File name: Pandora174s1_FairbanksAK_20220218_L2Fit_fnvs5c2d20210103p1-8.txt File generation date: 20251118T235858.5Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c2p1-8 Local principal investigator: Jingqiu Mao Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 174 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora174_OF_v4d20200215.txt Instrument calibration file used: Pandora174s1_CF_v2d20210103.txt Level 1 file used: Pandora174s1_FairbanksAK_20220218_L1_smca1c2d20210103p1-8.txt Full location name: University of Alaska Fairbanks campus Short location name: FairbanksAK Country of location: USA Location latitude [deg]: 64.8594 Location longitude [deg]: -147.8499 Location altitude [m]: 227 Local noon date: 20220218 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 925 1470 Nominal wavelengths inside fitting window [nm]: 400.0986 400.2309 400.3631 400.4953 400.6275 400.7597 400.8919 401.0240 401.1562 401.2883 401.4204 401.5525 401.6846 401.8167 401.9487 402.0808 402.2128 402.3448 402.4768 402.6088 402.7408 402.8727 403.0047 403.1366 403.2685 403.4004 403.5323 403.6642 403.7960 403.9279 404.0597 404.1915 404.3233 404.4551 404.5868 404.7186 404.8503 404.9821 405.1138 405.2455 405.3772 405.5088 405.6405 405.7721 405.9038 406.0354 406.1670 406.2986 406.4301 406.5617 406.6932 406.8248 406.9563 407.0878 407.2193 407.3507 407.4822 407.6136 407.7451 407.8765 408.0079 408.1393 408.2706 408.4020 408.5333 408.6647 408.7960 408.9273 409.0586 409.1898 409.3211 409.4523 409.5835 409.7148 409.8460 409.9771 410.1083 410.2395 410.3706 410.5017 410.6328 410.7639 410.8950 411.0261 411.1572 411.2882 411.4192 411.5502 411.6812 411.8122 411.9432 412.0741 412.2051 412.3360 412.4669 412.5978 412.7287 412.8596 412.9904 413.1213 413.2521 413.3829 413.5137 413.6445 413.7752 413.9060 414.0367 414.1675 414.2982 414.4289 414.5596 414.6902 414.8209 414.9515 415.0821 415.2127 415.3433 415.4739 415.6045 415.7350 415.8656 415.9961 416.1266 416.2571 416.3876 416.5181 416.6485 416.7789 416.9094 417.0398 417.1702 417.3005 417.4309 417.5613 417.6916 417.8219 417.9522 418.0825 418.2128 418.3431 418.4733 418.6035 418.7338 418.8640 418.9942 419.1243 419.2545 419.3846 419.5148 419.6449 419.7750 419.9051 420.0352 420.1652 420.2953 420.4253 420.5553 420.6853 420.8153 420.9453 421.0752 421.2052 421.3351 421.4650 421.5949 421.7248 421.8547 421.9845 422.1144 422.2442 422.3740 422.5038 422.6336 422.7634 422.8931 423.0229 423.1526 423.2823 423.4120 423.5417 423.6713 423.8010 423.9306 424.0602 424.1898 424.3194 424.4490 424.5786 424.7081 424.8377 424.9672 425.0967 425.2262 425.3557 425.4851 425.6146 425.7440 425.8734 426.0028 426.1322 426.2616 426.3909 426.5203 426.6496 426.7789 426.9082 427.0375 427.1668 427.2960 427.4253 427.5545 427.6837 427.8129 427.9421 428.0712 428.2004 428.3295 428.4586 428.5877 428.7168 428.8459 