File name: Pandora76s1_Dhaka_20231128_L2Fit_fwvt1c7d20230312p1-8.txt File generation date: 20250226T084027.9Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c7p1-8 Local principal investigator: Abdus Salam Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 76 Spectrometer number: 1 Processing software version used: BlickP v1.8.74 Instrument operation file used: Pandora76_OF_v2d20220127.txt Instrument calibration file used: Pandora76s1_CF_v7d20230312.txt Level 1 file used: Pandora76s1_Dhaka_20231128_L1_smca1c7d20230312p1-8.txt Full location name: University of Dhaka; Mukarram Hussain Khundker Biggyan Bhaban (MHK Bhaban) Short location name: Dhaka Country of location: Bangladesh Location latitude [deg]: 23.7284 Location longitude [deg]: 90.3982 Location altitude [m]: 34 Local noon date: 20231128 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1614 1763 Nominal wavelengths inside fitting window [nm]: 492.0694 492.1909 492.3123 492.4337 492.5551 492.6765 492.7979 492.9193 493.0406 493.1619 493.2832 493.4045 493.5258 493.6470 493.7682 493.8895 494.0107 494.1318 494.2530 494.3742 494.4953 494.6164 494.7375 494.8586 494.9796 495.1007 495.2217 495.3427 495.4637 495.5847 495.7057 495.8266 495.9475 496.0684 496.1893 496.3102 496.4311 496.5519 496.6727 496.7935 496.9143 497.0351 497.1559 497.2766 497.3973 497.5180 497.6387 497.7594 497.8801 498.0007 498.1213 498.2419 498.3625 498.4831 498.6036 498.7242 498.8447 498.9652 499.0857 499.2061 499.3266 499.4470 499.5674 499.6878 499.8082 499.9286 500.0489 500.1693 500.2896 500.4099 500.5302 500.6504 500.7707 500.8909 501.0111 501.1313 501.2515 501.3716 501.4918 501.6119 501.7320 501.8521 501.9722 502.0922 502.2123 502.3323 502.4523 502.5723 502.6923 502.8122 502.9321 503.0521 503.1720 503.2919 503.4117 503.5316 503.6514 503.7712 503.8910 504.0108 504.1306 504.2503 504.3701 504.4898 504.6095 504.7291 504.8488 504.9684 505.0881 505.2077 505.3273 505.4469 505.5664 505.6860 505.8055 505.9250 506.0445 506.1640 506.2834 506.4029 506.5223 506.6417 506.7611 506.8804 506.9998 507.1191 507.2384 507.3577 507.4770 507.5963 507.7155 507.8348 507.9540 508.0732 508.1924 508.3115 508.4307 508.5498 508.6689 508.7880 508.9071 509.0262 509.1452 509.2642 509.3832 509.5022 509.6212 509.7402 509.8591 509.9780 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-250: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 251-400: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20231128T011453.6Z 8732.052009 268 1 10.63 2 79.83 118.73 92.02 299.53 0.00 1 0.00 1 0 22 3.828e-03 3.805e-03 3.203e-04 3.200e-04 7.582248e+03 2.193727e+01 4.915286e+02 -6.000000e+00 2.239819e+02 291.00 -2.00 20.00 -2.00 505.34 0.00e+00 2.987720e-03 9.121140e-06 1.700330e-04 -6.000000e+00 1.106340e-04 291.00 -2.00 20.00 -2.00 500.72 0.00e+00 3.257649e-01 6.267633e-03 5.713715e-02 -6.000000e+00 