File name: Pandora180s1_BronxNY_20210703_L2Fit_fsus1c2d20210302p1-8.txt File generation date: 20260323T070752.0Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Luke Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 180 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora180_OF_v1d20201002.txt Instrument calibration file used: Pandora180s1_CF_v2d20210302.txt Level 1 file used: Pandora180s1_BronxNY_20210703_L1_smca1c2d20210302p1-8.txt Full location name: New York Botanical Garden NYSDEC (USEPA AQS ID 36-005-0133) Short location name: BronxNY Country of location: USA Location latitude [deg]: 40.8679 Location longitude [deg]: -73.8781 Location altitude [m]: 31 Local noon date: 20210703 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 229 374 Nominal wavelengths inside fitting window [nm]: 306.0637 306.2046 306.3455 306.4864 306.6273 306.7681 306.9090 307.0498 307.1906 307.3315 307.4723 307.6131 307.7539 307.8946 308.0354 308.1762 308.3169 308.4577 308.5984 308.7391 308.8798 309.0205 309.1612 309.3019 309.4425 309.5832 309.7238 309.8644 310.0051 310.1457 310.2863 310.4269 310.5674 310.7080 310.8486 310.9891 311.1297 311.2702 311.4107 311.5512 311.6917 311.8322 311.9726 312.1131 312.2536 312.3940 312.5344 312.6749 312.8153 312.9557 313.0961 313.2364 313.3768 313.5172 313.6575 313.7978 313.9382 314.0785 314.2188 314.3591 314.4994 314.6396 314.7799 314.9201 315.0604 315.2006 315.3408 315.4810 315.6212 315.7614 315.9016 316.0418 316.1819 316.3221 316.4622 316.6023 316.7424 316.8825 317.0226 317.1627 317.3028 317.4428 317.5829 317.7229 317.8629 318.0029 318.1430 318.2829 318.4229 318.5629 318.7029 318.8428 318.9828 319.1227 319.2626 319.4025 319.5424 319.6823 319.8222 319.9620 320.1019 320.2417 320.3816 320.5214 320.6612 320.8010 320.9408 321.0806 321.2203 321.3601 321.4998 321.6396 321.7793 321.9190 322.0587 322.1984 322.3381 322.4778 322.6174 322.7571 322.8967 323.0363 323.1760 323.3156 323.4552 323.5947 323.7343 323.8739 324.0134 324.1530 324.2925 324.4320 324.5715 324.7110 324.8505 324.9900 325.1295 325.2689 325.4084 325.5478 325.6872 325.8266 325.9660 326.1054 326.2448 326.3841 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210703T154436.1Z 7854.655974 424 1 30.27 2 23.94 132.91 57.66 251.48 0.00 1 0.00 1 0 49 4.430e-03 2.699e-03 4.205e-03 2.340e-03 -2.107356e-06 9.173381e-07 3.921789e-08 3.801756e-07 2.119299e-06 232.90 -2.00 3.51 -2.00 321.28 0.00e+00 1.082309e-03 3.109071e-04 1.545299e-05 3.961794e-05 5.533475e-04 288.32 -2.00 20.00 -2.00 321.16 0.00e+00 7.325272e-06 