File name: Pandora71s1_GreenbeltMD_20220907_L2Fit_fsus1c1d20220202p1-8.txt File generation date: 20260322T084812.9Z Data description: Level 2 spectral fitting results file Data file version: fsus1c1p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 71 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora71_OF_v7d20201007.txt Instrument calibration file used: Pandora71s1_CF_v1d20220202.txt Level 1 file used: Pandora71s1_GreenbeltMD_20220907_L1_smca1c1d20220202p1-8.txt.bz2 Full location name: Goddard Space Flight Center Short location name: GreenbeltMD Country of location: USA Location latitude [deg]: 38.9926 Location longitude [deg]: -76.8396 Location altitude [m]: 90 Local noon date: 20220907 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are blind pixel subtraction, dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 239 384 Nominal wavelengths inside fitting window [nm]: 306.0587 306.1993 306.3399 306.4804 306.6209 306.7615 306.9020 307.0425 307.1830 307.3234 307.4639 307.6043 307.7448 307.8852 308.0256 308.1660 308.3064 308.4468 308.5872 308.7276 308.8679 309.0083 309.1486 309.2889 309.4292 309.5695 309.7098 309.8501 309.9903 310.1306 310.2708 310.4110 310.5512 310.6914 310.8316 310.9718 311.1120 311.2521 311.3923 311.5324 311.6725 311.8126 311.9527 312.0928 312.2329 312.3730 312.5130 312.6531 312.7931 312.9331 313.0731 313.2131 313.3531 313.4931 313.6330 313.7730 313.9129 314.0529 314.1928 314.3327 314.4726 314.6124 314.7523 314.8922 315.0320 315.1718 315.3117 315.4515 315.5913 315.7311 315.8708 316.0106 316.1503 316.2901 316.4298 316.5695 316.7092 316.8489 316.9886 317.1283 317.2679 317.4076 317.5472 317.6868 317.8264 317.9660 318.1056 318.2452 318.3848 318.5243 318.6639 318.8034 318.9429 319.0824 319.2219 319.3614 319.5009 319.6403 319.7798 319.9192 320.0586 320.1980 320.3374 320.4768 320.6162 320.7555 320.8949 321.0342 321.1736 321.3129 321.4522 321.5915 321.7307 321.8700 322.0093 322.1485 322.2877 322.4269 322.5662 322.7054 322.8445 322.9837 323.1229 323.2620 323.4011 323.5403 323.6794 323.8185 323.9576 324.0966 324.2357 324.3747 324.5138 324.6528 324.7918 324.9308 325.0698 325.2088 325.3478 325.4867 325.6257 325.7646 325.9035 326.0424 326.1813 326.3202 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Spectrometer control temperature [°C], 999=no temperature signal Column 155: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 156: Temperature in head sensor [°C], 999=no temperature signal Column 157: Temperature at electronics board 1 [°C], 999=no temperature signal Column 158: Temperature at electronics board 2 [°C], 999=no temperature signal Column 159: Humidity in head sensor [%], -9=no humidity signal Column 160: Pressure in head sensor [hPa], -9=no pressure signal Columns 161-306: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 307-452: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220907T125319.0Z 8285.537026 159 1 28.50 2 65.42 