File name: Pandora184s1_CapeElizabethME_20210708_L2Fit_fsus1c1d20210422p1-8.txt File generation date: 20260323T190210.3Z Data description: Level 2 spectral fitting results file Data file version: fsus1c1p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 184 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora184_OF_v4d20201127.txt Instrument calibration file used: Pandora184s1_CF_v1d20210422.txt Level 1 file used: Pandora184s1_CapeElizabethME_20210708_L1_smca1c1d20210422p1-8.txt.bz2 Full location name: CEPTL - Cape Elizabeth Two Lights (State Park) Maine Short location name: CapeElizabethME Country of location: United States Location latitude [deg]: 43.5610 Location longitude [deg]: -70.2073 Location altitude [m]: 24 Local noon date: 20210708 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 203 348 Nominal wavelengths inside fitting window [nm]: 306.0010 306.1420 306.2830 306.4239 306.5649 306.7058 306.8468 306.9877 307.1286 307.2695 307.4104 307.5513 307.6922 307.8330 307.9739 308.1147 308.2555 308.3964 308.5372 308.6780 308.8187 308.9595 309.1003 309.2410 309.3818 309.5225 309.6632 309.8039 309.9446 310.0853 310.2260 310.3667 310.5073 310.6480 310.7886 310.9292 311.0698 311.2104 311.3510 311.4916 311.6322 311.7727 311.9133 312.0538 312.1943 312.3348 312.4753 312.6158 312.7563 312.8968 313.0372 313.1777 313.3181 313.4586 313.5990 313.7394 313.8798 314.0202 314.1605 314.3009 314.4412 314.5816 314.7219 314.8622 315.0025 315.1428 315.2831 315.4234 315.5637 315.7039 315.8441 315.9844 316.1246 316.2648 316.4050 316.5452 316.6854 316.8255 316.9657 317.1058 317.2459 317.3861 317.5262 317.6663 317.8063 317.9464 318.0865 318.2265 318.3666 318.5066 318.6466 318.7866 318.9266 319.0666 319.2066 319.3466 319.4865 319.6265 319.7664 319.9063 320.0462 320.1861 320.3260 320.4659 320.6057 320.7456 320.8854 321.0252 321.1651 321.3049 321.4447 321.5845 321.7242 321.8640 322.0037 322.1435 322.2832 322.4229 322.5626 322.7023 322.8420 322.9817 323.1213 323.2610 323.4006 323.5402 323.6799 323.8195 323.9591 324.0986 324.2382 324.3778 324.5173 324.6569 324.7964 324.9359 325.0754 325.2149 325.3544 325.4938 325.6333 325.7727 325.9122 326.0516 326.1910 326.3304 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20210708T145900.2Z 7859.624308 7 1 44.68 2 30.59 125.13 20.18 154.49 0.00 1 0.00 1 0 49 1.015e-03 6.164e-04 1.044e-03 5.794e-04 -2.092490e-07 2.285505e-07 1.278248e-08 3.779676e-07 4.902740e-07 233.10 -2.00 3.57 -2.00 321.34 0.00e+00 4.262056e-04 7.777553e-05 9.341643e-06 