4.342242e-04 6.923137e-06 2.490917e-05 9.387663e-04 288.32 -2.00 20.00 -2.00 321.29 0.00e+00 3.495125e-04 5.947343e-04 3.290467e-05 1.379174e-05 1.000620e-03 288.32 -2.00 20.00 -2.00 321.22 0.00e+00 1.789258e-01 3.230391e-03 9.141779e-05 1.753254e-03 5.485627e-03 233.39 4.51 0.00 1.53 9.65 317.04 0.00e+00 -1.595232e-04 1.567084e-04 2.540906e-05 6.395214e-05 1.459735e-04 288.32 -2.00 20.00 -2.00 315.85 0.00e+00 1.094 0.000 303.00 329.40 4 5.5983e+00 9.4293e-03 1.0617e-02 1.9412e-03 1.7614e-02 2.4807e-02 1.2216e-02 1.3189e-03 3.6654e-04 1.8689e-02 1.1789e-02 6.5221e-03 1.9307e-04 1.3341e-04 1.0462e-02 -4.9041e-03 2.3948e-03 1.0177e-04 3.1957e-05 3.8641e-03 -6.6482e-04 1.6847e-03 5.0524e-05 4.2287e-05 2.5055e-03 5.0026e-04 -7.4113e-03 2.1011e-03 1.2162e-04 2.4920e-05 2.2901e-03 5.7264e-04 7.2905e-05 2.7421e-06 9.5063e-07 1.4172e-04 4.3171e-03 6.9240e-05 4.5751e-01 2.7285e-01 2.5694e-03 6.6093e-04 4.3124e-01 12 9 8 11 8 0 99.99 24.07 0.48 0.00432 0.00869 36 36 1 5 0 840.720 27.99 20.00 24.07 25.72 16.5 1032.05 523 233 566 863 1190 -665 1148 162 222 -572 -825 -1267 -380 216 -521 916 -832 1076 -1465 72 -1211 628 1400 -217 -228 -704 550 300 402 106 -92 361 -176 -384 669 57 -179 263 -476 -74 614 104 411 -41 450 -295 -123 128 217 -527 -150 514 -178 198 -232 40 -60 -389 -138 -119 486 -229 -212 -72 186 -283 45 448 -11 396 -421 566 -49 131 -348 -82 -296 23 425 69 84 -1 84 -104 -415 -551 -464 59 -347 496 -101 344 -238 244 108 -227 2 -384 107 -282 419 -311 324 286 -99 331 -239 191 0 -46 -154 -61 -260 188 248 92 213 -367 108 -446 36 230 -80 136 -306 262 4 -24 -318 -2 183 -70 -123 -1 251 -140 97 -19 -124 -143 66 168 -20 140 -229 83 101 49 125 187 261 -161 302 48 70 -185 -273 -432 -132 75 -181 319 -309 408 -584 28 -446 211 454 -74 -81 -269 212 110 146 42 -42 193 -99 -232 413 36 -114 165 -298 -45 393 65 254 -27 304 -191 -83 87 151 -374 -105 352 -123 141 -176 32 -50 -321 -104 -92 364 -183 -172 -63 168 -255 39 358 -9 287 -295 410 -40 107 -311 -78 -292 24 473 80 100 -1 94 -108 -394 -529 -433 58 -339 527 -118 413 -279 267 111 -226 2 -434 126 -350 535 -415 451 410 -141 446 -299 219 1 -50 -177 -75 -342 251 325 118 257 -423 118 -516 42 258 -95 167 -384 333 6 -33 -465 -2 278 -106 -183 -1 351 -196 140 -29 -189 -232 114 302 -36 256 -415 148 SS 20210703T190118.7Z 7854.792578 551 1 29.87 2 31.17 244.10 93.02 284.69 0.00 1 0.00 1 0 49 5.732e-03 3.307e-03 4.509e-03 2.513e-03 -1.495215e-06 9.831377e-07 4.343969e-08 3.801502e-07 2.738863e-06 232.90 -2.00 3.51 -2.00 321.16 0.00e+00 7.770480e-04 3.345873e-04 2.048763e-05 3.961236e-05 