File name: Pandora94s1_GuatemalaCity_20251103_L2Fit_ffus5c4d20250225p1-8.txt File generation date: 20260423T101311.7Z Data description: Level 2 spectral fitting results file Data file version: ffus5c4p1-8 Local principal investigator: Daniel Alvarez Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 94 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora94_OF_v3d20240409.txt Instrument calibration file used: Pandora94s1_CF_v4d20250225.txt Level 1 file used: Pandora94s1_GuatemalaCity_20251103_L1_smca1c4d20250225p1-8.txt Full location name: Ciudad de Guatemala Short location name: GuatemalaCity Country of location: Guatemala Location latitude [deg]: 14.6192 Location longitude [deg]: -90.4838 Location altitude [m]: 1547 Local noon date: 20251103 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 326 592 Nominal wavelengths inside fitting window [nm]: 322.5843 322.7235 322.8627 323.0019 323.1410 323.2802 323.4193 323.5584 323.6975 323.8366 323.9757 324.1148 324.2539 324.3929 324.5320 324.6710 324.8100 324.9490 325.0880 325.2270 325.3660 325.5049 325.6439 325.7828 325.9218 326.0607 326.1996 326.3385 326.4773 326.6162 326.7551 326.8939 327.0328 327.1716 327.3104 327.4492 327.5880 327.7268 327.8655 328.0043 328.1430 328.2817 328.4205 328.5592 328.6979 328.8366 328.9752 329.1139 329.2525 329.3912 329.5298 329.6684 329.8070 329.9456 330.0842 330.2228 330.3613 330.4999 330.6384 330.7769 330.9154 331.0539 331.1924 331.3309 331.4693 331.6078 331.7462 331.8847 332.0231 332.1615 332.2999 332.4383 332.5766 332.7150 332.8533 332.9917 333.1300 333.2683 333.4066 333.5449 333.6831 333.8214 333.9597 334.0979 334.2361 334.3743 334.5125 334.6507 334.7889 334.9271 335.0652 335.2034 335.3415 335.4796 335.6178 335.7558 335.8939 336.0320 336.1701 336.3081 336.4462 336.5842 336.7222 336.8602 336.9982 337.1362 337.2741 337.4121 337.5500 337.6880 337.8259 337.9638 338.1017 338.2396 338.3774 338.5153 338.6531 338.7910 338.9288 339.0666 339.2044 339.3422 339.4800 339.6177 339.7555 339.8932 340.0309 340.1687 340.3064 340.4441 340.5817 340.7194 340.8571 340.9947 341.1323 341.2699 341.4075 341.5451 341.6827 341.8203 341.9579 342.0954 342.2329 342.3705 342.5080 342.6455 342.7829 342.9204 343.0579 343.1953 343.3328 343.4702 343.6076 343.7450 343.8824 344.0198 344.1571 344.2945 344.4318 344.5691 344.7065 344.8438 344.9811 345.1183 345.2556 345.3929 345.5301 345.6673 345.8045 345.9418 346.0789 346.2161 346.3533 346.4905 346.6276 346.7647 346.9018 347.0390 347.1760 347.3131 347.4502 347.5873 347.7243 347.8613 347.9984 348.1354 348.2724 348.4094 348.5463 348.6833 348.8202 348.9572 349.0941 349.2310 349.3679 349.5048 349.6417 349.7785 349.9154 350.0522 350.1890 350.3258 