428.9750 429.1040 429.2330 429.3621 429.4911 429.6201 429.7490 429.8780 430.0069 430.1359 430.2648 430.3937 430.5225 430.6514 430.7803 430.9091 431.0379 431.1667 431.2955 431.4243 431.5531 431.6818 431.8106 431.9393 432.0680 432.1967 432.3253 432.4540 432.5826 432.7113 432.8399 432.9685 433.0971 433.2256 433.3542 433.4827 433.6113 433.7398 433.8683 433.9967 434.1252 434.2537 434.3821 434.5105 434.6389 434.7673 434.8957 435.0240 435.1524 435.2807 435.4090 435.5373 435.6656 435.7939 435.9221 436.0504 436.1786 436.3068 436.4350 436.5632 436.6914 436.8195 436.9476 437.0758 437.2039 437.3320 437.4600 437.5881 437.7161 437.8442 437.9722 438.1002 438.2282 438.3561 438.4841 438.6120 438.7399 438.8678 438.9957 439.1236 439.2515 439.3793 439.5072 439.6350 439.7628 439.8906 440.0183 440.1461 440.2738 440.4016 440.5293 440.6570 440.7847 440.9123 441.0400 441.1676 441.2952 441.4228 441.5504 441.6780 441.8056 441.9331 442.0606 442.1882 442.3157 442.4431 442.5706 442.6981 442.8255 442.9529 443.0803 443.2077 443.3351 443.4625 443.5898 443.7171 443.8445 443.9718 444.0991 444.2263 444.3536 444.4808 444.6081 444.7353 444.8625 444.9896 445.1168 445.2440 445.3711 445.4982 445.6253 445.7524 445.8795 446.0065 446.1336 446.2606 446.3876 446.5146 446.6416 446.7686 446.8955 447.0225 447.1494 447.2763 447.4032 447.5301 447.6569 447.7838 447.9106 448.0374 448.1642 448.2910 448.4178 448.5446 448.6713 448.7980 448.9247 449.0514 449.1781 449.3048 449.4314 449.5580 449.6847 449.8113 449.9379 450.0644 450.1910 450.3175 450.4441 450.5706 450.6971 450.8235 450.9500 451.0765 451.2029 451.3293 451.4557 451.5821 451.7085 451.8348 451.9612 452.0875 452.2138 452.3401 452.4664 452.5927 452.7189 452.8452 452.9714 453.0976 453.2238 453.3500 453.4761 453.6023 453.7284 453.8545 453.9806 454.1067 454.2327 454.3588 454.4848 454.6109 454.7369 454.8629 454.9888 455.1148 455.2407 455.3667 455.4926 455.6185 455.7444 455.8702 455.9961 456.1219 456.2477 456.3735 456.4993 456.6251 456.7509 456.8766 457.0023 457.1281 457.2538 457.3794 457.5051 457.6308 457.7564 457.8820 458.0076 458.1332 458.2588 458.3843 458.5099 458.6354 458.7609 458.8864 459.0119 459.1374 459.2628 459.3883 459.5137 459.6391 459.7645 459.8898 460.0152 460.1405 460.2659 460.3912 460.5165 460.6418 460.7670 460.8923 461.0175 461.1427 461.2679 461.3931 461.5183 461.6434 461.7686 461.8937 462.0188 462.1439 462.2690 462.3940 462.5191 462.6441 462.7691 462.8941 463.0191 463.1441 463.2690 463.3940 463.5189 463.6438 463.7687 463.8936 464.0184 464.1433 464.2681 464.3929 464.5177 464.6425 464.7672 464.8920 465.0167 465.1414 465.2661 465.3908 465.5155 465.6401 465.7648 465.8894 466.0140 466.1386 466.2632 466.3877 466.5123 466.6368 466.7613 466.8858 467.0103 467.1347 467.2592 467.3836 467.5080 467.6324 467.7568 467.8812 468.0055 468.1299 468.2542 468.3785 468.5028 468.6271 468.7513 468.8756 