7.150828e-04 288.33 -2.00 20.00 -2.00 320.94 0.00e+00 6.906004e-04 4.644169e-04 7.686492e-06 2.494668e-05 1.212881e-03 288.33 -2.00 20.00 -2.00 321.20 0.00e+00 2.895954e-04 6.361446e-04 6.103915e-05 1.377116e-05 1.294713e-03 288.33 -2.00 20.00 -2.00 321.09 0.00e+00 1.871929e-01 3.336266e-03 1.812327e-04 1.753541e-03 7.118378e-03 222.99 4.35 0.00 1.46 12.50 316.91 0.00e+00 2.948017e-05 1.667523e-04 2.756574e-05 6.395040e-05 1.891994e-04 288.33 -2.00 20.00 -2.00 315.77 0.00e+00 1.168 0.000 303.00 329.40 4 5.8662e+00 9.1336e-03 1.1341e-02 1.9415e-03 2.2788e-02 1.9624e-03 1.1951e-02 1.5050e-03 3.6891e-04 2.4237e-02 1.9007e-02 6.6184e-03 3.8781e-04 1.3335e-04 1.3560e-02 -7.0531e-03 2.5673e-03 7.1436e-05 3.2816e-05 5.0691e-03 1.6801e-03 1.8105e-03 1.0192e-04 4.3241e-05 3.2464e-03 3.5552e-04 -8.8313e-03 2.1160e-03 6.8823e-05 2.3106e-05 2.7475e-03 4.9459e-04 7.7328e-05 2.0977e-06 9.4209e-07 1.8332e-04 4.3199e-03 6.6707e-05 5.3797e-01 2.8196e-01 3.9817e-03 6.5527e-04 5.4797e-01 12 8 8 10 0 0 99.94 24.16 0.43 0.00432 0.00809 9 9 1 5 0 3318.450 28.10 20.00 24.16 27.79 16.7 1046.41 -252 -1553 -49 1098 3411 -1918 351 -1410 -264 563 -635 -767 -200 762 516 -962 -464 320 -395 115 -79 99 1906 446 70 941 67 -96 -227 77 1310 122 -257 9 -156 -655 538 -39 116 -345 -81 443 222 -208 -591 859 116 351 91 398 -239 85 -187 -388 -335 872 -557 -265 96 -643 180 61 -845 -110 -905 147 320 39 262 138 -526 379 149 -44 218 114 161 -337 633 -75 -330 824 2 -88 -548 -448 -249 -244 -101 69 -180 212 26 257 142 -338 128 133 -80 238 533 -67 12 352 -135 58 72 428 -168 -156 -4 -174 -45 -127 82 -123 -254 -287 -38 188 -473 134 -33 -109 -57 9 -18 -155 531 29 -163 -241 98 -421 497 105 -22 47 -368 128 -174 422 167 144 -214 -170 -48 -324 -11 232 717 -462 92 -416 -83 180 -210 -261 -69 265 178 -343 -172 123 -157 45 -29 34 626 154 25 363 27 -36 -86 32 610 61 -148 6 -101 -433 352 -25 75 -218 -50 262 131 -128 -386 578 82 253 67 295 -177 62 -136 -292 -269 738 -499 -233 77 -486 132 48 -740 -103 -813 142 296 33 204 98 -360 271 119 -39 211 107 157 -353 698 -87 -391 958 3 -91 -565 -424 -229 -238 -108 74 -211 257 31 284 146 -369 134 149 -95 294 682 -89 16 471 -179 79 91 495 -186 -174 -4 -218 -59 -171 108 -158 -312 -334 -46 217 -559 154 -39 -137 -73 11 -25 -222 787 41 -234 -346 136 -621 706 149 -33 68 -577 213 -288 722 293 252 -371 -291 SS 20210703T190718.7Z 7854.796745 555 1 29.86 2 32.20 245.86 94.07 285.67 0.00 1 0.00 1 0 49 1.025e-03 6.070e-04 8.610e-04 5.415e-04 4.071548e-07 2.125437e-07 1.640172e-08 3.800985e-07 4.894256e-07 232.90 -2.00 3.51 -2.00 