350.4626 350.5994 350.7362 350.8730 351.0097 351.1464 351.2832 351.4199 351.5566 351.6933 351.8299 351.9666 352.1033 352.2399 352.3765 352.5131 352.6497 352.7863 352.9229 353.0595 353.1960 353.3326 353.4691 353.6056 353.7421 353.8786 354.0151 354.1515 354.2880 354.4244 354.5608 354.6972 354.8336 354.9700 355.1064 355.2428 355.3791 355.5155 355.6518 355.7881 355.9244 356.0607 356.1970 356.3332 356.4695 356.6057 356.7419 356.8781 357.0143 357.1505 357.2867 357.4229 357.5590 357.6951 357.8313 357.9674 358.1035 358.2396 358.3756 358.5117 358.6477 358.7838 358.9198 359.0558 359.1918 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-703: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20251103T142006.5Z 9438.597298 260 1 2.86 2 58.90 118.36 147.84 311.28 0.00 1 0.00 1 0 33 8.895e-04 8.462e-04 8.566e-04 8.302e-04 1.746742e-07 2.599043e-07 6.162366e-08 3.794550e-07 2.766029e-07 226.05 -2.00 3.09 -2.00 339.49 0.00e+00 1.127761e-04 7.083158e-05 1.205437e-05 1.773598e-05 7.542335e-05 285.98 -2.00 20.00 -2.00 336.88 0.00e+00 1.201503e-05 1.145548e-05 1.684267e-06 2.510460e-05 1.337854e-05 285.98 -2.00 20.00 -2.00 345.75 0.00e+00 1.578686e-04 3.288681e-05 1.347053e-05 1.958924e-05 3.757596e-05 285.98 -2.00 20.00 -2.00 344.29 0.00e+00 2.206780e+05 6.648596e+04 3.135431e+04 1.986690e+05 7.104178e+04 265.82 -2.00 10.01 -2.00 351.97 0.00e+00 2.118248e-01 9.359068e-04 1.554453e-03 1.826086e-03 8.995446e-04 226.05 -2.00 3.09 -2.00 329.90 0.00e+00 1.145625e-03 1.380827e-03 7.675425e-04 1.359638e-04 1.155962e-03 285.98 -2.00 20.00 -2.00 327.78 0.00e+00 1.928 0.000 319.50 362.20 4 2.3102e+00 1.0585e-03 1.1353e-02 1.4356e-03 1.1894e-03 3.5641e-02 2.6183e-04 1.7705e-03 2.7004e-04 2.8201e-04 1.3416e-03 5.0079e-04 3.0852e-04 9.2890e-05 5.3645e-04 -9.2673e-04 2.5625e-04 3.1361e-04 8.2824e-05 2.3389e-04 -9.2452e-05 3.9505e-04 2.7427e-04 7.5756e-05 3.9486e-04 2.9621e-02 9.2676e-04 6.2272e-04 1.3084e-04 6.2322e-05 6.6296e-04 6.1403e-05 1.0651e-05 1.7239e-06 5.9625e-07 1.1777e-05 1.7139e-03 0.0000e+00 3.3953e-02 6.1540e-02 9.5114e-03 3.4443e-03 6.6236e-02 12 9 9 12 1 1 99.62 24.07 0.26 0.00171 0.00247 13 28 1 5 0 203.760 32.00 20.00 24.07 22.82 2.5 960.37 94 -180 -2 -107 89 183 -67 82 -97 -190 -66 231 268 -13 -280 49 149 -148 -91 72 -105 42 33 -11 213 65 154 -135 50 -50 130 -4 -179 23 -75 -197 -117 25 -70 20 -39 -7 88 52 100 178 -80 -72 -1 -77 -58 38 -77 -94 69 -45 -112 -31 90 -59 -118 -41 40 32 199 37 185 47 36 103 96 -59 1 44 -232 47 186 -209 95 -69 -64 -40 -2 58 32 110 -66 -41 -74 -100 113 -37 -16 -29 -57 100 31 54 -22 -135 -86 -73 -32 144 8 34 56 255 -7 92 -40 -5 -178 -12 -36 5 -30 100 122 -66 -97 40 -86 59 -14 -53 -48 -56 7 132 -32 136 14 114 15 -65 1 -34 -19 -82 14 13 110 -54 -71 50 -73 -32 106 37 -46 36 74 43 68 -56 83 -3 -86 2 60 23 -9 -118 64 -120 77 -48 -62 -14 21 -130 97 -116 -55 -10 -40 81 -203 3 -64 23 69 63 130 59 -64 -30 -93 97 105 -66 14 -20 -14 74 -24 45 -23 19 -92 -78 110 -50 89 -111 3 -23 68 33 -28 -11 -27 -1 139 -127 28 -49 135 -72 -93 -102 21 -12 162 -33 66 -66 6 98 -70 60 -59 17 15 42 75 9 6 -100 19 -86 17 58 52 20 5 -68 68 -74 26 0 75 -23 -25 76 -9 10 -106 -29 -120 45 76 -19 -21 9 -36 61 -112 -1 -70 59 125 -47 58 -69 -140 -50 175 208 -10 -216 37 112 -108 -69 55 -84 35 29 -10 191 60 139 -122 45 -46 118 -4 -160 20 -67 -179 -105 22 -61 18 -34 -6 77 46 88 161 -75 -71 -1 -77 -59 38 -79 -97 70 -44 -106 -29 82 -55 -111 -38 38 31 186 35 179 47 35 99 92 -57 1 43 -226 45 182 -205 90 -64 -59 -37 -2 57 32 111 -68 -41 -72 -99 111 -38 -17 -30 -60 98 28 46 -19 -126 -85 -73 -30 131 7 30 51 249 -7 94 -40 -4 -171 -12 -37 6 -31 106 128 -66 -96 40 -88 62 -16 -59 -53 -62 8 139 -33 141 15 119 15 -66 1 -34 -20 -89 15 14 119 -57 -75 54 -81 -36 117 41 -50 39 79 45 66 -51 72 -3 -79 2 61 24 -9 -129 70 -130 83 -52 -64 -14 21 -133 102 -125 -59 -11 -44 89 -221 3 -63 23 69 66 140 64 -68 -32 -100 105 111 -69 14 -20 -15 75 -24 48 -26 22 -108 -92 127 -58 102 -126 3 -25 71 35 -30 -13 -31 -1 153 -133 28 -48 136 -76 -103 -115 24 -13 183 -38 77 -77 7 114 -81 70 -69 20 17 50 87 11 6 -111 21 -95 19 66 59 22 6 -68 65 -71 25 0 75 -24 -27 80 -9 9 -94 -25 -102 39 66 -17 -20 9 -39 SS 20251103T152706.8Z 9438.643829 309 1 54.64 2 45.42 129.73 156.50 340.11 0.00 1 0.00 1 0 33 5.920e-03 5.558e-03 3.097e-03 2.975e-03 6.538511e-07 9.243628e-07 3.920345e-07 3.795314e-07 1.839166e-06 226.04 -2.00 3.09 -2.00 339.00 0.00e+00 -6.177116e-04 2.484280e-04 9.165095e-05 1.774100e-05 4.926978e-04 285.98 -2.00 20.00 -2.00 336.37 0.00e+00 1.007866e-04 4.216322e-05 1.179440e-05 2.510407e-05 9.055623e-05 285.98 -2.00 20.00 -2.00 345.25 0.00e+00 -2.065851e-05 1.192604e-04 3.755273e-05 1.961258e-05 2.499637e-04 285.98 -2.00 20.00 -2.00 343.70 0.00e+00 8.991069e+04 2.377405e+05 1.455449e+05 1.986279e+05 4.672498e+05 265.82 -2.00 10.01 -2.00 351.29 0.00e+00 1.567976e-01 3.228656e-03 1.665706e-03 1.825428e-03 5.871073e-03 226.04 -2.00 3.09 -2.00 329.91 0.00e+00 6.953943e-03 5.054077e-03 7.335549e-03 1.343679e-04 7.687333e-03 285.98 -2.00 20.00 -2.00 327.84 0.00e+00 1.423 0.000 319.50 362.20 4 7.6838e+00 3.7904e-03 8.4393e-03 1.4361e-03 7.8693e-03 8.7130e-02 9.1732e-04 1.4370e-03 2.7043e-04 1.8461e-03 -9.3216e-03 1.7606e-03 1.0713e-03 9.0946e-05 3.4932e-03 -2.2538e-03 9.3318e-04 1.0908e-03 8.2279e-05 1.5440e-03 3.3878e-03 1.4026e-03 1.4163e-03 7.5717e-05 2.5485e-03 1.9000e-04 -2.0499e-02 2.2377e-03 1.3189e-04 5.5827e-05 4.5692e-03 2.7538e-04 