468.9998 469.1240 469.2482 469.3724 469.4965 469.6207 469.7448 469.8689 469.9930 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-709: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 710-1255: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20220219T005820.7Z 8085.040517 519 1 24.52 2 82.81 222.64 110.57 16.38 0.00 1 0.00 1 0 49 2.063e-03 1.795e-03 1.424e-03 1.289e-03 7.219970e+02 2.210855e+02 5.942482e+01 3.451621e+02 3.698263e+02 257.18 -2.00 20.00 -2.00 448.40 0.00e+00 2.341487e-04 1.499328e-04 9.891635e-06 1.647518e-05 2.209641e-04 257.18 -2.00 20.00 -2.00 457.11 0.00e+00 3.987368e-04 1.148512e-05 3.771117e-06 4.867267e-06 1.857049e-05 224.54 -2.00 3.02 -2.00 440.99 0.00e+00 1.869984e+06 1.706099e+05 1.437504e+04 2.339065e+05 2.890641e+05 244.16 -2.00 11.98 -2.00 458.79 0.00e+00 1.201489e+00 3.267567e-02 5.502957e-03 8.992201e-03 6.360168e-02 220.92 -2.00 4.56 -2.00 456.45 0.00e+00 -8.302410e-07 4.189377e-06 7.632312e-07 1.191182e-06 7.848158e-06 257.18 -2.00 20.00 -2.00 457.15 0.00e+00 7.381 0.011 397.00 473.00 4 6.1889e+00 1.4125e-03 1.8394e-02 4.0908e-04 2.1081e-03 -4.3158e-03 1.8460e-03 3.8414e-03 2.6521e-04 2.7291e-03 -4.0317e-03 9.4082e-04 5.0537e-04 1.0140e-04 1.3924e-03 5.5572e-03 3.4515e-04 7.1413e-05 2.6272e-05 5.0394e-04 -2.3604e-03 1.7564e-04 4.0560e-05 1.6909e-05 2.4919e-04 8.6163e-06 -4.2182e-02 7.7355e-04 3.4012e-05 3.6131e-05 1.1519e-03 -3.6214e-04 1.3577e-05 5.1143e-07 3.5017e-07 2.1386e-05 2.6708e-05 1.9434e-05 5.6720e-07 5.3159e-07 2.9690e-05 3.4789e-02 -2.4202e-04 -6.6619e-01 1.3437e-01 2.7622e-03 1.8771e-03 1.9188e-01 12 9 9 12 1 1 91.22 20.31 0.90 0.03479 0.02456 8 4 1 4 0 2704.410 23.93 20.01 20.31 -3.92 21.1 972.13 48 -162 524 -305 -132 -289 1 -471 45 292 -277 -19 -394 -525 352 224 444 -133 362 -238 58 439 -38 -272 -598 -313 -19 104 15 104 29 148 95 -739 116 399 283 81 184 -2 -229 152 203 190 32 45 -248 -372 -128 352 -423 -9 121 -82 212 -14 -59 -225 -743 390 -524 206 96 218 360 71 -291 96 380 -44 429 -336 21 109 -405 -17 42 71 35 -245 92 134 90 388 227 378 47 515 632 -32 48 18 -399 -32 261 65 114 89 -52 124 96 -427 -303 -253 -17 -13 7 99 13 582 110 -103 475 152 -269 -286 -24 386 -246 -174 149 -148 91 92 -367 96 -256 103 -329 -428 235 233 79 -387 -134 -129 18 218 159 146 -80 67 -443 -2 21 -29 31 -90 -15 -256 93 -386 -143 -205 32 174 -126 -70 -252 79 -195 -130 41 75 -146 -321 -3 -44 8 67 -396 213 -163 28 10 -177 -130 -151 -199 346 546 559 279 183 162 -215 -21 105 -98 33 225 34 0 -278 50 1 -266 -357 172 56 35 183 -139 119 -12 -24 -191 -411 435 -214 306 -141 -182 249 74 -228 81 210 -283 -138 253 -106 -120 155 -255 310 514 626 111 15 -687 -74 -238 121 206 -21 96 152 -266 3 -238 261 -130 7 -15 -38 169 -80 447 -129 59 107 -194 -335 54 174 -101 48 -216 -56 -720 -224 171 -546 -142 319 -264 88 -404 -260 -127 -52 88 187 286 -212 406 37 30 -247 -68 53 68 