-04 3.029099e-05 6.322694e-05 2.533072e-04 285.45 -2.00 20.00 -2.00 314.87 0.00e+00 1.230 0.000 303.00 329.40 4 4.6255e+00 1.7743e-02 1.1998e-02 1.9393e-03 3.0902e-02 5.8244e-03 2.2088e-02 1.6694e-03 3.5268e-04 3.2884e-02 1.1495e-02 1.2555e-02 5.2342e-04 1.1547e-04 1.8414e-02 -4.8034e-03 4.7173e-03 3.0913e-04 2.5116e-05 6.7997e-03 -1.4751e-03 3.4200e-03 5.1120e-05 3.7281e-05 4.3952e-03 1.1678e-03 7.8315e-04 3.9895e-03 1.0973e-04 2.0488e-05 3.9122e-03 -4.0384e-04 1.5439e-04 2.4088e-06 8.9794e-07 2.4747e-04 2.1592e-03 -6.2688e-05 2.1358e-01 5.5203e-01 3.8163e-03 7.9489e-04 7.3875e-01 12 9 9 12 1 1 999.00 24.06 0.28 0.00216 -0.00092 1 20 1 5 0 1471.720 27.99 20.00 24.06 32.59 15.2 1100.00 -2036 1048 1994 -1479 2344 -747 -1520 -307 -629 1393 -1390 1714 -1223 1031 -782 486 -295 -352 -1425 -446 817 1716 -62 284 -1015 -1033 1087 -391 -1434 219 821 2439 29 39 -198 382 411 366 -914 -1394 422 397 549 217 1055 246 -109 -9 -158 -1016 -58 -59 21 5 -42 310 360 -710 -910 652 799 -103 -181 -682 -707 -714 457 -558 -622 1329 -1880 -393 -801 -78 -258 389 830 196 606 -171 143 492 281 -572 83 572 -41 659 107 533 425 217 261 483 -226 484 49 -706 -175 -239 105 67 -563 275 137 -474 -133 525 -517 -1055 -361 11 -591 -382 463 333 -135 1098 355 -841 -150 500 -219 -101 -546 -634 275 552 660 81 -275 -13 -58 289 446 -425 153 67 83 -455 -110 417 -211 27 458 -492 -585 320 634 -481 741 -243 -552 -122 -269 599 -626 766 -531 481 -368 229 -135 -169 -710 -218 399 768 -27 129 -490 -490 517 -194 -711 107 461 1473 21 28 -147 288 310 273 -684 -1020 292 286 391 150 765 188 -87 -7 -131 -807 -48 -49 17 4 -35 278 337 -659 -777 543 645 -89 -163 -631 -678 -680 440 -505 -542 1034 -1442 -311 -707 -71 -243 385 854 204 670 -199 160 578 315 -631 83 554 -39 653 110 597 491 262 305 530 -246 505 53 -799 -208 -281 128 85 -714 357 177 -616 -159 605 -603 -1174 -419 14 -741 -487 577 404 -165 1257 413 -947 -169 597 -262 -126 -695 -779 348 736 872 110 -384 -18 -78 400 600 -572 211 94 120 -704 -172 679 -337 42 751 -805 SS 20210603T200511.5Z 7824.836938 503 1 29.55 2 44.06 260.26 113.72 285.18 0.00 1 0.00 1 0 49 3.366e-02 1.215e-02 2.166e-02 9.214e-03 2.566988e-06 3.511363e-06 1.860089e-07 3.794796e-07 1.577054e-05 232.23 -2.00 3.51 -2.00 321.96 0.00e+00 2.073938e-03 1.294411e-03 1.379561e-04 3.952580e-05 4.243400e-03 285.45 -2.00 20.00 -2.00 321.97 0.00e+00 -3.243839e-04 1.743060e-03 6.587417e-05 2.494041e-05 7.162464e-03 285.45 -2.00 20.00 -2.00 321.79 0.00e+00 3.723366e-03 2.701408e-03 3.367738e-04 