3.9478e-05 1.6513e-06 6.4100e-07 7.8561e-05 -1.0477e-03 0.0000e+00 9.6796e-01 2.2687e-01 9.8405e-03 2.8645e-03 4.4991e-01 12 8 8 10 0 0 99.96 24.25 1.45 -0.00105 0.00235 37 4 1 5 0 1476.520 32.00 20.00 24.25 23.53 2.4 962.88 911 -2591 -1148 72 528 613 1310 -292 -849 606 -174 1108 504 33 324 -958 -15 -32 -492 882 657 -118 6 149 277 45 -486 651 -506 -158 -204 -243 -932 -1406 35 -134 -200 -241 -18 470 382 -207 604 -321 659 -261 -703 -101 97 -32 144 361 186 72 28 -275 218 914 -192 987 -258 -800 374 871 8 -473 424 915 -535 547 1205 -784 578 -369 -208 -565 -545 581 -495 -798 639 -238 -360 -157 -247 -375 941 -224 -692 -997 174 -422 391 -73 -239 74 -635 735 387 -230 1058 469 -172 899 -697 -603 -1407 445 1121 95 309 323 -17 -293 -185 -203 261 94 333 155 43 280 -556 -219 -140 -284 -166 676 -96 -377 677 -236 -280 843 -479 -252 -102 -434 -267 881 -402 176 203 294 -623 -139 -698 171 -402 -80 766 929 86 -314 -413 -90 574 -43 -1427 554 352 150 -287 464 825 120 -612 -585 33 -475 -66 49 -498 -41 -379 1472 368 21 131 -364 -562 -275 78 -1354 -498 169 1012 -1080 276 -610 152 607 578 -791 198 121 753 320 -156 865 -251 75 107 -262 -44 822 -392 -414 -455 124 -446 323 -205 119 55 190 223 -241 963 -232 -268 226 -34 361 346 -159 -819 -323 1401 -454 459 -444 572 -149 -371 -442 -282 433 -95 8 -202 -427 478 -321 -1069 243 131 -505 -578 -336 -95 750 -342 229 1692 1078 -322 399 289 13 -1685 1623 -132 -463 386 -681 -160 539 -1492 -647 43 331 400 862 -197 -590 441 -134 860 403 27 256 -747 -12 -23 -372 697 562 -100 6 140 266 44 -470 605 -480 -151 -199 -236 -887 -1324 32 -125 -185 -218 -16 408 334 -185 525 -276 572 -240 -696 -107 107 -35 163 406 213 76 31 -298 216 839 -178 915 -251 -804 365 828 8 -470 432 945 -545 528 1154 -778 578 -375 -208 -562 -548 576 -473 -730 619 -217 -345 -156 -253 -397 1006 -237 -697 -998 175 -447 438 -83 -261 72 -581 593 323 -220 1015 457 -157 810 -599 -520 -1322 418 1146 100 308 305 -15 -278 -191 -216 279 103 354 157 42 268 -558 -238 -163 -319 -187 804 -111 -417 716 -246 -293 884 -499 -251 -99 -420 -276 983 -468 202 225 317 -664 -152 -813 201 -475 -92 857 1010 94 -329 -377 -79 462 -35 -1270 535 343 159 -319 514 927 135 -684 -641 34 -453 -62 49 -519 -45 -423 1630 427 23 144 -373 -524 -254 75 -1418 -549 184 1063 -1157 300 -674 161 614 548 -766 195 118 757 342 -165 989 -307 91 126 -308 -50 898 -425 -422 -479 123 -471 362 -239 134 58 196 212 -225 937 -232 -291 252 -39 412 398 -176 -934 -364 1547 -517 515 -510 661 -174 -434 -511 -318 464 -100 8 -208 -450 503 -349 -1187 249 134 -478 -492 -282 -82 647 -320 231 1608 1076 -301 323 215 10 -1281 1142 -97 -366 354 -660 -164 SS 20251103T163742.2Z 9438.692849 356 1 1.18 2 34.28 150.04 155.83 21.95 0.00 