File name: Pandora153s1_ChelseaMA_20240818_L2Fit_fsus1c1d20210519p1-8.txt File generation date: 20240819T045417.9Z Data description: Level 2 spectral fitting results file Data file version: fsus1c1p1-8 Local principal investigator: Jeff Geddes Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 153 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora153_OF_v2d20200209.txt Instrument calibration file used: Pandora153s1_CF_v1d20210519.txt Level 1 file used: Pandora153s1_ChelseaMA_20240818_L1_smca1c1d20210519p1-8.txt Full location name: Chelsea, Massachusetts Short location name: ChelseaMA Country of location: United States Location latitude [deg]: 42.3946 Location longitude [deg]: -71.0307 Location altitude [m]: 30 Local noon date: 20240818 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 238 383 Nominal wavelengths inside fitting window [nm]: 306.0362 306.1771 306.3179 306.4588 306.5997 306.7405 306.8813 307.0221 307.1629 307.3037 307.4445 307.5853 307.7261 307.8668 308.0075 308.1483 308.2890 308.4297 308.5704 308.7111 308.8517 308.9924 309.1331 309.2737 309.4143 309.5549 309.6955 309.8361 309.9767 310.1173 310.2578 310.3984 310.5389 310.6795 310.8200 310.9605 311.1010 311.2415 311.3819 311.5224 311.6628 311.8033 311.9437 312.0841 312.2245 312.3649 312.5053 312.6456 312.7860 312.9264 313.0667 313.2070 313.3473 313.4876 313.6279 313.7682 313.9085 314.0487 314.1890 314.3292 314.4694 314.6096 314.7498 314.8900 315.0302 315.1704 315.3105 315.4507 315.5908 315.7309 315.8710 316.0111 316.1512 316.2913 316.4314 316.5714 316.7115 316.8515 316.9915 317.1315 317.2715 317.4115 317.5515 317.6914 317.8314 317.9713 318.1112 318.2512 318.3911 318.5310 318.6708 318.8107 318.9506 319.0904 319.2303 319.3701 319.5099 319.6497 319.7895 319.9293 320.0690 320.2088 320.3485 320.4883 320.6280 320.7677 320.9074 321.0471 321.1868 321.3264 321.4661 321.6057 321.7454 321.8850 322.0246 322.1642 322.3038 322.4433 322.5829 322.7225 322.8620 323.0015 323.1410 323.2805 323.4200 323.5595 323.6990 323.8384 323.9779 324.1173 324.2567 324.3962 324.5356 324.6749 324.8143 324.9537 325.0930 325.2324 325.3717 325.5110 325.6503 325.7896 325.9289 326.0682 326.2075 326.3467 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20240818T161953.9Z 8996.680485 396 1 49.55 2 30.23 166.37 158.79 16.84 0.00 1 0.00 1 0 49 1.067e-02 5.649e-03 8.498e-03 4.789e-03 -5.668353e-06 1.867103e-06 1.541522e-07 3.641467e-07 5.070012e-06 231.57 -2.00 3.54 -2.00 321.28 0.00e+00 2.417023e-03 6.514885e-04 9.373896e-05 7.170221e-05 1.334744e-03 288.88 -2.00 20.00 -2.00 321.22 0.00e+00 9.261332e-04 8.997502e-04 5.168370e-05 2.443501e-05 2.265230e-03 288.88 -2.00 20.00 -2.00 321.29 0.00e+00 3.344492e-03 1.270862e-03 1.552550e-04 2.057732e-05 2.416880e-03 288.88 -2.00 20.00 -2.00 321.23 0.00e+00 1.541764e-01 6.141898e-03 2.509938e-04 2.759778e-03 1.323977e-02 204.31 9.39 0.00 3.32 23.19 316.87 0.00e+00 -6.284366e-04 3.163859e-04 2.426675e-05 3.310829e-05 3.532257e-04 288.88 -2.00 20.00 -2.00 315.71 0.00e+00 1.157 0.000 303.00 329.40 4 6.3594e+00 1.5438e-02 1.1417e-02 1.9912e-03 4.2422e-02 1.1596e-02 2.0140e-02 2.2307e-03 5.4317e-04 4.5082e-02 3.3262e-02 1.1877e-02 9.5828e-04 1.9290e-04 2.5295e-02 -2.2462e-02 4.6193e-03 5.6732e-04 3.2655e-05 9.1834e-03 5.4701e-03 3.4703e-03 2.9203e-04 4.3093e-05 6.0694e-03 2.8131e-04 -2.1248e-02 4.3617e-03 4.0517e-04 4.2014e-05 5.9820e-03 1.1377e-04 1.4689e-04 6.4884e-06 8.3966e-07 3.2398e-04 2.5188e-02 9.4142e-06 1.1333e+00 5.6168e-01 2.0640e-02 8.1519e-04 1.0570e+00 12 8 8 10 0 0 99.89 19.24 0.12 0.02519 0.02606 26 5 1 5 0 1905.560 22.29 15.01 19.24 29.35 0.0 986.64 448 -2557 2206 -2729 5032 2618 94 -1419 -2390 2117 -1561 1514 -3270 -20 -62 1088 -805 -1081 -1265 -1247 1167 -3 2573 -1101 2576 259 -183 2051 1038 1011 -822 -327 -780 355 1577 846 1494 582 373 -911 1353 -673 1247 -552 -252 -426 -718 272 -1470 -941 -1191 123 684 -128 -334 106 211 -1070 -172 -1397 785 -1628 21 -519 864 114 -510 327 -695 1598 -588 224 -205 492 -126 554 449 264 773 -62 143 206 213 -566 -163 239 504 -463 -834 655 -264 900 430 134 60 -162 -335 -1033 -376 -166 376 -23 80 649 -79 -120 352 -538 -783 774 -1083 32 -91 694 -109 -341 242 -286 -225 -326 163 -229 -54 177 -129 -231 152 -154 -216 828 -48 233 34 -273 156 295 -532 -152 213 125 356 265 -60 -463 -177 148 90 -578 499 -639 1104 633 26 -431 -785 681 -528 508 -1174 -7 -22 381 -301 -422 -508 -495 424 -1 824 -373 884 96 -70 729 368 390 -370 -172 -471 229 1036 570 999 389 247 -593 828 -407 731 -341 -164 -289 -507 195 -1084 -699 -882 89 488 -95 -264 89 183 -926 -135 -1022 545 -1218 18 -464 790 104 -452 268 -520 1059 -379 149 -152 402 -113 522 441 276 856 -72 170 244 240 -592 -154 206 460 -408 -805 683 -302 1063 498 146 60 -159 -342 -1151 -438 -201 470 -30 109 906 -110 -160 429 -608 -920 896 -1335 38 -116 892 -139 -423 313 -351 -262 -364 181 -271 -67 228 -170 -308 209 -204 -300 1164 -70 337 48 -376 228 427 -800 -219 331 207 625 487 -112 -875 -328 269 SS 20240818T184734.7Z 8996.783041 489 1 10.88 2 39.38 230.10 139.55 72.12 0.00 1 0.00 1 0 33 3.554e-03 2.550e-03 3.761e-03 2.598e-03 -8.541915e-07 