File name: Pandora213s1_ChiangMai_20221214_L2Fit_fout2c2d20220805p1-8.txt File generation date: 20260203T162901.3Z Data description: Level 2 spectral fitting results file Data file version: fout2c2p1-8 Local principal investigator: Surassawadee Phoompanit Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 213 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora213_OF_v4d20210930.txt Instrument calibration file used: Pandora213s1_CF_v2d20220805.txt Level 1 file used: Pandora213s1_ChiangMai_20221214_L1_smca1c2d20220805p1-8.txt.bz2 Full location name: Chiang Mai Rajabhat University (Chiang Mai) Short location name: ChiangMai Country of location: Thailand Location latitude [deg]: 18.8063 Location longitude [deg]: 98.9860 Location altitude [m]: 60 Local noon date: 20221214 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB data based on session102 First and last pixel inside fitting window: 196 337 Nominal wavelengths inside fitting window [nm]: 305.0486 305.1900 305.3314 305.4728 305.6141 305.7555 305.8968 306.0382 306.1795 306.3208 306.4621 306.6034 306.7447 306.8860 307.0273 307.1685 307.3098 307.4510 307.5922 307.7334 307.8746 308.0158 308.1570 308.2981 308.4393 308.5804 308.7216 308.8627 309.0038 309.1449 309.2860 309.4270 309.5681 309.7092 309.8502 309.9912 310.1322 310.2733 310.4143 310.5552 310.6962 310.8372 310.9781 311.1191 311.2600 311.4009 311.5418 311.6827 311.8236 311.9645 312.1053 312.2462 312.3870 312.5278 312.6687 312.8095 312.9503 313.0910 313.2318 313.3726 313.5133 313.6541 313.7948 313.9355 314.0762 314.2169 314.3576 314.4982 314.6389 314.7796 314.9202 315.0608 315.2014 315.3420 315.4826 315.6232 315.7638 315.9043 316.0449 316.1854 316.3259 316.4664 316.6069 316.7474 316.8879 317.0284 317.1688 317.3093 317.4497 317.5901 317.7305 317.8709 318.0113 318.1517 318.2921 318.4324 318.5727 318.7131 318.8534 318.9937 319.1340 319.2743 319.4146 319.5548 319.6951 319.8353 319.9755 320.1157 320.2559 320.3961 320.5363 320.6765 320.8166 320.9568 321.0969 321.2371 321.3772 321.5173 321.6574 321.7974 321.9375 322.0776 322.2176 322.3576 322.4977 322.6377 322.7777 322.9176 323.0576 323.1976 323.3375 323.4775 323.6174 323.7573 323.8972 324.0371 324.1770 324.3169 324.4567 324.5966 324.7364 324.8763 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Columns 100-241: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 242-383: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------