320.91 0.00e+00 2.502812e-04 7.069892e-05 5.425792e-06 3.959225e-05 1.277555e-04 288.33 -2.00 20.00 -2.00 320.68 0.00e+00 -1.025499e-04 1.002443e-04 4.794501e-06 2.496346e-05 2.167471e-04 288.33 -2.00 20.00 -2.00 321.03 0.00e+00 3.049911e-04 1.295007e-04 2.144682e-05 1.373265e-05 2.314045e-04 288.33 -2.00 20.00 -2.00 320.85 0.00e+00 1.877168e-01 7.193566e-04 5.000041e-05 1.753156e-03 1.272523e-03 237.27 0.98 0.00 1.46 2.23 316.47 0.00e+00 5.501329e-05 3.249391e-05 1.581520e-05 6.397994e-05 3.377909e-05 288.33 -2.00 20.00 -2.00 315.32 0.00e+00 1.181 0.000 303.00 329.40 4 3.0558e+00 2.2553e-03 1.1461e-02 1.9399e-03 4.0717e-03 1.9938e-02 2.7594e-03 1.2536e-03 3.6041e-04 4.3321e-03 1.7387e-03 1.4688e-03 1.2484e-04 1.2208e-04 2.4208e-03 -3.7371e-04 5.3905e-04 3.0018e-05 2.8870e-05 9.0366e-04 -4.2449e-04 3.7784e-04 2.6102e-05 4.0615e-05 5.8033e-04 5.7247e-03 1.5397e-03 4.3647e-04 2.5194e-05 2.0292e-05 4.8448e-04 4.9109e-04 1.6380e-05 1.1851e-06 9.2456e-07 3.2776e-05 4.2749e-03 6.9959e-05 -7.2608e-02 5.9839e-02 2.3084e-04 6.9427e-04 9.7307e-02 10 0 0 10 0 0 99.86 24.16 0.27 0.00427 0.00802 147 147 1 5 0 203.060 28.10 19.99 24.16 28.44 16.8 1051.23 384 -324 -158 -301 210 90 -179 202 -73 145 -223 2 -273 239 79 219 49 -138 99 -133 93 -55 10 -5 192 110 -61 95 -221 129 -134 128 -97 -28 106 -123 64 -48 -2 7 2 -120 60 21 -57 22 -113 125 -89 128 -17 173 153 -58 -30 -21 79 -1 60 -146 -100 74 -103 -21 -86 -21 -61 3 -70 -87 7 6 66 -4 1 -88 114 -1 -36 59 7 80 -52 117 -51 48 -18 -4 -9 18 -34 13 41 7 53 -10 -36 43 -63 9 -48 31 -24 60 -67 6 -35 -3 -7 22 22 -51 -38 -17 18 21 3 -18 -4 90 -20 66 -44 1 -9 37 14 12 7 -36 47 -29 34 -80 -8 7 -5 0 -72 52 -61 46 57 12 -51 8 89 -83 -43 -80 56 26 -53 67 -26 53 -83 1 -107 95 31 88 20 -60 44 -59 39 -21 4 -2 79 48 -27 40 -94 59 -72 73 -64 -19 72 -85 44 -33 -1 5 2 -81 41 15 -39 16 -84 95 -68 100 -13 132 117 -46 -25 -18 69 -1 51 -115 -77 60 -87 -19 -81 -20 -56 3 -57 -65 5 5 55 -4 1 -87 119 -1 -40 68 9 93 -58 129 -51 44 -18 -4 -9 19 -39 16 48 8 58 -10 -40 48 -75 11 -62 39 -31 82 -90 8 -44 -3 -8 26 25 -63 -47 -21 23 27 3 -21 -5 102 -23 75 -53 1 -11 47 19 16 9 -51 69 -42 48 -110 -11 10 -7 -1 -108 82 -98 76 98 20 -85 14 SS 20210703T193709.4Z 7854.817470 576 1 28.70 2 37.49 253.55 99.20 290.67 0.00 1 0.00 1 0 49 1.574e-02 7.307e-03 1.218e-02 5.497e-03 -2.692407e-06 2.136026e-06 6.593015e-08 3.802239e-07 7.454538e-06 232.90 -2.00 3.51 -2.00 321.65 0.00e+00 1.666361e-03 7.553800e-04 1.844340e-05 3.964578e-05 1.943255e-03 288.34 -2.00 20.00 -2.00 321.67 0.00e+00 4.477993e-04 1.023775e-03 