File name: Pandora37s1_HamptonVA_20210218_L2Fit_fnvs5c6d20201125p1-8.txt File generation date: 20250726T004353.7Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c6p1-8 Local principal investigator: David Flittner Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 37 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora37_OF_v3d20200313.txt Instrument calibration file used: Pandora37s1_CF_v6d20201125.txt Level 1 file used: Pandora37s1_HamptonVA_20210218_L1_smca1c6d20201125p1-8.txt Full location name: Langley Research Center Short location name: HamptonVA Country of location: USA Location latitude [deg]: 37.1036 Location longitude [deg]: -76.3868 Location altitude [m]: 4 Local noon date: 20210218 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 950 1499 Nominal wavelengths inside fitting window [nm]: 400.0575 400.1890 400.3204 400.4519 400.5833 400.7147 400.8461 400.9775 401.1089 401.2402 401.3716 401.5029 401.6342 401.7655 401.8968 402.0281 402.1593 402.2906 402.4218 402.5530 402.6842 402.8154 402.9466 403.0777 403.2089 403.3400 403.4711 403.6022 403.7333 403.8644 403.9954 404.1265 404.2575 404.3885 404.5195 404.6505 404.7815 404.9124 405.0434 405.1743 405.3052 405.4361 405.5670 405.6978 405.8287 405.9595 406.0903 406.2212 406.3520 406.4827 406.6135 406.7442 406.8750 407.0057 407.1364 407.2671 407.3978 407.5284 407.6591 407.7897 407.9204 408.0510 408.1816 408.3121 408.4427 408.5732 408.7038 408.8343 408.9648 409.0953 409.2258 409.3562 409.4867 409.6171 409.7475 409.8779 410.0083 410.1387 410.2690 410.3994 410.5297 410.6600 410.7903 410.9206 411.0509 411.1811 411.3114 411.4416 411.5718 411.7020 411.8322 411.9624 412.0925 412.2226 412.3528 412.4829 412.6130 412.7431 412.8731 413.0032 413.1332 413.2632 413.3932 413.5232 413.6532 413.7832 413.9131 414.0430 414.1730 414.3029 414.4328 414.5626 414.6925 414.8223 414.9522 415.0820 415.2118 415.3416 415.4713 415.6011 415.7308 415.8606 415.9903 416.1200 416.2496 416.3793 416.5090 416.6386 416.7682 416.8978 417.0274 417.1570 417.2866 417.4161 417.5457 417.6752 417.8047 417.9342 418.0636 418.1931 418.3226 418.4520 418.5814 418.7108 418.8402 418.9696 419.0989 419.2283 419.3576 419.4869 419.6162 419.7455 419.8747 420.0040 420.1332 420.2625 420.3917 420.5209 420.6500 420.7792 420.9084 421.0375 421.1666 421.2957 421.4248 421.5539 421.6829 421.8120 421.9410 422.0700 422.1990 422.3280 422.4570 422.5859 422.7149 422.8438 422.9727 423.1016 423.2305 423.3594 423.4882 423.6170 423.7459 423.8747 424.0035 424.1322 424.2610 424.3897 424.5185 424.6472 424.7759 424.9046 425.0332 425.1619 425.2905 425.4192 425.5478 425.6764 425.8050 425.9335 426.0621 426.1906 426.3191 426.4476 426.5761 426.7046 426.8331 426.9615 427.0900 427.2184 427.3468 427.4752 427.6035 427.7319 427.8602 427.9886 428.1169 428.2452 428.3734 428.5017 428.6300 428.7582 428.8864 429.0146 429.1428 429.2710 429.3992 429.5273 429.6554 429.7835 429.9116 430.0397 430.1678 430.2959 430.4239 430.5519 430.6799 430.8079 430.9359 431.0639 431.1918 431.3198 431.4477 431.5756 431.7035 431.8313 431.9592 