1.029762e-06 2.633513e-08 3.640364e-07 1.690098e-06 231.56 -2.00 3.54 -2.00 320.57 0.00e+00 4.659297e-04 3.344401e-04 8.398269e-06 7.172440e-05 4.450710e-04 288.87 -2.00 20.00 -2.00 320.26 0.00e+00 1.127888e-04 4.842122e-04 9.847385e-06 2.472973e-05 7.526445e-04 288.87 -2.00 20.00 -2.00 320.77 0.00e+00 7.609796e-04 6.091906e-04 5.021966e-05 2.066995e-05 8.042350e-04 288.87 -2.00 20.00 -2.00 320.52 0.00e+00 1.728035e-01 3.318038e-03 8.329467e-05 2.759546e-03 4.425557e-03 229.32 4.80 0.00 2.95 7.72 315.94 0.00e+00 -1.015024e-04 1.425519e-04 8.690194e-06 3.310353e-05 1.176664e-04 288.87 -2.00 20.00 -2.00 314.85 0.00e+00 1.293 0.000 303.00 329.40 4 4.5852e+00 9.9504e-03 1.2542e-02 1.9801e-03 1.4144e-02 3.9381e-02 1.2126e-02 1.4089e-03 5.1534e-04 1.5050e-02 1.4916e-03 6.6258e-03 1.7603e-04 1.6519e-04 8.4404e-03 -9.0122e-04 2.4022e-03 7.1798e-05 2.6353e-05 3.0804e-03 3.9489e-04 1.7725e-03 3.2212e-05 4.2123e-05 2.0181e-03 1.4225e-03 -3.2292e-03 2.0202e-03 4.7738e-05 3.5690e-05 1.8232e-03 4.5610e-05 7.5338e-05 1.4207e-06 7.9824e-07 1.0791e-04 2.6400e-02 2.5726e-06 3.0037e-01 2.8152e-01 8.0988e-04 9.4678e-04 3.3842e-01 12 9 9 12 1 1 99.96 19.10 0.27 0.02640 0.02675 6 6 1 5 0 1553.670 22.19 15.00 19.10 26.59 0.0 973.14 875 -562 68 -600 -134 297 -926 430 -415 513 -741 518 4 -272 246 483 -776 -307 402 -515 1122 545 254 -581 106 506 -74 546 -347 612 234 -594 -608 320 -35 -462 727 262 445 95 -505 -529 338 305 -525 528 -658 -96 254 -6 -109 -454 542 521 -80 -278 -68 -536 119 147 -47 -488 -421 101 167 65 -68 263 81 117 -34 208 -18 -208 252 -99 307 -208 349 -154 233 -28 -193 261 -435 99 -29 -355 -48 34 278 190 -165 76 -400 296 -99 -174 243 65 -289 88 121 150 -17 144 196 -194 -183 417 -279 118 -77 -120 164 -74 65 41 -331 -244 21 -60 214 -8 -15 -86 -132 8 -114 294 4 124 -14 -197 -157 138 -7 -281 215 182 -137 264 -105 -88 62 -51 237 -170 21 -186 -42 100 -322 163 -170 213 -318 225 2 -123 110 218 -370 -152 203 -259 519 234 106 -251 48 243 -37 253 -160 305 135 -376 -411 231 -27 -355 551 198 332 69 -355 -360 244 212 -389 405 -531 -79 210 -5 -91 -375 442 438 -68 -251 -64 -498 100 122 -38 -420 -380 99 158 65 -65 235 70 91 -27 160 -16 -187 248 -97 313 -227 380 -177 272 -33 -215 283 -459 94 -27 -347 -51 37 313 224 -190 87 -427 301 -106 -203 280 78 -363 114 156 200 -22 180 240 -232 -206 468 -331 141 -98 -157 210 -93 78 48 -375 -264 22 -69 259 -10 -19 -106 -168 11 -153 401 6 174 -20 -261 -214 185 -9 -393 306 278 -212 427 -174 -147 101 -81 SS 20240818T191936.8Z 8996.805287 507 1 6.12 2 44.22 239.32 134.05 78.68 0.00 1 0.00 1 0 49 