File name: Pandora206s1_BuffaloNY_20230325_L2Fit_fsus1c4d20220512p1-8.txt File generation date: 20241121T054635.3Z Data description: Level 2 spectral fitting results file Data file version: fsus1c4p1-8 Local principal investigator: ---- Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 206 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora206_OF_v2d20211008.txt Instrument calibration file used: Pandora206s1_CF_v4d20220512.txt Level 1 file used: Pandora206s1_BuffaloNY_20230325_L1_smca1c4d20220512p1-8.txt Full location name: University at Buffalo Short location name: BuffaloNY Country of location: Canada Location latitude [deg]: 43.0015 Location longitude [deg]: -78.7869 Location altitude [m]: 190 Local noon date: 20230325 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 230 375 Nominal wavelengths inside fitting window [nm]: 306.0611 306.2020 306.3428 306.4837 306.6246 306.7654 306.9063 307.0471 307.1879 307.3287 307.4695 307.6103 307.7511 307.8918 308.0326 308.1733 308.3140 308.4548 308.5955 308.7362 308.8768 309.0175 309.1582 309.2988 309.4394 309.5801 309.7207 309.8613 310.0019 310.1424 310.2830 310.4236 310.5641 310.7046 310.8451 310.9857 311.1261 311.2666 311.4071 311.5476 311.6880 311.8285 311.9689 312.1093 312.2497 312.3901 312.5305 312.6708 312.8112 312.9515 313.0919 313.2322 313.3725 313.5128 313.6531 313.7934 313.9336 314.0739 314.2141 314.3543 314.4946 314.6348 314.7750 314.9151 315.0553 315.1955 315.3356 315.4758 315.6159 315.7560 315.8961 316.0362 316.1763 316.3163 316.4564 316.5964 316.7364 316.8765 317.0165 317.1565 317.2964 317.4364 317.5764 317.7163 317.8563 317.9962 318.1361 318.2760 318.4159 318.5558 318.6956 318.8355 318.9753 319.1152 319.2550 319.3948 319.5346 319.6744 319.8141 319.9539 320.0937 320.2334 320.3731 320.5128 320.6525 320.7922 320.9319 321.0716 321.2112 321.3509 321.4905 321.6301 321.7697 321.9093 322.0489 322.1885 322.3280 322.4676 322.6071 322.7467 322.8862 323.0257 323.1652 323.3046 323.4441 323.5836 323.7230 323.8624 324.0018 324.1413 324.2806 324.4200 324.5594 324.6988 324.8381 324.9774 325.1168 325.2561 325.3954 325.5347 325.6739 325.8132 325.9525 326.0917 326.2309 326.3702 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Spectrometer control temperature [°C], 999=no temperature signal Column 155: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 156: Temperature in head sensor [°C], 999=no temperature signal Column 157: Temperature at electronics board 1 [°C], 999=no temperature signal Column 158: Temperature at electronics board 2 [°C], 999=no temperature signal Column 159: Humidity in head sensor [%], -9=no humidity signal Column 160: Pressure in head sensor [hPa], -9=no pressure signal Columns 161-306: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 