1.401145e-05 1.279217e-04 287.11 -2.00 20.00 -2.00 321.24 0.00e+00 3.465172e-04 1.121790e-04 2.395293e-06 2.473916e-05 2.198505e-04 287.11 -2.00 20.00 -2.00 321.27 0.00e+00 1.230569e-04 1.437773e-04 1.213533e-05 1.535056e-05 2.296192e-04 287.11 -2.00 20.00 -2.00 321.22 0.00e+00 1.575172e-01 8.067688e-04 4.404266e-05 2.317488e-03 1.274762e-03 240.06 1.31 0.00 0.76 2.25 317.04 0.00e+00 2.753372e-05 3.920396e-05 1.105518e-05 2.633622e-05 3.393869e-05 287.11 -2.00 20.00 -2.00 315.82 0.00e+00 1.161 0.000 303.00 329.40 4 2.7724e+00 2.5486e-03 1.1269e-02 1.9171e-03 4.0771e-03 7.4395e-03 3.1628e-03 1.1940e-03 3.3487e-04 4.3473e-03 -9.2187e-04 1.6747e-03 1.5217e-04 1.1487e-04 2.4266e-03 -5.1378e-05 5.8840e-04 3.2845e-05 2.9784e-05 8.8218e-04 1.5622e-03 4.3487e-04 2.9471e-05 4.2634e-05 5.9184e-04 1.0248e-02 7.7198e-04 5.6486e-04 5.0322e-05 2.4980e-05 5.7662e-04 2.9475e-04 1.8552e-05 1.4012e-06 8.7092e-07 3.3506e-05 1.0208e-03 5.5662e-05 4.7487e-01 6.9026e-02 2.4420e-03 7.0047e-04 1.0078e-01 10 0 0 10 0 0 99.98 23.03 0.39 0.00102 0.00327 738 206 1 5 0 60.530 26.94 19.99 23.03 26.03 7.9 992.37 900000 -200 286 249 207 -66 245 -49 -218 -224 42 -271 66 0 -81 -170 7 -142 176 -272 156 -3 273 127 230 -40 83 21 287 -34 -93 -157 143 -80 47 37 -61 18 66 -46 102 43 118 7 -94 -95 54 36 8 70 -102 -60 -126 19 -28 -10 -19 25 -35 7 -14 0 -105 -1 -91 43 -17 54 46 214 4 80 -71 -17 -2 -42 -133 68 -69 55 25 90 -19 17 -7 -90 -82 35 -47 -23 156 124 -26 1 37 7 84 2 -66 -78 16 -42 2 28 88 -17 -19 -1 -23 -32 -14 -33 -1 -22 79 -49 -29 -37 -26 -82 66 -5 11 -88 31 -45 3 -19 3 43 125 3 -10 -65 -15 53 -36 -31 -10 71 -2 46 10 -4 -23 -38 900000 -40 60 53 43 -14 59 -13 -63 -68 13 -85 21 0 -27 -61 2 -55 70 -109 60 -1 91 42 80 -15 32 8 103 -13 -40 -78 83 -47 28 23 -38 11 41 -31 66 27 72 4 -61 -64 38 26 6 52 -77 -44 -93 15 -22 -8 -16 20 -29 5 -10 0 -86 -1 -86 37 -16 48 37 155 2 55 -53 -14 -2 -41 -135 66 -72 60 28 103 -21 18 -7 -85 -73 31 -46 -25 166 140 -30 1 41 7 90 2 -74 -91 19 -53 2 38 121 -23 -23 -1 -26 -36 -16 -42 -1 -28 101 -61 -35 -46 -31 -92 73 -6 14 -112 40 -60 3 -25 4 61 182 4 -14 -91 -20 72 -49 -44 -16 118 -4 86 19 -8 -43 -71 SS 20210708T151847.0Z 7859.638044 22 1 47.01 2 27.80 132.56 19.00 167.12 0.00 1 0.00 1 0 49 3.876e-03 2.228e-03 3.908e-03 2.135e-03 -7.877313e-07 8.381994e-07 3.808040e-08 3.779531e-07 1.873509e-06 233.10 -2.00 3.57 -2.00 321.25 0.00e+00 2.820715e-04 2.806449e-04 2.229401e-05 1.404159e-05 4.891738e-04 287.11 -2.00 20.00 -2.00 321.03 0.00e+00 -6.991633e-05 4.065337e-04 