File name: Pandora103s1_Downsview_20201118_L2Fit_ffus5c10d20181123p1-8.txt File generation date: 20241101T110322.7Z Data description: Level 2 spectral fitting results file Data file version: ffus5c10p1-8 Local principal investigator: Vitali Fioletov Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 103 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora103_OF_v10d20171016.txt Instrument calibration file used: Pandora103s1_CF_v10d20200901.txt Level 1 file used: Pandora103s1_Downsview_20201118_L1_smca1c10d20181123p1-8.txt Full location name: Environment Canada HQ - Downsview Short location name: Downsview Country of location: Canada Location latitude [deg]: 43.7810 Location longitude [deg]: -79.4680 Location altitude [m]: 187 Local noon date: 20201118 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, radiometric temperature correction, matrix method stray light correction (replaced by simple method) Data caveats: FieldAna 3rd VP - WinterReference but for LabData 2017 but L7 from 2023 First and last pixel inside fitting window: 326 591 Nominal wavelengths inside fitting window [nm]: 322.6115 322.7509 322.8903 323.0296 323.1690 323.3083 323.4477 323.5870 323.7263 323.8656 324.0049 324.1442 324.2834 324.4227 324.5620 324.7012 324.8404 324.9797 325.1189 325.2581 325.3973 325.5365 325.6757 325.8148 325.9540 326.0931 326.2323 326.3714 326.5105 326.6496 326.7887 326.9278 327.0669 327.2059 327.3450 327.4841 327.6231 327.7621 327.9011 328.0401 328.1791 328.3181 328.4571 328.5960 328.7350 328.8739 329.0129 329.1518 329.2907 329.4296 329.5685 329.7074 329.8462 329.9851 330.1239 330.2628 330.4016 330.5404 330.6792 330.8180 330.9568 331.0956 331.2343 331.3731 331.5118 331.6505 331.7893 331.9280 332.0666 332.2053 332.3440 332.4827 332.6213 332.7600 332.8986 333.0372 333.1758 333.3144 333.4530 333.5915 333.7301 333.8687 334.0072 334.1457 334.2842 334.4227 334.5612 334.6997 334.8382 334.9766 335.1151 335.2535 335.3919 335.5304 335.6688 335.8071 335.9455 336.0839 336.2222 336.3606 336.4989 336.6372 336.7755 336.9138 337.0521 337.1904 337.3287 337.4669 337.6052 337.7434 337.8816 338.0198 338.1580 338.2962 338.4343 338.5725 338.7106 338.8488 338.9869 339.1250 339.2631 339.4012 339.5393 339.6773 339.8154 339.9534 340.0914 340.2295 340.3675 340.5054 340.6434 340.7814 340.9193 341.0573 341.1952 341.3331 341.4710 341.6089 341.7468 341.8847 342.0226 342.1604 342.2982 342.4361 342.5739 342.7117 342.8495 342.9872 343.1250 343.2627 343.4005 343.5382 343.6759 343.8136 343.9513 344.0890 344.2267 344.3643 344.5019 344.6396 344.7772 344.9148 345.0524 345.1900 345.3275 345.4651 345.6026 345.7402 345.8777 346.0152 346.1527 346.2902 346.4276 346.5651 