307-452: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20230325T164419.3Z 8484.697446 148 1 28.00 2 41.92 166.15 53.19 95.59 0.00 1 0.00 1 0 49 5.170e-02 2.621e-02 4.395e-02 1.811e-02 -5.714040e-06 6.697929e-06 6.014873e-07 3.619107e-07 2.244410e-05 226.62 -2.00 3.55 -2.00 321.74 0.00e+00 1.044793e-02 2.431101e-03 3.879341e-04 2.203474e-05 6.044442e-03 275.56 -2.00 20.00 -2.00 321.75 0.00e+00 -2.357007e-03 3.404230e-03 1.779567e-04 2.414213e-05 1.080796e-02 275.56 -2.00 20.00 -2.00 321.58 0.00e+00 9.625118e-03 4.980415e-03 7.052597e-04 9.558341e-06 1.112693e-02 275.56 -2.00 20.00 -2.00 321.62 0.00e+00 1.571550e-01 2.144180e-02 1.669004e-03 1.016305e-03 6.223830e-02 169.60 30.37 0.00 0.57 108.25 317.60 0.00e+00 4.143210e-03 1.362947e-03 3.803211e-04 4.435177e-05 1.564670e-03 275.56 -2.00 20.00 -2.00 316.91 0.00e+00 1.342 0.000 303.00 329.40 4 8.6645e+00 5.5592e-02 1.4489e-02 1.8395e-03 1.9609e-01 -2.2822e-02 6.0214e-02 1.3870e-02 2.4320e-04 2.0993e-01 9.7826e-02 3.9342e-02 2.6779e-03 8.5560e-05 1.1582e-01 1.7628e-02 1.7219e-02 3.1285e-03 3.7582e-05 4.2667e-02 -5.6458e-02 1.3925e-02 1.2153e-03 4.6479e-05 2.9492e-02 1.9059e-05 1.0228e-01 2.2078e-02 1.6006e-03 1.8303e-05 1.6042e-02 1.4278e-03 5.7158e-04 2.9799e-05 7.7581e-07 1.4975e-03 -1.4166e-02 -3.5879e-05 7.0503e+00 1.8877e+00 4.2022e-02 4.7170e-04 4.4360e+00 12 8 8 10 0 0 -480.28 17.47 2.91 -0.01417 -0.00327 7 7 2 8 0 4000.000 15.00 17.47 14.23 21.06 20.87 15.3 1019.21 -1996 -19569 -7015 -10298 3625 2740 7881 7266 848 19826 3845 8462 -4479 16994 2152 12845 132 -5629 -5841 -1848 -1400 -9859 1781 -11939 -6322 -12927 2427 -12065 -2762 -3516 7090 862 1616 11490 -2482 10168 -2784 6663 -2221 -849 -9821 8834 -53 3344 -2672 1419 1556 648 -1694 -1519 1136 -2707 3433 -1454 10457 -936 4545 -4039 401 -3430 -25 -2851 -4654 1167 -1878 3628 -874 560 2428 3426 -1555 -1951 -4759 367 354 -2174 1546 2592 569 781 256 -2099 4223 -2308 -53 -4984 -2994 -1116 -530 24 2918 977 265 2065 -1586 1841 -6586 1254 -1658 1986 3083 2242 -674 1439 -190 -1745 1318 -621 2523 -3247 1346 -4307 1146 65 3762 -889 -944 -1360 -1209 -2006 718 2853 -4634 3102 4871 2957 -2587 821 -3134 568 154 1238 -1172 928 -946 -1756 1677 -955 -269 -1233 846 -36 1628 -374 334 -524 -230 -3335 -1044 -1550 460 408 1304 1431 205 3806 943 2004 -1281 3658 553 2864 36 -1638 -1739 -522 -371 -2655 407 -3440 -1782 -4301 691 -3822 -771 -1124 2290 362 771 5479 -1394 5273 -1644 3630 -1301 -493 -6059 4232 -28 1751 -1586 841 967 417 -1115 -1007 724 -1775 2126 -998 6762 -740 3544 -3367 287 -2367 -16 -1963 -3723 959 -1657 2997 -731 428 1682 2112 -961 -1277 -3662 300 307 -2049 1445 2572 619 881 298 -2519 4504 -2398 -50 -4557 -2580 -1001 -523 25 3335 1188 312 2310 -1724 1829 -7440 