1.438733e-05 2.474908e-05 8.226955e-04 287.11 -2.00 20.00 -2.00 321.23 0.00e+00 1.054919e-03 5.230011e-04 5.928960e-05 1.534629e-05 8.763889e-04 287.11 -2.00 20.00 -2.00 321.14 0.00e+00 1.555015e-01 2.946257e-03 1.095790e-04 2.317433e-03 4.831844e-03 240.82 4.85 0.00 0.77 8.38 317.02 0.00e+00 9.925686e-05 1.452011e-04 1.247731e-05 2.633437e-05 1.263857e-04 287.11 -2.00 20.00 -2.00 315.84 0.00e+00 1.130 0.000 303.00 329.40 4 5.2530e+00 9.4792e-03 1.0988e-02 1.9168e-03 1.5515e-02 2.0415e-02 1.1628e-02 1.3361e-03 3.3422e-04 1.6415e-02 5.8693e-03 6.0826e-03 2.8273e-04 1.1607e-04 9.2649e-03 -3.1331e-03 2.1344e-03 8.8143e-05 2.9107e-05 3.3532e-03 1.3416e-03 1.5727e-03 8.3562e-05 4.1880e-05 2.2090e-03 8.7143e-04 -7.8055e-03 2.0547e-03 7.1957e-05 2.5585e-05 2.2570e-03 2.8661e-04 6.7899e-05 1.3340e-06 8.8979e-07 1.2729e-04 8.6431e-04 4.1744e-05 8.7468e-01 2.5338e-01 4.5950e-03 7.0449e-04 3.8568e-01 12 8 8 10 0 0 99.97 23.04 0.55 0.00086 0.00305 55 15 1 5 0 854.680 26.94 20.01 23.04 25.50 7.8 987.81 -1998 733 95 1150 982 -237 -1090 -266 -356 -611 146 -651 -487 85 80 560 -18 583 923 -258 949 -109 820 599 118 8 458 -683 633 -678 432 251 -345 -703 353 -581 93 -339 93 193 94 374 65 -161 -191 38 33 -128 -47 -4 -229 67 -172 227 -59 160 -194 -128 -241 283 74 -56 33 249 -266 183 -122 -51 -167 41 -33 272 -39 208 -297 235 -111 129 -215 31 259 305 -165 -11 -51 -296 -10 -226 -32 -61 238 375 -143 443 -144 191 349 -300 -312 -229 -14 -3 91 57 150 43 246 -285 -137 -357 -63 -24 -53 -59 -91 185 386 -205 261 -395 -64 -272 -29 -303 95 40 137 -112 106 64 101 -59 36 -178 52 267 -244 -28 272 270 -18 -22 133 -277 -114 64 -379 149 21 250 211 -54 -274 -73 -106 -190 45 -209 -160 28 27 185 -6 207 337 -96 334 -40 279 204 42 3 179 -264 232 -263 187 126 -184 -414 216 -366 59 -214 58 130 61 233 40 -100 -125 26 23 -94 -35 -3 -172 49 -127 170 -47 135 -157 -115 -203 216 54 -42 27 221 -250 174 -113 -44 -134 30 -22 183 -29 170 -267 225 -112 136 -243 34 288 342 -180 -12 -52 -277 -9 -203 -31 -65 273 458 -176 514 -157 198 365 -340 -377 -289 -18 -4 117 76 200 55 324 -347 -156 -398 -72 -29 -69 -81 -125 246 491 -248 299 -435 -69 -306 -34 -376 120 51 182 -155 154 96 142 -83 50 -266 75 381 -357 -43 406 431 -31 -39 244 -514 -209 116 SS 20210708T154704.0Z 7859.657686 35 1 46.68 2 24.43 145.33 18.71 186.59 0.00 1 0.00 1 0 49 1.668e-02 8.288e-03 1.108e-02 5.982e-03 6.020947e-06 2.368702e-06 9.521530e-08 3.780020e-07 8.025110e-06 233.10 -2.00 3.57 -2.00 321.44 0.00e+00 8.296281e-05 8.194866e-04 2.975681e-05 1.409342e-05 2.090693e-03 