1.875813e-05 2.491508e-05 3.323908e-03 288.34 -2.00 20.00 -2.00 321.54 0.00e+00 1.407781e-03 1.474093e-03 1.270873e-04 1.371655e-05 3.554764e-03 288.34 -2.00 20.00 -2.00 321.57 0.00e+00 2.188680e-01 7.863110e-03 3.485792e-04 1.753847e-03 1.953856e-02 230.29 8.91 0.00 1.24 34.34 317.68 0.00e+00 -1.342940e-04 4.313864e-04 7.449851e-05 6.393909e-05 5.185043e-04 288.34 -2.00 20.00 -2.00 316.45 0.00e+00 1.259 0.000 303.00 329.40 4 6.7244e+00 2.1656e-02 1.2282e-02 1.9441e-03 6.2168e-02 4.2771e-02 2.9583e-02 2.3873e-03 3.8140e-04 6.6443e-02 1.3878e-02 1.5899e-02 8.7721e-04 1.4522e-04 3.6828e-02 -6.9300e-03 6.3191e-03 2.9531e-04 4.2346e-05 1.3817e-02 -1.5808e-03 4.2053e-03 5.5600e-05 4.7740e-05 8.9835e-03 1.2683e-04 -1.4320e-02 4.7314e-03 2.0446e-04 2.5860e-05 6.2868e-03 4.1526e-04 1.7820e-04 4.1517e-06 9.8491e-07 5.0414e-04 4.7192e-03 9.3311e-05 3.4584e+00 6.0751e-01 3.3647e-03 5.3598e-04 1.3898e+00 12 8 8 10 0 0 99.43 24.17 -0.22 0.00472 0.00789 8 8 1 5 0 3587.370 28.10 20.00 24.17 30.15 16.6 1061.44 4952 6875 -4952 1207 -4351 782 -2012 118 4328 4227 -408 -2883 -1972 -3806 -659 -346 -782 -1483 477 -1702 -183 1821 2137 4015 -644 -1921 3390 -34 3498 643 -908 -931 896 1456 3263 -2175 -339 -518 908 -737 -1104 325 -2112 1028 -1755 254 1566 979 -1403 715 -206 111 1085 -1477 -816 918 228 -613 539 -1304 -82 121 -1364 134 -601 -709 459 -432 879 -546 -896 876 451 117 948 438 254 -116 547 -777 377 1603 862 515 -913 -652 -2959 -869 666 58 735 -139 823 475 563 -362 -827 -706 -712 44 424 1142 838 246 -508 -386 10 -182 16 -170 -477 -442 -30 -98 -418 438 -664 441 -632 605 177 -301 -604 -360 -86 437 673 -147 88 75 528 -544 -469 -105 881 400 414 -237 -497 -450 428 270 438 -163 -240 -298 670 995 -841 194 -754 141 -413 26 998 1008 -104 -776 -539 -1076 -181 -96 -228 -453 147 -532 -53 488 562 1075 -190 -610 1050 -11 1043 215 -352 -422 457 797 1818 -1187 -201 -305 524 -422 -616 175 -1163 573 -1061 158 1003 647 -962 486 -141 74 722 -1041 -607 715 187 -498 401 -929 -57 88 -1121 117 -498 -643 396 -350 636 -368 -584 589 339 98 858 422 257 -114 565 -846 414 1727 893 543 -894 -589 -2680 -815 674 65 808 -159 911 547 606 -380 -908 -832 -881 52 515 1430 1104 337 -698 -504 12 -224 18 -201 -589 -582 -38 -125 -529 586 -853 530 -735 671 200 -362 -768 -477 -117 599 957 -203 126 109 782 -813 -681 -148 1316 597 578 -356 -806 -779 782 516 852 -319 -466 -575 SS 20210703T194706.5Z 7854.824381 579 1 14.86 2 39.30 255.81 100.87 292.38 0.00 1 0.00 1 0 49 4.847e-03 2.760e-03 4.942e-03 2.791e-03 -6.433343e-07 1.087844e-06 2.906916e-08 3.801228e-07 