1420 -1965 2379 3842 2922 -950 2062 -275 -2436 1692 -739 2718 -3733 1536 -5619 1508 89 4893 -1182 -1178 -1589 -1349 -2235 783 3225 -5777 3733 5915 3710 -3550 1157 -4833 864 242 1923 -1803 1361 -1386 -2542 2384 -1487 -450 -2156 1545 -70 3146 -744 652 -1024 SS 20230325T182511.6Z 8484.767495 175 1 28.00 2 43.49 203.62 35.73 117.30 0.00 1 0.00 1 0 33 3.995e-02 1.933e-02 2.951e-02 1.261e-02 -1.550878e-05 4.668050e-06 4.649334e-07 3.619184e-07 1.765739e-05 226.62 -2.00 3.55 -2.00 321.63 0.00e+00 7.088934e-03 1.675895e-03 2.430273e-04 2.204661e-05 4.676704e-03 275.57 -2.00 20.00 -2.00 321.62 0.00e+00 6.594938e-04 2.316799e-03 1.433497e-04 2.414722e-05 8.350859e-03 275.57 -2.00 20.00 -2.00 321.52 0.00e+00 1.033109e-02 3.376616e-03 6.961198e-04 9.578427e-06 8.598633e-03 275.57 -2.00 20.00 -2.00 321.54 0.00e+00 1.993294e-01 1.568279e-02 1.373552e-03 1.016307e-03 4.813033e-02 188.77 17.70 0.00 0.18 84.42 317.64 0.00e+00 2.682301e-03 9.204240e-04 8.105384e-05 4.436833e-05 1.203510e-03 275.57 -2.00 20.00 -2.00 316.77 0.00e+00 1.377 0.000 303.00 329.40 4 8.2252e+00 3.6051e-02 1.4752e-02 1.8403e-03 1.5206e-01 1.5624e-02 4.7654e-02 8.9024e-03 2.4384e-04 1.6277e-01 6.3822e-02 2.8985e-02 2.8653e-03 8.4639e-05 8.9255e-02 -1.6229e-02 1.2921e-02 2.3270e-03 3.5982e-05 3.2665e-02 -2.0856e-02 9.7934e-03 7.2599e-04 4.7185e-05 2.3023e-02 2.8942e-05 1.0163e-03 1.0906e-02 1.0746e-03 1.7677e-05 1.1533e-02 -6.1225e-04 3.9146e-04 1.9839e-05 7.8656e-07 1.1584e-03 -1.0504e-02 1.0076e-04 6.0340e+00 1.2343e+00 1.8053e-02 3.8715e-04 3.1490e+00 12 8 8 10 0 0 5.10 17.47 5.18 -0.01050 -0.01518 7 7 2 8 0 4000.000 15.00 17.47 12.85 21.06 20.87 15.2 1008.47 19333 -13694 9724 -7290 6657 -8915 1239 7299 -36 5656 1986 4672 -8795 10770 -2378 5912 -7143 -1132 -3996 1309 -3531 -4386 1267 -1792 -4894 -5721 2058 -2450 5033 -3101 4005 302 231 3412 355 2603 2225 5186 -1085 -2352 -6876 11162 -7765 -209 -800 -594 2101 5491 -2068 -559 -1040 -2352 2473 166 5024 49 2192 -2893 1166 -2214 747 -3347 -3168 1034 -450 1209 1192 1719 -2111 1843 965 -10397 3918 1089 1103 -46 -418 1949 -325 275 473 -914 2719 -3167 -32 -1418 -1325 -2214 -81 -543 2717 -1281 729 1914 516 -230 -1690 -1368 -2296 1116 880 1226 4184 699 -1540 -1729 239 665 2937 -2511 -20 -1667 266 -350 1840 -364 230 -417 -1748 -1652 1137 47 -781 2196 40 1593 -761 -584 -1766 759 -1237 1801 -266 384 -222 572 -225 -823 -1649 68 1162 903 352 -892 865 -656 2079 -2152 1334 -1174 945 -1657 237 1486 -8 1294 503 1185 -2510 2661 -661 1529 -2175 -330 -1228 385 -1024 -1186 320 -488 -1443 -1827 638 -752 1407 -1036 1407 129 115 1789 198 1465 1272 2860 -639 -1375 -4065 5366 -4449 -115 -469 -363 1312 3406 -1388 -374 -696 -1568 1577 113 3463 38 1760 -2418 858 -1568 495 -2385 -2530 865 -397 1046 997 1337 -1544 1227 615 -7707 2830 869 964 -43 -405 1971 -360 315 553 -1086 2982 -3369 -30 -1293 -1159 -2057 -78 -581 3121 -1611 872 2128 544 -239 -1757 -1539 -2731 1340 1112 1602 5564 968 -2195 -2463 310 789 3328 -2875 -23 -2091 349 -472 2403 -473 281 -500 -2035 -1837 1232 55 -965 2764 53 2109 -1018 -827 -2657 1141 -1945 2760 -403 561 -320 799 -321 -1258 -2746 119 2062 1694 678 -1756 1650 -1255 SS 20230325T184049.7Z 8484.778353 180 1 30.06 2 44.75 208.93 33.26 121.85 0.00 1 0.00 1 0 49 4.892e-03 2.484e-03 5.800e-03 2.719e-03 -1.455442e-06 1.008766e-06 4.301968e-08 3.619087e-07 2.207533e-06 226.62 -2.00 3.55 -2.00 321.63 0.00e+00 1.312972e-03 3.557283e-04 3.630501e-05 2.201007e-05 5.843796e-04 275.57 -2.00 20.00 -2.00 321.63 0.00e+00 -4.999809e-04 5.005102e-04 6.341332e-06 2.415427e-05 1.022464e-03 275.57 -2.00 20.00 -2.00 321.53 0.00e+00 4.602686e-04 7.001993e-04 8.255233e-05 9.609914e-06 1.052902e-03 275.57 -2.00 20.00 -2.00 321.53 0.00e+00 1.939300e-01 3.717421e-03 2.422763e-04 1.016377e-03 5.894795e-03 223.75 4.63 0.00 0.14 10.25 317.59 0.00e+00 1.683366e-04 1.911370e-04 1.501822e-05 4.441709e-05 1.475419e-04 275.57 -2.00 20.00 -2.00 316.60 0.00e+00 1.406 0.000 303.00 329.40 4 5.7492e+00 9.5711e-03 1.3362e-02 1.8396e-03 1.8665e-02 7.8717e-03 1.3301e-02 1.7905e-03 2.4576e-04 1.9924e-02 1.3940e-02 7.2772e-03 5.2898e-04 8.3947e-05 1.1080e-02 -9.5984e-03 2.8670e-03 1.8946e-04 3.3761e-05 4.1434e-03 7.3962e-04 2.0693e-03 9.6092e-05 4.5069e-05 2.7754e-03 4.0129e-04 -8.3173e-03 2.2170e-03 1.4773e-04 1.5341e-05 2.0006e-03 1.9617e-04 7.9475e-05 3.0378e-06 7.8031e-07 1.4173e-04 -1.1291e-02 1.1167e-04 1.1432e+00 2.6978e-01 5.7352e-03 4.4080e-04 4.1388e-01 12 8 8 10 0 0 99.99 17.47 0.47 -0.01129 -0.00979 68 68 4 8 0 441.460 15.00 17.47 12.78 21.06 20.87 15.1 1008.36 223 303 -1032 638 2265 109 954 733 460 -757 -263 -787 577 -167 -2035 381 251 -608 -385 -307 759 -311 -1370 -67 -79 1078 88 382 1429 979 -195 -331 -224 203 109 -221 311 -16 117 -551 -1119 1362 169 -536 -166 -98 -61 -119 -259 213 210 -3 118 783 275 244 73 -211 -22 210 55 -201 354 -94 29 -116 -69 -444 103 210 769 -221 -243 -480 -90 -321 -320 114 107 -122 -69 -35 238 148 -151 -696 -7 -6 -214 -44 56 353 528 107 167 66 -355 -174 121 -27 171 -142 280 92 179 -274 -186 206 89 -118 -128 -126 -160 -93 93 353 -9 -508 -61 -6 270 100 -165 61 82 -237 -125 -227 11 168 270 115 40 -40 -269 -218 -19 5 -45 129 167 162 -61 -83 6 -77 33 50 -182 109 380 21 199 171 118 -200 -71 -219 163 -48 -591 110 76 -194 -126 -101 231 -88 -379 -19 -24 342 29 119 427 323 -74 -150 -118 109 60 -126 178 -9 71 -327 -642 741 92 -305 -100 -62 -41 -81 -177 148 145 -2 80 540 204 182 58 -167 -17 148 37 -143 286 -78 25 -100 -57 -369 76 140 482 -145 -180 -397 -82 -292 -301 115 115 -138 -80 -41 