346.7025 346.8400 346.9774 347.1148 347.2522 347.3896 347.5269 347.6643 347.8017 347.9390 348.0763 348.2136 348.3509 348.4882 348.6255 348.7627 348.9000 349.0372 349.1744 349.3116 349.4488 349.5860 349.7232 349.8604 349.9975 350.1346 350.2718 350.4089 350.5460 350.6831 350.8201 350.9572 351.0942 351.2313 351.3683 351.5053 351.6423 351.7793 351.9163 352.0532 352.1902 352.3271 352.4640 352.6010 352.7379 352.8747 353.0116 353.1485 353.2853 353.4222 353.5590 353.6958 353.8326 353.9694 354.1062 354.2429 354.3797 354.5164 354.6531 354.7898 354.9265 355.0632 355.1999 355.3365 355.4732 355.6098 355.7465 355.8831 356.0197 356.1562 356.2928 356.4294 356.5659 356.7025 356.8390 356.9755 357.1120 357.2485 357.3849 357.5214 357.6578 357.7943 357.9307 358.0671 358.2035 358.3399 358.4762 358.6126 358.7489 358.8853 359.0216 359.1579 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Columns 167-432: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 433-698: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20201118T152437.6Z 7627.642102 128 1 51.18 2 67.13 154.74 97.92 117.93 0.00 1 0.00 1 0 33 2.118e-03 1.863e-03 1.977e-03 1.693e-03 -1.194041e-06 5.835866e-07 1.241800e-07 8.163798e-07 6.848418e-07 222.51 -2.00 3.57 -2.00 341.59 0.00e+00 1.849042e-04 1.612844e-04 2.935246e-05 2.781540e-04 1.908219e-04 276.68 -2.00 20.00 -2.00 339.23 0.00e+00 -4.597881e-05 2.337066e-05 4.940995e-06 5.460457e-05 3.220342e-05 276.68 -2.00 20.00 -2.00 347.42 0.00e+00 1.281115e-03 6.752251e-05 5.757745e-05 1.597187e-05 9.157415e-05 276.68 -2.00 20.00 -2.00 346.14 0.00e+00 2.115311e+05 1.469603e+05 4.039282e+04 4.257626e+05 1.754259e+05 258.70 -2.00 11.30 -2.00 352.23 0.00e+00 3.383344e-01 2.538756e-03 2.893893e-03 6.800997e-03 2.374816e-03 222.51 -2.00 3.57 -2.00 331.56 0.00e+00 8.099398e-03 3.775498e-03 1.477027e-03 4.207942e-04 2.732712e-03 276.68 -2.00 20.00 -2.00 329.78 0.00e+00 2.553 0.000 319.50 362.20 4 5.7450e+00 2.3639e-03 1.7768e-02 3.1097e-03 3.1175e-03 6.0230e-02 6.2221e-04 2.7836e-03 5.5167e-04 7.1208e-04 -7.6930e-03 1.1478e-03 7.3985e-04 1.9298e-04 1.3817e-03 -1.2223e-03 6.7982e-04 4.8912e-04 7.6478e-05 5.8649e-04 8.1436e-04 9.8227e-04 3.6075e-04 1.4488e-04 1.0497e-03 5.0152e-04 -4.8692e-03 1.5655e-03 3.2663e-04 1.4417e-04 1.8516e-03 -7.2976e-05 2.4744e-05 3.1357e-06 1.1539e-06 3.1906e-05 1.6387e-03 0.0000e+00 2.2265e-01 1.6966e-01 2.5106e-02 1.0204e-02 2.0639e-01 12 8 8 10 0 0 99.85 15.00 0.20 0.00164 0.00074 29 5 1 5 0 1764.520 21.88 15.00 18.74 -519 -368 313 518 310 149 64 192 462 -164 143 710 -556 -512 180 65 242 -529 -448 -257 -232 110 2 227 561 -45 73 119 -8 -208 -101 -145 -236 -103 127 71 -403 -604 240 364 -159 -162 293 -19 96 264 -165 150 133 68 -373 263 -384 -81 -169 -65 207 -127 154 -220 96 -275 108 -50 162 194 456 -155 37 -246 -32 32 -125 84 -258 101 -73 263 -35 -64 85 -119 215 258 60 -82 2 -39 111 486 -176 203 113 257 -250 -59 -409 64 -258 273 -434 -108 -165 153 343 110 341 -21 134 -142 184 129 166 -22 -74 125 233 37 142 -146 -23 -335 -135 27 106 -180 108 -119 34 -59 -322 58 -102 -192 -273 255 -124 -95 -233 -28 -23 73 -222 81 -55 -254 53 -212 119 73 450 -49 -249 178 196 -6 -182 -227 20 -161 160 9 394 87 319 204 166 10 -12 -477 -43 -57 6 -24 59 276 -181 75 -95 186 74 50 -181 275 -166 82 -108 -69 -9 -382 29 -85 -144 -145 -127 94 -135 -256 83 -38 -9 -222 171 -198 79 -96 -25 52 140 308 57 266 183 -24 387 236 -208 161 -44 -196 -271 143 156 38 -21 105 88 -112 -65 114 12 -63 114 207 -6 -95 1 -92 -150 -163 -62 -237 -191 -318 52 68 163 -19 -98 -168 148 80 234 42 163 -6 141 90 -74 -128 -92 -100 137 -37 -70 77 -188 -129 112 199 128 65 28 88 220 -82 75 376 -302 -279 95 33 119 -260 -228 -139 -135 68 1 157 398 -33 53 86 -6 -154 -76 -108 -172 -74 92 51 -287 -419 162 245 -109 -113 204 -13 69 202 -135 130 119 61 -343 242 -360 -75 -153 -57 167 -99 120 -175 78 -227 88 -41 134 166 402 -139 32 -211 -28 28 -112 75 -228 89 -65 230 -29 -52 69 -99 186 231 56 -79 2 -37 101 445 -167 202 116 264 -245 -52 -320 48 -206 239 -403 -98 -141 122 265 88 292 -20 132 -140 173 117 151 -21 -75 129 243 38 144 -143 -22 -324 -137 29 120 -208 124 -135 37 -63 -336 60 -106 -201 -280 253 -122 -97 -252 -31 -27 82 -245 88 -60 -287 62 -250 138 83 504 -55 -273 181 179 -5 -147 -193 18 -159 169 10 448 100 367 235 189 11 -12 -485 -44 -61 7 -28 68 327 -217 88 -106 193 74 51 -195 311 -191 93 -121 -79 -10 -437 32 -90 -150 -155 -136 101 -151 -303 104 -51 -12 -293 223 -254 99 -119 -30 60 159 363 71 343 235 -29 443 252 -215 170 -50 -237 -341 181 199 49 -27 141 118 -149 -87 151 16 -85 155 282 -8 -128 1 -117 -188 -205 -78 -302 -246 -418 66 81 181 -19 -98 -169 151 85 265 49 189 -6 141 82 -65 -110 -80 -88 126 -38 -80 93 SS 20201118T181727.5Z 7627.762124 221 1 17.04 2 65.49 199.26 76.09 148.71 0.00 1 0.00 1 0 33 1.638e-03 1.620e-03 9.765e-04 9.034e-04 2.383979e-06 3.040358e-07 7.512714e-08 8.164056e-07 5.302459e-07 222.51 -2.00 3.57 -2.00 340.67 0.00e+00 -3.967993e-04 8.451073e-05 1.372172e-05 2.780158e-04 1.485464e-04 276.67 -2.00 20.00 -2.00 338.17 0.00e+00 2.051422e-04 1.246069e-05 3.314182e-06 5.460204e-05 2.482682e-05 276.67 -2.00 20.00 -2.00 346.72 0.00e+00 9.932493e-04 3.608412e-05 5.330749e-05 1.611656e-05 7.087867e-05 276.67 -2.00 20.00 -2.00 345.42 0.00e+00 -6.340490e+05 7.621057e+04 4.678303e+04 4.257427e+05 1.362962e+05 258.68 -2.00 11.30 -2.00 352.28 0.00e+00 3.061085e-01 1.224142e-03 2.663058e-03 