2.316579e-06 232.90 -2.00 3.51 -2.00 321.10 0.00e+00 8.436209e-04 3.696984e-04 2.112494e-05 3.960319e-05 6.023893e-04 288.34 -2.00 20.00 -2.00 320.87 0.00e+00 2.102895e-04 5.138635e-04 3.552193e-06 2.495881e-05 1.023724e-03 288.34 -2.00 20.00 -2.00 321.16 0.00e+00 4.883248e-05 6.968894e-04 1.361841e-05 1.375475e-05 1.094400e-03 288.34 -2.00 20.00 -2.00 321.03 0.00e+00 2.027988e-01 3.766572e-03 5.844069e-05 1.753622e-03 6.042243e-03 230.07 4.61 0.00 1.35 10.60 316.87 0.00e+00 1.120924e-04 1.849658e-04 1.571140e-05 6.396434e-05 1.601218e-04 288.34 -2.00 20.00 -2.00 315.71 0.00e+00 1.291 0.000 303.00 329.40 4 5.2593e+00 1.0807e-02 1.2527e-02 1.9412e-03 1.9286e-02 2.8437e-02 1.3975e-02 1.3669e-03 3.7056e-04 2.0543e-02 8.1011e-03 7.5648e-03 2.3115e-04 1.3143e-04 1.1439e-02 -2.9585e-03 2.9196e-03 1.0855e-04 3.3191e-05 4.3248e-03 1.5437e-04 2.0040e-03 5.4467e-05 4.3212e-05 2.7627e-03 5.5687e-04 -1.3608e-03 2.2267e-03 8.1476e-05 2.0127e-05 2.0701e-03 5.0806e-04 8.4943e-05 2.1855e-06 9.3387e-07 1.5498e-04 4.0150e-03 5.6388e-05 1.5153e-02 3.0147e-01 3.3753e-03 6.3176e-04 4.4581e-01 12 9 9 12 1 1 99.87 24.17 0.48 0.00401 0.00789 6 14 1 5 0 2098.990 28.10 20.00 24.17 30.56 16.5 1062.92 1060 669 -602 246 764 2249 -1788 -766 488 -2107 144 -488 596 -70 56 397 -94 -172 347 -89 -1064 441 612 1126 -179 -591 301 38 -20 363 -36 -355 625 -475 26 147 590 -122 156 76 -488 667 295 -975 -456 9 124 496 347 233 -282 -233 -31 -1013 225 684 -577 -219 171 324 -41 264 -378 -139 185 -364 -133 216 -97 -316 -30 -66 426 -411 711 -202 158 -53 128 -143 262 134 183 -42 101 -622 -40 -333 -260 -279 159 58 -17 536 283 39 -302 -229 310 -217 11 248 -103 229 -16 217 -217 -85 -139 -18 114 -220 -166 66 219 294 -320 -26 -536 -206 101 373 -181 211 -112 13 -77 -52 141 85 -42 -203 -12 -8 79 101 149 38 130 -117 -143 257 -10 -62 -203 83 203 141 -135 54 170 543 -502 -237 147 -669 46 -161 199 -24 19 136 -34 -65 134 -34 -387 162 219 417 -65 -230 119 14 -8 148 -17 -197 362 -300 17 98 391 -81 103 49 -305 402 178 -621 -306 6 90 368 262 179 -216 -175 -23 -791 185 553 -495 -184 142 251 -31 214 -317 -126 173 -339 -119 193 -78 -234 -21 -49 354 -353 662 -201 164 -54 140 -163 304 154 201 -46 100 -573 -39 -317 -271 -297 184 70 -20 586 310 41 -338 -257 364 -267 14 329 -135 309 -22 276 -275 -99 -165 -21 133 -276 -220 89 290 376 -392 -30 -639 -234 117 458 -220 265 -144 17 -105 -70 197 122 -61 -297 -17 -12 113 144 205 57 207 -187 -243 427 -18 -106 -342 147 SS 20210703T202357.2Z 7854.849968 604 1 29.59 2 46.15 263.21 106.86 299.01 0.00 1 0.00 1 0 49 1.047e-02 