6 -102 -15 370 294 -5 450 -220 -178 99 11 369 141 164 45 450 101 199 149 -18 -7 -30 58 90 94 -137 102 -354 111 228 -10 -27 73 113 154 -37 -47 157 -55 25 102 -157 -280 -100 27 104 71 77 275 -102 42 -25 4 9 -160 -66 -211 -212 135 -253 25 75 -140 137 43 35 96 -58 111 325 -42 161 15 -308 -252 131 -1 -231 -33 -133 6 58 136 201 105 -202 -169 63 -60 56 362 -156 1 -137 99 -59 -151 -99 14 -99 206 -65 -166 -56 -48 16 -204 -360 -191 -200 63 -165 -159 -241 -25 279 213 -195 93 220 -17 227 -177 177 177 241 176 -29 -26 40 8 -105 -133 35 -103 -184 108 114 86 19 61 64 -279 142 123 126 190 80 -86 25 56 105 -200 52 -277 218 -84 6 169 0 -170 124 -105 -33 -34 47 80 -74 40 16 -108 163 4 60 12 95 -70 34 116 98 -148 -101 -110 147 11 128 79 12 -105 135 19 -121 -81 -210 125 59 49 93 -116 -78 11 -115 241 -202 -36 75 83 277 -141 67 -79 -36 -149 -51 20 -132 143 41 -77 -182 -121 72 -101 -75 -98 14 4 93 -24 -125 9 -21 -48 64 58 120 15 -5 -127 1 -276 -74 126 -89 110 28 14 -124 219 227 72 -4 12 -55 86 18 69 62 -40 -187 228 -208 69 30 -101 313 -180 -77 -173 0 -295 28 185 -177 -12 -252 -338 227 146 290 -87 238 -158 38 284 -24 -174 -376 -197 -12 70 10 72 20 99 61 -470 73 257 190 56 128 -1 -158 102 135 127 22 30 -169 -249 -85 236 -292 -6 85 -58 149 -10 -41 -156 -514 274 -376 151 71 161 267 55 -224 74 293 -34 329 -253 16 80 -291 -12 29 49 24 -181 70 104 69 297 178 302 37 414 504 -26 39 15 -316 -25 207 51 92 71 -41 95 73 -334 -239 -208 -14 -11 5 80 11 463 87 -85 385 123 -223 -234 -19 308 -199 -143 123 -125 77 79 -316 81 -214 88 -275 -350 187 188 64 -309 -109 -107 15 181 132 122 -67 55 -367 -2 17 -25 26 -76 -13 -208 76 -312 -116 -166 26 146 -110 -61 -221 69 -172 -115 36 64 -123 -273 -2 -38 7 57 -324 168 -125 23 8 -153 -114 -130 -170 288 462 464 238 157 141 -187 -19 92 -84 28 188 29 0 -240 44 1 -229 -301 146 47 31 165 -126 106 -11 -20 -157 -335 349 -176 261 -124 -162 221 65 -200 71 181 -241 -117 208 -87 -101 132 -217 260 418 496 84 11 -509 -55 -177 89 152 -15 69 111 -208 2 -210 242 -123 7 -15 -36 153 -70 374 -110 52 98 -183 -323 52 167 -94 45 -189 -47 -585 -186 147 -492 -132 301 -251 84 -377 -243 -117 -48 83 177 274 -208 392 37 30 -245 -67 53 66 6 -98 -14 347 275 -5 432 -213 -171 93 9 319 123 147 42 424 97 189 142 -18 -7 -30 57 89 92 -130 96 -332 104 215 -9 -26 74 115 156 -37 -47 155 -55 26 104 -160 -287 -102 27 105 72 78 278 -104 42 -25 4 10 -165 -68 -214 -215 138 -259 26 78 -145 141 44 36 96 -57 109 317 -41 161 15 -311 -259 134 -1 -239 -34 -139 6 62 146 218 114 -217 -179 67 -63 60 389 -170 1 -148 107 -64 -164 -108 16 -107 225 -72 -183 -62 -54 18 -234 -416 -220 -230 72 -189 -183 -275 -28 318 244 -223 107 251 -20 258 -201 198 193 264 194 -32 -29 44 9 -120 -154 41 -121 -216 128 134 101 22 70 74 -324 165 144 148 225 95 -104 30 68 130 -248 64 -337 265 -104 7 211 0 -212 156 -132 -41 -43 59 98 -91 50 19 -135 202 6 77 15 121 -89 43 