6.798683e-03 1.819880e-03 222.51 -2.00 3.57 -2.00 330.71 0.00e+00 -8.972168e-04 1.718551e-03 1.380980e-03 4.047154e-04 2.110059e-03 276.67 -2.00 20.00 -2.00 328.76 0.00e+00 2.394 0.000 319.50 362.20 4 4.2311e+00 1.2710e-03 1.6642e-02 3.1095e-03 2.4229e-03 2.6273e-02 3.2077e-04 2.6014e-03 5.5226e-04 5.5731e-04 -2.6215e-03 5.9636e-04 6.3677e-04 1.8241e-04 1.0676e-03 -1.8016e-03 3.2141e-04 4.7286e-04 7.6965e-05 4.5444e-04 2.7338e-03 4.9447e-04 3.9220e-04 1.3627e-04 8.1654e-04 2.5646e-03 -4.4617e-03 8.0945e-04 3.2654e-04 1.6069e-04 1.4296e-03 4.3129e-05 1.2987e-05 3.0894e-06 1.1431e-06 2.4686e-05 6.8519e-04 0.0000e+00 -1.1173e-01 8.9619e-02 2.6548e-02 1.1239e-02 1.6145e-01 12 9 9 12 1 1 99.85 15.00 0.14 0.00069 0.00122 14 8 1 5 0 1123.790 21.88 15.00 18.75 -65 125 521 94 417 364 -46 -156 -96 92 -99 82 -186 -296 -200 -178 -468 130 -111 -192 -17 56 56 -4 -8 352 228 37 228 4 -129 -22 -117 -188 -41 -244 -189 -77 15 52 230 100 236 214 75 148 146 -50 106 14 -128 -143 -265 -53 -115 -37 -272 -121 -238 107 -231 -46 -8 102 160 104 47 115 66 112 93 98 138 81 174 -85 -44 0 72 -53 -112 -140 -219 -82 -51 -204 127 -239 228 251 -70 -148 -178 -47 10 -21 247 101 231 -26 105 -86 -32 344 228 407 -1 189 -21 87 -73 -22 53 -99 -113 2 -150 -158 47 -16 31 -20 163 13 72 144 54 -121 229 -76 26 -67 -37 -67 -91 -135 -73 -222 -156 -349 -76 -42 -122 -3 -40 9 59 148 18 79 133 30 115 64 256 312 69 78 11 -5 71 -173 45 84 -16 9 -141 -25 15 172 61 -58 56 -113 136 9 17 -31 -110 -124 53 -67 -6 38 -29 -65 21 83 4 -90 -90 -125 -213 -211 -199 -126 -257 -239 -44 291 409 615 197 -24 28 -73 -169 -251 -143 -126 -90 -88 205 -192 -27 -46 -49 -80 -152 -209 -76 34 28 11 -27 -222 134 147 -166 -70 -82 207 322 187 184 402 525 -166 -167 111 -133 46 172 249 -80 -82 -392 -104 -79 -42 -83 20 -39 -173 -20 -136 12 -216 157 -149 -9 217 87 -42 -15 0 -32 59 252 48 225 203 -26 -90 -57 57 -63 53 -122 -194 -129 -112 -287 79 -70 -125 -12 40 42 -3 -6 282 182 30 182 4 -106 -18 -94 -150 -32 -196 -150 -60 12 40 178 78 184 167 60 123 127 -45 98 13 -120 -136 -254 -51 -108 -34 -236 -102 -201 92 -202 -41 -7 89 141 94 44 106 60 101 84 90 128 75 159 -78 -41 0 64 -46 -97 -124 -200 -76 -49 -199 124 -230 215 238 -68 -148 -183 -49 10 -20 209 82 198 -24 100 -81 -29 296 192 349 -1 182 -21 87 -70 -21 51 -97 -115 2 -156 -164 48 -16 30 -20 166 14 80 161 60 -133 246 -80 27 -70 -39 -70 -93 -136 -73 -226 -166 -386 -85 -47 -131 -3 -43 10 66 168 20 88 146 33 123 66 243 280 60 70 11 -5 74 -190 50 93 -18 10 -157 -27 15 176 64 -62 61 -125 153 10 20 -35 -120 -130 53 -69 -6 42 -32 -72 23 92 4 -101 -98 -132 -222 -224 -212 -135 -282 -272 -52 357 506 755 240 -29 34 -85 -193 -279 -159 -143 -107 -107 247 -226 -30 -49 -51 -84 -168 -243 -91 40 34 13 -33 -276 166 182 -205 -87 -103 260 404 234 231 500 640 -199 -199 132 -159 55 208 306 -96 -95 -430 -109 -81 -43 -86 21 -43 -197 -22 -149 12 -208 146 -136 -8 201 84 -43 -17 0 SS 20201118T182310.0Z 7627.766088 224 1 6.07 2 65.84 200.68 75.58 149.88 0.00 1 0.00 1 0 33 3.137e-03 3.442e-03 4.101e-04 3.825e-04 5.740834e-06 1.286013e-07 1.448001e-07 8.163869e-07 1.016036e-06 222.51 -2.00 3.57 -2.00 340.63 0.00e+00 -1.127163e-03 3.598604e-05 2.724843e-05 2.780360e-04 2.863375e-04 276.67 -2.00 20.00 -2.00 338.12 0.00e+00 6.019997e-04 5.235444e-06 2.137573e-06 5.460307e-05 4.726794e-05 276.67 -2.00 20.00 -2.00 346.70 0.00e+00 5.917856e-04 1.525203e-05 4.493880e-05 1.609145e-05 1.359114e-04 276.67 -2.00 20.00 -2.00 345.42 0.00e+00 -1.311413e+06 3.230206e+04 6.755837e+04 4.257305e+05 2.629667e+05 258.68 -2.00 11.30 -2.00 352.37 0.00e+00 3.099145e-01 5.160025e-04 2.724438e-03 6.798483e-03 3.498511e-03 222.51 -2.00 3.57 -2.00 330.59 0.00e+00 -3.394418e-03 7.093590e-04 1.718121e-03 4.004066e-04 4.048426e-03 276.67 -2.00 20.00 -2.00 328.61 0.00e+00 2.427 0.000 319.50 362.20 4 1.6106e+00 5.3945e-04 1.6813e-02 3.1099e-03 4.6407e-03 3.2906e-03 1.3696e-04 2.6263e-03 5.5249e-04 1.0818e-03 3.9281e-04 2.5284e-04 6.3008e-04 1.8197e-04 2.0486e-03 -2.1871e-03 1.3346e-04 4.8830e-04 7.7182e-05 8.7336e-04 4.1123e-03 2.0862e-04 4.2456e-04 1.3633e-04 1.5763e-03 3.4895e-02 -6.9175e-03 3.3508e-04 3.4948e-04 1.6394e-04 2.6834e-03 -4.3687e-05 5.4627e-06 3.3036e-06 1.1493e-06 4.7261e-05 1.9766e-03 0.0000e+00 -1.0676e-01 3.7593e-02 2.9281e-02 1.1317e-02 3.0661e-01 12 9 9 12 1 1 97.29 15.00 0.18 0.00198 0.00144 61 99 1 5 0 95.110 21.88 15.00 18.75 295 522 364 358 -24 34 -30 29 -87 -59 -140 -126 -234 -403 -333 -348 -279 -114 -111 -47 -44 -67 41 112 286 227 335 285 383 193 93 25 9 -22 -201 -120 -235 -31 -79 -1 34 110 98 284 169 185 -4 -12 -103 -194 -197 -156 -234 -235 -298 -294 -172 -107 -98 -190 -136 -151 63 168 123 42 86 149 211 272 269 217 133 193 215 217 96 -75 -150 -148 -267 -246 -347 -296 -329 -291 -244 -128 -41 -7 19 -31 -64 -119 -23 154 371 656 565 200 205 248 272 432 486 468 248 25 -57 -10 73 102 -11 -259 -398 -426 -371 -316 -89 -61 202 238 216 210 104 102 160 132 148 102 202 57 -48 -160 -199 -318 -452 -502 -543 -569 -454 -321 -224 -46 2 99 67 207 222 299 249 99 140 130 318 363 522 320 251 178 129 17 -1 46 29 2 -63 -85 42 86 -17 -21 37 35 7 65 -63 -21 -153 25 73 39 11 5 -40 11 68 46 -133 -230 -224 -202 -202 -401 -358 -267 -266 -308 -22 565 921 1259 424 -259 -269 -362 -461 -425 -358 -366 -384 -104 225 -140 -405 -347 -236 -238 -383 -471 6 122 -42 -164 -265 -552 493 713 -311 -665 -393 672 1250 596 688 855 1391 -481 -292 275 -366 70 408 827 -123 -437 -458 -312 -204 -253 -163 -260 -241 -279 -238 -330 -160 -83 47 71 123 43 114 78 -63 48 155 262 188 191 -14 20 -18 18 -53 -38 -91 -84 -158 -273 -220 -221 -177 -72 -73 -32 -31 -49 31 86 226 183 268 226 308 159 76 21 7 -18 -160 -96 -185 -25 -60 -1 26 87 78 224 134 156 -4 -11 -94 -181 -186 -144 -220 -220 -278 -268 -149 -92 -84 -162 -119 -134 55 146 110 38 80 135 193 242 242 200 125 180 198 201 90 -69 -135 -128 -229 -219 -313 -279 -313 -278 -236 -124 -38 -6 18 -31 -65 -120 -22 141 313 542 489 183 193 236 247 375 407 405 228 24 -57 -9 70 98 -11 -256 -405 -431 -383 -326 -91 -60 199 236 222 219 113 113 176 142 157 107 208 59 -50 -167 -201 -319 -448 -515 -571 -619 -499 -345 -240 -48 2 107 76 230 250 329 269 109 150 131 309 329 469 293 244 179 138 19 -1 51 33 3 -71 -93 44 87 -18 -23 40 39 7 74 -72 -24 -167 26 74 40 12 6 -45 12 75 51 -149 -254 -245 -215 -211 -431 -387 -284 -287 -348 -26 681 1120 1507 517 -312 -315 -427 -532 -480 -403 -420 -450 -125 267 -161 -452 -376 -244 -253 -421 -552 7 144 -50 -198 -321 -685 609 875 -377 -811 -484 833 1546 745 860 1054 1689 -576 -345 322 -438 84 489 1011 -147 -504 -511 -328 -213 -265 -169 -280 -273 -323 -272 -364 -164 -81 45 66 116 41 111 82 -70 56 SS 20201118T182941.2Z 7627.770616 227 1 50.36 2 66.28 202.30 75.02 151.24 0.00 1 0.00 1 0 33 7.043e-04 6.266e-04 5.955e-04 5.269e-04 7.218932e-08 1.800540e-07 8.815286e-08 8.163746e-07 2.279324e-07 222.51 -2.00 3.57 -2.00 341.25 0.00e+00 1.265027e-04 5.010679e-05 1.744558e-05 2.781307e-04 6.388520e-05 276.67 -2.00 20.00 -2.00 338.80 0.00e+00 -2.201104e-05 7.243004e-06 4.672049e-06 5.460401e-05 1.067262e-05 276.67 -2.00 20.00 -2.00 347.20 0.00e+00 1.172869e-03 2.100260e-05 5.684260e-05 1.600807e-05 3.047403e-05 276.67 -2.00 20.00 -2.00 345.92 0.00e+00 1.714655e+05 4.535816e+04 4.442881e+04 4.257402e+05 5.860872e+04 258.68 -2.00 11.30 -2.00 352.36 0.00e+00 3.100871e-01 7.616585e-04 2.624391e-03 6.800385e-03 7.853510e-04 222.51 -2.00 3.57 -2.00 331.23 0.00e+00 3.751575e-04 1.106078e-03 1.735255e-03 4.155415e-04 9.076879e-04 276.67 -2.00 20.00 -2.00 329.38 0.00e+00 2.468 0.000 319.50 362.20 4 3.9814e+00 7.3929e-04 1.7171e-02 3.1096e-03 1.0376e-03 2.4653e-02 1.9481e-04 2.6844e-03 5.5205e-04 2.4068e-04 -9.3797e-04 3.5368e-04 6.7393e-04 1.8946e-04 4.5911e-04 -1.5192e-03 2.0236e-04 4.9791e-04 7.6490e-05 1.9567e-04 5.3335e-04 3.0009e-04 4.3204e-04 1.4274e-04 3.5148e-04 3.1080e-03 9.0764e-04 4.8275e-04 3.1142e-04 1.4930e-04 6.0720e-04 -3.8902e-06 7.6216e-06 2.9497e-06 1.1405e-06 1.0613e-05 9.0532e-04 0.0000e+00 -2.8581e-01 5.2634e-02 2.4714e-02 1.0535e-02 6.9020e-02 11 8 0 10 0 0 99.94 15.00 0.22 0.00091 0.00086 97 18 1 5 0 519.010 21.88 15.00 18.75 -5 -195 116 -17 87 -1 141 118 -21 83 -98 50 -137 -139 -10 -65 -78 93 -20 156 -101 91 -24 181 -9 130 -5 142 -60 -99 -3 -81 -167 -105 -61 -140 -98 -156 121 -34 72 42 171 14 60 -67 73 18 74 -31 -19 -59 -55 -38 10 -95 20 0 -31 -100 -51 22 64 118 114 186 108 65 21 74 -95 61 28 -19 5 159 46 4 -1 -16 -14 -30 137 1 75 12 7 -26 20 -167 52 -39 -132 -21 24 -51 5 26 -129 -73 -118 -42 -1 -53 -53 57 -166 -28 38 34 -38 -26 19 19 49 83 79 -28 94 0 -77 47 -32 -40 29 -30 -9 -107 10 -40 -31 -83 -27 -16 16 -44 149 -49 -64 -48 91 76 22 1 40 -16 -59 -10 70 -30 33 75 -95 -10 -5 -67 -106 -32 -77 -50 -28 6 70 103 17 105 -16 100 23 39 46 -47 35 36 56 17 59 17 12 -79 58 -74 83 -32 65 -61 28 -4 -40 -10 5 -16 -15 -63 -42 41 40 -19 -8 41 -81 -16 -61 2 19 28 -69 57 29 -16 -12 26 28 -48 -54 31 -1 46 9 -60 -8 -44 -35 49 58 38 27 -6 1 39 10 -65 -64 -71 33 -60 -63 3 -20 37 -53 60 -16 49 2 30 -88 90 109 -57 -46 99 -82 24 11 12 -8 127 31 150 -134 -4 -48 -1 -2 -35 -2 -77 47 -8 42 -1 67 58 -11 45 -56 29 -81 -82 -6 -36 -41 49 -11 91 -64 58 -16 132 -6 99 -4 106 -45 -77 -2 -63 -127 -79 -46 -105 -72 -112 84 -24 51 30 123 10 45 -53 63 16 66 -28 -18 -55 -52 -36 9 -82 16 0 -25 -83 -43 19 54 99 98 167 95 57 18 66 -86 52 25 -17 5 146 41 4 -1 -14 -12 -26 123 1 69 12 6 -24 18 -151 49 -39 -138 -22 23 -47 4 21 -103 -66 -107 -40 -1 -42 -44 46 -147 -26 37 34 -35 -25 18 18 50 86 83 -30 95 0 -73 45 -32 -44 32 -34 -11 -117 11 -43 -32 -86 -29 -17 17 -44 146 -49 -70 -54 101 83 24 1 44 -18 -68 -11 80 -34 36 81 -101 -11 -5 -57 -87 -27 -73 -49 -31 6 79 116 19 119 -18 107 24 40 48 -49 38 41 64 20 71 20 13 -85 59 -77 87 -36 75 -68 31 -5 -47 -12 5 -16 -16 -66 -44 44 45 -21 -9 52 -103 -20 -79 3 24 34 -79 66 34 -18 -15 32 34 -58 -61 33 -2 49 10 -73 -10 -54 -43 61 74 50 36 -8 1 51 13 -84 -83 -92 43 -77 -82 4 -25 46 -66 76 -19 62 3 36 -100 94 109 -57 -47 109 -93 29 12 13 -8 123 28 134 -122 -4 -45 -1 -2 -42 SS 20201118T183604.4Z 7627.775051 230 1 42.76 2 66.73 203.86 74.49 152.59 0.00 1 0.00 1 0 33 1.280e-03 1.195e-03 1.166e-03 1.048e-03 6.835409e-07 3.561413e-07 8.519969e-08 8.163934e-07 4.139870e-07 222.51 -2.00 3.57 -2.00 341.05 0.00e+00 -1.898866e-04 9.877768e-05 1.692660e-05 2.780722e-04 1.156635e-04 276.67 -2.00 20.00 -2.00 338.60 0.00e+00 8.597867e-05 1.445040e-05 4.506523e-06 5.460297e-05 1.942537e-05 276.67 -2.00 20.00 -2.00 347.01 0.00e+00 1.150109e-03 4.178096e-05 5.707963e-05 1.605916e-05 5.534361e-05 276.67 -2.00 20.00 -2.00 345.72 0.00e+00 -2.910674e+05 8.940167e+04 4.762245e+04 4.257470e+05 1.062352e+05 258.68 -2.00 11.30 -2.00 352.27 0.00e+00 3.220130e-01 1.482428e-03 2.747944e-03 6.799700e-03 1.429912e-03 222.51 -2.00 3.57 -2.00 331.08 0.00e+00 -1.892012e-04 2.138844e-03 1.820451e-03 