File name: Pandora230s1_Gongju-KNU_20260620_L2Fit_fwvt1c2d20221031p1-8.txt File generation date: 20260624T075749.2Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c2p1-8 Local principal investigator: Hyunkee Hong Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 230 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora230_OF_v4d20220711.txt Instrument calibration file used: Pandora230s1_CF_v2d20221031.txt Level 1 file used: Pandora230s1_Gongju-KNU_20260620_L1_smca1c2d20221031p1-8.txt Full location name: Kongju National University, Gongju Campus Short location name: Gongju-KNU Country of location: Korea, Republic of Location latitude [deg]: 36.4710 Location longitude [deg]: 127.1450 Location altitude [m]: 64 Local noon date: 20260620 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: OoB session based on session 1 First and last pixel inside fitting window: 1614 1763 Nominal wavelengths inside fitting window [nm]: 492.0443 492.1657 492.2870 492.4084 492.5297 492.6510 492.7723 492.8935 493.0148 493.1360 493.2572 493.3784 493.4996 493.6207 493.7419 493.8630 493.9841 494.1052 494.2263 494.3473 494.4683 494.5894 494.7104 494.8314 494.9523 495.0733 495.1942 495.3152 495.4361 495.5569 495.6778 495.7987 495.9195 496.0403 496.1611 496.2819 496.4027 496.5234 496.6442 496.7649 496.8856 497.0063 497.1269 497.2476 497.3682 497.4888 497.6094 497.7300 497.8506 497.9711 498.0917 498.2122 498.3327 498.4532 498.5736 498.6941 498.8145 498.9349 499.0553 499.1757 499.2960 499.4164 499.5367 499.6570 499.7773 499.8976 500.0178 500.1381 500.2583 500.3785 500.4987 500.6189 500.7390 500.8592 500.9793 501.0994 501.2195 501.3396 501.4596 501.5797 501.6997 501.8197 501.9397 502.0596 502.1796 502.2995 502.4194 502.5393 502.6592 502.7791 502.8989 503.0188 503.1386 503.2584 503.3782 503.4979 503.6177 503.7374 503.8571 503.9768 504.0965 504.2161 504.3358 504.4554 504.5750 504.6946 504.8142 504.9337 505.0533 505.1728 505.2923 505.4118 505.5313 505.6507 505.7702 505.8896 506.0090 506.1284 506.2477 506.3671 506.4864 506.6057 506.7250 506.8443 506.9636 507.0828 507.2021 507.3213 507.4405 507.5597 507.6788 507.7980 507.9171 508.0362 508.1553 508.2744 508.3934 508.5125 508.6315 508.7505 508.8695 508.9884 509.1074 509.2263 509.3453 509.4642 509.5830 509.7019 509.8208 509.9396 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Column 102: Humidity inside spectrometer box [%], -9=no humidity signal Column 103: Temperature inside spectrometer box [°C], 999=no temperature signal Column 104: Pressure inside spectrometer box [hPa], -9=no pressure signal Columns 105-254: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 255-404: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20260620T032718.7Z 9667.143967 252 1 48.09 2 13.10 174.26 71.06 94.24 0.00 1 0.00 1 0 148 4.907e-02 4.739e-02 1.606e-03 1.595e-03 1.556598e+03 9.380468e+01 3.906404e+02 -6.000000e+00 2.850795e+03 289.34 -2.00 20.00 -2.00 505.12 0.00e+00 6.716450e-03 4.424018e-05 