1.360844e-05 7.543305e-03 285.45 -2.00 20.00 -2.00 321.84 0.00e+00 1.987110e-01 1.318878e-02 7.817200e-04 1.753976e-03 4.179573e-02 211.30 15.54 0.00 1.43 72.54 318.03 0.00e+00 7.065455e-04 7.632263e-04 2.222048e-05 6.321766e-05 1.094908e-03 285.45 -2.00 20.00 -2.00 316.88 0.00e+00 1.390 0.000 303.00 329.40 4 6.9468e+00 3.0867e-02 1.3817e-02 1.9453e-03 1.3299e-01 4.1308e-03 4.5152e-02 4.3333e-03 3.8192e-04 1.4136e-01 2.9188e-02 2.5419e-02 1.8167e-03 1.5384e-04 8.0044e-02 -2.5101e-03 1.0553e-02 8.3713e-04 4.6599e-05 2.9449e-02 -7.3968e-03 7.1726e-03 4.1979e-04 4.9384e-05 1.9070e-02 9.1612e-05 -1.2225e-02 9.3043e-03 5.3066e-04 3.2810e-05 1.6670e-02 1.2151e-03 3.1001e-04 8.0335e-06 1.0764e-06 1.0999e-03 -5.7479e-04 3.2301e-04 3.6378e+00 1.0206e+00 2.4885e-02 7.0551e-04 2.9166e+00 12 8 8 10 0 0 99.97 24.08 0.56 -0.00057 0.00870 28 28 1 5 0 1055.040 27.99 20.00 24.08 33.34 15.2 1100.00 -11751 1673 -12285 -16349 -12123 -4122 10808 688 3982 895 2260 1912 197 7112 -4603 9134 154 12275 -2209 -19 701 3597 -1478 -2646 3378 -2299 3890 -1729 -1196 -3791 69 -1040 -2412 4614 1312 4782 -1080 2861 704 639 -2782 -4836 1512 -2738 535 -1569 901 -1269 -2018 -1761 422 232 -1408 4734 -1183 1547 -2345 2068 1867 -2040 -758 -1306 74 -1581 606 64 -139 284 -528 851 -1813 -352 816 2977 -499 463 -855 -176 185 -910 529 328 -136 -134 1801 53 -338 -1448 -312 1374 653 1414 226 -910 -799 -558 122 -2925 1905 749 1365 -807 -249 210 -1094 706 -152 603 -35 -939 748 533 -1353 942 398 -869 1793 -96 -415 96 1218 186 -350 -994 -232 709 -1230 1114 -97 789 692 -697 -694 -1010 505 -705 -57 -572 220 564 260 -239 -830 171 -107 926 -1649 225 -1984 -2747 -1993 -684 1886 134 888 212 541 472 51 1732 -1249 2203 42 3087 -655 -5 191 893 -378 -705 893 -682 1120 -506 -346 -1221 24 -431 -1161 2244 684 2466 -594 1505 377 335 -1461 -2533 740 -1451 289 -906 530 -782 -1268 -1116 260 142 -874 2858 -804 1093 -1797 1498 1259 -1340 -479 -873 54 -1272 494 53 -109 208 -354 516 -1085 -217 552 2192 -415 404 -789 -172 191 -985 576 356 -142 -129 1562 47 -297 -1356 -288 1368 714 1594 251 -964 -871 -585 132 -3503 2289 866 1635 -1027 -330 287 -1507 910 -201 733 -40 -1104 903 688 -1882 1306 548 -1177 2246 -116 -482 107 1358 222 -443 -1319 -313 964 -1769 1651 -152 1253 1121 -1142 -1107 -1570 754 -1056 -87 -938 386 1053 472 -456 -1624 332 -206 1752 SS 20210603T200953.5Z 7824.840203 506 1 29.46 2 44.93 261.18 114.54 286.04 0.00 1 0.00 1 0 33 1.168e-02 5.431e-03 1.084e-02 4.860e-03 -1.879466e-08 1.888142e-06 1.611716e-07 3.793965e-07 