4.116342e-04 1.647950e-03 276.67 -2.00 20.00 -2.00 329.19 0.00e+00 2.512 0.000 319.50 362.20 4 5.1294e+00 1.4678e-03 1.7473e-02 3.1096e-03 1.8903e-03 4.4571e-02 3.7743e-04 2.7340e-03 5.5205e-04 4.3388e-04 -7.2263e-03 6.9954e-04 6.8410e-04 1.8672e-04 8.3465e-04 -1.9364e-03 3.9321e-04 5.1947e-04 7.6838e-05 3.5466e-04 3.2639e-03 5.8834e-04 4.4635e-04 1.3990e-04 6.3651e-04 9.6226e-04 -7.5339e-03 9.4620e-04 3.2521e-04 1.5343e-04 1.1213e-03 4.8078e-05 1.5160e-05 3.0801e-06 1.1399e-06 1.9283e-05 3.1034e-04 0.0000e+00 -7.3951e-02 1.0409e-01 2.6018e-02 1.0720e-02 1.2526e-01 12 9 9 12 1 1 99.93 15.00 0.16 0.00031 0.00090 15 4 1 5 0 2661.300 21.88 15.00 18.75 -14 235 315 239 5 455 173 -136 -33 48 -207 135 -312 -390 -203 -202 -131 13 55 169 62 122 98 41 8 7 14 57 85 142 135 -190 -7 -205 -219 -393 -178 -155 251 -66 93 -41 126 123 126 27 61 66 -32 66 -40 -97 -88 215 -46 6 -167 -72 -123 -27 -62 1 -162 45 218 271 -40 -30 -45 -28 95 10 6 54 166 -16 135 52 -93 -142 21 -220 75 -67 111 -256 -48 115 -39 3 -35 -8 -62 175 -122 158 136 -57 108 -52 -7 127 219 41 281 -38 158 81 25 4 93 110 -52 -91 31 -47 -15 -161 120 -95 89 5 0 -22 0 97 -8 -85 -68 -42 -62 -46 -17 -257 -133 109 -134 -83 -204 -86 -125 -36 -75 -35 -45 -116 -23 130 79 117 55 201 -150 10 -69 244 39 -63 -57 0 21 89 142 -59 137 18 -69 55 84 152 93 -148 -5 6 251 -23 -58 -98 95 -77 65 -67 72 -53 167 -2 43 -53 -111 -51 -158 -221 -81 -128 -132 -96 -11 -66 -84 180 259 230 60 -62 186 -147 -89 -164 22 7 -53 117 95 -61 -18 -89 48 -56 12 -110 -54 -28 22 -4 -60 -21 17 63 11 127 -142 38 279 93 82 114 322 -155 -263 72 -114 51 -178 -1 11 -76 -122 -81 -170 -138 105 47 -57 -61 -60 -9 166 185 8 -78 -40 -156 75 61 74 26 -6 97 133 108 2 227 88 -71 -18 27 -121 80 -188 -236 -121 -116 -73 7 31 101 39 83 69 30 6 6 11 43 65 111 107 -149 -5 -157 -168 -303 -135 -115 183 -48 68 -30 94 92 97 21 52 58 -29 61 -37 -91 -83 203 -43 5 -141 -59 -101 -22 -53 1 -138 38 188 240 -37 -27 -40 -25 84 9 6 49 150 -14 123 47 -81 -120 18 -191 67 -61 105 -248 -47 110 -37 2 -33 -8 -64 179 -121 143 112 -45 90 -47 -7 118 193 34 229 -32 140 77 25 4 89 103 -49 -89 32 -49 -16 -168 122 -94 87 5 0 -24 0 110 -9 -94 -73 -44 -65 -47 -18 -269 -137 109 -133 -85 -219 -95 -141 -40 -82 -38 -48 -129 -27 149 90 131 61 221 -163 10 -65 214 33 -55 -54 0 22 99 159 -66 155 21 -78 60 88 155 97 -159 -5 7 284 -26 -68 -113 105 -80 66 -68 77 -59 189 -2 47 -59 -126 -58 -174 -234 -84 -136 -142 -104 -12 -77 -102 228 330 290 75 -77 225 -177 -104 -185 24 8 -64 146 117 -73 -20 -96 50 -59 13 -130 -65 -35 27 -5 -75 -26 22 80 14 162 -183 49 361 121 106 146 403 -191 -320 87 -140 63 -221 -2 13 -89 -135 -85 -173 -141 108 50 -64 -70 -68 -10 168 175 7 -70 -36 -143 71 63 83 30