287.11 -2.00 20.00 -2.00 321.39 0.00e+00 -4.705319e-04 1.148717e-03 2.859865e-05 2.472429e-05 3.606557e-03 287.11 -2.00 20.00 -2.00 321.36 0.00e+00 3.035272e-04 1.626756e-03 9.082728e-05 1.533102e-05 3.772531e-03 287.11 -2.00 20.00 -2.00 321.35 0.00e+00 1.492827e-01 8.174766e-03 3.917418e-04 2.317150e-03 2.092461e-02 212.79 12.93 0.00 0.83 37.04 317.21 0.00e+00 -2.604601e-04 4.207612e-04 1.443271e-04 2.632982e-05 5.568795e-04 287.11 -2.00 20.00 -2.00 316.06 0.00e+00 1.098 0.000 303.00 329.40 4 6.7718e+00 2.0718e-02 1.0744e-02 1.9154e-03 6.7234e-02 4.6263e-03 2.7885e-02 3.4081e-03 3.2902e-04 7.1433e-02 1.5345e-02 1.5793e-02 9.8585e-04 1.1514e-04 3.9786e-02 -1.1781e-02 6.0378e-03 7.8317e-05 2.8714e-05 1.4432e-02 8.8411e-03 4.5271e-03 1.8988e-04 4.2237e-05 9.7145e-03 2.0533e-04 -5.3208e-03 6.1379e-03 5.7440e-05 2.6644e-05 9.5387e-03 6.8964e-04 1.9771e-04 1.9336e-06 8.8365e-07 5.5232e-04 1.1753e-03 1.0847e-04 2.8309e+00 7.2688e-01 3.5356e-03 7.2832e-04 1.6408e+00 12 9 9 12 1 1 99.94 23.04 0.59 0.00118 0.00644 14 4 1 5 0 3111.290 26.94 20.01 23.04 25.44 7.9 988.62 900000 -2419 8860 -7783 2073 1572 3973 66 -1082 -2675 -3557 2528 1193 3484 1609 -1024 3014 -826 -1840 -2662 2101 -1121 5364 -496 2500 -3086 567 -374 73 -1759 1139 -1075 -1722 279 -193 -135 631 -696 106 -1751 -1126 -36 416 -13 -243 -520 -613 2048 -968 621 -302 1397 1017 2070 -489 1902 558 273 301 -220 186 -670 -1067 732 1216 -1196 536 1436 580 -214 -1554 -401 -498 -1652 117 -1272 308 471 1046 -47 805 -477 -691 -1564 -1418 -1346 -1199 154 -1329 580 2 452 -499 331 877 406 550 -134 537 -69 509 -1009 1104 423 162 1030 -75 456 377 -816 -297 -736 -632 638 17 -375 392 -255 914 353 -595 779 -611 -1722 899 382 -36 419 -75 -42 -462 -49 -800 216 -171 -42 -320 645 185 1022 -630 0 -803 35 566 82 900000 -495 1734 -1824 437 348 941 18 -320 -842 -1141 780 380 1105 522 -341 996 -296 -688 -1009 730 -373 1591 -155 789 -1079 199 -130 24 -626 442 -494 -922 161 -118 -84 395 -438 66 -1081 -668 -20 230 -7 -144 -322 -396 1326 -655 417 -205 920 668 1370 -349 1411 440 217 226 -152 134 -496 -865 582 1111 -1029 486 1221 455 -153 -1053 -269 -362 -1354 103 -1218 303 489 1147 -55 958 -579 -816 -1742 -1441 -1251 -1050 136 -1280 600 2 540 -599 376 926 411 563 -148 629 -85 648 -1354 1509 604 233 1411 -97 537 414 -890 -333 -881 -807 836 23 -486 484 -300 1011 376 -631 846 -710 -2110 1102 476 -46 563 -106 -61 -692 -73 -1194 311 -240 -57 -450 945 293 1716 -1144 0 -1575 69 1092 157 SS 20210708T155513.1Z 7859.663346 41 1 1.46 2 23.64 149.53 18.94 