File name: Pandora281s1_CambridgeBay_20260128_L2Fit_fwvt1c2d20240201p1-8.txt File generation date: 20260129T071744.8Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c2p1-8 Local principal investigator: Kimberly Strong Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 281 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora281_OF_v3d20230823.txt Instrument calibration file used: Pandora281s1_CF_v2d20240201.txt Level 1 file used: Pandora281s1_CambridgeBay_20260128_L1_smca1c2d20240201p1-8.txt Full location name: Cambridge Bay, Nunavut: Canadian High Arctic Reseach Station Short location name: CambridgeBay Country of location: Canada Location latitude [deg]: 69.1212 Location longitude [deg]: -105.0398 Location altitude [m]: 10 Local noon date: 20260128 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB based on session 1 First and last pixel inside fitting window: 1621 1770 Nominal wavelengths inside fitting window [nm]: 492.1161 492.2368 492.3574 492.4780 492.5986 492.7192 492.8398 492.9603 493.0808 493.2013 493.3218 493.4423 493.5628 493.6832 493.8036 493.9240 494.0444 494.1648 494.2852 494.4055 494.5258 494.6461 494.7664 494.8867 495.0069 495.1272 495.2474 495.3676 495.4878 495.6080 495.7281 495.8482 495.9684 496.0885 496.2086 496.3286 496.4487 496.5687 496.6887 496.8087 496.9287 497.0487 497.1686 497.2885 497.4085 497.5284 497.6482 497.7681 497.8879 498.0078 498.1276 498.2474 498.3672 498.4869 498.6067 498.7264 498.8461 498.9658 499.0855 499.2051 499.3247 499.4444 499.5640 499.6836 499.8031 499.9227 500.0422 500.1617 500.2812 500.4007 500.5202 500.6396 500.7591 500.8785 500.9979 501.1173 501.2366 501.3560 501.4753 501.5946 501.7139 501.8332 501.9525 502.0717 502.1909 502.3101 502.4293 502.5485 502.6677 502.7868 502.9059 503.0250 503.1441 503.2632 503.3822 503.5013 503.6203 503.7393 503.8583 503.9772 504.0962 504.2151 504.3340 504.4529 504.5718 504.6907 504.8095 504.9284 505.0472 505.1660 505.2847 505.4035 505.5222 505.6410 505.7597 505.8783 505.9970 506.1157 506.2343 506.3529 506.4715 506.5901 506.7087 506.8272 506.9458 507.0643 507.1828 507.3012 507.4197 507.5382 507.6566 507.7750 507.8934 508.0118 508.1301 508.2485 508.3668 508.4851 508.6034 508.7216 508.8399 508.9581 509.0763 509.1945 509.3127 509.4309 509.5490 509.6672 509.7853 509.9034 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20260128T173305.2Z 9524.731310 94 1 54.30 2 89.00 156.29 80.94 32.04 0.00 1 0.00 1 0 15 5.978e-03 5.947e-03 2.736e-04 2.727e-04 3.884997e+03 1.577147e+01 2.794644e+02 -6.000000e+00 3.134411e+02 254.50 -2.00 20.00 -2.00 505.38 0.00e+00 1.589521e-03 7.268078e-06 8.609286e-05 -6.000000e+00 1.607644e-04 254.50 -2.00 20.00 -2.00 501.06 0.00e+00 1.374668e+00 5.434195e-03 4.517449e-02 -6.000000e+00 