5.814913e-04 -6.000000e+00 1.409740e-03 289.34 -2.00 20.00 -2.00 500.45 0.00e+00 -6.294904e+00 3.075869e-02 9.815261e-02 -6.000000e+00 9.815614e-01 232.72 -2.00 3.42 -2.00 501.99 0.00e+00 1.027 0.000 489.00 513.00 1 8.4330e+00 2.3609e-03 1.5957e-02 -6.0000e+00 7.5533e-02 1.6317e-01 6.0103e-04 1.3795e-03 -6.0000e+00 1.9382e-02 5.3102e-04 6.9313e-02 1.7372e-04 2.2946e-04 -6.0000e+00 5.3252e-03 9.6668e-03 1.1941e-04 12 8 8 10 0 0 99.72 24.33 0.39 0.00967 0.49045 13 3 1 2 0 3698.990 20.01 24.33 29.80 26.73 26.94 6.3 1002.92 6.9 28.58 991.02 -848 993 1384 1513 993 574 107 -714 -1002 -1774 -1084 -440 -90 58 173 607 2374 4404 5735 6807 7076 5706 4599 1610 -1844 -6354 -7265 -6692 -4980 -2303 -786 -1781 -4025 -4200 -3593 -1150 1811 5638 9632 12208 12551 9955 5102 32 -3384 -4731 -5654 -5993 -6527 -6016 -4609 -3214 -1699 -1187 -1022 -1861 -1874 -191 1382 3307 4177 3444 1252 -286 -1434 -2440 -2283 -1543 -251 2046 4651 5130 4350 2112 -807 -3035 -3741 -3791 -4456 -4011 -4155 -3888 -3804 -3628 -1754 1499 5119 6865 7488 5569 3261 1204 176 -968 -2654 -3824 -4868 -4993 -3797 -2478 -3151 -4100 -5511 -6736 -5549 -2825 1272 5239 7314 9005 9105 8884 7780 6857 4922 2542 1188 503 1814 3391 4715 5155 4410 2654 1273 558 -2119 -4349 -6307 -7822 -8092 -7413 -5965 -5743 -5969 -6766 -6788 -6524 -5417 -2743 16 3805 5988 7286 7149 8700 10160 9648 7052 1333 -902 1055 1483 1622 1062 607 111 -735 -1014 -1780 -1072 -433 -89 59 176 620 2386 4331 5564 6550 6817 5571 4507 1598 -1843 -6453 -7337 -6743 -5029 -2329 -800 -1841 -4226 -4370 -3682 -1146 1762 5344 8904 11159 11550 9432 5051 33 -3538 -4894 -5758 -6020 -6575 -6117 -4751 -3362 -1788 -1256 -1083 -1993 -2017 -203 1454 3407 4231 3470 1272 -291 -1460 -2485 -2315 -1562 -254 2039 4531 4938 4164 2042 -799 -3068 -3829 -3910 -4659 -4207 -4400 -4123 -4031 -3835 -1821 1517 5061 6784 7457 5676 3377 1255 181 -984 -2679 -3846 -4944 -5149 -3963 -2609 -3144 -4106 -5528 -6769 -5508 -2959 1302 5249 7286 8912 9055 8880 7854 6931 4998 2597 1210 510 1809 3336 4579 4977 4276 2605 1259 551 -2113 -4343 -6306 -7845 -8125 -7465 -5999 -5821 -5694 -6519 -6535 -6257 -5132 -2700 15 3401 5099 5972 5786 6938 8073 7811 5905 1179 SQ 20260620T050220.1Z 9667.209955 306 1 48.43 2 23.24 242.09 53.13 110.60 0.00 1 0.00 1 0 127 4.901e-02 4.736e-02 1.238e-03 1.230e-03 1.602192e+03 7.235691e+01 3.722333e+02 -6.000000e+00 2.847410e+03 289.35 -2.00 20.00 -2.00 505.12 0.00e+00 7.004504e-03 3.406057e-05 5.967915e-04 -6.000000e+00 1.408081e-03 289.35 -2.00 20.00 -2.00 500.42 0.00e+00 -6.240697e+00 2.375325e-02 9.775171e-02 -6.000000e+00 9.801392e-01 232.72 -2.00 3.42 -2.00 501.96 0.00e+00 1.088 0.000 489.00 513.00 1 8.0202e+00 1.8231e-03 1.6217e-02 -6.0000e+00 7.5428e-02 1.6630e-01 4.6470e-04 1.3232e-03 -6.0000e+00 1.9349e-02 7.8883e-04 6.8228e-02 1.3324e-04 2.3603e-04 -6.0000e+00 5.3184e-03 1.0087e-02 1.3572e-04 12 8 8 10 0 0 99.45 24.47 0.30 0.01009 0.48334 16 4 1 2 0 3026.790 20.00 24.47 30.67 26.83 27.05 6.2 1004.92 6.8 29.48 991.74 -444 