4.097e-03 2.739e-03 3.542e-03 2.465e-03 -6.738033e-08 9.749323e-07 4.393659e-08 3.640383e-07 1.948143e-06 231.56 -2.00 3.54 -2.00 320.59 0.00e+00 6.745735e-04 3.187338e-04 1.767277e-05 7.171494e-05 5.131028e-04 288.87 -2.00 20.00 -2.00 320.23 0.00e+00 1.502289e-04 4.565326e-04 1.932906e-05 2.480012e-05 8.658302e-04 288.87 -2.00 20.00 -2.00 320.78 0.00e+00 1.369699e-03 5.821977e-04 5.914048e-05 2.060059e-05 9.272320e-04 288.87 -2.00 20.00 -2.00 320.52 0.00e+00 1.817908e-01 3.145740e-03 8.413149e-05 2.759622e-03 5.122540e-03 225.51 4.26 0.00 2.83 8.91 315.92 0.00e+00 3.908911e-05 1.359924e-04 2.689957e-05 3.310393e-05 1.357474e-04 288.87 -2.00 20.00 -2.00 314.85 0.00e+00 1.393 0.000 303.00 329.40 4 3.8582e+00 9.0558e-03 1.3538e-02 1.9785e-03 1.6312e-02 1.6366e-02 1.1246e-02 1.5833e-03 5.1747e-04 1.7406e-02 7.3287e-03 6.2341e-03 2.9063e-04 1.6538e-04 9.7540e-03 -1.3921e-04 2.3229e-03 5.1571e-05 2.7048e-05 3.6080e-03 -1.5620e-03 1.6694e-03 6.5087e-05 4.2690e-05 2.3274e-03 2.6182e-03 5.4423e-04 1.8016e-03 6.3294e-05 3.1188e-05 1.9125e-03 3.0562e-04 7.1689e-05 1.8887e-06 7.8971e-07 1.2436e-04 2.5268e-02 2.6071e-05 4.7657e-01 2.5774e-01 3.3055e-03 1.0757e-03 3.8009e-01 12 9 9 12 1 1 98.33 19.11 0.26 0.02527 0.02760 5 9 1 5 0 1018.700 22.19 15.00 19.11 27.29 0.0 975.78 443 -1780 145 -1106 776 -695 -23 741 -773 398 -434 108 -744 -100 1051 842 739 -240 320 -642 867 -441 331 -671 524 -609 215 708 -104 391 103 341 220 200 -239 63 145 365 -181 6 717 -938 361 -504 297 -261 -213 -330 152 -94 -585 636 -88 -28 -727 4 58 54 230 -599 -3 210 -209 -106 -31 -134 -119 -16 -244 496 -375 337 -187 300 154 -230 237 -150 469 -12 -110 -22 -57 398 27 179 -236 442 -466 450 -242 48 351 44 -29 -471 -54 82 101 -159 86 214 -153 -44 178 -54 -65 -179 -104 210 -168 343 -455 182 -135 174 -157 -244 84 245 229 -401 225 66 -314 153 -58 -49 -42 311 -293 168 -142 39 51 -202 264 103 -218 -102 72 -70 40 54 -34 89 122 -550 46 -350 243 -242 -8 291 -332 174 -181 46 -327 -44 456 371 341 -117 159 -319 397 -204 147 -311 254 -295 106 329 -48 197 56 219 152 141 -175 47 109 270 -134 4 521 -672 254 -371 217 -201 -170 -271 125 -74 -464 518 -72 -22 -625 4 53 49 198 -508 -2 172 -193 -101 -30 -131 -112 -14 -203 392 -302 265 -157 279 149 -237 241 -163 516 -13 -125 -26 -64 431 28 169 -230 426 -473 498 -281 56 414 49 -31 -490 -59 93 119 -188 105 273 -197 -58 235 -68 -79 -209 -120 242 -195 425 -578 235 -172 215 -193 -284 97 270 255 -478 268 82 -383 188 -74 -64 -56 431 -399 238 -197 53 67 -272 350 147 -321 -154 112 -113 64 86 -56 144 SS 20240818T192856.6Z 8996.811766 