146 123 -187 -126 -139 187 13 165 102 16 -138 178 25 -158 -106 -274 163 77 65 122 -155 -104 15 -155 323 -273 -48 101 112 371 -189 90 -105 -48 -200 -69 27 -177 191 55 -102 -238 -161 95 -136 -101 -132 18 6 126 -33 -173 12 -29 -65 86 76 157 20 -6 -170 1 -373 -101 172 -123 150 38 19 -168 295 309 99 -6 16 -76 117 25 95 84 -55 -256 313 -282 93 SQ 20220219T011438.0Z 8085.051829 525 1 14.49 2 84.02 226.47 110.11 20.52 0.00 1 0.00 1 0 49 1.013e-03 8.479e-04 3.022e-04 2.664e-04 1.280020e+03 4.567114e+01 1.096886e+02 3.450951e+02 1.816547e+02 257.18 -2.00 20.00 -2.00 448.91 0.00e+00 2.732799e-04 3.134588e-05 1.481325e-05 1.676883e-05 1.079302e-04 257.18 -2.00 20.00 -2.00 457.47 0.00e+00 4.505301e-04 2.380518e-06 4.176645e-06 4.869400e-06 9.136821e-06 224.57 -2.00 3.02 -2.00 442.09 0.00e+00 2.555297e+06 3.513466e+04 2.384486e+04 2.338414e+05 1.420608e+05 244.16 -2.00 11.98 -2.00 459.02 0.00e+00 1.406326e+00 6.635981e-03 6.365595e-03 8.957744e-03 3.122063e-02 220.92 -2.00 4.56 -2.00 456.80 0.00e+00 -6.489355e-06 8.542294e-07 9.792973e-07 1.193062e-06 3.854755e-06 257.18 -2.00 20.00 -2.00 457.42 0.00e+00 8.595 0.018 397.00 473.00 4 2.3972e+00 2.9365e-04 2.1622e-02 4.1120e-04 1.0367e-03 -4.1013e-02 3.9190e-04 4.5165e-03 2.7137e-04 1.3569e-03 7.2625e-03 1.9281e-04 5.9474e-04 1.0095e-04 6.6797e-04 6.0610e-03 7.4374e-05 9.2912e-05 2.6732e-05 2.5006e-04 -4.5908e-03 3.7202e-05 5.8802e-05 1.7285e-05 1.2216e-04 2.9477e-04 -5.7720e-02 1.4698e-04 4.1176e-05 3.4645e-05 5.4340e-04 6.6496e-05 2.8332e-06 6.6750e-07 3.5734e-07 1.0551e-05 -7.3197e-05 4.0758e-06 8.6322e-07 5.4134e-07 1.4627e-05 1.4692e-02 -1.2551e-04 -5.4768e-01 2.7739e-02 3.3863e-03 1.8352e-03 9.3632e-02 12 1 1 12 1 1 83.70 20.25 1.02 0.01469 0.02237 199 139 1 4 0 71.570 23.83 20.00 20.25 -2.03 22.6 994.33 -107 -115 -169 -310 -362 -202 -203 -77 -105 -156 -223 -20 -151 -71 119 -39 62 90 -24 18 -61 16 -157 -337 -42 -45 -64 -11 -29 174 45 54 112 -67 -10 202 104 47 137 139 52 66 83 71 -29 75 106 -64 89 265 -23 115 292 116 63 159 66 148 123 159 47 118 28 107 107 113 50 39 159 -9 4 67 -178 -193 -258 -206 -231 -203 -142 -160 -96 42 41 115 89 131 143 68 265 177 133 265 129 95 70 104 -44 20 231 121 196 137 177 186 56 114 37 214 73 184 145 78 61 10 -12 -29 -165 -30 15 -110 -35 -190 -69 -81 -174 0 -30 -177 -127 5 -50 1 -86 -66 -81 -60 -63 -9 -126 -203 -56 -114 -211 -91 -12 -173 -57 -18 -194 50 34 32 108 -129 6 -17 -100 -87 -11 -131 -28 -81 14 -15 -104 -43 -187 -133 -118 -160 -105 107 -150 -48 -48 -187 -55 -134 14 -40 -97 99 -74 64 -31 -75 -79 -31 -116 84 -1 -50 50 -74 -96 -41 -68 -59 -41 -21 77 -61 49 129 14 186 86 -66 153 -86 -109 0 13 21 57 28 60 55 -102 115 61 32 64 178 94 191 195 190 195 137 184 17 -65 71 -1 -71 -46 -98 -62 71 -3 -63 -14 -65 -53 5 -1 90 108 89 131 93 -40 4 35 -155 -161 -214 -264 -221 -396 -382 -258 -310 -158 -37 -214 -124 -32 -137 -37 37 -84 