1330 1769 1776 1291 939 445 -106 -822 -1295 -941 -285 -131 -38 310 990 2661 4642 5928 6845 6770 5878 4582 2046 -1878 -5882 -7505 -6956 -4805 -2562 -995 -2145 -4180 -4703 -4242 -1911 1234 4991 8782 11693 12144 9766 5083 -153 -3141 -4710 -5636 -5650 -6185 -6179 -4883 -3269 -2113 -1348 -1306 -1866 -1639 -149 1617 3379 4043 3491 1414 -201 -1508 -2495 -2434 -1661 -489 1977 4331 4976 4426 2382 -611 -3080 -3775 -4279 -4566 -4242 -4107 -4066 -4101 -3545 -2204 1381 5020 6752 6938 5381 3315 1454 264 -1288 -2825 -3917 -4869 -5426 -3312 -2847 -3315 -4102 -5741 -6510 -5755 -2965 1345 4854 7412 9005 9151 8929 7865 7069 4920 2708 1230 876 2025 3552 4878 5230 4320 2889 1600 342 -1871 -4240 -6298 -7567 -7982 -6940 -5820 -5851 -6001 -6344 -7209 -6544 -5112 -3070 45 3773 6485 7032 7535 9103 10117 9654 7379 1120 -472 1415 1897 1911 1384 994 464 -109 -835 -1300 -933 -281 -130 -38 317 1012 2675 4569 5758 6604 6563 5749 4508 2031 -1886 -5971 -7622 -7046 -4853 -2602 -1017 -2232 -4408 -4933 -4389 -1926 1211 4774 8210 10775 11258 9305 5052 -158 -3291 -4894 -5765 -5680 -6231 -6312 -5059 -3430 -2239 -1434 -1394 -2006 -1765 -159 1702 3491 4116 3529 1440 -206 -1542 -2550 -2478 -1687 -495 1975 4241 4808 4243 2302 -604 -3118 -3868 -4438 -4781 -4460 -4347 -4320 -4359 -3741 -2298 1398 4960 6669 6940 5491 3431 1511 272 -1314 -2856 -3939 -4935 -5605 -3428 -2812 -3318 -4116 -5784 -6538 -5734 -2907 1371 4868 7358 8892 9078 8904 7920 7120 4990 2758 1251 883 2012 3482 4721 5037 4186 2825 1576 338 -1859 -4224 -6288 -7557 -7988 -6937 -5828 -5549 -5735 -6097 -6981 -6287 -4835 -3022 42 3365 5481 5762 6055 7202 8009 7785 6136 989 SQ 20260620T051122.1Z 9667.216228 310 1 47.58 2 24.87 245.24 51.50 112.45 0.00 1 0.00 1 0 155 4.895e-02 4.759e-02 1.524e-03 1.514e-03 1.941254e+03 8.989504e+01 4.095153e+02 -6.000000e+00 2.843955e+03 289.35 -2.00 20.00 -2.00 505.13 0.00e+00 6.431910e-03 4.171996e-05 5.794273e-04 -6.000000e+00 1.406350e-03 289.35 -2.00 20.00 -2.00 500.47 0.00e+00 -6.406067e+00 2.890563e-02 9.978444e-02 -6.000000e+00 9.792239e-01 232.72 -2.00 3.42 -2.00 502.01 0.00e+00 1.102 0.000 489.00 513.00 1 8.3003e+00 2.2103e-03 1.6055e-02 -6.0000e+00 7.5353e-02 1.6665e-01 5.6596e-04 1.4302e-03 -6.0000e+00 1.9337e-02 6.0669e-04 7.0444e-02 1.6468e-04 2.3460e-04 -6.0000e+00 5.3124e-03 1.1372e-02 1.0536e-04 12 8 8 10 0 0 99.59 24.48 0.33 0.01137 0.50000 18 5 1 2 0 2642.870 20.00 24.48 30.75 26.83 27.05 6.3 1005.62 6.8 29.49 991.91 -710 924 1529 1326 989 62 -120 -568 -1279 -1733 -1204 -520 -587 -54 241 1002 2598 4668 6026 6778 6829 5555 4420 1705 -2414 -6230 -7538 -6687 -4876 -1975 -789 -1895 -3889 -4473 -3360 -1318 1515 5628 9518 11974 12398 9801 4791 -371 -3432 -4798 -5789 -6051 -6286 -6266 -4621 -3331 -1742 -1338 -1344 -2087 -1864 -474 1286 3105 3968 3405 1319 -289 -1640 -2766 -2219 -1593 -323 2396 4443 5006 4298 2329 -558 -2740 -3818 -3833 -4330 -4021 -3788 -3829 -3966 -3305 -1648 1755 5083 7119 7230 5546 3263 1323 -212 -1255 -2993 -3964 -4773 -5061 -3461 -2416 -2658 -3667 -5103 -6255 -5182 -2359 1648 5179 7550 9184 9375 8930 7943 6803 4793 2664 1034 602 1645 3655 4907 5235 4341 2714 1474 299 -2072 -4369 -6386 -7668 -7690 -7272 -5529 -5425 -5944 -6469 -6842 -6401 -4969 -2884 15 3723 6147 7062 7435 9063 10574 10048 7535 1370 -751 980 1630 1419 1053 65 -125 -581 -1292 -1731 -1187 -511 -583 -54 245 1017 2596 4564 5810 6503 6572 5409 4319 1682 -2412 -6285 -7602 -6716 -4908 -1986 -801 -1953 -4059 -4645 -3419 -1311 1473 5314 9447 11761 12244 9248 4727 -380 -3564 -4929 -5860 -6042 -6280 -6357 -4742 -3471 -1823 -1409 -1421 -2226 -1993 -503 1345 3183 3999 3407 1329 -292 -1662 -2808 -2235 -1604 -324 2366 4311 4792 4088 2232 -547 -2746 -3890 -3934 -4498 -4197 -3978 -4039 -4190 -3465 -1703 1764 5006 6986 7180 5616 3353 1364 -217 -1267 -3003 -3959 -4810 -5194 -3585 -2532 -2815 -3899 -5436 -6672 -5470 -2451 1674 5168 7464 9017 9238 8862 7951 6833 4838 2699 1047 605 1632 3559 4720 5011 4178 2640 1443 294 -2045 -4322 -6333 -7614 -7634 -7262 -5497 -5441 -6028 -6608 -7010 -6522 -4984 -2820 14 3301 5180 5753 5956 7152 8312 8048 6232 1202 SQ 20260620T060036.9Z 9667.250427 337 1 7.83 2 34.27 258.08 43.10 124.07 0.00 1 0.00 1 0 134 4.893e-02 4.796e-02 3.483e-03 3.472e-03 1.863941e+03 2.087787e+02 4.165247e+02 -6.000000e+00 2.841944e+03 289.35 -2.00 20.00 -2.00 505.16 0.00e+00 6.840488e-03 9.602960e-05 6.145154e-04 -6.000000e+00 1.406010e-03 289.35 -2.00 20.00 -2.00 500.41 0.00e+00 -6.484803e+00 6.660057e-02 1.070859e-01 -6.000000e+00 9.804119e-01 232.72 -2.00 3.42 -2.00 501.97 0.00e+00 1.209 0.000 489.00 513.00 1 7.9440e+00 5.1192e-03 1.6994e-02 -6.0000e+00 7.5419e-02 1.7191e-01 1.2861e-03 1.5396e-03 -6.0000e+00 1.9400e-02 8.5384e-04 7.3633e-02 3.7803e-04 2.4251e-04 -6.0000e+00 5.3111e-03 2.3581e-02 -1.0659e-04 12 13 9 12 1 1 999.00 24.49 0.25 0.02358 0.53433 1 3 1 2 0 3910.980 20.00 24.49 31.01 26.83 27.05 6.3 1007.17 6.8 29.55 992.42 -18 1688 1818 1955 1203 387 168 62 -690 -1259 -1166 -244 -148 362 236 1033 2212 4493 6383 6645 6873 5559 3781 1915 -2514 -6267 -7778 -6589 -5231 -1874 -810 -2087 -4163 -4926 -4316 -2448 1405 4807 9109 11372 11751 9228 4653 -563 -3066 -4682 -6160 -5453 -6068 -6117 -4326 -3083 -2246 -1584 -1785 -1958 -2046 -264 1571 2872 3838 3233 1813 -359 -1695 -2882 -2800 -1598 -778 1501 4130 5219 4084 2370 -600 -2586 -3262 -4016 -4742 -3888 -3455 -4413 -4148 -3606 -1961 1453 5076 6943 7225 5765 3458 1002 41 -1245 -2730 -4567 -4564 -4916 -4147 -2128 -2879 -4321 -5334 -6317 -5556 -2452 1750 5081 7748 9098 10003 9078 7681 7128 4928 2812 1669 662 1309 3654 4881 5206 4307 2412 2051 530 -2568 -4706 -6480 -8015 -8395 -7589 -5588 -6281 -5909 -6680 -7440 -6506 -5456 -3117 -182 3322 5919 6079 6859 8395 10164 9919 7181 1175 -19 1755 1908 2051 1260 402 178 64 -708 -1279 -1175 -244 -150 370 245 1070 2264 4490 6258 6516 6749 5525 3794 1923 -2564 -6450 -8022 -6749 -5395 -1923 -839 -2198 -4284 -5053 -4524 -2513 1396 4675 8943 11073 11510 8950 4698 -570 -3125 -4734 -6395 -5532 -6187 -6340 -4369 -3163 -2332 -1650 -1869 -2058 -2163 -276 1617 2911 3962 3315 1860 -358 -1694 -2888 -2798 -1587 -774 1530 4109 5095 3978 2321 -602 -2550 -3257 -4069 -4872 -3992 -3560 -4608 -4319 -3730 -1999 1442 5101 6966 7063 5734 3492 1020 41 -1237 -2690 -4517 -4517 -4956 -4252 -2185 -3001 -4382 -5397 -6391 -5781 -2505 1745 4989 7517 8793 9634 8848 7581 7015 4883 2795 1651 653 1281 3499 4789 5082 4228 2314 1963 510 -2504 -4590 -6320 -7845 -8244 -7467 -5459 -6237 -5880 -6709 -7521 -6506 -5391 -2994 -174 3005 5272 5274 6062 7316 8801 8726 6287 1049 SQ 20260620T065252.2Z 9667.286715 364 1 47.77 2 44.69 267.47 35.62 140.38 0.00 1 0.00 1 0 127 4.876e-02 4.708e-02 1.969e-03 1.950e-03 1.813629e+03 1.150940e+02 3.514074e+02 -6.000000e+00 2.832674e+03 289.35 -2.00 20.00 -2.00 505.00 0.00e+00 6.991000e-03 5.359498e-05 6.023507e-04 -6.000000e+00 1.400858e-03 289.35 -2.00 20.00 -2.00 500.24 0.00e+00 -6.416277e+00 3.784299e-02 1.025910e-01 -6.000000e+00 9.758325e-01 232.72 -2.00 3.42 -2.00 501.76 0.00e+00 1.405 0.000 489.00 513.00 1 7.9450e+00 2.9044e-03 1.6491e-02 -6.0000e+00 7.5084e-02 1.7325e-01 7.4408e-04 1.4095e-03 -6.0000e+00 1.9281e-02 8.2361e-04 6.9788e-02 2.1071e-04 2.3892e-04 -6.0000e+00 5.2919e-03 1.1895e-02 6.1259e-05 12 8 8 10 0 0 99.98 24.60 0.17 0.01189 0.49597 98 25 1 2 0 487.380 20.00 24.60 31.62 26.94 27.15 6.2 1007.54 6.7 30.28 993.21 -364 1558 1854 1812 1307 532 444 115 -602 -1359 -466 -378 -166 339 287 943 2600 4874 6011 7000 6628 5925 4686 1982 -1976 -6163 -7545 -6888 -5078 -2451 -1152 -1972 -4104 -4627 -4166 -2094 808 4912 8887 11531 11693 9297 4662 -427 -3076 -4635 -5597 -5722 -6374 -6096 -5089 -3273 -1821 -1342 -1157 -1796 -1773 -198 1739 3180 4029 3642 1363 -101 -1687 -2501 -2346 -1543 -596 1787 4140 4385 4382 2381 -556 -3047 -3320 -4105 -3610 -4021 -4266 -3897 -4211 -3824 -1929 1450 4684 6707 7166 5849 3303 1707 237 -1104 -2740 -4150 -5123 -4880 -4076 -2983 -3110 -4043 -5364 -6344 -5624 -2651 1327 5010 7533 9051 9150 8839 8183 6858 4880 2349 1252 990 2142 3532 4665 5343 4308 2855 1538 432 -1848 -4366 -6336 -7808 -8060 -7175 -6036 -5904 -5779 -6789 -7120 -6818 -5388 -3338 -184 3809 6203 7024 7799 8655 10158 9418 6699 1045 -392 1679 2016 1977 1422 574 469 119 -618 -1383 -467 -379 -168 346 297 978 2652 4852 5913 6835 6522 5870 4667 1994 -2012 -6354 -7767 -7066 -5213 -2520 -1195 -2074 -4381 -4912 -4362 -2141 807 4765 8408 10782 11031 9015 4714 -449 -3262 -4873 -5796 -5831 -6518 -6305 -5355 -3480 -1950 -1446 -1249 -1955 -1937 -215 1854 3336 4157 3726 1407 -105 -1751 -2591 -2420 -1587 -613 1814 4118 4321 4261 2333 -557 -3127 -3434 -4310 -3797 -4279 -4587 -4192 -4544 -4105 -2034 1487 4710 6723 7252 6022 3464 1792 247 -1138 -2802 -4236 -5275 -5080 -4310 -3190 -3360 -4020 -5338 -6309 -5550 -2569 1372 5086 7571 9053 9198 8939 7629 6430 4598 2230 1182 925 1973 3214 4199 5203 3874 2591 1406 395 -1702 -4039 -5868 -7247 -7485 -6665 -5616 -5541 -5449 -6479 -6811 -6492 -5051 -3052 -161 3145 5311 5816 6315 6949 8120 7690 5665 856