1.228883e-01 217.00 -2.00 4.87 -2.00 502.56 0.00e+00 19.088 0.209 489.00 513.00 1 3.1984e+00 4.1326e-04 4.0792e-02 -6.0000e+00 9.3715e-03 -2.9571e-02 1.0424e-04 2.4127e-03 -6.0000e+00 2.4162e-03 4.6713e-03 3.8769e-05 3.2338e-05 5.8615e-05 -6.0000e+00 7.3198e-04 3.8705e-03 -1.1395e-04 12 8 8 10 0 0 86.48 26.18 4.18 0.00387 0.00414 159 17 1 4 0 341.450 34.50 20.00 26.18 -23.47 4.3 1052.71 -1222 -844 -288 50 344 786 1064 989 890 597 291 -75 -435 -573 -541 -586 -253 137 219 218 311 409 553 693 781 620 533 168 -511 -763 -783 -663 -237 340 322 -15 -28 -24 -164 -127 -25 136 331 542 761 694 543 305 -23 -573 -918 -1248 -1205 -958 -454 -127 42 180 216 417 650 776 761 675 525 248 91 -130 -368 -561 -598 -452 -427 -108 -26 -470 -776 -837 -814 -815 -792 -775 -793 -635 -380 -410 -510 -376 -298 -146 56 465 689 712 568 372 55 -401 -779 -1000 -1241 -1121 -660 -99 -243 -482 -527 -598 -446 -113 139 331 584 827 958 1191 1343 1235 913 692 520 327 436 572 505 418 574 431 447 476 160 -181 -352 -645 -722 -421 -153 -252 -124 218 242 231 428 384 384 124 -276 -617 -888 -815 -1082 -759 -260 47 322 734 1007 944 849 566 274 -70 -412 -539 -509 -547 -240 130 211 209 301 397 539 678 767 610 521 163 -489 -732 -746 -637 -228 334 317 -15 -27 -24 -161 -125 -25 135 326 540 762 697 544 303 -22 -562 -885 -1211 -1165 -918 -443 -125 42 178 215 417 651 780 767 681 527 246 90 -129 -362 -550 -584 -443 -422 -105 -25 -462 -758 -823 -795 -796 -776 -765 -777 -628 -379 -412 -507 -374 -298 -146 56 474 695 719 570 374 54 -397 -759 -967 -1203 -1104 -655 -99 -248 -491 -537 -607 -451 -115 142 345 605 864 1009 1242 1408 1300 962 724 539 343 454 597 522 435 598 450 467 497 167 -188 -362 -662 -745 -438 -162 -268 -131 234 263 250 464 419 419 135 -298 -669 -954 -873 SQ 20260128T180406.0Z 9524.752847 131 1 53.81 2 88.05 163.60 79.37 38.56 0.00 1 0.00 1 15 0 -9.000e+00 -9.000e+00 -9.000e+00 -9.000e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 254.50 -2.00 20.00 -2.00 -9.00 0.00e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 254.50 -2.00 20.00 -2.00 -9.00 0.00e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 217.00 -2.00 4.87 -2.00 -9.00 0.00e+00 16.439 0.134 489.00 513.00 1 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -1.3217e-03 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 0.0000e+00 0.0000e+00 12 11 11 12 8 8 -82.60 26.18 -21.00 0.00000 -9.00000 38 4 1 4 0 1415.910 34.50 19.98 26.18 -24.11 4.3 1046.04 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 SQ 20260128T181943.6Z 9524.763698 156 1 54.10 2 87.69 167.30 78.49 41.84 0.00 1 0.00 1 0 15 4.070e-03 4.055e-03 1.361e-04 1.359e-04 2.351861e+03 7.590630e+00 1.730039e+02 -6.000000e+00 2.134348e+02 254.50 -2.00 20.00 -2.00 505.34 0.00e+00 1.225378e-03 