192.14 0.00 1 0.00 1 0 49 1.329e-03 9.447e-04 1.266e-03 9.708e-04 -2.790565e-07 3.934295e-07 1.612066e-08 3.778746e-07 6.414132e-07 233.10 -2.00 3.57 -2.00 320.23 0.00e+00 2.060350e-04 1.222677e-04 6.958646e-06 1.394323e-05 1.674485e-04 287.11 -2.00 20.00 -2.00 319.77 0.00e+00 1.513540e-04 1.834993e-04 7.350069e-06 2.484563e-05 2.819077e-04 287.11 -2.00 20.00 -2.00 320.53 0.00e+00 5.751652e-04 2.175137e-04 2.699511e-05 1.527394e-05 3.006646e-04 287.11 -2.00 20.00 -2.00 320.16 0.00e+00 1.466130e-01 1.216087e-03 2.932502e-05 2.316812e-03 1.657669e-03 237.08 2.11 0.00 0.81 2.88 315.33 0.00e+00 4.989921e-05 4.764543e-05 9.646944e-07 2.630574e-05 4.335894e-05 287.11 -2.00 20.00 -2.00 314.31 0.00e+00 1.091 0.000 303.00 329.40 4 1.2780e+00 4.0102e-03 1.0597e-02 1.9139e-03 5.3214e-03 -6.9460e-03 4.6130e-03 1.1160e-03 3.1449e-04 5.6411e-03 1.0495e-03 2.4627e-03 1.0831e-04 9.2905e-05 3.1773e-03 -2.8199e-04 8.5747e-04 4.0664e-05 2.0383e-05 1.1457e-03 1.1598e-03 6.4272e-04 2.8476e-05 3.3709e-05 7.5728e-04 4.9512e-02 3.4016e-03 7.7281e-04 1.6437e-05 1.9338e-05 7.5229e-04 7.6113e-05 2.9872e-05 1.0545e-06 8.4109e-07 4.3539e-05 1.6136e-03 2.7671e-05 3.0376e-01 1.0849e-01 1.3871e-03 7.9457e-04 1.3356e-01 12 1 1 12 1 1 79.52 23.05 0.40 0.00161 0.00219 28 275 1 5 0 44.510 26.94 19.99 23.05 26.03 8.0 993.75 624 -286 130 76 486 50 108 -302 -73 -74 121 -395 1 89 172 -139 -47 -184 -70 -161 -89 21 106 80 -75 -17 -40 -344 -22 318 -188 143 5 154 -140 58 16 -39 -138 124 26 153 115 165 -107 62 30 59 71 144 163 -6 -328 -70 -87 101 -60 42 -59 118 -101 119 6 98 -84 -87 -99 12 22 60 -110 -154 6 24 -62 -30 7 83 -1 84 41 2 0 -25 -65 -217 72 -24 77 12 110 -81 -80 141 65 -102 -27 2 26 -125 -89 45 -27 123 -7 -13 109 -68 75 -33 -117 25 -88 64 92 43 95 -11 -37 -7 -26 136 -65 29 35 -119 -120 -74 4 6 31 50 -14 -41 112 127 -186 -4 -25 41 -16 37 22 -27 -50 36 203 -104 50 29 185 20 48 -136 -35 -37 61 -206 1 45 93 -75 -25 -99 -39 -90 -47 11 53 40 -39 -9 -23 -193 -12 178 -111 92 4 118 -113 48 12 -32 -113 99 20 113 84 121 -83 50 26 48 59 120 137 -5 -271 -59 -77 90 -56 39 -55 101 -87 104 6 92 -83 -87 -96 11 20 52 -88 -123 5 22 -58 -30 7 88 -2 96 48 2 0 -28 -66 -215 70 -23 79 13 120 -94 -93 156 71 -106 -28 3 30 -151 -106 56 -35 157 -9 -17 131 -78 86 -37 -135 29 -105 79 114 52 116 -13 -43 -8 -28 154 -74 35 43 -147 -145 -94 6 7 42 68 -19 -54 149 167 -250 -6 -34 61 -25 57 35 -43 -78 56 SS 20210708T155954.7Z 7859.666606 44 1 1.09 2 23.22 152.05 19.13 195.28 0.00 1 0.00 1 0 33 7.067e-03 5.003e-03 6.383e-03 4.895e-03 -5.839666e-07 1.989114e-06 5.658292e-08 3.778635e-07 3.406399e-06 233.10 -2.00 3.57 -2.00 320.18 0.00e+00 1.789440e-03 6.216547e-04 3.052786e-05 1.394826e-05 8.944458e-04 287.11 -2.00 20.00 -2.00 319.71 0.00e+00 -8.394299e-04 9.248934e-04 1.459075e-05 2.483370e-05 1.500807e-03 287.11 -2.00 20.00 -2.00 320.49 0.00e+00 -2.455193e-04 1.110426e-03 1.817015e-05 1.525833e-05 1.598278e-03 287.11 -2.00 20.00 -2.00 320.12 0.00e+00 1.400855e-01 6.091584e-03 1.344040e-04 2.316652e-03 8.808766e-03 229.53 10.86 0.00 0.84 15.29 315.30 0.00e+00 -4.870684e-05 2.394816e-04 4.697261e-05 2.630753e-05 2.305813e-04 287.11 -2.00 20.00 -2.00 314.30 0.00e+00 1.088 0.000 303.00 329.40 4 3.5236e+00 1.8875e-02 1.0572e-02 1.9141e-03 2.8275e-02 -7.8844e-03 2.2202e-02 1.4402e-03 3.1514e-04 2.9956e-02 2.1765e-02 1.2191e-02 5.0300e-04 9.3893e-05 1.6918e-02 -4.5372e-03 4.2914e-03 9.6583e-05 2.0329e-05 6.0789e-03 -5.4063e-03 3.2389e-03 9.4474e-05 3.3826e-05 4.0346e-03 5.3740e-03 6.6379e-03 4.0040e-03 1.4780e-04 1.9791e-05 4.0492e-03 1.7635e-04 1.5011e-04 3.7163e-06 8.3860e-07 2.3095e-04 6.8687e-04 -2.5741e-05 3.4373e-01 5.4909e-01 7.3473e-03 7.7902e-04 7.1356e-01 12 9 9 12 1 1 999.00 23.05 0.22 0.00069 0.00203 1 28 1 5 0 459.300 26.94 20.01 23.05 26.69 7.9 998.43 936 -2656 -435 -379 -481 1142 1750 -633 -2032 171 1209 1356 -339 -243 -704 546 -705 1301 -123 1241 -1666 869 1106 908 -1513 -55 1209 576 -1211 552 -1803 458 -15 369 -643 214 73 437 -888 304 -349 1504 -1452 -1104 -550 952 -431 1018 436 102 -592 205 -901 -120 833 466 -268 33 223 -60 -297 391 267 -119 253 -196 196 -408 721 462 -55 -68 688 -298 121 -855 -106 -775 522 -556 241 -323 -243 -287 81 -335 274 -1663 728 -196 552 287 -50 -147 91 -155 29 538 -199 -11 205 324 7 501 -51 513 -646 717 -333 574 -206 127 -111 411 392 -204 -402 107 -62 -35 99 -19 -426 -655 -118 186 -380 -134 -32 489 -446 118 -179 -64 217 119 -382 49 8 201 -126 -5 22 220 -166 165 326 -973 -166 -146 -182 444 744 -281 -989 85 598 683 -177 -129 -376 287 -387 731 -67 723 -956 449 537 439 -782 -30 667 312 -640 300 -1054 306 -11 276 -511 172 59 351 -718 237 -264 1146 -1115 -854 -417 745 -356 852 372 88 -519 176 -776 -105 754 425 -259 32 202 -52 -247 329 248 -115 241 -191 196 -388 658 381 -46 -56 573 -280 117 -843 -109 -843 566 -643 286 -368 -283 -313 84 -339 258 -1633 752 -212 610 339 -59 -165 100 -163 31 585 -232 -14 246 402 9 640 -66 665 -787 830 -384 641 -228 149 -133 511 488 -249 -498 125 -69 -39 109 -22 -490 -787 -144 230 -462 -171 -40 639 -603 160 -241 -84 290 156 -491 65 