5.524516e-06 232.23 -2.00 3.51 -2.00 321.69 0.00e+00 3.230446e-03 6.745597e-04 9.995671e-05 3.947671e-05 1.445088e-03 285.45 -2.00 20.00 -2.00 321.76 0.00e+00 5.767248e-04 9.075325e-04 4.641173e-05 2.490727e-05 2.467747e-03 285.45 -2.00 20.00 -2.00 321.57 0.00e+00 2.816470e-03 1.350020e-03 2.537324e-04 1.352861e-05 2.619663e-03 285.45 -2.00 20.00 -2.00 321.60 0.00e+00 1.955634e-01 6.660408e-03 6.717689e-04 1.753710e-03 1.461063e-02 209.44 7.98 0.00 1.37 25.52 317.68 0.00e+00 -6.376266e-04 3.802783e-04 1.773825e-04 6.322261e-05 3.808189e-04 285.45 -2.00 20.00 -2.00 316.55 0.00e+00 1.411 0.000 303.00 329.40 4 6.4350e+00 1.6054e-02 1.3902e-02 1.9437e-03 4.6373e-02 -1.8822e-02 2.2454e-02 5.0876e-03 3.8033e-04 4.9543e-02 4.7090e-02 1.2932e-02 1.4869e-03 1.4532e-04 2.7580e-02 -1.3555e-02 5.4312e-03 4.3083e-04 3.9616e-05 1.0405e-02 -7.0206e-03 3.7067e-03 3.0196e-04 4.7330e-05 6.6543e-03 1.5257e-04 -3.8214e-03 4.3574e-03 4.0927e-04 2.3955e-05 4.6535e-03 -1.4871e-04 1.5644e-04 7.7612e-06 9.6950e-07 3.7378e-04 1.3507e-03 -1.4540e-06 1.5906e+00 5.2847e-01 1.3935e-02 5.1109e-04 1.0225e+00 12 8 8 10 0 0 99.98 24.08 0.74 0.00135 0.00022 11 11 1 5 0 2677.350 27.99 20.00 24.08 33.61 15.2 1100.00 915 -327 2671 5642 -1617 -1832 -3863 -846 3094 -3508 2228 199 -1610 -820 -2861 1539 61 -1054 1524 -1344 919 881 -1145 -117 1972 1851 1178 1220 2826 491 -1526 -181 961 -1673 -360 -1356 1479 2464 -440 41 -975 365 -455 -1765 -1374 577 -212 -3 1599 -441 7 -505 238 1139 390 720 -228 -18 463 -605 306 -782 -1329 113 552 733 -1061 373 1172 -321 -306 -2175 674 151 262 291 263 -885 41 -642 60 -450 309 -51 -395 35 50 -246 -673 240 347 278 567 -49 133 405 116 -1012 -180 40 526 -19 638 832 -329 -124 188 -546 126 65 291 413 4 94 152 80 -500 -594 -193 391 -111 382 -730 -144 -153 -217 -236 -192 505 441 -206 -314 -91 194 -259 -94 -124 48 180 369 -492 566 32 174 -234 -140 126 -50 421 862 -270 -335 -802 -189 721 -899 553 52 -437 -224 -794 417 18 -322 468 -422 265 237 -306 -32 558 561 370 367 831 161 -587 -81 489 -860 -190 -738 863 1413 -258 23 -543 196 -245 -1004 -823 356 -138 -2 1064 -304 5 -341 159 778 285 561 -170 -14 345 -425 208 -568 -1084 99 451 655 -929 300 847 -216 -197 -1498 503 126 239 280 241 -871 43 -698 66 -495 323 -54 -386 32 44 -229 -689 267 384 320 634 -57 144 421 127 -1202 -203 47 640 -24 847 1143 -455 -163 228 -677 147 76 356 541 5 121 192 108 -649 -731 -226 438 -126 460 -940 -192 -208 -301 -310 -265 725 648 -311 -473 -134 276 -360 -129 -176 72 293 640 -918 1091 64 