432.0871 432.2149 432.3427 432.4705 432.5983 432.7260 432.8538 432.9815 433.1093 433.2370 433.3647 433.4923 433.6200 433.7477 433.8753 434.0029 434.1305 434.2581 434.3857 434.5132 434.6408 434.7683 434.8958 435.0233 435.1508 435.2782 435.4057 435.5331 435.6606 435.7880 435.9153 436.0427 436.1701 436.2974 436.4248 436.5521 436.6794 436.8067 436.9339 437.0612 437.1884 437.3156 437.4428 437.5700 437.6972 437.8244 437.9515 438.0787 438.2058 438.3329 438.4600 438.5870 438.7141 438.8411 438.9682 439.0952 439.2222 439.3491 439.4761 439.6031 439.7300 439.8569 439.9838 440.1107 440.2376 440.3644 440.4913 440.6181 440.7449 440.8717 440.9985 441.1253 441.2520 441.3787 441.5055 441.6322 441.7589 441.8855 442.0122 442.1388 442.2655 442.3921 442.5187 442.6453 442.7718 442.8984 443.0249 443.1514 443.2779 443.4044 443.5309 443.6574 443.7838 443.9102 444.0367 444.1630 444.2894 444.4158 444.5422 444.6685 444.7948 444.9211 445.0474 445.1737 445.3000 445.4262 445.5524 445.6786 445.8048 445.9310 446.0572 446.1833 446.3095 446.4356 446.5617 446.6878 446.8139 446.9399 447.0660 447.1920 447.3180 447.4440 447.5700 447.6960 447.8219 447.9479 448.0738 448.1997 448.3256 448.4515 448.5773 448.7032 448.8290 448.9548 449.0806 449.2064 449.3322 449.4579 449.5837 449.7094 449.8351 449.9608 450.0865 450.2121 450.3378 450.4634 450.5890 450.7146 450.8402 450.9658 451.0913 451.2169 451.3424 451.4679 451.5934 451.7189 451.8443 451.9698 452.0952 452.2206 452.3460 452.4714 452.5968 452.7221 452.8475 452.9728 453.0981 453.2234 453.3486 453.4739 453.5991 453.7244 453.8496 453.9748 454.1000 454.2251 454.3503 454.4754 454.6005 454.7256 454.8507 454.9758 455.1009 455.2259 455.3509 455.4759 455.6009 455.7259 455.8509 455.9758 456.1008 456.2257 456.3506 456.4755 456.6003 456.7252 456.8500 456.9749 457.0997 457.2245 457.3492 457.4740 457.5988 457.7235 457.8482 457.9729 458.0976 458.2223 458.3469 458.4715 458.5962 458.7208 458.8454 458.9699 459.0945 459.2190 459.3436 459.4681 459.5926 459.7171 459.8415 459.9660 460.0904 460.2148 460.3392 460.4636 460.5880 460.7124 460.8367 460.9610 461.0853 461.2096 461.3339 461.4582 461.5824 461.7067 461.8309 461.9551 462.0793 462.2034 462.3276 462.4517 462.5758 462.7000 462.8240 462.9481 463.0722 463.1962 463.3202 463.4443 463.5683 463.6922 463.8162 463.9402 464.0641 464.1880 464.3119 464.4358 464.5597 464.6835 464.8074 464.9312 465.0550 465.1788 465.3026 465.4263 465.5501 465.6738 465.7975 465.9212 466.0449 466.1686 466.2922 466.4159 466.5395 466.6631 466.7867 466.9102 467.0338 467.1573 467.2809 467.4044 467.5279 467.6514 467.7748 467.8983 468.0217 468.1451 468.2685 468.3919 468.5153 468.6386 468.7619 468.8853 469.0086 469.1319 469.2551 469.3784 469.5016 469.6249 469.7481 469.8713 469.9944 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Azimuth motor temperature [°C], 999=no temperature signal Column 163: Humidity in head sensor [%], -9=no humidity signal Column 164: Pressure in head sensor [hPa], -9=no pressure signal Columns 165-714: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 