514 1 18.45 2 45.72 241.74 132.42 80.44 0.00 1 0.00 1 0 49 3.487e-03 2.222e-03 3.538e-03 2.182e-03 -3.911777e-07 8.547018e-07 3.581897e-08 3.640767e-07 1.655235e-06 231.56 -2.00 3.54 -2.00 320.85 0.00e+00 7.376119e-04 2.847018e-04 3.829065e-06 7.170123e-05 4.350385e-04 288.87 -2.00 20.00 -2.00 320.56 0.00e+00 -4.197171e-04 4.046893e-04 1.891389e-05 2.463172e-05 7.363614e-04 288.87 -2.00 20.00 -2.00 320.98 0.00e+00 1.394105e-03 5.256708e-04 7.534203e-05 2.055164e-05 7.890690e-04 288.87 -2.00 20.00 -2.00 320.79 0.00e+00 1.900468e-01 2.861774e-03 1.058075e-04 2.759783e-03 4.357037e-03 229.84 3.74 0.00 2.69 7.58 316.43 0.00e+00 -4.856456e-05 1.314914e-04 1.017210e-05 3.310305e-05 1.155932e-04 288.87 -2.00 20.00 -2.00 315.31 0.00e+00 1.430 0.000 303.00 329.40 4 4.5880e+00 8.3786e-03 1.3896e-02 1.9832e-03 1.3842e-02 2.3882e-02 1.0525e-02 1.6115e-03 5.3034e-04 1.4795e-02 8.2679e-03 5.7364e-03 2.3633e-04 1.7942e-04 8.2661e-03 -7.2854e-03 2.1611e-03 5.7045e-05 3.0293e-05 3.0806e-03 1.3504e-03 1.5451e-03 3.9953e-05 4.3495e-05 1.9833e-03 1.2054e-03 -7.9543e-03 1.6209e-03 6.8625e-05 3.3795e-05 1.5782e-03 2.1700e-04 6.3414e-05 1.9521e-06 8.0655e-07 1.0588e-04 2.6000e-02 -4.0897e-06 -7.3447e-02 2.2866e-01 5.2516e-04 9.0530e-04 3.1839e-01 12 9 9 12 1 1 99.10 19.13 0.26 0.02600 0.02766 8 5 1 5 0 2048.910 22.19 15.01 19.13 27.38 0.0 976.58 763 133 -1188 -768 100 392 927 109 -394 -497 -303 -9 -623 -185 -495 -936 218 -147 358 -413 1252 -533 1084 -197 582 175 452 350 604 -171 87 290 324 -29 174 360 39 9 72 -249 140 -519 805 210 77 -274 110 394 -184 129 -530 -560 51 150 -320 -217 -325 18 -63 132 7 -197 -381 -190 84 -117 -26 -352 -346 23 -383 520 -22 456 156 49 -117 174 -110 156 349 181 -128 158 -86 42 33 -445 -328 227 -48 31 65 259 1 -45 9 61 115 -103 -32 186 235 222 -166 36 -256 165 155 -118 -109 -6 -238 29 274 -89 92 -377 32 60 77 -215 179 -334 39 -168 -81 -290 122 156 -124 398 -77 -47 9 148 -34 -33 -60 -99 121 -72 -43 120 99 -84 161 31 -294 -187 24 104 274 36 -141 -183 -114 -4 -248 -74 -198 -381 92 -65 162 -187 521 -209 407 -78 241 78 206 151 256 -80 43 169 200 -20 121 254 28 6 50 -169 91 -332 506 139 54 -201 84 307 -147 104 -427 -443 40 121 -258 -187 -294 16 -51 107 6 -166 -335 -180 83 -115 -24 -308 -293 18 -281 396 -19 404 152 47 -118 186 -126 175 400 206 -149 169 -90 40 31 -436 -330 250 -54 37 75 297 1 -47 10 71 132 -123 -40 242 302 296 -222 49 -319 200 177 -136 -132 -7 -309 39 356 -113 111 -458 37 66 85 -253 224 -409 49 -213 -107 -406 167 218 -178 570 -108 -64 12 205 -45 -47 -88 -155 192 -120 -72 204 166 -140 SS 20240818T202729.2Z 8996.852421 554 1 50.16 2 55.77 254.90 122.05 90.37 0.00 1 0.00 1 0 49 4.053e-03 1.624e-03 4.282e-03 1.730e-03 -3.167952e-08 6.593608e-07 4.645154e-08 3.642241e-07 1.921323e-06 231.55 -2.00 3.54 -2.00 321.78 0.00e+00 7.066901e-04 2.401921e-04 2.790687e-05 7.168908e-05 4.997243e-04 288.86 -2.00 20.00 -2.00 321.78 0.00e+00 2.891807e-04 3.186858e-04 1.702555e-05 2.443146e-05 8.548605e-04 288.86 -2.00 20.00 -2.00 321.65 0.00e+00 1.175105e-03 4.846027e-04 9.111313e-05 2.040261e-05 9.166391e-04 288.86 -2.00 20.00 -2.00 321.69 0.00e+00 2.343276e-01 2.549998e-03 1.872485e-04 2.759970e-03 5.110537e-03 227.71 2.63 0.00 2.17 8.84 318.04 0.00e+00 -2.417281e-04 1.477090e-04 8.654726e-06 3.312320e-05 1.350438e-04 288.86 -2.00 20.00 -2.00 316.81 0.00e+00 1.772 0.000 303.00 329.40 4 4.4166e+00 6.5864e-03 1.7202e-02 1.9957e-03 1.6119e-02 2.9106e-02 9.4586e-03 2.0794e-03 5.7453e-04 1.7278e-02 6.7664e-03 5.0770e-03 3.9529e-04 2.1917e-04 9.5624e-03 -6.4695e-03 2.1333e-03 2.2684e-04 4.8244e-05 3.7121e-03 1.9675e-03 1.4033e-03 7.0032e-05 5.1477e-05 2.3775e-03 9.6081e-04 -6.8470e-03 1.3485e-03 1.1061e-04 3.1111e-05 1.3632e-03 1.8512e-04 5.2176e-05 2.4262e-06 8.3255e-07 1.2308e-04 2.5009e-02 1.9170e-05 1.3840e-01 1.7101e-01 3.2502e-03 6.6937e-04 3.3551e-01 12 8 8 10 0 0 99.96 19.21 0.33 0.02501 0.02642 28 5 1 5 0 1791.170 22.29 15.00 19.21 27.07 0.0 974.78 854 -823 1208 231 473 1859 -986 -19 -1297 433 -1383 906 -225 -565 12 958 -776 121 401 213 -37 -120 1469 -429 -4 451 -35 -202 -763 -860 170 355 -8 69 -161 -51 30 -378 -6 61 309 -262 299 -55 -14 164 12 156 -28 401 7 -165 -449 -48 424 113 12 -175 138 -275 131 177 -41 -500 76 -186 -69 43 -177 467 -13 258 -41 124 22 -340 -107 224 43 -158 178 3 0 163 67 34 -342 -294 -131 178 51 -72 239 274 40 92 -213 -242 -89 -151 -43 188 78 218 -57 -102 -129 -16 -26 21 8 -81 -42 -4 62 274 6 -80 -136 -151 30 -54 -120 107 9 29 43 121 -275 178 18 67 20 -127 -111 8 51 -5 -26 112 75 -17 0 -28 -7 -34 100 -108 164 31 66 282 -174 -4 -279 95 -318 211 -54 -140 3 236 -205 33 114 60 -10 -30 353 -110 -1 132 -11 -59 -220 -271 61 152 -4 34 -82 -27 16 -197 -3 31 167 -139 158 -31 -8 93 7 95 -17 252 4 -102 -277 -30 286 82 9 -134 97 -181 84 121 -32 -422 66 -161 -58 33 -123 322 -9 180 -29 100 20 -322 -106 235 44 -170 195 3 -1 170 64 30 -294 -269 -132 197 57 -84 273 319 43 95 -230 -285 -102 -178 -53 243 107 310 -82 -139 -162 -20 -31 25 10 -100 -55 -5 82 347 7 -100 -163 -173 35 -67 -158 134 12 39 59 175 -420 276 28 106 32 -189 -161 12 75 -9 -40 189 135 -31 1 -56 -14 -66 SS 20240818T210222.6Z 