346 -461 -273 SS 20210603T205258.7Z 7824.870123 530 1 29.34 2 53.04 268.86 121.80 294.45 0.00 1 0.00 1 0 49 1.020e-03 6.165e-04 1.134e-03 5.238e-04 2.923126e-07 2.021233e-07 1.840205e-08 3.793686e-07 4.834949e-07 232.23 -2.00 3.51 -2.00 321.49 0.00e+00 4.308563e-04 7.022975e-05 9.989769e-06 3.947592e-05 1.250342e-04 285.46 -2.00 20.00 -2.00 321.32 0.00e+00 -1.950209e-05 9.601716e-05 5.825822e-06 2.498855e-05 2.156756e-04 285.46 -2.00 20.00 -2.00 321.44 0.00e+00 3.943619e-04 1.362947e-04 3.560761e-05 1.350941e-05 2.286731e-04 285.46 -2.00 20.00 -2.00 321.39 0.00e+00 2.345801e-01 7.491782e-04 7.765375e-05 1.753844e-03 1.283099e-03 233.90 0.79 0.00 1.16 2.23 317.56 0.00e+00 6.427429e-05 3.998279e-05 1.005972e-05 6.322525e-05 3.342612e-05 285.46 -2.00 20.00 -2.00 316.40 0.00e+00 1.659 0.000 303.00 329.40 4 2.4241e+00 2.1277e-03 1.6092e-02 1.9420e-03 4.0483e-03 -9.2796e-03 2.8410e-03 1.7253e-03 3.7926e-04 4.3359e-03 4.4886e-03 1.5137e-03 1.7743e-04 1.4098e-04 2.3961e-03 -1.9680e-03 6.3605e-04 7.5968e-05 3.8583e-05 9.3983e-04 -2.3834e-04 4.1003e-04 2.7869e-05 4.9020e-05 6.0099e-04 6.4348e-03 -1.5912e-03 3.7626e-04 4.2488e-05 1.7199e-05 3.2488e-04 2.2222e-04 1.6181e-05 1.7178e-06 9.7017e-07 3.2735e-05 1.2650e-03 2.5745e-05 -1.4412e-01 5.1661e-02 6.9240e-04 6.5545e-04 8.4980e-02 10 0 0 10 0 0 99.18 24.08 0.26 0.00127 0.00296 209 209 1 5 0 140.350 27.99 20.00 24.08 32.26 15.3 1100.00 24 233 158 12 159 -222 -228 215 -7 -95 -213 43 56 -71 77 -147 33 69 17 -260 -161 165 122 373 161 87 -159 -202 -219 -1 -276 121 41 -121 186 -138 97 -71 -14 132 32 -131 7 92 -46 11 -29 109 121 29 29 -84 115 -82 36 -89 37 -13 43 60 -92 165 -107 18 -162 67 -147 -70 72 -49 73 -42 65 -108 186 -58 -13 -12 -60 -32 -33 53 28 62 -33 36 29 -30 -35 -87 56 3 17 59 -19 -31 23 42 -5 38 -21 49 -17 66 -65 -52 5 17 65 -3 -3 35 -48 -2 -34 58 23 -51 13 -16 -76 36 -57 -39 40 -29 -25 48 10 53 13 -73 9 -21 -26 77 -74 27 -43 38 -6 78 -42 42 2 -54 3 36 26 2 27 -41 -48 51 -2 -23 -53 11 15 -19 21 -41 9 21 5 -82 -48 50 36 117 49 29 -54 -66 -71 0 -112 58 21 -67 106 -81 57 -42 -8 75 18 -72 4 53 -28 7 -20 75 85 21 20 -59 80 -60 26 -69 30 -10 32 46 -68 120 -88 16 -139 61 -130 -57 53 -36 51 -32 50 -94 176 -55 -12 -12 -63 -34 -37 59 29 64 -32 34 27 -30 -35 -98 64 4 20 64 -21 -33 25 47 -6 47 -27 61 -22 90 -89 -68 7 20 73 -3 -3 45 -61 -2 -47 77 29 -61 16 -19 -91 43 -73 -51 54 -41 -34 69 15 82 19 -108 13 -31 -38 110 -110 41 -70 62 -10 143 -75 75 4 -95 SS 20210603T210619.8Z 7824.879395 540 1 29.90 2 55.57 271.04 