1 0.00 1 0 33 1.489e-03 1.482e-03 1.511e-03 1.481e-03 2.561763e-08 4.560542e-07 3.179888e-08 3.795177e-07 4.626685e-07 226.04 -2.00 3.09 -2.00 338.93 0.00e+00 -1.299374e-05 1.229253e-04 4.284032e-06 1.771109e-05 1.243384e-04 285.98 -2.00 20.00 -2.00 336.31 0.00e+00 3.280623e-05 2.090894e-05 2.057158e-06 2.510386e-05 2.268064e-05 285.98 -2.00 20.00 -2.00 345.26 0.00e+00 2.296211e-05 5.936524e-05 8.674697e-06 1.962433e-05 6.286065e-05 285.98 -2.00 20.00 -2.00 343.72 0.00e+00 -1.631200e+05 1.167478e+05 3.016842e+04 1.986279e+05 1.178406e+05 265.82 -2.00 10.01 -2.00 351.73 0.00e+00 1.348019e-01 1.565441e-03 1.028802e-03 1.825805e-03 1.472846e-03 226.04 -2.00 3.09 -2.00 329.58 0.00e+00 -2.282459e-03 2.306434e-03 2.516702e-03 1.354989e-04 1.935590e-03 285.98 -2.00 20.00 -2.00 327.48 0.00e+00 1.209 0.000 319.50 362.20 4 2.8658e+00 1.8931e-03 7.1201e-03 1.4359e-03 1.9782e-03 3.2121e-02 4.5525e-04 1.1159e-03 2.7024e-04 4.6590e-04 3.1780e-04 8.6980e-04 2.0033e-04 8.6829e-05 8.8218e-04 -1.0174e-03 4.3436e-04 3.6351e-04 8.3719e-05 3.8832e-04 7.6041e-04 6.7393e-04 3.2983e-04 7.6406e-05 6.4459e-04 2.6175e-02 4.2438e-04 1.1263e-03 7.6996e-05 5.9426e-05 1.1287e-03 6.3407e-05 1.9225e-05 1.3787e-06 6.3327e-07 1.9723e-05 8.6413e-04 0.0000e+00 2.7118e-02 1.1351e-01 6.0580e-03 3.2184e-03 1.1544e-01 12 9 9 12 1 1 97.97 24.30 0.28 0.00086 0.00165 4 24 1 5 0 235.190 32.00 20.00 24.30 23.58 2.4 963.23 61 -24 -71 -267 -256 -11 79 403 303 -16 -144 231 -34 -87 -149 -62 -73 14 82 191 -35 54 95 -35 4 29 130 151 77 -94 76 -154 96 -200 19 -313 -1 -202 5 -80 -103 236 79 -69 -22 -43 -172 90 242 -127 44 -298 -265 5 -30 38 -77 -85 -8 20 177 294 -28 23 28 411 -43 174 -164 100 60 81 12 -200 -81 63 -159 273 -153 -53 98 -68 -267 192 -33 141 283 198 -185 190 -97 11 71 -20 -152 -90 -79 25 -142 142 -108 -187 -13 32 61 25 -237 70 112 176 39 204 -97 -242 -262 -191 -100 184 31 267 -222 132 20 148 284 -18 81 -87 76 -117 -102 -82 14 -184 8 -41 23 77 -45 -128 60 -38 -28 41 -55 8 -76 149 66 120 -102 158 56 -94 123 -310 -14 12 277 -103 -19 10 -43 -91 -480 -100 168 71 164 -36 166 181 15 -195 -46 224 -57 -186 -24 -14 -158 65 53 -331 -129 -171 -40 228 99 94 13 -229 339 194 -77 92 27 149 -128 -7 231 125 5 -8 210 -155 93 36 11 -116 -126 137 22 -90 -122 123 6 -73 18 -9 -119 107 -120 -157 251 -32 -61 -181 7 38 238 -38 97 -46 35 -79 -72 289 -90 -66 150 -335 -20 -61 -342 0 172 34 18 318 -178 -158 20 -80 72 184 73 -4 173 -64 -108 155 -244 -154 96 -116 189 43 -16 -49 -191 -188 -8 59 304 230 -13 -117 187 -28 -73 -123 -51 -58 11 66 158 -30 48 87 -33 4 28 124 142 73 -89 74 -149 92 -189 18 -298 -1 -191 4 -73 -94 218 72 -63 -20 -40 -169 91 250 -133 46 -312 -283 5 -31 38 -75 -81 -7 19 172 289 -27 22 27 