102.92 153.46 296.76 0.00 1 0.00 1 7 261 8.875e-02 6.816e-02 1.546e-02 5.295e-03 -6.372398e-05 1.848072e-06 8.483173e-07 4.991784e-07 3.940765e-05 229.88 -2.00 3.47 -2.00 322.22 0.00e+00 3.423488e-02 6.930370e-04 2.115173e-04 5.347983e-06 1.029808e-02 289.32 -2.00 20.00 -2.00 322.09 0.00e+00 1.892261e-02 9.853208e-04 2.223080e-04 3.323202e-05 1.838627e-02 289.32 -2.00 20.00 -2.00 321.91 0.00e+00 2.083458e-02 1.486666e-03 3.517868e-03 1.142472e-05 1.911750e-02 289.32 -2.00 20.00 -2.00 322.00 0.00e+00 -8.012174e-02 7.667675e-03 1.003326e-02 1.110093e-02 1.011650e-01 1914.47 290.35 0.00 391.28 3820.63 319.46 0.00e+00 -1.462596e-03 4.344767e-04 2.264477e-04 2.280296e-06 2.413808e-03 289.32 -2.00 20.00 -2.00 317.94 0.00e+00 2.388 0.000 303.00 329.40 4 5.4232e+00 1.8249e-02 3.1165e-02 2.6336e-03 3.2521e-01 -1.4490e+00 2.7938e-02 4.4446e-02 6.9148e-04 3.4504e-01 8.1085e-01 1.5034e-02 1.5762e-02 2.5249e-04 1.8785e-01 -2.9498e-01 7.9632e-03 4.7416e-03 7.7236e-05 7.4103e-02 -4.1526e-04 4.9412e-03 3.6860e-03 8.3415e-05 5.5019e-02 7.2685e-04 -2.2532e-02 3.6800e-03 3.3018e-03 2.2081e-05 1.7785e-02 1.7253e-02 1.4374e-04 1.0198e-04 5.8314e-07 2.1093e-03 1.0503e-01 0.0000e+00 2.8758e+01 3.0940e-01 3.9767e-02 9.6328e-04 4.9071e+00 12 15 13 12 1 1 99.93 24.74 2.90 0.10503 0.23667 7 2 1 8 0 2842.330 20.00 24.74 27.50 28.75 30.50 15.2 1050.42 -526 919 -17172 -27035 -9331 985 1601 12699 -4851 6296 -11 8749 -4635 -10985 -12430 -1733 -10730 8433 27129 6949 -5638 -11258 8897 -21410 2476 3784 -14798 -12206 -1620 -11726 -8115 832 2404 2168 14365 8548 9881 16228 10496 6147 1720 -7238 -274 972 -7069 5510 2528 5007 5710 6717 -2100 -3466 -3055 -454 284 15225 15762 -11703 2912 -17109 -15145 -2565 -3810 4076 924 8186 11564 5032 9 -18920 -12295 -2363 -1580 4250 28 -13391 -2470 30 2020 -1966 6697 10394 2191 -16 -14303 -13738 -7253 -5379 -4017 12367 18302 11909 7180 6118 -3022 -6718 3628 -14082 -4625 -3993 -2066 -3052 3523 11432 10430 9222 4469 -8075 -1751 -9205 -2879 -2208 3081 -97 14022 4566 -2222 5228 -5145 -2731 2384 -390 2984 -2460 1060 -12625 -15 -3194 -5037 1701 9523 -2661 -1483 3636 3497 -2336 -8551 2557 -3204 2128 4422 -2671 7630 -135 -4314 900000 -46 92 -1773 -3510 -1333 139 267 2133 -880 1209 -2 1618 -906 -2159 -2572 -354 -2298 1668 4859 1308 -1084 -2504 1991 -5171 597 926 -3608 -3421 -529 -4526 -3207 348 1027 954 6013 3739 4251 6860 4468 2637 779 -3450 -143 522 -3789 2940 1369 2691 3166 3577 -1143 -1997 -1933 -310 197 10115 9670 -7320 1792 -11980 -10991 -1918 -2967 2963 650 5675 7308 3042 6 -12927 -8949 -1901 -1373 3589 24 -12780 -2432 31 2079 -1988 6345 9579 1924 -14 -12454 -12382 -7198 -5833 -4432 13893 20752 12424 7006 5923 -3165 -7248 4030 -16429 -5658 -5132 -2654 -4060 4595 14867 12714 10548 5367 -9468 -2164 -12088 -3942 -2919 4025 -123 16688 5531 -2608 5926 -6209 -3382 3122 -534 4169 -3537 1509 -19051 -23 -4971 -8044 2707 14419 -3936 -2262 5590 5347 -3890 -14607 4604 -6214 4071 8599 -5265 15356 -259 -8531 900000 SS 20220907T130126.9Z 8285.542672 164 1 54.16 2 63.89 104.38 154.77 299.47 0.00 1 0.00 1 7 262 9.040e-02 6.578e-02 1.504e-02 4.344e-03 -6.590506e-05 1.527425e-06 1.029969e-06 4.993038e-07 4.033344e-05 229.88 -2.00 3.47 -2.00 322.77 0.00e+00 3.920590e-02 5.896266e-04 3.720332e-04 4.950900e-06 1.056322e-02 289.32 -2.00 20.00 -2.00 322.82 0.00e+00 2.179170e-02 8.379103e-04 1.403406e-04 3.318753e-05 1.863517e-02 289.32 -2.00 20.00 -2.00 322.32 0.00e+00 1.386801e-02 1.330182e-03 3.703997e-03 1.171913e-05 1.949170e-02 289.32 -2.00 20.00 -2.00 322.50 0.00e+00 -6.444779e-02 6.770841e-03 1.179859e-02 1.109765e-02 1.029450e-01 2254.33 464.98 0.00 725.92 7055.26 320.19 0.00e+00 -1.258291e-03 4.130173e-04 3.080340e-04 2.470501e-06 2.539029e-03 289.32 -2.00 20.00 -2.00 318.55 0.00e+00 2.259 0.000 303.00 329.40 4 5.3312e+00 1.5430e-02 2.8143e-02 2.6384e-03 3.3105e-01 -1.3122e+00 2.4867e-02 4.9680e-02 7.0962e-04 3.5075e-01 7.4997e-01 1.3394e-02 1.8370e-02 2.6848e-04 1.9159e-01 -2.6442e-01 6.9620e-03 6.1580e-03 9.0560e-05 7.7072e-02 -1.4140e-02 4.1842e-03 3.6747e-03 8.8982e-05 5.5594e-02 8.9418e-04 -8.3981e-03 3.7523e-03 4.6752e-03 3.0891e-05 2.4117e-02 1.6347e-02 1.2489e-04 1.2956e-04 5.8401e-07 2.2282e-03 1.0292e-01 0.0000e+00 2.7721e+01 2.6267e-01 3.8119e-02 8.8829e-04 5.0744e+00 12 14 12 10 0 0 99.97 24.76 2.69 0.10292 0.22764 84 9 1 8 0 644.329 20.01 24.76 27.69 28.75 30.50 15.2 1052.04 -23326 -6606 -20458 -15695 -11789 -13806 1674 12191 3431 9326 -231 2959 -2592 -11557 -12830 1918 -11209 5488 18651 9601 -10705 -11830 4088 -23957 117 4910 -16714 -14103 -3714 -11108 -7570 2916 5103 3905 12081 9999 6914 17032 11704 5079 4546 -6977 1420 1141 -2415 7417 2958 2286 7635 7229 -3123 -3657 -3102 866 -1117 13614 14991 -9661 475 -17334 -15867 -4644 -2211 4677 1479 8770 11982 5637 742 -18363 -12776 -667 -2727 3208 -584 -12824 -3927 -1892 1049 -2338 6794 9855 3727 269 -14108 -12830 -7223 -4674 -4120 12924 20143 12571 7828 6377 -4709 -7839 4449 -13445 -4176 -3936 -2477 -3250 4119 11801 10861 9092 5808 -7639 -1544 -9966 -2568 -3192 4125 -297 13563 4695 -1766 5330 -6246 -3594 2161 -596 3467 -2717 573 -12495 -799 -3622 -5460 1971 9642 -2268 -1137 3709 2540 -2561 -7638 2678 -3361 1985 4505 -2526 7038 -244 -3895 900000 -1881 -546 -1700 -1459 -1377 -1789 226 1675 473 1423 -36 467 -403 -1835 -2338 331 -2116 962 3084 1509 -1854 -2253 815 -4685 25 1030 -3269 -3122 -961 -3327 -2542 1023 1830 1451 4423 3701 2601 6050 4166 1859 1691 -2794 610 514 -1125 3525 1452 1145 3763 3468 -1550 -1893 -1739 515 -693 8022 8139 -5209 259 -10629 -10797 -3313 -1595 3183 983 5289 6582 2947 388 -10889 -8655 -450 -2042 2483 -473 -11081 -3542 -1792 984 -2163 5859 7769 2994 208 -11425 -10382 -6456 -4559 -4399 13851 20352 11909 6930 5606 -4522 -8148 4705 -15081 -4879 -4830 -3245 -4397 5432 14621 12630 9978 6738 -8517 -1803 -12524 -3324 -4066 5088 -356 16713 5565 -2022 5880 -7414 -4604 2922 -846 4956 -4055 821 -18900 -1252 -5662 -8770 3397 15900 -3677 -1781 5860 4269 -4679 -13760 5106 -6920 4219 9719 -5529 14922 -523 -8510 900000 SS 20220907T152119.0Z 8285.639803 250 1 54.37 2 40.57 137.88 162.77 29.36 0.00 1 0.00 1 0 213 1.825e-02 1.271e-02 2.235e-03 1.438e-03 -1.603238e-05 5.194938e-07 6.535812e-07 4.989658e-07 8.259722e-06 229.88 -2.00 3.47 -2.00 321.20 0.00e+00 4.897776e-03 1.763587e-04 8.555799e-05 5.505646e-06 2.223759e-03 289.31 -2.00 20.00 -2.00 320.85 0.00e+00 5.674564e-03 2.466342e-04 2.706035e-04 3.335457e-05 3.773785e-03 289.31 -2.00 20.00 -2.00 321.16 0.00e+00 3.218804e-03 3.591963e-04 2.887496e-03 1.188530e-05 3.933348e-03 289.31 -2.00 20.00 -2.00 320.99 0.00e+00 1.606656e-01 1.568707e-03 7.218357e-03 1.110157e-02 2.062643e-02 179.53 2.20 0.00 2146.87 36.73 317.54 0.00e+00 7.732785e-05 7.330037e-05 7.819781e-05 1.949638e-06 4.879005e-04 289.31 -2.00 20.00 -2.00 315.77 0.00e+00 1.315 0.000 303.00 329.40 4 3.8348e+00 3.9323e-03 2.5048e-02 2.6245e-03 6.6458e-02 -7.8017e-02 4.4873e-03 3.3274e-02 6.3821e-04 7.0589e-02 7.5648e-02 2.8295e-03 1.1843e-02 2.0558e-04 3.9062e-02 -6.2089e-02 1.2646e-03 3.2613e-03 4.0704e-05 1.3986e-02 2.4017e-02 9.2079e-04 1.4786e-03 5.6652e-05 1.0743e-02 4.2264e-03 -7.3776e-02 8.2922e-04 3.0094e-03 3.4858e-05 1.0190e-02 3.7829e-02 3.6746e-05 9.5249e-05 6.5203e-07 4.7319e-04 9.5123e-02 0.0000e+00 6.9359e+00 1.1066e-01 5.7685e-02 1.9386e-03 1.1862e+00 12 12 12 10 0 0 99.96 25.26 1.78 0.09512 0.38376 111 12 1 8 0 489.439 20.01 25.26 29.73 29.25 31.00 15.3 1062.72 -69 2467 8169 2210 979 1444 -4950 -179 -3142 -2093 -1860 -3656 -1740 915 -2251 -2463 1353 -422 -760 527 6497 767 2547 5030 -1955 -1260 4983 904 421 1389 179 -1991 -585 373 -2421 1506 -192 -509 655 -1980 852 505 -1000 1377 -203 -551 1277 869 -971 60 -853 980 271 825 2435 -2994 -192 -1737 -3622 -119 430 -225 435 580 1020 329 294 -452 -1471 1899 625 -456 964 -3263 -642 723 242 -258 1092 1410 -272 173 -1078 -2191 -1681 -754 -971 1523 3524 1552 -67 1297 -1421 -2502 1194 -2288 -606 -333 -193 -1033 179 1424 1012 2104 1074 -1462 -408 -1577 -786 -1171 892 -654 1461 1274 -765 618 45 -906 750 -132 -636 183 598 -2501 304 -1117 -345 -79 2556 48 -802 403 351 220 -1505 247 -295 -22 685 -363 418 607 -302 86 -519 900000 -19 647 2234 683 330 488 -1762 -63 -1153 -779 -711 -1398 -654 358 -922 -1045 579 -173 -288 190 2337 294 1007 2153 -824 -490 2064 420 228 802 115 -1324 -395 255 -1645 1010 -128 -325 409 -1209 524 335 -690 979 -152 -412 966 665 -734 45 -653 782 214 687 2071 -2400 -149 -1317 -2719 -92 370 -202 398 508 863 255 221 -320 -1026 1456 498 -397 907 -3182 -607 733 256 -285 1207 1528 -277 173 -992 -1874 -1467 -718 -1010 1584 3956 1756 -72 1305 -1448 -2541 1229 -2556 -693 -399 -239 -1328 225 1817 1349 2595 1230 -1676 -456 -1834 -893 -1437 1146 -833 1819 1526 -929 716 50 -964 843 -159 -796 220 775 -3102 393 -1533 -491 -113 3737 70 -1123 556 473 296 -2143 377 -487 -35 1185 -645 747 1091 -523 150 -918 900000 SS 