3.606548e-06 6.502809e-05 -6.000000e+00 1.094718e-04 254.50 -2.00 20.00 -2.00 500.88 0.00e+00 1.370333e+00 2.724492e-03 2.925701e-02 -6.000000e+00 8.368131e-02 217.00 -2.00 4.87 -2.00 502.41 0.00e+00 15.462 0.111 489.00 513.00 1 2.3480e+00 2.0735e-04 2.7407e-02 -6.0000e+00 6.3816e-03 -1.3575e-02 5.2693e-05 1.6084e-03 -6.0000e+00 1.6453e-03 1.8424e-02 -2.2711e-04 1.6217e-05 4.0654e-05 -6.0000e+00 4.9845e-04 -6.6705e-04 -8.7667e-05 11 8 0 10 0 0 93.27 26.18 2.64 -0.00067 -0.00224 521 56 1 4 0 103.820 34.50 20.01 26.18 -23.51 4.4 1057.78 -810 -526 -187 -68 107 525 721 671 516 346 242 -35 -349 -409 -420 -427 -215 80 160 -10 94 258 344 519 629 467 401 108 -336 -515 -381 -400 -84 388 258 -141 -90 5 -84 -103 17 116 213 392 492 481 379 248 -36 -362 -649 -815 -888 -684 -294 -89 -52 -11 68 225 475 548 502 457 333 186 65 -29 -221 -387 -348 -306 -285 -32 44 -278 -531 -530 -471 -507 -425 -506 -554 -392 -197 -283 -381 -279 -155 -86 50 418 566 492 360 293 58 -288 -508 -677 -815 -787 -407 -44 -169 -415 -457 -463 -300 -8 116 180 347 501 569 745 914 830 614 505 337 197 333 500 393 297 375 326 325 398 171 -165 -286 -493 -598 -327 -104 -215 -202 34 91 145 281 349 271 119 -168 -449 -562 -509 -740 -488 -175 -65 103 508 708 655 504 335 235 -34 -333 -394 -404 -409 -209 78 157 -10 94 256 343 518 630 468 399 107 -330 -504 -370 -391 -83 385 258 -142 -90 5 -83 -102 17 116 216 395 499 489 383 248 -36 -355 -632 -792 -861 -660 -290 -89 -52 -11 68 226 477 552 506 461 334 187 64 -29 -218 -379 -340 -300 -281 -31 44 -274 -519 -519 -457 -492 -413 -496 -541 -386 -195 -280 -379 -278 -154 -85 50 421 567 495 361 293 58 -281 -495 -653 -787 -770 -403 -44 -171 -418 -459 -468 -302 -8 117 185 356 518 588 773 952 866 639 522 345 203 340 512 404 303 383 334 333 407 174 -169 -290 -499 -607 -330 -107 -223 -210 36 95 153 299 372 286 126 -177 -472 -584 -527 SQ 20260128T192339.2Z 9524.808092 257 1 54.33 2 87.18 182.50 74.32 55.19 0.00 1 0.00 1 0 22 9.100e-03 9.143e-03 2.483e-04 2.481e-04 2.677513e+03 1.402861e+01 2.342703e+02 -6.000000e+00 4.771828e+02 254.50 -2.00 20.00 -2.00 505.34 0.00e+00 2.237446e-04 6.574876e-06 2.129068e-05 -6.000000e+00 2.447268e-04 254.50 -2.00 20.00 -2.00 500.82 0.00e+00 9.325507e-01 4.976146e-03 1.848786e-02 -6.000000e+00 1.870367e-01 217.01 -2.00 4.87 -2.00 502.36 0.00e+00 14.113 0.084 489.00 513.00 1 3.7820e+00 3.7876e-04 2.3605e-02 -6.0000e+00 1.4264e-02 -2.6856e-03 9.6091e-05 1.3805e-03 -6.0000e+00 3.6760e-03 5.5682e-03 3.5502e-03 2.9415e-05 4.0984e-05 -6.0000e+00 1.1142e-03 -6.4958e-03 -2.3675e-05 12 8 8 10 0 0 92.23 26.20 2.27 -0.00650 0.01813 137 15 3 4 0 396.550 34.50 19.99 26.20 -21.73 4.3 1070.74 -1748 -1533 -1437 -1581 -1494 -1023 -652 -483 -402 -359 -168 -232 -303 -281 -224 -266 -7 353 411 279 353 509 541 