69 83 14 97 50 -33 76 85 14 60 93 63 147 92 83 -16 30 -50 -126 33 113 103 124 175 162 205 205 196 176 230 158 165 159 189 -8 23 83 -49 44 147 76 67 58 -34 99 25 51 120 64 38 137 -42 -16 40 -19 -53 36 -13 -95 -34 5 -69 37 49 71 6 23 -28 -42 78 74 -18 -10 -44 -11 3 -13 -4 11 -42 -2 72 -64 -29 19 -18 -61 -51 -62 -109 -68 -84 21 9 2 -12 -36 -20 -42 3 -21 24 3 -32 -43 -31 -55 -85 -137 -169 -97 -85 -66 -6 -69 -71 -66 -82 -132 -132 -97 -64 -43 -62 -15 62 87 47 94 84 98 55 31 48 20 25 1 -19 -26 -9 -105 -96 -51 30 1 18 59 38 27 45 30 -31 -4 22 53 12 6 56 25 59 -33 3 9 30 6 26 34 48 65 41 44 70 49 38 16 50 50 16 26 -19 10 -35 16 -18 51 -22 -14 52 2 7 34 14 43 77 97 108 76 -13 -11 -2 -75 -78 -74 -24 2 -34 -4 -23 -26 -36 -10 -8 -36 -39 -7 14 34 -12 -70 -69 -46 -32 -16 11 -6 27 6 -62 -77 -35 -40 -78 -69 -87 -65 -80 -71 -37 -56 -6 -12 -41 -52 -11 21 3 -24 43 54 36 15 -24 13 38 62 27 18 49 136 70 55 47 18 -10 2 -31 7 -36 32 30 22 -11 23 -61 -65 -93 -174 -204 -116 -116 -45 -62 -93 -134 -12 -91 -43 72 -24 39 56 -15 12 -39 10 -93 -202 -25 -27 -39 -7 -18 111 28 35 67 -40 -6 123 65 31 91 91 33 42 51 44 -18 47 68 -40 56 169 -15 76 193 77 42 105 43 96 80 105 32 81 19 73 75 81 37 28 113 -6 3 47 -123 -134 -172 -136 -149 -132 -93 -113 -68 31 31 85 65 98 109 53 203 134 101 199 98 73 54 79 -33 15 171 88 142 101 134 142 45 91 29 161 56 140 112 60 48 8 -10 -23 -126 -23 12 -86 -28 -150 -56 -67 -143 0 -24 -141 -100 4 -39 1 -66 -52 -62 -47 -50 -7 -100 -161 -44 -89 -166 -72 -10 -140 -46 -14 -155 40 26 24 83 -102 5 -14 -82 -73 -9 -111 -24 -69 11 -12 -85 -35 -157 -111 -99 -133 -84 81 -112 -37 -39 -158 -46 -112 12 -32 -79 80 -62 53 -27 -65 -68 -26 -96 69 -1 -41 41 -63 -82 -35 -58 -48 -33 -17 64 -54 43 111 12 155 70 -52 120 -70 -92 0 11 18 49 24 52 47 -86 97 50 26 54 146 79 159 159 149 149 99 136 12 -48 52 -1 -52 -34 -72 -48 57 -2 -57 -13 -62 -51 5 -1 78 91 74 113 84 -37 3 32 -148 -151 -195 -229 -182 -324 -321 -223 -275 -145 -35 -203 -116 -30 -126 -33 34 -78 65 80 13 93 49 -33 75 82 14 59 89 61 138 87 79 -15 28 -48 -122 30 100 90 109 155 150 191 193 186 168 218 153 163 157 187 -8 22 79 -46 42 141 74 67 59 -34 100 25 50 119 65 39 142 -43 -16 40 -20 -55 37 -14 -98 -34 5 -69 37 50 74 6 24 -28 -43 80 76 -19 -11 -45 -11 3 -13 -4 11 -41 -2 73 -64 -30 19 -19 -65 -53 -65 -113 -73 -91 22 10 2 -14 -39 -21 -44 4 -22 26 3 -35 -46 -33 -60 -93 -150 -186 -108 -96 -74 -7 -78 -82 -76 -95 -154 -154 -113 -74 -50 -72 -18 70 99 54 109 98 113 63 35 55 22 28 1 -21 -29 -10 -121 -111 -60 35 1 21 71 46 32 54 35 -36 -5 25 63 14 8 69 31 74 -41 4 12 37 7 32 42 61 82 52 55 90 63 50 21 63 62 20 33 -23 12 -45 21 -23 65 -28 -19 67 3 9 44 18 56 100 127 142 99 -17 -15 -3 -102 -104 -99 -33 2 -46 -6 -31 -36 -50 -13 -11 -49 -54 -10 20 46 -17 -98 -95 -63 -44 -21 15 -8 38 9 -86 -104 -48 -54 -105 -94 -120 -90 -111 -98 -51 -79 -9 -17 -57 -74 -15 29 4 -32 58 74 50 22 -35 19 53 87 38 25 69 191 97 78 67 25 -14 3 -44 10 -51 47 43 31 -16 33 SQ 20220219T012446.8Z 8085.058874 528 1 49.30 2 84.81 228.84 109.76 23.09 0.00 1 0.00 1 0 49 1.549e-03 1.176e-03 1.957e-04 1.683e-04 1.317386e+03 2.899026e+01 1.008308e+02 3.450762e+02 2.779285e+02 257.18 -2.00 20.00 -2.00 449.38 0.00e+00 7.793594e-04 2.008457e-05 2.182714e-05 1.722265e-05 1.649636e-04 257.18 -2.00 20.00 -2.00 457.79 0.00e+00 4.985400e-04 1.509066e-06 4.750500e-06 4.870793e-06 1.399637e-05 224.59 -2.00 3.02 -2.00 442.98 0.00e+00 3.155538e+06 2.222226e+04 3.372888e+04 2.338346e+05 2.173186e+05 244.16 -2.00 11.98 -2.00 459.27 0.00e+00 1.483604e+00 4.144310e-03 6.423036e-03 8.886939e-03 4.773752e-02 220.92 -2.00 4.56 -2.00 457.12 0.00e+00 -1.027800e-06 5.332180e-07 1.144801e-06 1.194555e-06 5.894132e-06 257.18 -2.00 20.00 -2.00 457.67 0.00e+00 9.603 0.025 397.00 473.00 4 2.4684e+00 1.8720e-04 2.4435e-02 4.1286e-04 1.5846e-03 -4.5065e-02 2.5310e-04 5.1065e-03 2.7875e-04 2.0945e-03 5.2756e-03 1.2253e-04 6.7378e-04 1.0259e-04 1.0121e-03 6.4523e-03 4.8410e-05 1.1834e-04 2.7252e-05 3.8421e-04 -6.3629e-03 2.3974e-05 7.9682e-05 1.7576e-05 1.8644e-04 2.1806e-04 -6.4811e-02 8.9500e-05 4.4876e-05 3.4643e-05 8.1245e-04 1.3003e-04 1.8059e-06 7.4713e-07 3.5478e-07 1.6146e-05 -1.1927e-04 2.5956e-06 1.0224e-06 5.5175e-07 2.2422e-05 9.0436e-03 -7.1864e-05 -4.8221e-01 1.7533e-02 3.5792e-03 1.8537e-03 1.4222e-01 11 8 0 10 0 0 98.03 20.28 1.03 0.00904 0.02204 694 140 1 4 0 71.030 23.93 20.00 20.28 0.72 22.6 995.51 -223 -263 -237 -574 -547 -437 -415 -235 -179 -198 -341 -63 -156 -130 -18 -176 17 7 -5 -18 -19 -57 -266 -439 -330 -429 -210 -40 106 95 38 12 52 -274 -248 -21 -23 28 129 59 -34 108 105 14 -117 -2 29 -212 -15 132 -152 54 333 22 87 180 89 117 102 149 126 146 194 184 224 260 300 291 409 322 303 368 217 227 334 499 551 610 557 489 518 410 421 413 342 297 302 272 449 291 289 367 190 167 186 173 128 57 179 88 103 91 74 113 54 41 39 187 -17 68 39 -87 -45 -80 -204 -106 -274 -177 -46 -166 -80 -129 -156 -136 -186 -30 -58 -181 -58 -122 -154 -197 -202 -212 -241 -287 -110 -82 -176 -231 -176 -131 -308 -142 -30 -290 -176 -57 -299 -161 -220 -212 21 -195 -153 -34 -219 -111 -102 -113 -129 -119 -94 -153 -195 -87 -189 -166 -114 -222 -185 100 -253 -132 -119 -276 -110 -169 -115 -89 -130 57 -204 -33 -97 -170 -103 -106 -162 -37 -136 -258 -39 -142 -198 -74 -166 -85 -83 -102 49 -63 59 101 -4 107 -58 -138 9 -164 -271 -158 -122 -128 -132 -87 -118 -71 -216 -69 -50 -112 1 103 48 73 96 126 113 16 13 -79 -188 -85 -156 -183 -194 -111 -215 -17 -77 -47 68 -1 35 25 33 207 123 187 161 218 182 176 263 178 238 237 289 486 383 486 498 276 309 234 60 156 169 -19 62 63 -46 108 173 23 99 139 -15 85 131 -3 115 110 21 95 64 -54 -54 -57 -70 -172 10 98 -38 99 41 20 43 -3 7 99 40 -34 39 50 -1 -116 -87 47 -108 -44 99 20 68 79 14 99 97 59 167 76 81 127 -8 11 19 40 