8996.876651 573 1 3.27 2 62.08 261.57 115.84 95.75 0.00 1 0.00 1 0 49 2.947e-03 1.509e-03 3.138e-03 1.483e-03 2.047556e-06 5.676934e-07 5.974480e-08 3.641373e-07 1.387120e-06 231.55 -2.00 3.54 -2.00 321.38 0.00e+00 5.080465e-04 1.988639e-04 2.753792e-05 7.167957e-05 3.577717e-04 288.86 -2.00 20.00 -2.00 321.17 0.00e+00 -3.244586e-04 2.687287e-04 9.424894e-06 2.472686e-05 6.251147e-04 288.86 -2.00 20.00 -2.00 321.35 0.00e+00 5.339380e-04 3.841969e-04 6.697668e-05 2.017692e-05 6.660962e-04 288.86 -2.00 20.00 -2.00 321.28 0.00e+00 2.803138e-01 2.117017e-03 1.575744e-04 2.759971e-03 3.740528e-03 234.44 1.86 0.00 1.82 6.45 317.42 0.00e+00 2.667620e-04 1.105668e-04 2.301564e-05 3.311333e-05 9.910045e-05 288.86 -2.00 20.00 -2.00 316.23 0.00e+00 2.125 0.000 303.00 329.40 4 1.5420e+00 6.0192e-03 2.0605e-02 1.9839e-03 1.1720e-02 2.4553e-02 8.0193e-03 2.3703e-03 5.5747e-04 1.2582e-02 -1.1513e-03 4.2228e-03 2.9129e-04 1.9846e-04 6.8932e-03 -3.0331e-03 1.8698e-03 2.4629e-04 4.1160e-05 2.7535e-03 1.5796e-03 1.2182e-03 9.3086e-05 5.1109e-05 1.8317e-03 1.1448e-02 -6.1467e-03 7.5928e-04 5.0935e-05 1.7310e-05 6.6633e-04 7.3765e-05 4.3090e-05 2.4845e-06 8.0833e-07 8.9588e-05 2.4506e-02 -7.0533e-06 -3.7468e-01 1.2675e-01 2.4492e-03 1.3842e-03 2.1981e-01 12 9 1 12 1 1 98.66 19.28 0.27 0.02451 0.02507 18 56 1 5 0 171.670 22.29 15.00 19.28 28.94 0.0 984.54 1384 656 831 1085 191 684 -730 -657 -247 220 -552 -842 -101 -181 -281 247 8 -301 -113 -135 242 -289 -488 450 -152 589 13 216 -409 -459 -215 -62 256 -60 -143 277 287 325 68 -7 168 5 305 -227 194 248 120 -98 -523 366 -14 2 11 -116 -38 -165 218 -150 300 128 127 46 -104 90 -196 -57 -131 113 -266 -514 -193 -16 -186 -202 227 -174 -26 -77 48 -135 27 1 80 50 -137 110 104 32 -29 155 11 146 22 68 135 162 125 -302 187 96 2 -88 -38 -13 55 -102 -88 27 -107 178 82 1 -36 -53 -150 29 175 166 -278 143 62 150 -155 -86 -265 -41 5 43 57 -45 35 80 15 -107 79 -8 49 -112 -205 -37 267 132 30 -57 -110 27 204 98 131 171 31 125 -155 -158 -60 56 -147 -233 -29 -53 -81 73 3 -100 -39 -46 78 -88 -147 143 -53 205 5 81 -151 -173 -94 -30 135 -35 -81 160 167 189 40 -4 100 3 181 -135 123 166 80 -68 -369 261 -10 1 8 -84 -27 -131 174 -120 234 94 97 36 -86 77 -175 -51 -117 93 -209 -389 -141 -12 -155 -180 213 -167 -26 -78 52 -148 30 1 88 51 -134 104 96 32 -30 173 13 175 26 78 148 169 137 -345 224 116 2 -112 -50 -18 76 -135 -112 33 -129 215 100 1 -48 -69 -199 37 224 201 -335 164 73 181 -201 -113 -359 -54 7 61 85 -66 53 121 22 -155 111 -11 70 -167 -320 -60 448 228 54 -103 -196 48 SS 20240818T210638.5Z 