887 1148 1030 1030 519 -232 -575 -414 -244 355 872 682 130 -18 -186 -618 -885 -941 -969 -909 -686 -377 -260 25 412 683 644 624 524 336 319 535 674 687 768 893 1068 1317 1191 865 556 31 -457 -799 -770 -705 -314 496 1204 1685 1836 1697 701 69 -229 -417 -612 -481 -262 -121 69 84 -344 -845 -1063 -1018 -673 -47 777 1398 1520 1580 1601 1130 387 -211 -563 -461 9 614 1064 545 -202 -470 -579 -396 -28 294 427 425 486 482 612 737 681 373 57 -368 -776 -984 -1022 -1082 -1150 -961 -965 -1110 -1220 -1542 -1865 -1730 -1599 -1338 -725 -108 127 623 1368 1761 1968 1950 1658 1069 213 -822 -1599 -1710 -1191 -1641 -1444 -1371 -1532 -1461 -1017 -644 -478 -396 -356 -165 -224 -294 -272 -217 -256 -7 348 412 278 355 512 546 895 1158 1037 1029 513 -230 -561 -401 -239 348 874 686 132 -18 -188 -620 -889 -949 -985 -920 -700 -385 -265 26 415 672 629 605 502 322 310 523 665 689 765 892 1067 1317 1197 873 561 31 -456 -791 -764 -691 -305 484 1172 1648 1784 1655 686 67 -221 -401 -591 -466 -255 -118 67 83 -343 -839 -1062 -1021 -677 -48 786 1395 1536 1580 1574 1108 375 -204 -544 -447 9 601 1065 551 -204 -473 -587 -401 -28 297 437 434 501 501 631 761 704 385 59 -378 -795 -1007 -1049 -1116 -1174 -980 -984 -1133 -1242 -1585 -1904 -1746 -1605 -1346 -735 -111 131 648 1409 1823 2049 2042 1725 1117 223 -856 -1675 -1772 -1227 SQ 20260128T200626.2Z 9524.837803 324 1 28.41 2 87.67 192.66 71.11 64.14 0.00 1 0.00 1 0 15 4.008e-03 3.992e-03 1.358e-04 1.357e-04 2.227169e+03 7.548117e+00 1.634563e+02 -6.000000e+00 2.101579e+02 254.50 -2.00 20.00 -2.00 505.34 0.00e+00 9.316083e-04 3.596472e-06 5.036676e-05 -6.000000e+00 1.077875e-04 254.50 -2.00 20.00 -2.00 500.86 0.00e+00 1.449511e+00 2.718718e-03 2.779404e-02 -6.000000e+00 8.239084e-02 217.01 -2.00 4.87 -2.00 502.40 0.00e+00 15.400 0.110 489.00 513.00 1 1.7096e+00 2.0688e-04 2.7196e-02 -6.0000e+00 6.2832e-03 -1.2818e-02 5.2609e-05 1.5899e-03 -6.0000e+00 1.6198e-03 3.5135e-02 -3.8905e-04 1.6167e-05 3.5044e-05 -6.0000e+00 4.9077e-04 -3.5172e-04 -8.3082e-05 11 8 0 10 0 0 96.38 26.20 2.62 -0.00035 -0.00305 503 54 1 4 0 56.470 34.25 20.00 26.20 -22.54 4.4 1070.58 -779 -518 -192 -71 102 516 724 647 486 379 220 -19 -338 -412 -372 -420 -253 94 156 -28 68 254 349 523 593 447 377 122 -302 -492 -370 -397 -85 387 229 -168 -82 46 -91 -83 29 104 209 361 481 449 359 264 -12 -371 -658 -808 -852 -654 -284 -63 -32 -19 47 225 459 541 500 433 358 203 45 -56 -222 -377 -359 -262 -273 -14 60 -301 -559 -542 -488 -478 -428 -482 -567 -362 -205 -260 -366 -276 -171 -105 64 388 593 474 345 271 51 -255 -502 -672 -826 -785 -387 -18 -142 -426 -437 -461 -293 17 118 160 321 491 551 749 908 833 596 481 350 201 347 500 359 299 387 314 339 416 149 -177 -293 -473 -591 -316 -74 -233 -166 -5 63 145 310 327 286 119 -153 -479 -577 -461 -718 -479 -180 -67 98 500 711 632 475 372 214 -19 -327 -396 -358 -402 -247 92 154 -28 67 253 348 524 596 449 377 120 -297 -482 -359 -388 -84 385 230 -171 -83 46 -91 -82 29 105 210 365 488 457 364 265 -12 -368 -640 -784 -824 -638 -279 -63 -32 -19 47 226 461 545 505 436 359 204 45 -55 -219 -369 -349 -255 -269 -14 59 -296 -545 -528 -473 -462 -415 -471 -554 -356 -203 -257 -364 -275 -171 -104 64 392 596 478 346 271 51 -250 -488 -648 -797 -768 -382 -18 -143 -430 -440 -467 -296 17 119 162 330 503 569 778 937 861 615 498 359 204 355 512 366 306 397 322 347 425 152 -180 -297 -478 -600 -320 -76 -242 -174 -6 66 152 327 346 303 126 -162 -500 -601 -478 SQ 20260128T200654.8Z 9524.838134 324 2 28.41 2 87.68 192.78 71.07 64.24 0.00 1 0.00 1 0 15 4.048e-03 4.034e-03 1.364e-04 1.362e-04 2.238903e+03 7.582962e+00 1.638872e+02 -6.000000e+00 2.122602e+02 254.50 -2.00 20.00 -2.00 505.34 0.00e+00 9.612428e-04 3.613045e-06 5.175917e-05 -6.000000e+00 1.088740e-04 254.50 -2.00 20.00 -2.00 500.87 0.00e+00 1.446970e+00 2.729908e-03 2.793404e-02 -6.000000e+00 8.323533e-02 217.01 -2.00 4.87 -2.00 502.40 0.00e+00 15.425 0.110 489.00 513.00 1 1.7135e+00 2.0770e-04 2.7272e-02 -6.0000e+00 6.3474e-03 -1.2887e-02 5.2839e-05 1.5944e-03 -6.0000e+00 1.6370e-03 3.4865e-02 1.4957e-04 1.6242e-05 3.5357e-05 -6.0000e+00 4.9573e-04 -5.0193e-03 -7.7955e-05 11 8 0 10 0 0 43.91 26.20 2.64 -0.00502 -0.00398 503 54 1 4 0 56.470 34.25 19.99 26.20 -22.54 4.4 1071.04 -783 -507 -189 -69 96 525 747 664 533 375 219 -63 -348 -421 -397 -426 -252 89 170 29 107 239 353 550 594 426 379 116 -294 -505 -390 -391 -87 347 221 -140 -60 36 -91 -120 3 103 207 379 502 455 368 261 -10 -360 -663 -808 -882 -664 -300 -79 -75 -20 60 226 437 557 492 447 361 214 63 -44 -219 -372 -330 -299 -263 -21 31 -305 -552 -525 -471 -492 -409 -485 -561 -405 -224 -303 -369 -291 -167 -95 44 391 579 462 343 291 42 -298 -489 -678 -840 -784 -367 -19 -171 -440 -442 -458 -296 9 134 184 331 513 577 763 921 848 585 462 334 223 311 501 390 292 387 313 350 411 139 -176 -293 -508 -583 -260 -83 -217 -204 -32 82 142 295 347 298 145 -152 -470 -558 -511 -720 -467 -176 -66 92 507 731 655 525 367 212 -61 -336 -404 -381 -412 -244 86 168 29 107 238 352 549 595 427 377 116 -289 -494 -378 -381 -85 344 221 -141 -61 36 -91 -119 3 103 209 381 509 462 372 261 -10 -357 -652 -782 -851 -646 -294 -78 -75 -21 60 228 443 559 495 450 361 214 63 -44 -215 -363 -321 -292 -259 -21 30 -299 -544 -511 -455 -475 -396 -473 -553 -398 -221 -299 -366 -289 -166 -95 44 393 587 465 348 291 42 -291 -475 -660 -808 -766 -362 -19 -173 -444 -449 -463 -298 9 135 188 339 531 595 792 959 885 608 477 341 228 318 512 400 298 396 320 358 420 142 -181 -297 -513 -591 -262 -85 -225 -212 -34 86 150 311 367 316 153 -160 -489 -580 -529