265 150 -140 -631 -6 -6 -214 -45 64 424 615 117 170 68 -358 -193 141 -33 216 -187 388 126 244 -380 -238 240 97 -129 -147 -155 -211 -126 124 459 -11 -595 -72 -7 303 120 -197 76 105 -308 -167 -324 16 257 423 182 61 -59 -390 -309 -27 7 -71 219 301 310 -119 -165 12 -147 SS 20230325T191116.6Z 8484.799498 194 1 2.00 2 47.84 218.56 28.84 132.25 0.00 1 0.00 1 0 33 3.500e-03 2.189e-03 3.656e-03 2.030e-03 -9.965864e-07 7.567808e-07 3.366083e-08 3.618681e-07 1.583774e-06 226.62 -2.00 3.55 -2.00 321.12 0.00e+00 4.275790e-04 2.580809e-04 1.808416e-05 2.196085e-05 4.178807e-04 275.57 -2.00 20.00 -2.00 320.89 0.00e+00 -1.542872e-04 3.683212e-04 9.824702e-06 2.415993e-05 7.308406e-04 275.57 -2.00 20.00 -2.00 321.16 0.00e+00 5.275144e-04 4.804282e-04 1.298899e-05 9.539138e-06 7.531829e-04 275.57 -2.00 20.00 -2.00 321.03 0.00e+00 2.124032e-01 2.646548e-03 6.740010e-05 1.016475e-03 4.223221e-03 229.61 3.09 0.00 0.13 7.34 316.90 0.00e+00 1.911993e-04 1.231056e-04 1.222639e-05 4.444638e-05 1.057050e-04 275.57 -2.00 20.00 -2.00 315.95 0.00e+00 1.487 0.000 303.00 329.40 4 2.7772e+00 7.4867e-03 1.4124e-02 1.8408e-03 1.3338e-02 8.5356e-03 9.6838e-03 1.5274e-03 2.4719e-04 1.4267e-02 2.3764e-03 5.2390e-03 1.5621e-04 7.9283e-05 7.9192e-03 8.6291e-04 2.0484e-03 1.5336e-04 2.8939e-05 2.9954e-03 -2.1521e-03 1.4845e-03 5.4930e-05 4.2333e-05 1.9993e-03 6.9875e-03 -2.9583e-03 1.4016e-03 4.7225e-05 9.3329e-06 1.2980e-03 -5.5533e-05 5.6692e-05 1.5942e-06 7.3267e-07 1.0142e-04 -1.0890e-02 7.2072e-05 -1.9047e-02 1.9021e-01 1.1296e-03 4.5422e-04 2.8985e-01 12 9 9 12 1 1 99.74 17.47 0.28 -0.01089 -0.01131 13 116 1 8 0 122.000 15.00 17.47 14.48 21.06 20.87 15.5 1022.16 -24 229 -518 503 -600 509 -833 678 -137 664 217 1010 -384 -304 -551 -170 154 -130 412 -911 483 -103 554 -5 185 -162 506 -1936 442 -615 -170 259 -256 169 -55 67 -361 382 -250 624 547 488 -167 -96 -282 -23 -129 -496 405 -19 -97 75 459 -507 -64 -178 99 79 -27 -252 12 301 34 -48 60 324 24 -63 -127 659 64 50 -139 -95 -83 -233 228 -174 -40 -124 191 -2 13 -309 177 -145 157 -286 -11 -36 195 -39 -178 -109 78 199 17 268 -308 30 -88 -114 -37 -15 502 -435 61 182 -161 -51 301 -78 138 34 191 -174 -237 0 100 -33 35 30 -17 141 -145 60 -276 129 141 118 -115 -32 -243 -23 363 -171 -71 142 96 -173 -114 50 119 -110 148 -67 -4 46 -112 105 -127 118 -221 189 -42 208 70 334 -132 -107 -191 -59 57 -50 163 -368 179 -35 182 -2 68 -64 209 -760 164 -254 -77 133 -148 106 -36 45 -243 253 -167 402 340 296 -105 -60 -190 -16 -91 -363 297 -14 -72 55 332 -380 -51 -148 84 70 -22 -194 9 235 29 -44 56 304 21 -55 -104 501 46 38 -114 -84 -77 -224 226 -180 -44 -139 220 -2 15 -335 180 -135 145 -271 -11 -38 223 -47 -211 -125 85 205 18 308 -361 37 -109 -147 -49 -20 690 -576 77 215 -185 -59 361 -98 180 45 250 -223 -300 0 117 -38 40 36 -20 181 -190 77 -368 177 203 168 -169 -47 -350 -33 502 -241 -99 205 148 -277 -190 86 207 -195 256 -114 SS 20230325T191636.7Z 8484.803202 196 1 3.58 2 48.46 220.15 28.13 134.32 0.00 1 0.00 1 0 33 3.590e-03 2.263e-03 5.969e-03 3.331e-03 1.773509e-06 1.237527e-06 2.420843e-08 3.618765e-07 1.623620e-06 226.62 -2.00 3.55 -2.00 321.11 0.00e+00 4.933167e-04 4.240440e-04 8.767628e-06 2.195613e-05 4.284957e-04 275.57 -2.00 20.00 -2.00 320.87 0.00e+00 -8.968891e-04 6.055631e-04 3.108322e-06 2.416195e-05 7.496928e-04 275.57 -2.00 20.00 -2.00 321.15 0.00e+00 2.978782e-04 7.985499e-04 7.091212e-05 9.535241e-06 7.726355e-04 275.57 -2.00 20.00 -2.00 321.02 0.00e+00 2.086938e-01 4.288954e-03 2.014159e-04 1.016446e-03 4.336690e-03 223.13 5.00 0.00 0.13 7.54 316.86 0.00e+00 9.415777e-05 2.015039e-04 2.955543e-06 4.444481e-05 1.084334e-04 275.57 -2.00 20.00 -2.00 315.94 0.00e+00 1.505 0.000 303.00 329.40 4 4.3383e+00 1.1493e-02 1.4297e-02 1.8408e-03 1.3702e-02 -3.5778e-03 1.5154e-02 1.7152e-03 2.4778e-04 1.4650e-02 1.6629e-02 8.3710e-03 3.7052e-04 7.8854e-05 8.1322e-03 -8.3933e-03 3.3658e-03 1.2706e-04 2.9029e-05 3.0945e-03 -5.7163e-04 2.4385e-03 3.7562e-05 4.2148e-05 2.0563e-03 1.4684e-03 -4.2720e-03 2.2599e-03 5.4475e-05 9.1876e-06 1.3159e-03 -1.3451e-05 9.2899e-05 1.5543e-06 7.4797e-07 1.0405e-04 -1.0559e-02 7.6921e-05 -1.5713e-03 3.1011e-01 7.1506e-04 4.1208e-04 2.9559e-01 12 9 9 12 1 1 99.16 17.47 0.22 -0.01056 -0.01066 4 21 1 8 0 683.000 15.00 17.47 15.30 21.06 20.87 15.7 1029.33 -1166 1016 -287 607 -667 -965 1174 401 -205 -63 64 -881 -45 468 25 243 -179 -286 408 -1155 -323 1014 -106 971 525 -327 -256 -334 -131 7 296 398 -18 -310 132 159 291 280 1 -191 -210 -330 745 -462 -123 -302 315 -145 261 -109 437 -57 -292 -305 253 85 -329 -58 116 223 110 78 -102 160 -250 -66 -38 -135 216 61 -167 291 93 332 -94 -236 -326 119 -246 235 14 -149 -512 377 162 202 -477 -347 111 242 -131 178 267 -124 -82 -18 102 -90 -200 151 202 362 -185 -58 82 40 -48 169 270 -193 212 -362 -118 -119 388 -25 -94 98 -27 -212 -2 81 -56 10 -145 -340 -48 -4 300 -117 -48 110 272 -116 -134 -109 -108 -219 140 -29 407 -10 -53 64 -190 49 -217 204 -62 128 -142 -230 300 116 -63 -20 21 -298 -15 164 9 85 -65 -109 159 -461 -122 349 -37 340 195 -129 -106 -131 -50 3 134 210 -11 -195 86 104 191 186 0 -124 -135 -207 456 -300 -83 -209 227 -106 192 -82 325 -42 -218 -228 198 71 -284 -50 94 171 84 61 -87 146 -234 -62 -35 -118 175 46 -121 219 76 290 -89 -230 -329 126 -268 268 16 -172 -579 402 165 190 -443 -334 113 264 -150 213 315 -140 -89 -18 109 -102 -234 183 253 461 -246 -78 110 54 -61 204 309 -223 250 -447 -153 -155 505 -32 -119 117 -31 -240 -3 97 -70 13 -187 -446 -64 -5 429 -169 -69 161 392 -165 -187 -149 -152 -321 215 -45 670 -18 -92 113 -329 84 SS 20230325T195102.4Z 8484.827111 207 1 29.42 2 52.90 229.69 24.24 149.85 0.00 1 0.00 1 0 33 2.476e-02 7.005e-03 1.613e-02 5.875e-03 -7.330351e-06 2.147866e-06 1.272174e-07 3.619604e-07 1.099078e-05 226.63 -2.00 3.55 -2.00 321.82 0.00e+00 2.988168e-03 7.823251e-04 8.978408e-05 2.208032e-05 2.900587e-03 275.57 -2.00 20.00 -2.00 321.82 0.00e+00 -1.330161e-04 1.068126e-03 1.974873e-05 2.417706e-05 5.174734e-03 275.57 -2.00 20.00 -2.00 321.66 0.00e+00 1.474441e-03 1.611354e-03 1.321590e-04 9.596020e-06 5.326193e-03 275.57 -2.00 20.00 -2.00 321.71 0.00e+00 2.403708e-01 8.049318e-03 3.130338e-04 1.016374e-03 3.007215e-02 211.43 7.78 0.00 0.12 52.30 318.13 0.00e+00 -1.925181e-05 4.810360e-04 1.354756e-05 4.440174e-05 7.498834e-04 275.57 -2.00 20.00 -2.00 317.18 0.00e+00 1.654 0.000 303.00 329.40 4 7.0956e+00 1.8530e-02 1.5750e-02 1.8406e-03 9.4605e-02 1.2687e-02 2.7342e-02 2.2472e-03 2.4822e-04 1.0136e-01 4.5741e-02 1.5385e-02 9.8896e-04 8.7420e-05 5.5679e-02 -2.3657e-02 7.1847e-03 3.6835e-04 4.3081e-05 2.1360e-02 -1.2629e-03 4.9143e-03 1.7236e-04 5.1791e-05 1.4638e-02 7.5218e-05 -8.6254e-03 4.2767e-03 2.7372e-04 1.6121e-05 6.3480e-03 -3.0041e-04 1.7148e-04 5.8311e-06 7.8947e-07 7.1760e-04 -1.1340e-02 4.5705e-05 1.2343e+00 5.3470e-01 1.1547e-02 3.6916e-04 1.9218e+00 12 8 8 10 0 0 99.96 17.50 0.82 -0.01134 -0.01363 9 9 1 8 0 3268.270 15.00 17.50 16.75 21.06 20.87 15.4 1034.98 6803 -12192 8087 -3272 13008 1762 -2849 209 -3218 122 -1930 -242 10918 5657 -4196 4956 -5239 -3808 -2065 -11 89 -1464 494 -926 370 -1953 882 -947 1870 -508 3135 -1170 901 2128 654 1614 392 1232 -759 -1017 -3883 2683 -1860 263 -931 -259 -463 809 -737 -46 -13 -640 -28 -556 1506 -399 1387 -1239 648 -265 -405 -1300 -1140 1438 512 -163 137 292 -116 942 823 -70 -1345 900 24 -568 -379 932 -569 625 188 -648 903 -730 323 -841 -774 -343 42 -509 752 -225 732 223 500 -467 -128 -346 -1111 11 797 242 29 1010 152 -365 -318 -51 176 -372 1 -725 -47 -186 838 -74 150 -504 -823 -563 326 423 -762 1027 142 311 -152 -285 -806 186 58 743 -83 131 -13 46 -331 -105 119 127 58 8 239 24 -198 -153 654 -1545 908 -405 1404 236 -452 36 -639 24 -406 -52 2157 1201 -966 1066 -1322 -992 -548 -3 22 -338 113 -221 93 -542 251 -257 498 -147 1006 -466 400 1020 330 832 206 636 -400 -526 -2006 1317 -947 133 -511 -148 -280 499 -467 -30 -8 -402 -18 -357 1017 -287 1047 -959 464 -179 -266 -903 -873 1173 438 -140 113 231 -82 621 517 -46 -991 727 21 -532 -366 924 -612 694 210 -728 985 -741 306 -761 -676 -316 41 -541 877 -271 879 252 537 -475 -135 -388 -1316 13 984 314 41 1406 216 -513 -415 -63 208 -441 1 -937 -62 -252 1105 -99 191 -605 -979 -632 364 508 -958 1335 191 425 -209 -419 -1211 282 91 1157 -130 198 -19 65 -488 -165 197 218 104 15 463 47 -386 -294