7.575035e-02 225.27 -2.00 3.14 -2.00 502.28 0.00e+00 5.424 0.001 489.00 513.00 1 2.8485e+00 4.8278e-04 9.9457e-03 -6.0000e+00 5.8410e-03 -2.7882e-02 1.2105e-04 1.3037e-03 -6.0000e+00 1.4911e-03 4.8566e-02 4.3514e-05 3.3194e-05 7.7802e-05 -6.0000e+00 4.1453e-04 5.0192e-03 1.0155e-05 12 9 1 12 1 1 86.28 23.82 1.57 0.00502 0.00532 76 64 1 4 0 138.040 26.21 20.00 23.82 30.47 9.9 999.60 -704 -526 -283 -55 91 570 605 465 389 255 237 -33 -309 -325 -349 -422 -181 171 98 -44 193 244 307 461 514 504 439 125 -407 -425 -365 -510 -113 373 29 -144 111 150 -75 -50 90 137 211 352 396 386 387 293 68 -347 -587 -727 -772 -505 -133 -96 -116 26 107 254 414 515 398 374 173 172 66 -54 -369 -374 -240 -266 -193 28 -123 -445 -406 -442 -540 -617 -567 -675 -534 -227 -249 -331 -305 -246 -123 -57 149 529 426 314 381 269 -30 -292 -617 -838 -824 -640 -154 -128 -388 -289 -281 -256 -56 99 -9 205 380 473 726 884 875 683 408 390 195 225 561 358 168 294 241 161 428 279 -123 -54 -181 -463 -106 61 -219 -130 195 173 148 264 304 205 166 -117 -472 -595 -613 -606 -660 -500 -272 -53 91 576 608 471 394 255 239 -33 -304 -317 -339 -413 -180 170 100 -45 195 246 310 467 523 513 445 125 -407 -424 -360 -506 -112 373 30 -149 114 152 -75 -50 90 139 217 359 407 398 396 297 69 -344 -582 -708 -750 -496 -132 -97 -118 27 110 260 423 530 411 385 177 173 66 -54 -367 -368 -236 -262 -192 28 -121 -446 -400 -429 -521 -595 -549 -659 -525 -225 -244 -326 -301 -242 -121 -57 148 532 431 316 377 265 -28 -280 -583 -786 -780 -608 -151 -127 -385 -288 -277 -255 -56 98 -9 209 382 479 739 905 902 706 419 394 198 227 563 362 167 293 241 161 426 281 -123 -53 -177 -454 -104 61 -220 -132 197 177 153 273 315 213 171 -120 -475 -600 -614 -611 SQ 20231128T011909.2Z 8732.054967 271 1 10.56 2 78.98 119.24 92.83 299.96 0.00 1 0.00 1 0 15 3.590e-03 3.565e-03 3.675e-04 3.672e-04 7.180280e+03 2.502470e+01 4.686526e+02 -6.000000e+00 2.100498e+02 291.00 -2.00 20.00 -2.00 505.33 0.00e+00 2.714243e-03 1.045465e-05 1.556458e-04 -6.000000e+00 1.037505e-04 291.00 -2.00 20.00 -2.00 500.70 0.00e+00 2.900737e-01 7.193832e-03 5.344965e-02 -6.000000e+00 7.102510e-02 225.27 -2.00 3.14 -2.00 502.25 0.00e+00 5.041 0.001 489.00 513.00 1 3.1738e+00 5.5395e-04 9.2370e-03 -6.0000e+00 5.4768e-03 -2.4533e-02 1.3930e-04 1.2259e-03 -6.0000e+00 1.3978e-03 3.7310e-02 -2.9724e-04 3.8119e-05 7.2746e-05 -6.0000e+00 3.8869e-04 3.9680e-03 3.0799e-05 12 1 1 12 1 1 97.24 23.85 1.43 0.00397 0.00191 57 48 1 4 0 182.030 26.32 20.00 23.85 30.70 9.9 1001.06 -656 -484 -160 -97 47 517 573 414 383 327 195 -19 -279 -233 -328 -364 -92 97 87 -64 152 215 209 408 508 421 389 98 -414 -372 -317 -368 -122 319 -7 -106 156 142 -74 -8 45 69 234 348 476 418 311 254 13 -296 -548 -637 -744 -489 -128 -157 -110 -7 77 232 360 413 349 322 250 119 -21 -52 -343 -386 -220 -315 -140 84 -113 -398 -378 -408 -446 -478 -480 -575 -490 -209 -267 -310 -337 -196 -170 -48 179 455 453 278 410 337 -118 -282 -553 -839 -840 -621 -124 -127 -301 -268 -345 -276 -59 115 -22 122 347 544 536 855 897 608 464 361 144 170 571 294 204 345 303 185 457 286 -112 -93 -241 -441 -86 95 -184 -104 190 128 175 257 214 237 107 -104 -443 -552 -595 -570 -614 -460 -153 -96 47 522 576 420 388 334 196 -19 -274 -231 -325 -355 -91 98 88 -65 155 221 215 412 516 428 393 100 -413 -369 -311 -364 -120 325 -7 -109 159 143 -74 -9 46 69 239 360 486 428 316 260 13 -298 -539 -628 -733 -477 -128 -158 -113 -7 78 235 366 421 357 329 253 121 -21 -51 -337 -384 -218 -314 -138 84 -113 -394 -368 -401 -435 -465 -470 -556 -478 -205 -265 -309 -337 -195 -169 -47 177 453 454 277 410 329 -115 -268 -519 -798 -788 -596 -121 -125 -302 -270 -344 -273 -59 115 -22 123 352 555 551 866 914 621 471 368 145 169 566 294 205 347 304 186 457 285 -111 -92 -237 -434 -85 94 -186 -104 193 131 181 262 219 243 110 -107 -448 -548 -587 -566 SQ 20231128T012441.6Z 8732.058815 274 1 11.62 2 77.88 119.93 93.87 300.53 0.00 1 0.00 1 0 15 3.496e-03 3.472e-03 1.447e-04 1.446e-04 6.607809e+03 9.809919e+00 4.303370e+02 -6.000000e+00 2.045363e+02 291.00 -2.00 20.00 -2.00 505.34 0.00e+00 2.893005e-03 4.119423e-06 1.647677e-04 -6.000000e+00 1.010274e-04 291.00 -2.00 20.00 -2.00 500.70 0.00e+00 2.494048e-01 2.832680e-03 5.146226e-02 -6.000000e+00 6.915870e-02 225.27 -2.00 3.14 -2.00 502.25 0.00e+00 4.618 0.001 489.00 513.00 1 1.3701e+00 2.1822e-04 8.7778e-03 -6.0000e+00 5.3329e-03 -2.5063e-02 5.4808e-05 1.1476e-03 -6.0000e+00 1.3610e-03 2.4095e-01 -2.0757e-04 1.5049e-05 7.3247e-05 -6.0000e+00 3.7848e-04 6.7742e-03 1.6144e-05 10 0 0 10 0 0 90.72 23.87 1.40 0.00677 0.00533 513 88 1 4 0 22.590 26.32 20.01 23.87 31.07 10.0 1003.13 -653 -471 -210 -87 61 510 584 457 380 271 201 -51 -295 -252 -292 -381 -173 146 58 -46 146 234 241 470 520 419 400 110 -397 -366 -288 -435 -60 378 -43 -135 79 74 -82 -26 56 86 218 335 380 379 324 253 -2 -340 -552 -644 -764 -443 -161 -150 -97 -23 101 210 406 394 341 375 230 144 46 -38 -289 -390 -223 -284 -172 21 -141 -421 -372 -331 -434 -496 -475 -571 -509 -200 -198 -353 -255 -184 -127 -73 142 442 342 266 331 241 -67 -234 -530 -764 -807 -572 -112 -135 -374 -300 -309 -256 -36 76 7 179 321 443 592 803 870 600 439 399 200 265 518 331 160 331 269 200 436 223 -119 -70 -206 -456 -120 69 -193 -102 162 113 119 231 208 226 152 -94 -424 -535 -533 -505 -607 -445 -204 -85 61 516 601 474 393 277 203 -51 -290 -245 -283 -373 -172 147 58 -47 148 238 245 479 533 429 407 111 -392 -363 -282 -430 -61 379 -44 -140 81 75 -83 -26 57 88 225 350 388 387 329 261 -3 -338 -537 -636 -753 -427 -159 -153 -100 -23 102 212 411 401 348 382 232 143 47 -38 -287 -384 -219 -280 -171 21 -142 -421 -366 -321 -419 -478 -459 -557 -501 -198 -198 -344 -249 -185 -127 -72 139 439 343 266 324 239 -65 -221 -493 -729 -751 -545 -110 -133 -375 -300 -307 -253 -35 76 7 183 322 446 600 818 891 616 447 401 205 268 522 336 159 328 266 199 430 226 -120 -70 -202 -448 -119 70 -192 -103 166 117 124 241 211 230 158 -97 -429 -532 -527 -502 SQ 20231128T012453.5Z 8732.058953 274 2 11.60 2 77.84 119.96 93.91 300.56 0.00 1 0.00 1 0 15 3.445e-03 3.432e-03 1.646e-04 1.644e-04 6.618293e+03 1.115153e+01 4.325244e+02 -6.000000e+00 2.015653e+02 291.00 -2.00 20.00 -2.00 505.33 0.00e+00 2.919319e-03 4.664765e-06 1.659396e-04 -6.000000e+00 9.955940e-05 291.00 -2.00 20.00 -2.00 500.69 0.00e+00 2.492672e-01 3.218665e-03 5.141866e-02 -6.000000e+00 6.814651e-02 225.27 -2.00 3.14 -2.00 502.25 0.00e+00 4.604 0.001 489.00 513.00 1 1.5934e+00 2.4769e-04 8.7745e-03 -6.0000e+00 5.2550e-03 -2.4975e-02 6.2361e-05 1.1480e-03 -6.0000e+00 1.3409e-03 1.9303e-01 -3.3085e-04 1.7139e-05 7.3213e-05 -6.0000e+00 3.7297e-04 5.7120e-03 3.0674e-05 10 0 0 10 0 0 96.08 23.87 1.39 0.00571 0.00342 513 88 1 4 0 22.590 26.32 20.01 23.87 31.07 9.9 1003.13 -633 -430 -167 -77 50 495 588 454 403 278 244 -13 -271 -307 -292 -370 -172 161 64 -73 148 262 255 462 481 386 433 132 -411 -340 -242 -438 -37 373 -51 -171 89 36 -108 -71 46 46 185 327 369 323 318 271 27 -314 -533 -651 -722 -452 -151 -172 -131 13 76 236 373 400 316 342 210 136 10 -41 -282 -389 -219 -292 -159 34 -166 -426 -382 -348 -443 -470 -452 -577 -506 -148 -182 -391 -236 -183 -129 -60 156 438 308 234 351 274 -56 -260 -531 -769 -777 -544 -130 -166 -391 -334 -307 -256 20 58 16 176 341 458 575 783 823 576 441 404 244 248 495 302 149 332 268 210 451 235 -132 -76 -199 -406 -94 62 -180 -103 173 104 103 257 249 237 154 -136 -399 -528 -529 -493 -603 -400 -160 -76 49 493 594 463 410 280 242 -13 -272 -305 -289 -369 -168 160 65 -75 153 270 264 479 501 402 448 135 -412 -332 -233 -427 -36 381 -52 -174 89 37 -111 -72 47 46 187 335 381 334 326 275 27 -317 -526 -632 -699 -444 -152 -171 -133 13 78 241 383 412 327 353 214 137 10 -40 -274 -389 -218 -292 -155 34 -164 -418 -369 -343 -434 -460 -444 -552 -488 -144 -179 -386 -232 -181 -127 -60 155 441 312 237 348 266 -53 -249 -501 -721 -734 -526 -125 -166 -397 -339 -309 -255 20 59 16 176 344 466 589 805 851 597 453 409 244 245 488 300 148 331 268 210 449 234 -130 -74 -197 -404 -91 61 -180 -105 179 108 104 261 254 242 157 -137 -407 -531 -527 -495 SQ 20231128T012505.2Z 8732.059088 274 3 11.60 2 77.80 119.98 93.95 300.58 0.00 1 0.00 1 0 15 3.470e-03 3.444e-03 1.507e-04 1.506e-04 6.569253e+03 1.021173e+01 4.264582e+02 -6.000000e+00 2.030106e+02 291.00 -2.00 20.00 -2.00 505.33 0.00e+00 2.910339e-03 4.285054e-06 1.657652e-04 -6.000000e+00 1.002735e-04 291.00 -2.00 20.00 -2.00 500.68 0.00e+00 2.418309e-01 2.953857e-03 5.145397e-02 -6.000000e+00 6.864066e-02 225.27 -2.00 3.14 -2.00 502.24 0.00e+00 4.590 0.001 489.00 513.00 1 1.4453e+00 2.2757e-04 8.7567e-03 -6.0000e+00 5.2930e-03 -2.4729e-02 5.7146e-05 1.1426e-03 -6.0000e+00 1.3508e-03 2.2445e-01 -3.0086e-04 1.5673e-05 7.3948e-05 -6.0000e+00 3.7565e-04 5.7589e-03 2.4661e-05 10 0 0 10 0 0 96.45 23.87 1.40 0.00576 0.00367 513 88 1 4 0 22.590 26.32 20.01 23.87 31.07 9.9 1003.56 -641 -461 -178 -87 60 505 568 446 381 270 239 -35 -280 -268 -302 -354 -165 159 71 -47 147 259 254 446 502 407 429 132 -380 -360 -280 -455 -63 366 -56 -151 70 64 -91 -32 52 45 215 336 375 352 324 251 29 -348 -543 -669 -740 -423 -144 -153 -106 -11 94 220 396 385 328 337 224 150 40 -52 -298 -401 -217 -279 -172 15 -121 -428 -389 -348 -436 -486 -482 -575 -516 -171 -211 -357 -244 -190 -118 -74 143 433 349 236 325 235 -64 -245 -522 -771 -797 -584 -148 -128 -406 -285 -287 -271 -9 86 28 181 322 429 596 804 831 574 476 373 226 243 513 345 147 318 265 214 443 271 -99 -44 -185 -429 -110 62 -178 -72 155 125 100 220 221 217 149 -124 -419 -515 -541 -518 -601 -439 -174 -85 60 514 588 450 383 277 242 -35 -278 -262 -295 -348 -165 161 71 -48 150 264 259 457 517 419 439 134 -377 -360 -276 -453 -62 369 -58 -157 72 66 -92 -32 53 46 223 341 384 361 330 261 30 -348 -531 -643 -709 -410 -143 -157 -106 -11 95 223 403 393 336 345 227 150 39 -52 -297 -396 -213 -276 -172 15 -119 -430 -385 -340 -423 -470 -469 -564 -510 -164 -206 -350 -239 -186 -115 -72 142 433 351 237 320 233 -63 -233 -488 -716 -746 -558 -146 -127 -408 -286 -286 -268 -9 86 28 180 324 434 606 821 854 591 486 375 224 246 518 340 146 316 263 212 438 267 -100 -44 -182 -423 -109 61 -177 -73 159 129 104 230 224 220 150 -128 -425 -514 -536 -516 SQ 20231128T012516.9Z 8732.059223 274 4 11.62 2 77.76 120.00 93.99 300.60 0.00 1 0.00 1 0 15 3.480e-03 3.461e-03 1.349e-04 1.347e-04 6.559827e+03 9.135498e+00 4.281456e+02 -6.000000e+00 2.036279e+02 291.00 -2.00 20.00 -2.00 505.33 0.00e+00 2.898445e-03 3.827769e-06 1.648306e-04 -6.000000e+00 1.005783e-04 291.00 -2.00 20.00 -2.00 500.69 0.00e+00 2.370594e-01 2.641984e-03 5.105174e-02 -6.000000e+00 6.884670e-02 225.27 -2.00 3.14 -2.00 502.25 0.00e+00 4.577 0.001 489.00 513.00 1 1.2558e+00 2.0341e-04 8.7169e-03 -6.0000e+00 5.3089e-03 -2.4659e-02 5.1134e-05 1.1379e-03 -6.0000e+00 1.3548e-03 2.7195e-01 -3.1556e-04 1.4043e-05 7.3280e-05 -6.0000e+00 3.7679e-04 6.0230e-03 2.5845e-05 10 0 0 10 0 0 93.90 23.87 1.39 0.00602 0.00383 513 88 1 4 0 22.590 26.32 20.01 23.87 31.07 9.9 1003.56 -636 -472 -159 -78 56 480 574 464 393 260 243 -44 -280 -263 -299 -361 -191 157 60 -45 142 264 281 470 518 387 407 132 -411 -361 -258 -457 -35 372 -45 -157 49 62 -108 -47 29 93 221 346 377 366 332 252 30 -341 -530 -660 -691 -435 -167 -150 -109 -46 69 227 389 399 333 351 220 131 33 -44 -324 -381 -216 -302 -144 0 -152 -421 -398 -343 -441 -525 -455 -556 -514 -166 -203 -372 -242 -185 -147 -83 148 443 347 249 344 239 -56 -260 -523 -778 -778 -586 -122 -148 -398 -315 -278 -244 -11 81 6 162 305 434 594 818 850 589 456 407 215 230 489 338 138 