20220907T162532.9Z 8285.684409 287 1 4.05 2 34.30 162.25 154.19 60.18 0.00 1 0.00 1 7 260 8.026e-02 7.131e-02 3.087e-03 2.546e-03 -4.577858e-05 9.502410e-07 5.285446e-07 4.988852e-07 3.626652e-05 229.87 -2.00 3.47 -2.00 320.22 0.00e+00 2.389443e-02 3.018732e-04 2.029777e-04 6.101254e-06 9.795146e-03 289.31 -2.00 20.00 -2.00 319.68 0.00e+00 2.965660e-02 4.714434e-04 3.166115e-04 3.378537e-05 1.661704e-02 289.31 -2.00 20.00 -2.00 320.49 0.00e+00 1.939692e-02 5.595261e-04 2.305257e-03 1.118006e-05 1.729655e-02 289.31 -2.00 20.00 -2.00 320.06 0.00e+00 -1.583071e-02 2.992331e-03 4.787711e-03 1.109714e-02 9.059438e-02 5366.15 8256.93 0.00 30470.08 249924.00 316.14 0.00e+00 -6.330325e-04 9.658379e-05 5.000841e-05 1.980324e-06 2.139846e-03 289.31 -2.00 20.00 -2.00 314.29 0.00e+00 1.210 0.000 303.00 329.40 4 2.8405e+00 8.6071e-03 2.3477e-02 2.6167e-03 2.9192e-01 -7.8127e-01 1.0508e-02 2.3824e-02 6.1299e-04 3.1014e-01 3.9673e-01 5.6636e-03 8.1937e-03 1.8113e-04 1.7153e-01 -1.1448e-01 2.0504e-03 2.4593e-03 3.2592e-05 6.0661e-02 -1.3195e-02 1.6680e-03 1.3542e-03 5.1213e-05 4.7631e-02 1.8049e-02 -3.4313e-03 1.8829e-03 1.4376e-03 3.3424e-05 4.6809e-02 1.7068e-02 6.8569e-05 5.6810e-05 6.1500e-07 2.0886e-03 9.2683e-02 0.0000e+00 4.2382e+01 1.7614e-01 5.4366e-02 2.6287e-03 5.2890e+00 12 15 13 12 1 1 84.68 25.63 1.37 0.09268 0.22291 9 22 1 8 0 260.499 20.01 25.63 31.22 29.50 31.50 15.3 1070.14 -16941 7086 -14750 -11761 2154 -2586 1742 16049 -2466 14754 1271 8599 1365 -7902 -2143 5852 -5894 576 16228 7495 -4630 -8399 14786 -20895 -495 9593 -17011 -16442 2475 -9700 -10095 270 3862 -534 6508 7357 4107 11275 7128 4249 3053 -9611 1323 2519 -7474 4332 1926 1742 4373 4613 -5266 -4067 -3735 874 -3127 11378 14797 -10172 2077 -11102 -12724 -5589 -3247 1810 2229 8885 12579 5422 2826 -13262 -9553 29 -2586 607 902 -12236 -1532 -114 482 -3447 7756 8548 1381 1920 -8657 -11577 -8943 -5005 -5127 11522 18409 9325 3995 8355 -1360 -9397 5378 -13369 -3413 -5212 240 -4685 3067 8807 9742 8336 6545 -7005 800 -9530 -915 -3009 5702 -1771 14458 7150 -730 3399 -5578 -2052 4396 -1227 -703 -3539 2998 -13272 717 -4008 -3778 739 10202 -3143 -3207 2558 2168 -3336 -11184 2074 -4442 1008 4684 -737 8376 1714 -2946 900000 -7436 3127 -6503 -5472 1095 -1368 966 8743 -1342 8105 716 4905 757 -4523 -1284 3475 -3542 348 9019 4128 -2521 -4653 8417 -12358 -299 5369 -10166 -10022 1672 -7106 -7897 211 3048 -430 5180 5782 3216 8729 5373 3243 2342 -7645 1056 2068 -6231 3614 1620 1484 3682 3818 -4462 -3477 -3309 793 -2903 10280 12708 -8439 1715 -9860 -11852 -5230 -3101 1716 2035 7894 10319 4377 2224 -11103 -8390 27 -2520 598 919 -12753 -1666 -126 531 -3726 8078 8625 1323 1753 -8006 -11374 -9250 -5284 -5682 12876 19977 9790 4067 8445 -1460 -10418 6102 -15452 -4078 -6261 296 -5847 3727 10423 10972 9213 7040 -7808 914 -11194 -1098 -3679 6831 -2097 16611 8003 -794 3610 -6242 -2373 5148 -1445 -829 -4299 3698 -16988 946 -5318 -4984 975 13386 -4044 -4123 3298 