23 107 8 -46 -17 -60 -25 16 41 -5 16 -24 -41 -49 14 18 -47 -22 -18 -78 -9 -51 -65 -46 -35 -46 -9 -76 -46 -83 -124 -80 -114 -183 -105 -80 -68 -6 -17 -23 -24 -35 -65 -18 38 47 -23 8 -15 -31 -59 -78 -69 -113 -119 -130 -89 -33 -28 -26 -31 -21 -19 -70 -62 -26 -17 -29 -34 -41 76 117 75 95 128 92 53 40 52 46 52 -18 6 -6 -32 -81 -75 -49 -11 -33 -49 -9 26 33 7 41 14 -9 31 7 70 40 82 69 79 52 15 2 12 -30 17 -4 46 88 48 44 71 34 23 2 66 34 17 54 34 18 23 71 28 91 57 27 50 42 3 15 26 47 67 76 69 38 -3 -41 -50 -75 -68 -75 -33 -7 -19 4 -3 21 22 -5 -14 -31 -24 -6 -29 -15 -37 -70 -117 -91 -73 -31 -44 -47 -32 -70 -70 -91 -127 -98 -102 -120 -123 -139 -116 -91 -57 -39 -31 -45 -28 -42 -35 -10 6 16 47 57 48 10 -13 13 49 23 24 29 63 78 85 63 33 31 4 27 4 29 25 31 63 84 86 124 -120 -142 -124 -298 -283 -229 -226 -131 -101 -113 -195 -36 -89 -75 -10 -103 10 4 -3 -11 -11 -34 -152 -242 -187 -239 -122 -24 63 57 23 7 30 -158 -142 -13 -14 18 78 37 -21 65 63 9 -72 -1 17 -125 -9 78 -94 35 210 14 55 114 56 73 63 95 83 95 128 121 149 177 210 206 288 225 208 247 143 152 214 318 343 383 351 330 352 285 296 294 238 212 220 200 328 211 208 263 138 122 136 126 93 41 127 61 72 64 54 83 40 31 29 140 -13 50 29 -64 -34 -60 -152 -78 -201 -129 -34 -124 -61 -101 -121 -107 -147 -23 -45 -138 -45 -93 -116 -146 -149 -159 -185 -216 -83 -62 -134 -176 -133 -99 -233 -108 -23 -225 -139 -45 -237 -124 -164 -157 16 -149 -121 -26 -178 -92 -82 -92 -106 -97 -76 -121 -159 -71 -153 -137 -94 -178 -143 74 -183 -99 -93 -225 -92 -140 -92 -70 -102 45 -165 -27 -79 -141 -86 -87 -134 -30 -108 -210 -32 -115 -163 -61 -135 -70 -68 -81 41 -53 51 86 -3 86 -46 -106 7 -130 -222 -130 -102 -107 -111 -72 -97 -58 -181 -56 -40 -90 1 85 39 61 76 97 84 11 9 -57 -137 -62 -111 -132 -141 -80 -164 -14 -65 -42 62 -1 33 22 29 173 101 155 138 195 168 167 242 168 220 214 250 399 304 396 417 243 280 213 56 145 157 -17 55 57 -42 102 165 22 94 135 -15 83 125 -3 111 105 20 89 60 -51 -50 -54 -67 -165 10 87 -33 84 37 19 40 -3 7 94 38 -32 38 49 -1 -113 -83 44 -102 -41 92 19 68 79 14 100 95 59 164 77 82 130 -8 11 19 40 23 109 8 -47 -17 -59 -25 16 42 -5 16 -24 -42 -50 14 19 -48 -23 -19 -80 -9 -52 -65 -45 -34 -46 -9 -76 -47 -87 -129 -84 -119 -192 -111 -84 -74 -6 -18 -25 -27 -37 -69 -19 41 51 -25 9 -17 -34 -65 -86 -77 -126 -133 -144 -101 -38 -32 -29 -36 -24 -23 -82 -74 -31 -20 -34 -39 -48 89 137 86 110 149 109 62 46 59 51 59 -20 7 -6 -36 -94 -87 -58 -13 -40 -59 -11 31 40 9 48 17 -11 37 8 84 48 102 87 99 67 19 3 15 -38 21 -5 58 113 62 56 91 44 30 3 86 43 22 69 43 24 30 92 37 120 75 36 65 54 4 19 34 62 89 101 92 51 -4 -55 -68 -103 -93 -102 -44 -9 -25 6 -4 29 30 -6 -19 -44 -34 -9 -41 -21 -52 -99 -164 -127 -101 -43 -61 -66 -44 -99 -98 -128 -177 -137 -142 -168 -175 -199 -166 -130 -83 -57 -45 -67 -41 -60 -50 -13 9 22 66 79 69 14 -19 18 72 34 34 41 89 112 124 91 48 44 6 39 6 41 36 46 91 121 124 177