407 -43 175 -164 97 58 80 12 -201 -82 63 -157 275 -150 -50 92 -65 -264 192 -33 145 298 204 -184 190 -97 12 75 -22 -160 -90 -72 21 -126 134 -107 -187 -12 29 54 22 -218 68 116 183 39 200 -93 -239 -271 -200 -106 195 33 270 -223 130 20 155 308 -20 91 -96 83 -126 -107 -85 15 -194 8 -41 23 77 -46 -139 66 -41 -30 44 -57 8 -83 166 74 131 -111 167 59 -98 118 -283 -12 10 251 -99 -19 10 -46 -97 -518 -107 181 75 168 -35 164 181 15 -205 -49 239 -62 -203 -25 -14 -154 63 52 -339 -138 -182 -41 238 105 99 14 -231 330 191 -78 91 27 155 -138 -8 268 143 5 -9 234 -169 101 38 12 -120 -133 150 25 -99 -129 124 6 -70 18 -9 -127 116 -132 -173 277 -36 -69 -205 8 43 268 -43 112 -53 39 -90 -80 317 -98 -71 160 -361 -21 -67 -374 0 175 33 17 289 -163 -147 19 -81 74 182 70 -3 146 -53 -88 128 -203 -135 90 -115 194 SS 20251103T170817.0Z 9438.714086 377 1 0.27 2 31.30 162.52 152.26 36.28 0.00 1 0.00 1 0 33 2.851e-03 2.875e-03 2.869e-03 2.813e-03 2.460067e-07 8.672511e-07 5.077372e-08 3.795143e-07 8.858708e-07 226.04 -2.00 3.09 -2.00 338.89 0.00e+00 1.445623e-04 2.328051e-04 1.025426e-05 1.771032e-05 2.375073e-04 285.98 -2.00 20.00 -2.00 336.27 0.00e+00 5.499652e-05 3.985020e-05 1.510159e-06 2.510372e-05 4.346362e-05 285.98 -2.00 20.00 -2.00 345.20 0.00e+00 1.596889e-04 1.129051e-04 9.894698e-06 1.962610e-05 1.203781e-04 285.98 -2.00 20.00 -2.00 343.67 0.00e+00 3.162737e+05 2.219231e+05 2.538918e+04 1.986208e+05 2.254014e+05 265.82 -2.00 10.01 -2.00 351.70 0.00e+00 1.284760e-01 2.956368e-03 9.554209e-04 1.825766e-03 2.817361e-03 226.04 -2.00 3.09 -2.00 329.57 0.00e+00 8.117459e-04 4.369461e-03 8.351123e-04 1.347147e-04 3.703717e-03 285.98 -2.00 20.00 -2.00 327.47 0.00e+00 1.170 0.000 319.50 362.20 4 2.2096e+00 3.5870e-03 6.8902e-03 1.4359e-03 3.7701e-03 3.4239e-02 8.6450e-04 1.0765e-03 2.7036e-04 8.9143e-04 2.4838e-03 1.6493e-03 2.1382e-04 8.6845e-05 1.6855e-03 -9.2390e-04 8.2324e-04 2.1559e-04 8.3581e-05 7.4269e-04 -9.3558e-04 1.2772e-03 2.1951e-04 7.6206e-05 1.2303e-03 5.1190e-02 5.1173e-03 2.1524e-03 7.1469e-05 5.9097e-05 2.1497e-03 4.3939e-05 3.6786e-05 1.1765e-06 6.3835e-07 3.7800e-05 -2.1005e-04 0.0000e+00 3.8032e-01 2.1555e-01 4.9095e-03 3.1959e-03 2.2085e-01 12 9 9 12 1 1 999.00 24.36 0.32 -0.00021 0.00033 1 43 1 5 0 132.930 32.25 20.00 24.36 24.93 2.4 969.22 -16 81 -171 -107 419 111 -51 -30 333 -47 -29 -91 -103 -74 -271 149 -789 -21 213 -138 117 254 40 183 3 209 259 -413 98 -370 -35 -133 433 101 56 361 -241 -278 -285 93 328 -249 -91 -81 167 -307 -109 56 290 34 27 -144 381 -975 198 16 -422 178 721 -18 572 -59 -118 204 337 157 -169 148 334 83 256 -365 -407 -196 -282 125 -216 -214 -10 259 -125 535 -376 -223 -488 -143 23 -21 -323 -142 -74 -212 584 184 399 -300 -112 201 -203 356 13 614 104 -9 243 206 -111 191 -659 136 -81 -44 -570 -154 619 342 -254 -133 228 -281 355 -137 565 -267 487 -757 88 -250 -275 -633 -68 763 -114 -229 -81 51 38 259 -190 2 -191 -37 510 -10 169 250 -96 61 -85 270 -276 -289 3 350 -129 272 -354 -309 -164 188 -30 -107 132 458 239 -412 114 103 -447 252 149 116 163 -230 421 492 44 -320 89 466 -556 -382 -206 -11 -189 74 -163 -42 -399 -581 83 426 461 -163 1 -243 -344 359 -132 198 -188 223 -127 226 214 120 526 -164 -246 -53 70 71 154 -37 -67 -106 46 -174 -63 -227 -198 166 -214 110 27 197 -93 -301 -518 -117 -102 186 -32 228 -92 353 148 89 -142 -95 -142 60 311 -374 459 -335 60 280 610 -19 2 103 -465 14 280 219 -267 -138 143 22 -228 -265 -275 415 -101 75 -137 -12 56 -119 -76 304 82 -38 -22 257 -37 -24 -74 -86 -62 -225 122 -637 -17 171 -115 101 229 37 176 3 202 246 -390 93 -357 -34 -128 411 94 52 340 -227 -260 -266 86 302 -230 -84 -74 152 -290 -106 57 301 36 28 -151 404 -1038 205 17 -422 170 686 -18 562 -59 -116 199 330 155 -170 151 338 82 251 -360 -411 -195 -282 124 -217 -215 -10 248 -119 514 -368 -223 -495 -147 24 -22 -326 -141 -75 -217 625 197 423 -297 -103 174 -179 336 13 615 99 -8 214 182 -103 189 -684 141 -82 -43 -553 -150 629 355 -268 -141 238 -289 357 -136 568 -280 528 -854 99 -276 -298 -679 -72 790 -118 -239 -84 51 38 258 -196 2 -209 -40 547 -11 176 265 -104 67 -94 291 -299 -310 3 362 -125 246 -307 -266 -148 180 -30 -113 140 488 259 -447 122 110 -455 250 148 117 168 -244 449 530 48 -348 95 473 -545 -370 -205 -12 -201 78 -170 -43 -421 -610 87 431 451 -159 1 -242 -349 370 -142 221 -216 256 -143 253 234 130 565 -173 -251 -54 74 78 172 -41 -71 -107 45 -165 -62 -234 -212 181 -232 120 29 221 -104 -336 -578 -132 -114 210 -36 259 -105 396 165 96 -152 -102 -152 64 335 -410 500 -353 61 270 563 -17 1 96 -446 14 286 217 -257 -124 121 18 -185 -219 -229 356 -94 74 -141 SS 20251103T180750.1Z 9438.755441 418 1 54.33 2 30.43 190.67 142.20 54.53 0.00 1 0.00 1 0 33 1.270e-03 1.221e-03 8.725e-04 8.537e-04 3.729389e-07 2.630578e-07 8.739675e-08 3.795250e-07 3.943851e-07 226.04 -2.00 3.09 -2.00 338.82 0.00e+00 -9.712702e-05 7.059830e-05 1.964515e-05 1.770983e-05 1.054484e-04 285.98 -2.00 20.00 -2.00 336.20 0.00e+00 3.435452e-06 1.209377e-05 2.989735e-06 2.510367e-05 1.943050e-05 285.98 -2.00 20.00 -2.00 345.16 0.00e+00 2.876161e-06 3.433170e-05 1.106506e-05 1.963183e-05 5.360093e-05 285.98 -2.00 20.00 -2.00 343.58 0.00e+00 -1.273738e+05 6.735627e+04 4.196913e+04 1.986122e+05 1.002437e+05 265.82 -2.00 10.01 -2.00 351.58 0.00e+00 1.308587e-01 8.946324e-04 1.046343e-03 1.825889e-03 1.253799e-03 226.04 -2.00 3.09 -2.00 329.59 0.00e+00 5.648222e-04 1.330953e-03 2.327762e-03 1.343567e-04 1.648836e-03 285.98 -2.00 