338 253 214 446 267 -121 -64 -168 -465 -111 64 -182 -101 165 93 82 261 238 215 137 -117 -407 -519 -541 -514 -599 -451 -151 -77 56 477 580 472 399 262 240 -45 -279 -259 -294 -358 -192 156 60 -47 146 271 290 486 538 391 421 135 -412 -351 -257 -445 -35 378 -46 -160 49 62 -111 -48 30 94 224 355 390 379 342 256 30 -344 -522 -640 -668 -426 -168 -150 -111 -47 71 233 400 412 345 362 225 132 33 -43 -317 -380 -215 -302 -141 0 -150 -414 -385 -337 -431 -513 -432 -533 -497 -162 -200 -368 -240 -183 -145 -82 148 447 353 252 342 233 -53 -249 -493 -729 -734 -566 -118 -148 -392 -310 -281 -244 -11 79 6 163 310 445 612 846 859 596 471 415 217 229 486 338 139 340 255 216 447 267 -120 -62 -162 -450 -108 63 -184 -101 166 95 84 269 245 221 141 -118 -406 -524 -543 -519 SQ 20231128T012528.6Z 8732.059359 274 5 11.59 2 77.72 120.03 94.02 300.62 0.00 1 0.00 1 0 22 3.443e-03 3.410e-03 1.781e-04 1.779e-04 6.564428e+03 1.210086e+01 4.281540e+02 -6.000000e+00 2.014402e+02 291.00 -2.00 20.00 -2.00 505.34 0.00e+00 2.927462e-03 5.075655e-06 1.667794e-04 -6.000000e+00 9.949765e-05 291.00 -2.00 20.00 -2.00 500.69 0.00e+00 2.380915e-01 3.493179e-03 5.121040e-02 -6.000000e+00 6.810231e-02 225.27 -2.00 3.14 -2.00 502.25 0.00e+00 4.564 0.001 489.00 513.00 1 1.7338e+00 2.6913e-04 8.7313e-03 -6.0000e+00 5.2516e-03 -2.4460e-02 6.7615e-05 1.1375e-03 -6.0000e+00 1.3400e-03 1.6885e-01 -3.4548e-04 1.8539e-05 7.4213e-05 -6.0000e+00 3.7273e-04 5.2378e-03 3.5609e-05 10 0 0 10 0 0 97.47 23.87 1.39 0.00524 0.00284 513 88 1 4 0 22.590 26.32 20.01 23.87 31.07 9.9 1003.56 -617 -464 -192 -82 67 494 589 466 374 271 207 -18 -288 -234 -310 -369 -177 176 49 -36 141 262 249 464 528 393 399 141 -412 -380 -276 -433 -38 360 -31 -125 75 24 -106 -52 26 69 186 309 372 349 299 277 19 -359 -528 -624 -718 -433 -147 -164 -94 -37 65 229 375 404 318 343 201 129 22 -36 -299 -399 -232 -287 -166 33 -116 -411 -359 -359 -449 -498 -428 -535 -489 -152 -210 -355 -266 -180 -103 -70 146 443 345 253 322 244 -77 -233 -519 -756 -822 -595 -124 -185 -378 -304 -321 -256 -7 93 15 177 330 429 575 804 851 544 434 376 221 226 514 365 146 333 234 221 436 255 -131 -93 -179 -451 -103 38 -183 -100 132 118 96 259 223 206 141 -118 -390 -536 -531 -505 -581 -443 -182 -80 67 504 610 469 375 279 210 -18 -285 -229 -303 -363 -177 179 49 -36 143 266 254 474 541 403 407 142 -406 -380 -273 -431 -37 362 -32 -130 77 24 -107 -53 27 71 192 323 392 355 314 286 19 -358 -514 -596 -686 -418 -146 -167 -98 -37 66 231 378 410 323 348 202 128 23 -36 -297 -393 -227 -283 -165 33 -117 -412 -354 -348 -433 -481 -414 -522 -481 -151 -210 -344 -259 -181 -103 -68 143 439 345 252 314 242 -74 -220 -483 -699 -766 -567 -122 -181 -377 -303 -317 -251 -7 92 15 181 340 444 578 812 864 554 438 388 225 228 515 368 148 339 239 225 442 257 -131 -92 -175 -441 -101 38 -180 -100 134 120 99 268 231 214 146 -120 -390 -529 -520 -497