123.95 297.28 0.00 1 0.00 1 0 49 3.216e-03 1.292e-03 3.346e-03 1.348e-03 9.611668e-07 5.119544e-07 2.540904e-08 3.794414e-07 1.521123e-06 232.23 -2.00 3.51 -2.00 321.70 0.00e+00 6.457843e-04 1.840019e-04 2.045559e-05 3.951426e-05 3.925923e-04 285.46 -2.00 20.00 -2.00 321.59 0.00e+00 2.323302e-04 2.464915e-04 6.371009e-06 2.496410e-05 6.808483e-04 285.46 -2.00 20.00 -2.00 321.58 0.00e+00 4.855826e-04 3.657660e-04 5.074468e-05 1.346266e-05 7.208167e-04 285.46 -2.00 20.00 -2.00 321.59 0.00e+00 2.505339e-01 1.983288e-03 1.310205e-04 1.753830e-03 4.055646e-03 232.94 1.94 0.00 1.09 7.02 317.95 0.00e+00 -1.657271e-04 1.116541e-04 2.029733e-05 6.322110e-05 1.057658e-04 285.46 -2.00 20.00 -2.00 316.80 0.00e+00 1.763 0.000 303.00 329.40 4 4.1052e+00 5.4450e-03 1.7104e-02 1.9427e-03 1.2768e-02 3.2773e-03 7.5163e-03 1.8789e-03 3.8187e-04 1.3673e-02 7.8439e-03 4.0024e-03 3.9850e-04 1.4773e-04 7.5408e-03 -4.8916e-03 1.7525e-03 2.0300e-04 4.3563e-05 2.9959e-03 6.3782e-04 1.1033e-03 3.5840e-05 5.1600e-05 1.9267e-03 1.0518e-03 -3.3169e-03 9.6700e-04 7.4007e-05 1.8195e-05 9.4182e-04 3.8886e-04 4.2088e-05 2.2517e-06 9.8271e-07 1.0376e-04 7.6164e-04 8.0005e-05 4.4700e-02 1.3079e-01 2.3157e-03 5.9320e-04 2.6132e-01 11 8 0 10 0 0 99.96 24.08 0.28 0.00076 0.00373 36 36 1 5 0 830.490 27.99 20.00 24.08 33.24 15.2 1100.00 -1434 -344 46 1379 367 387 -762 -485 1095 -554 -481 -498 -529 -685 557 411 -112 597 36 271 -301 -561 40 145 1156 125 79 -311 387 337 -524 253 207 -462 271 313 116 126 -297 -227 -19 102 227 -363 279 -20 164 113 37 -134 -230 27 -293 -134 -62 251 -150 109 -177 -9 -31 -111 -156 -166 202 -125 -98 -289 32 -25 -83 242 -14 222 25 201 -162 43 -128 -56 122 33 126 226 169 -173 -125 53 26 -7 51 103 36 81 -16 -18 -107 -30 -45 -136 84 -76 123 -19 -21 9 -27 -155 121 107 -156 -54 -29 42 -5 -71 -24 -6 56 199 26 44 -186 -101 -162 -25 82 14 24 140 85 -129 56 -3 -25 29 29 -147 33 153 -132 47 68 66 -97 -36 -165 -43 6 180 50 58 -131 -94 228 -122 -110 -118 -129 -170 136 103 -30 166 10 78 -82 -144 10 38 325 38 25 -95 116 111 -183 104 98 -239 146 172 64 69 -164 -123 -10 53 118 -199 162 -13 106 68 23 -85 -145 17 -181 -85 -42 184 -116 84 -127 -6 -20 -78 -123 -143 179 -110 -83 -228 23 -18 -57 175 -10 186 23 182 -153 43 -138 -63 140 38 138 226 169 -160 -114 51 25 -8 61 119 44 92 -17 -18 -114 -34 -55 -161 104 -98 168 -26 -30 12 -34 -195 144 129 -197 -68 -39 56 -6 -91 -30 -8 66 227 31 55 -230 -131 -216 -34 117 21 35 209 129 -197 84 -4 -38 43 45 -226 55 256 -236 89 123 121 -176 -68