2882 -4635 -15951 3038 -6781 1585 7401 -1171 12828 2678 -4580 900000 SS 20220907T202041.0Z 8285.847697 420 1 54.06 2 55.06 246.04 111.55 102.85 0.00 1 0.00 1 0 145 3.649e-02 1.512e-02 1.550e-02 6.219e-03 -1.581546e-05 2.238861e-06 8.132067e-07 4.991593e-07 1.616672e-05 229.86 -2.00 3.47 -2.00 322.41 0.00e+00 7.295715e-03 7.953430e-04 1.474383e-04 5.022769e-06 4.339379e-03 289.30 -2.00 20.00 -2.00 322.40 0.00e+00 6.442493e-03 1.077529e-03 1.958728e-04 3.310746e-05 7.507127e-03 289.30 -2.00 20.00 -2.00 322.03 0.00e+00 6.331640e-03 1.858546e-03 3.797942e-03 1.193350e-05 7.861123e-03 289.30 -2.00 20.00 -2.00 322.15 0.00e+00 2.100929e-01 7.777554e-03 1.110101e-02 1.110183e-02 4.142377e-02 178.35 8.13 0.00 1223.67 73.40 319.47 0.00e+00 3.722982e-04 4.857788e-04 1.996759e-04 2.117363e-06 9.847579e-04 289.30 -2.00 20.00 -2.00 317.70 0.00e+00 1.741 0.000 303.00 329.40 4 5.3546e+00 1.8003e-02 2.7857e-02 2.6328e-03 1.3254e-01 -1.1969e-01 2.3126e-02 4.8498e-02 6.8230e-04 1.4129e-01 1.2406e-01 1.3863e-02 1.7638e-02 2.4476e-04 7.7426e-02 -9.2399e-02 7.6074e-03 4.4902e-03 6.1891e-05 2.8500e-02 2.6275e-02 4.7942e-03 2.6264e-03 7.0196e-05 2.1233e-02 5.4336e-04 -6.3378e-02 3.2753e-03 4.3766e-03 3.0587e-05 1.3010e-02 3.8133e-02 1.6894e-04 1.2391e-04 6.0613e-07 8.9309e-04 9.8596e-02 0.0000e+00 6.6696e+00 4.4557e-01 6.3756e-02 1.1229e-03 2.2280e+00 12 12 12 10 0 0 99.99 25.13 3.62 0.09860 0.38955 62 7 1 8 0 871.443 20.01 25.13 28.59 29.25 31.00 15.2 1056.84 6729 23961 9010 -5318 -4309 -1303 -1778 -917 -5030 6126 -3666 -1056 -6698 -3898 -5494 -3115 69 706 -891 8339 13580 -4412 3414 7061 -6825 -6549 6846 -244 -1445 7485 -894 -2242 1536 -2312 -1415 271 -2834 1498 -74 -443 319 313 1446 1256 -167 490 3102 1166 -1517 722 1322 1059 1969 1676 2133 -2901 -193 -1247 -3767 -849 569 -142 -1206 515 582 -395 -1769 -1767 -4535 2761 1382 68 1003 -3864 -1423 1215 -334 -692 908 1584 244 -1273 -1951 -2941 -804 -1623 177 1503 4776 1676 244 1118 -1726 -2270 -263 -2131 -278 733 -484 -954 422 1821 1857 2196 845 -2409 -1246 -1472 -1161 -615 1477 -885 2384 739 65 321 -238 -1133 -488 -1097 606 -746 973 -2301 -61 -1355 -735 -130 3159 -238 -766 657 -505 203 -1515 -60 -78 493 1511 -867 559 219 -430 211 -475 900000 883 2860 1264 -885 -777 -255 -354 -172 -1000 1259 -834 -233 -1552 -943 -1264 -732 16 174 -190 1772 2944 -1033 799 1781 -1955 -1760 1706 -70 -490 2762 -389 -1012 693 -1105 -653 126 -1343 658 -33 -191 143 151 715 660 -92 269 1725 664 -860 400 743 636 1256 1145 1509 -1930 -117 -735 -2240 -572 423 -110 -963 388 423 -263 -1073 -1012 -2650 1734 985 49 790 -3162 -1219 1102 -320 -688 897 1529 220 -1152 -1630 -2318 -646 -1460 159 1480 5029 1794 246 1149 -1664 -2173 -279 -2220 -296 816 -565 -1165 542 2384 2365 2833 1019 -2727 -1382 -1687 -1408 -795 1984 -1183 3077 927 75 362 -259 -1184 -549 -1326 753 -980 1271 -3113 -88 -2046 -1151 -204 5025 -378 -1166 979 -740 296 -2344 -101 -141 934 3056 -1826 1186 469 -891 438 -1012 900000