20.00 -2.00 327.51 0.00e+00 1.159 0.000 319.50 362.20 4 5.7730e+00 1.0883e-03 6.8280e-03 1.4359e-03 1.6832e-03 5.1758e-02 2.6122e-04 1.0775e-03 2.7041e-04 3.9612e-04 -3.3754e-03 4.9905e-04 3.1188e-04 8.6705e-05 7.4881e-04 -1.3059e-03 2.5077e-04 3.6589e-04 8.3698e-05 3.3035e-04 2.0024e-03 3.8721e-04 4.1545e-04 7.6153e-05 5.4582e-04 1.4878e-03 -9.5372e-03 6.4299e-04 7.9481e-05 5.8123e-05 9.6986e-04 8.6780e-05 1.1184e-05 1.3223e-06 6.5638e-07 1.6838e-05 -6.9806e-04 0.0000e+00 2.0647e-01 6.5653e-02 6.0464e-03 3.0890e-03 9.8432e-02 12 8 8 10 0 0 99.99 24.46 0.75 -0.00070 0.00037 59 6 1 5 0 920.690 32.25 20.00 24.46 24.94 2.4 968.57 5 -109 -58 29 116 156 488 284 -151 58 -41 137 -212 -158 -75 -328 -136 -205 109 283 29 92 62 158 188 -30 -258 191 -63 -219 40 -118 -275 -251 -45 -196 -88 169 -156 -142 -89 171 16 -46 229 -45 -78 -89 108 232 62 0 84 84 -62 -167 -11 83 -131 172 65 -137 113 -1 149 126 61 136 36 106 -3 -118 15 31 19 -98 -176 238 -36 -107 43 -52 -24 -10 -11 -56 155 10 -110 -85 76 -275 92 18 64 -13 -140 146 70 38 25 -4 27 21 -89 194 -44 110 159 116 111 -45 14 -46 -62 -163 -46 -68 84 115 -67 -88 -102 -134 -91 66 61 103 49 -33 237 -49 -188 -11 -221 -163 54 -81 -43 -80 -155 106 51 50 -190 13 -123 138 2 99 125 99 -25 -63 -119 -66 347 42 -111 -23 -69 310 -102 -9 69 63 -51 -30 17 -165 47 -46 16 35 33 153 63 0 67 -236 -171 71 -17 -218 -32 -82 26 -1 234 70 -81 -73 20 -175 -174 -49 95 -69 -66 176 75 58 32 56 19 114 98 -169 -3 -94 -159 24 -198 3 161 60 134 4 283 -185 -149 146 110 -65 70 -79 74 65 162 -8 33 85 39 5 27 -145 -56 71 11 -126 -246 -39 -41 -120 -24 55 -48 -100 -112 -103 1 -39 -79 128 193 210 -9 133 -71 115 -115 298 -34 -4 -43 -86 -74 3 -75 -40 20 84 117 370 205 -112 46 -32 110 -175 -132 -61 -262 -111 -164 89 231 26 82 57 152 184 -29 -251 179 -60 -211 39 -115 -262 -236 -42 -186 -83 162 -147 -133 -83 162 15 -42 211 -44 -78 -91 114 248 67 0 89 90 -66 -175 -11 82 -129 162 64 -139 112 -1 144 125 63 137 37 104 -3 -117 15 31 19 -97 -177 240 -35 -104 40 -50 -23 -10 -11 -57 161 10 -111 -85 77 -281 100 20 68 -13 -131 127 60 35 25 -4 26 20 -78 170 -39 110 166 119 112 -45 13 -46 -64 -168 -48 -73 87 118 -66 -86 -103 -140 -98 75 69 114 55 -35 244 -52 -200 -11 -233 -164 53 -79 -45 -88 -168 118 54 52 -196 13 -133 152 2 111 137 106 -26 -64 -116 -60 303 37 -100 -22 -69 318 -110 -10 75 69 -55 -32 18 -159 45 -47 16 37 36 167 68 0 72 -235 -162 66 -17 -220 -35 -87 27 -2 247 75 -84 -72 20 -171 -176 -49 93 -72 -71 196 85 68 37 64 21 121 107 -174 -3 -94 -169 26 -225 4 172 60 130 4 270 -186 -157 159 120 -72 78 -87 84 73 182 -9 37 98 44 6 31 -162 -63 77 11 -136 -255 -41 -44 -131 -26 57 -47 -95 -100 -91 1 -36 -75 126 196 207 -9 115 -59 91 -93 235 -27 -3 -40 -84 -74