8996.879612 576 1 8.03 2 62.86 262.35 115.09 96.39 0.00 1 0.00 1 0 49 3.400e-03 1.818e-03 4.883e-03 1.930e-03 3.015099e-06 7.314558e-07 5.472416e-08 3.642013e-07 1.599509e-06 231.55 -2.00 3.54 -2.00 321.64 0.00e+00 2.779597e-04 2.630699e-04 2.195412e-05 7.167787e-05 4.123882e-04 288.86 -2.00 20.00 -2.00 321.48 0.00e+00 -7.066394e-04 3.505601e-04 7.350169e-06 2.459941e-05 7.211916e-04 288.86 -2.00 20.00 -2.00 321.54 0.00e+00 1.995517e-04 5.265686e-04 5.975350e-05 2.025094e-05 7.682958e-04 288.86 -2.00 20.00 -2.00 321.54 0.00e+00 2.873827e-01 2.850953e-03 1.677827e-04 2.760092e-03 4.318209e-03 232.54 2.42 0.00 1.77 7.43 317.93 0.00e+00 1.796850e-04 1.639005e-04 2.308310e-05 3.312491e-05 1.144476e-04 288.86 -2.00 20.00 -2.00 316.72 0.00e+00 2.180 0.000 303.00 329.40 4 2.8016e+00 7.7404e-03 2.1140e-02 1.9898e-03 1.3523e-02 3.1876e-02 1.0789e-02 2.3929e-03 5.7176e-04 1.4510e-02 -2.7677e-03 5.6893e-03 2.9615e-04 2.1446e-04 7.9501e-03 -4.9577e-03 2.6454e-03 2.0639e-04 5.1123e-05 3.2102e-03 3.1966e-03 1.6741e-03 6.4300e-05 5.4428e-05 2.1341e-03 3.0664e-03 -5.4779e-03 1.0871e-03 5.1912e-05 2.0638e-05 7.5480e-04 -3.4322e-06 5.6626e-05 2.1888e-06 8.1338e-07 1.0334e-04 2.4571e-02 -6.6163e-06 -3.1406e-01 1.6528e-01 7.0043e-04 1.0076e-03 2.5165e-01 12 9 9 12 1 1 99.82 19.31 0.26 0.02457 0.02454 15 19 1 5 0 501.380 22.40 15.01 19.31 29.32 0.0 986.27 -1326 -452 -503 582 -356 91 -818 -576 768 -451 1123 -783 -121 826 942 24 318 -658 130 461 142 567 -46 533 107 447 -318 -100 -140 -1056 41 -153 -325 -34 35 -184 -215 522 -195 -18 -167 -420 591 49 -180 11 269 411 -369 -163 224 297 241 25 99 391 -173 208 -148 -162 -504 -73 -17 45 -160 163 -114 -337 -18 106 230 -258 334 81 -68 21 -2 -47 -189 106 -43 39 1 185 132 -77 430 -191 121 -273 -43 101 214 -171 -98 1 -73 61 -271 102 90 134 -138 -87 -176 126 31 -118 -2 97 466 -70 -259 79 -208 211 188 -25 -98 160 83 -174 135 40 -122 -79 2 9 185 -56 153 -113 190 -273 -307 152 11 -156 54 32 -40 -45 213 -96 18 10 -147 -55 -65 74 -48 14 -141 -113 150 -94 239 -176 -28 193 219 6 81 -178 36 128 38 140 -11 139 31 138 -103 -31 -43 -357 16 -66 -162 -17 19 -99 -117 282 -106 -10 -88 -218 307 27 -107 7 166 261 -241 -108 148 192 155 17 71 283 -134 161 -113 -117 -361 -56 -14 40 -138 138 -98 -270 -14 74 156 -187 256 70 -62 20 -2 -48 -205 114 -48 43 2 188 129 -70 384 -184 122 -307 -51 118 258 -194 -108 1 -80 68 -322 126 111 174 -182 -120 -246 168 40 -149 -3 117 586 -90 -353 103 -281 275 235 -31 -117 182 97 -218 171 54 -169 -107 3 13 275 -85 237 -177 286 -398 -452 219 16 -240 86 52 -71 -80 392 -173 33 18