11 297 -190 -7 35 343 -258 251 SS 20210708T162722.5Z 7859.685678 59 1 46.29 2 21.52 168.18 21.09 212.12 0.00 1 0.00 1 0 49 1.452e-03 9.519e-04 1.355e-03 8.565e-04 -2.246502e-07 3.403726e-07 2.022520e-08 3.779376e-07 7.012656e-07 233.10 -2.00 3.57 -2.00 321.02 0.00e+00 7.976773e-04 1.124287e-04 1.389756e-05 1.400091e-05 1.834528e-04 287.12 -2.00 20.00 -2.00 320.77 0.00e+00 -1.752943e-04 1.642713e-04 4.373211e-06 2.474990e-05 3.156793e-04 287.12 -2.00 20.00 -2.00 321.06 0.00e+00 2.430230e-04 2.072551e-04 1.898900e-05 1.533179e-05 3.284696e-04 287.12 -2.00 20.00 -2.00 320.91 0.00e+00 1.467221e-01 1.159481e-03 6.729978e-05 2.317170e-03 1.818284e-03 238.27 2.02 0.00 0.81 3.22 316.53 0.00e+00 -1.546567e-05 5.178518e-05 1.730518e-05 2.632152e-05 4.850302e-05 287.12 -2.00 20.00 -2.00 315.37 0.00e+00 1.075 0.000 303.00 329.40 4 3.8469e+00 3.6483e-03 1.0433e-02 1.9156e-03 5.8322e-03 1.4016e-02 4.4803e-03 1.1527e-03 3.2566e-04 6.2046e-03 5.1268e-03 2.3698e-03 2.3223e-04 1.0799e-04 3.4703e-03 -1.1895e-03 8.1811e-04 5.1070e-05 2.4902e-05 1.2464e-03 -9.7950e-04 6.2160e-04 4.2860e-05 3.9691e-05 8.5181e-04 3.8688e-03 5.6560e-04 8.1682e-04 9.0460e-05 2.4097e-05 8.8355e-04 3.1101e-04 2.7324e-05 2.0436e-06 8.5275e-07 4.7962e-05 6.3710e-04 5.5943e-05 6.0179e-01 1.0221e-01 4.2454e-03 7.3042e-04 1.4771e-01 10 0 0 10 0 0 99.96 23.05 0.43 0.00064 0.00301 181 50 1 5 0 255.720 26.94 20.01 23.05 26.77 7.9 997.47 900000 -280 -549 64 263 207 162 173 143 -134 -249 -235 -214 -179 -43 60 -344 294 -197 77 3 311 575 260 344 284 264 41 -33 143 -32 262 37 -214 -101 -9 -140 18 85 -61 87 20 -45 -66 -208 -98 105 -66 60 159 -50 -80 4 51 -29 36 26 -124 -111 116 22 -66 -11 18 44 -1 -14 -39 45 -176 169 102 112 27 -178 85 49 26 46 -164 4 -8 -18 -58 -120 -200 -45 23 -67 -71 188 -24 54 103 103 -20 27 -54 -25 -65 77 -27 64 110 175 82 33 -25 15 -32 -72 -39 -107 96 32 154 -21 -53 -107 -75 -8 -35 -160 -162 -25 -64 -80 -163 69 59 15 -42 44 75 -33 48 30 -90 34 102 -1 99 -2 -73 2 -35 900000 -70 -147 17 69 57 49 57 51 -50 -94 -91 -84 -72 -17 24 -142 126 -87 34 1 122 212 96 132 115 111 17 -13 59 -15 142 23 -135 -67 -6 -96 12 57 -44 61 13 -30 -43 -145 -71 79 -51 43 127 -40 -63 3 41 -22 29 23 -106 -90 93 17 -51 -10 15 40 -1 -12 -36 38 -135 120 73 86 23 -167 78 47 27 49 -187 5 -10 -21 -62 -118 -197 -42 22 -68 -72 206 -28 63 115 106 -21 30 -58 -29 -78 97 -35 86 154 246 110 42 -29 17 -37 -79 -45 -134 125 42 195 -26 -61 -129 -86 -9 -41 -181 -190 -30 -79 -101 -215 95 84 21 -63 64 107 -46 65 42 -132 54 171 -1 171 -3 -131 3 -60