3.660e-03 9.130e-03 3.654e-03 -1.161771e-06 1.403876e-06 8.331352e-08 3.802906e-07 4.996169e-06 232.90 -2.00 3.51 -2.00 321.85 0.00e+00 1.593370e-03 5.103841e-04 5.025861e-05 3.966410e-05 1.297194e-03 288.34 -2.00 20.00 -2.00 321.93 0.00e+00 9.508249e-05 6.761422e-04 1.272185e-05 2.491562e-05 2.211350e-03 288.34 -2.00 20.00 -2.00 321.69 0.00e+00 -1.450896e-04 1.021286e-03 3.841816e-05 1.375894e-05 2.363171e-03 288.34 -2.00 20.00 -2.00 321.76 0.00e+00 2.294557e-01 5.371119e-03 7.807742e-05 1.753840e-03 1.311858e-02 229.08 5.73 0.00 1.18 23.01 318.04 0.00e+00 -5.615815e-04 3.131719e-04 3.467811e-05 6.391788e-05 3.454241e-04 288.34 -2.00 20.00 -2.00 316.79 0.00e+00 1.441 0.000 303.00 329.40 4 5.8090e+00 1.4216e-02 1.3985e-02 1.9445e-03 4.1811e-02 2.0301e-02 2.0177e-02 1.8492e-03 3.8907e-04 4.4567e-02 2.3215e-02 1.0864e-02 3.2284e-04 1.5116e-04 2.4753e-02 -1.0656e-02 4.5408e-03 5.3628e-04 4.7409e-05 9.5429e-03 -1.1227e-03 2.9097e-03 9.9615e-05 5.0186e-05 6.0522e-03 2.6988e-04 -1.0946e-02 3.0612e-03 2.4209e-04 2.4925e-05 3.7771e-03 3.4849e-04 1.1603e-04 5.4220e-06 1.0007e-06 3.3447e-04 4.6895e-03 6.1032e-05 7.5362e-01 3.9009e-01 5.5115e-03 5.1231e-04 9.0675e-01 12 8 8 10 0 0 99.98 24.16 0.08 0.00469 0.00735 30 30 1 5 0 985.980 28.10 20.00 24.16 30.52 16.6 1063.19 6347 -3891 963 1614 -1290 -2699 -3204 331 -1905 502 -1301 1730 -1722 -695 697 4155 -804 -728 2451 216 826 369 753 -915 -834 1030 863 1937 177 -55 -1293 563 -830 522 74 -810 46 -557 900 -565 46 370 137 -309 -299 1152 -102 -30 -679 1009 -685 -112 367 53 181 -182 910 -1063 -303 -834 -326 228 61 601 228 -29 -765 542 -538 -854 681 -90 -405 49 765 -259 406 -118 1 282 91 151 -445 128 -436 119 -525 -146 101 195 434 -140 -64 157 -64 -40 60 -51 -71 279 -475 3 25 333 -79 566 -260 250 253 -246 -312 -567 -62 -72 556 259 -123 -171 17 58 -240 252 -64 81 -386 -25 -226 144 84 -196 276 -395 -141 144 527 291 -179 -124 -302 241 -75 54 -14 132 40 -123 712 -525 131 218 -184 -428 -570 63 -403 107 -292 389 -411 -167 164 971 -208 -197 663 59 212 89 178 -230 -223 290 250 532 49 -17 -460 232 -398 267 39 -446 25 -305 483 -301 24 186 69 -164 -168 671 -63 -19 -441 654 -450 -72 234 35 127 -137 712 -836 -219 -569 -217 161 48 512 183 -23 -651 423 -384 -560 425 -59 -301 41 686 -249 368 -115 1 302 100 164 -464 122 -423 106 -462 -136 103 200 483 -163 -73 166 -69 -42 66 -60 -80 328 -587 4 34 465 -111 750 -322 313 301 -297 -394 -698 -80 -94 713 323 -161 -213 20 66 -279 312 -84 111 -493 -32 -306 205 126 -299 427 -614 -213 210 744 409 -262 -194 -511 433 -144 109 -27 250 81 -249