715-1264: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20210218T171103.9Z 7719.716017 126 1 49.76 2 48.52 177.26 71.35 85.48 0.00 1 0.00 1 0 33 2.719e-03 2.669e-03 1.120e-03 1.103e-03 4.250969e+03 2.258870e+02 4.079418e+02 2.935501e+02 5.412830e+02 278.70 -2.00 20.00 -2.00 445.20 0.00e+00 7.845400e-04 1.212647e-04 2.253419e-06 1.192149e-05 2.971153e-04 278.70 -2.00 20.00 -2.00 454.88 0.00e+00 1.313029e-04 9.978319e-06 8.777802e-07 3.776916e-06 2.460397e-05 225.93 -2.00 2.11 -2.00 434.13 0.00e+00 3.351704e+06 1.585008e+05 6.687259e+04 1.813412e+05 3.905803e+05 260.42 -2.00 11.01 -2.00 458.12 0.00e+00 -2.360228e-01 3.150508e-02 1.739374e-03 6.946820e-03 8.474253e-02 225.32 -2.00 3.43 -2.00 454.28 0.00e+00 -6.996786e-06 4.031186e-06 7.559342e-07 9.091912e-07 1.038094e-05 278.70 -2.00 20.00 -2.00 455.71 0.00e+00 1.507 0.000 397.00 473.00 4 7.8441e+00 1.1808e-03 3.8400e-03 3.1203e-04 2.7679e-03 5.5973e-02 1.3841e-03 8.0381e-04 1.8261e-04 3.4017e-03 -2.2239e-02 8.2039e-04 1.1183e-04 8.0168e-05 1.9963e-03 -2.4559e-04 2.6755e-04 5.2306e-05 2.0250e-05 6.5655e-04 1.7957e-03 1.3546e-04 3.9581e-05 1.0820e-05 3.2964e-04 5.4888e-04 -3.1883e-03 7.7369e-04 3.9934e-05 3.5952e-05 1.7082e-03 -2.3108e-04 1.2545e-05 7.4212e-07 3.0565e-07 2.8553e-05 -1.2279e-04 1.6206e-05 8.8687e-07 3.5665e-07 3.8309e-05 1.2767e-02 -5.3011e-04 3.8420e+00 1.0882e-01 3.4490e-03 2.3292e-03 2.5269e-01 12 9 8 11 36 0 99.92 20.17 2.12 0.01277 0.01813 13 3 1 4 0 3826.780 23.72 20.00 20.17 7.77 30.60 6.0 1024.47 625 -53 -2 99 93 142 5 -208 352 97 299 99 477 136 120 -414 -325 -47 -81 86 -284 87 -166 -94 -725 -441 413 28 -512 -95 104 -121 -141 -229 154 -343 -8 96 -399 139 66 248 7 454 399 -382 -123 38 -340 31 344 571 -629 -10 433 -77 -288 341 -381 -38 -188 -216 -158 256 227 3 -26 -369 -22 332 280 473 46 231 -83 -298 -116 -141 -157 -492 -355 -173 1 -190 62 461 439 83 593 171 760 -113 -185 226 73 -99 -444 427 -33 -109 -317 -270 57 -242 -172 -81 216 -247 366 191 -79 -397 -218 -183 128 -285 -285 187 -480 64 -320 120 -126 -482 77 137 192 571 -111 -34 -44 96 8 -559 -594 -199 84 -466 -27 -205 271 -133 180 461 195 -75 318 -102 1 760 -53 -249 119 -284 -328 499 -123 144 -50 -124 -90 -119 377 138 476 83 -270 117 40 -68 -69 -271 -430 139 126 -127 154 61 -536 432 130 405 -27 -43 275 -161 33 184 -176 146 -9 -163 583 -167 -166 556 148 -389 -157 -56 115 -118 -188 175 34 36 -49 -440 63 32 -273 154 -166 -295 -128 65 181 102 2 341 472 491 4 512 -7 406 42 106 631 -219 118 70 -152 570 239 -186 388 371 512 -383 482 379 410 -163 222 554 295 511 -56 -118 68 251 -365 -179 -366 3 164 620 37 396 -174 -539 292 -352 -721 -191 -173 -372 307 -261 -694 -222 209 -193 238 -660 -36 -278 -421 -148 -46 -30 -250 122 -217 -413 237 -724 -342 -119 -79 -1 -31 -121 -412 -527 301 110 -130 -58 25 -97 -207 -211 58 423 -8 -72 3 257 345 -326 -236 133 -434 320 255 -269 322 29 -53 -4 -192 -252 151 -504 -147 152 58 -43 448 -36 368 87 -237 -707 -140 140 66 -41 -176 -146 266 -59 5 -31 295 96 -249 -381 104 -232 -216 23 12 -104 94 1 -108 -81 413 -235 33 791 272 -182 -142 121 -67 -95 331 358 -353 243 93 -264 -9 343 -173 172 -33 289 -598 -134 301 -543 -16 163 -74 -155 -214 83 -75 -177 -258 201 522 512 135 45 38 232 -115 131 111 241 483 102 110 257 193 117 560 -144 153 -302 -105 610 120 -4 268 -30 251 222 144 204 -37 169 83 -175 -328 -137 -201 -181 -125 61 -278 -506 203 -374 -422 -202 119 145 -16 48 -117 171 -65 -477 -194 78 -385 514 29 -132 -102 52 -207 292 111 -119 -98 9 -86 144 243 -236 -75 -226 -106 -246 159 -138 118 -36 -3 -81 201 187 -92 232 -109 380 -50 -109 105 248 -369 -287 556 40 55 138 237 203 25 -25 273 -245 -159 -118 -102 -175 211 -315 -195 -266 -174 -38 207 -224 -305 278 230 193 -66 -309 360 17 452 -550 -221 59 -224 81 -28 67 27 -104 492 22 -69 394 -189 -21 124 -136 53 152 94 -168 229 114 259 -384 -323 -128 -62 30 578 -50 -2 90 84 128 5 -196 338 94 290 96 456 131 116 -405 -321 -46 -79 85 -283 85 -162 -87 -673 -406 381 27 -510 -96 106 -120 -137 -214 137 -307 -8 94 -395 137 65 240 6 435 387 -362 -118 36 -312 29 318 556 -609 -9 413 -76 -280 327 -364 -36 -184 -213 -160 260 229 3 -27 -387 -23 347 288 472 46 226 -80 -274 -104 -122 -137 -455 -341 -169 1 -193 63 462 450 87 626 180 784 -116 -189 232 75 -102 -455 431 -33 -110 -313 -265 56 -240 -178 -84 226 -254 368 186 -79 -389 -219 -188 131 -291 -286 184 -469 62 -316 121 -127 -498 80 143 198 578 -112 -35 -44 93 8 -528 -564 -192 82 -462 -26 -203 267 -130 173 443 189 -74 311 -103 1 741 -52 -235 113 -268 -304 473 -121 142 -51 -124 -91 -121 380 138 479 83 -267 117 40 -68 -67 -259 -389 120 109 -117 148 60 -526 424 124 376 -25 -41 263 -157 32 181 -172 143 -9 -150 550 -155 -157 531 143 -376 -148 -52 105 -110 -183 171 34 35 -48 -399 55 28 -239 137 -152 -281 -120 61 174 97 2 317 429 445 3 453 -6 359 37 94 543 -182 94 53 -117 438 180 -144 292 272 373 -292 382 314 369 -154 217 559 299 510 -54 -107 60 220 -329 -169 -356 3 162 605 36 369 -155 -469 239 -291 -611 -173 -163 -358 301 -249 -669 -208 191 -178 225 -626 -34 -269 -414 -147 -46 -30 -248 119 -215 -403 227 -689 -317 -112 -74 -1 -30 -115 -387 -475 261 94 -113 -51 22 -91 -190 -195 54 400 -8 -70 3 247 325 -300 -217 121 -399 290 242 -260 317 29 -52 -4 -184 -244 146 -499 -146 149 55 -43 429 -35 355 85 -228 -673 -135 134 62 -40 -174 -144 258 -57 5 -30 285 94 -245 -373 100 -223 -200 21 11 -94 86 1 -99 -75 390 -221 32 740 256 -175 -135 116 -67 -92 321 350 -339 233 88 -248 -8 336 -171 167 -32 275 -575 -128 289 -527 -16 160 -72 -152 -212 83 -76 -182 -266 206 531 517 135 45 37 233 -115 133 112 244 486 101 107 249 182 111 527 -137 146 -293 -100 591 119 -4 269 -31 252 227 147 205 -36 170 83 -176 -331 -139 -205 -182 -128 64 -296 -542 214 -392 -437 -213 127 151 -16 50 -127 185 -69 -513 -212 84 -408 544 30 -138 -107 55 -224 318 121 -131 -107 9 -92 154 267 -261 -83 -251 -118 -275 179 -153 132 -41 -3 -92 232 215 -106 266 -125 437 -58 -127 122 289 -433 -337 648 47 65 162 276 236 29 -29 319 -286 -185 -138 -120 -205 244 -360 -226 -307 -202 -44 239 -261 -356 322 268 227 -79 -374 430 20 534 -636 -247 68 -257 92 -32 79 31 -122 574 26 -82 460 -222 -25 147 -159 62 178 109 -196 272 136 302 -452 -379 -148 -72 35