File name: Pandora241s1_Jeonju_20260406_L2Fit_fwvt1c3d20241002p1-8.txt File generation date: 20260406T153900.4Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c3p1-8 Local principal investigator: Mijung Song Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 241 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora241_OF_v2d20230410.txt Instrument calibration file used: Pandora241s1_CF_v3d20241002.txt Level 1 file used: Pandora241s1_Jeonju_20260406_L1_smca1c3d20241002p1-8.txt Full location name: Jeonbuk National University/Jeonju Short location name: Jeonju Country of location: Korea, Republic of Location latitude [deg]: 35.8466 Location longitude [deg]: 127.1307 Location altitude [m]: 40 Local noon date: 20260406 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 2, but final AnaFld. First and last pixel inside fitting window: 1612 1762 Nominal wavelengths inside fitting window [nm]: 492.0688 492.1895 492.3103 492.4310 492.5517 492.6723 492.7930 492.9136 493.0343 493.1549 493.2755 493.3960 493.5166 493.6371 493.7577 493.8782 493.9987 494.1191 494.2396 494.3600 494.4804 494.6008 494.7212 494.8416 494.9619 495.0823 495.2026 495.3229 495.4431 495.5634 495.6836 495.8039 495.9241 496.0443 496.1644 496.2846 496.4047 496.5249 496.6450 496.7651 496.8851 497.0052 497.1252 497.2452 497.3652 497.4852 497.6052 497.7251 497.8451 497.9650 498.0849 498.2048 498.3246 498.4445 498.5643 498.6841 498.8039 498.9237 499.0434 499.1632 499.2829 499.4026 499.5223 499.6419 499.7616 499.8812 500.0008 500.1204 500.2400 500.3596 500.4791 500.5987 500.7182 500.8377 500.9571 501.0766 501.1960 501.3155 501.4349 501.5543 501.6736 501.7930 501.9123 502.0316 502.1509 502.2702 502.3895 502.5087 502.6280 502.7472 502.8664 502.9855 503.1047 503.2238 503.3430 503.4621 503.5812 503.7002 503.8193 503.9383 504.0574 504.1764 504.2953 504.4143 504.5333 504.6522 504.7711 504.8900 505.0089 505.1277 505.2466 505.3654 505.4842 505.6030 505.7218 505.8405 505.9593 506.0780 506.1967 506.3154 506.4340 506.5527 506.6713 506.7899 506.9085 507.0271 507.1456 507.2642 507.3827 507.5012 507.6197 507.7382 507.8566 507.9751 508.0935 508.2119 508.3303 508.4486 508.5670 508.6853 508.8036 508.9219 509.0402 509.1584 509.2767 509.3949 509.5131 509.6313 509.7495 509.8676 509.9857 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20260406T073849.0Z 9592.318623 7 1 2.98 2 63.00 257.79 163.80 57.58 0.00 1 0.00 1 0 36 7.213e-03 7.222e-03 2.868e-03 2.863e-03 1.618129e+03 1.772382e+02 9.559524e+01 -6.000000e+00 4.231528e+02 282.76 -2.00 20.00 -2.00 505.22 0.00e+00 9.720240e-04 8.117421e-05 7.297725e-05 -6.000000e+00 2.074245e-04 282.76 -2.00 20.00 -2.00 500.28 0.00e+00 1.219887e-01 5.893395e-02 1.114149e-02 -6.000000e+00 1.482907e-01 228.44 -2.00 3.41 -2.00 501.90 0.00e+00 2.190 0.000 489.00 513.00 1 6.0800e+00 4.5184e-03 3.6909e-03 -6.0000e+00 1.1381e-02 7.0920e-04 1.1771e-03 2.4021e-04 -6.0000e+00 2.9454e-03 3.2077e-03 -2.3538e-02 3.2400e-04 3.2908e-05 -6.0000e+00 8.6714e-04 -1.5529e-01 -2.0710e-04 12 9 9 12 1 1 999.00 24.61 2.30 -0.15529 -0.31856 1 18 1 2 0 1485.760 20.01 24.61 22.46 33.25 32.00 1.1 986.46 900000 -1022 -1522 -2246 -1419 -373 -143 688 410 1093 1265 1251 881 666 335 -259 -339 -494 -719 -70 224 940 460 303 182 359 177 552 322 433 477 -391 -904 -1992 -1478 -703 399 646 168 358 -141 -406 -950 -557 20 1258 548 1365 1065 618 376 259 28 -772 -1669 -1372 -949 -70 -815 873 849 588 -164 103 572 690 980 388 246 166 2 -161 -456 -836 -1284 142 118 575 148 254 -324 -614 -767 -420 -486 -327 -197 -17 -161 207 -124 -711 152 3 714 689 1236 973 774 1051 460 -797 -1063 -1731 -1130 -606 739 753 896 -174 -436 -557 -508 -238 -114 187 -266 98 481 764 761 891 457 -245 -595 -68 -7 -74 -66 -77 -302 324 1002 254 667 -72 -1217 -820 -856 -128 -556 51 25 -65 478 64 438 357 -36 -583 -531 900000 -1033 -1529 -2262 -1418 -380 -148 712 429 1151 1338 1319 923 689 347 -267 -345 -503 -738 -73 232 975 485 321 192 377 187 581 340 453 497 -402 -925 -2035 -1508 -716 413 671 177 375 -146 -420 -982 -574 20 1292 565 1405 1100 638 389 263 29 -766 -1660 -1351 -938 -70 -818 879 865 595 -167 105 582 702 992 392 249 166 2 -159 -449 -821 -1269 139 115 562 145 248 -314 -593 -739 -404 -471 -319 -191 -17 -159 201 -121 -701 150 3 701 684 1223 960 765 1016 444 -762 -1005 -1642 -1077 -580 717 735 879 -172 -428 -544 -497 -231 -112 184 -265 98 483 768 763 887 452 -241 -580 -67 -7 -73 -64 -75 -293 315 964 245 640 -69 -1165 -780 -810 -122 -534 49 24 -64 467 63 431 352 -35 -568 -515 SQ 20260406T080043.5Z 9592.333836 22 1 26.51 2 67.36 261.37 160.08 66.82 0.00 1 0.00 1 0 36 7.126e-03 7.123e-03 2.166e-03 2.159e-03 2.041929e+03 1.363513e+02 1.321541e+02 -6.000000e+00 4.180672e+02 282.76 -2.00 20.00 -2.00 505.20 0.00e+00 1.059651e-03 6.102422e-05 7.715068e-05 -6.000000e+00 2.051312e-04 282.76 -2.00 20.00 -2.00 500.19 0.00e+00 2.166474e-01 4.498340e-02 1.457724e-02 -6.000000e+00 1.471466e-01 228.44 -2.00 3.41 -2.00 501.81 0.00e+00 2.577 0.000 489.00 513.00 1 7.9754e+00 3.4446e-03 4.2855e-03 -6.0000e+00 1.1278e-02 9.1356e-03 9.0402e-04 3.3923e-04 -6.0000e+00 2.9444e-03 4.5219e-04 -1.8535e-02 2.5024e-04 3.8018e-05 -6.0000e+00 8.5932e-04 -1.5423e-01 -3.7769e-04 12 8 8 10 0 0 99.27 25.06 2.22 -0.15423 -0.28279 7 7 1 2 0 3785.930 20.00 25.06 23.67 34.00 33.00 1.0 991.70 900000 900000 -2040 -1713 -846 -356 235 650 808 1047 1054 1292 651 316 110 -59 -870 -668 -581 -394 115 759 579 412 224 266 275 581 587 676 199 -376 -1298 -1344 -1556 -587 136 547 761 -14 -272 -540 -175 -321 -110 606 398 695 739 915 739 87 -626 -462 -1609 -1765 -1547 -714 -82 896 622 79 39 459 154 841 590 469 281 394 122 -419 -231 -341 -318 209 802 150 298 -390 -473 -693 -1038 -735 -302 -370 -6 -507 502 -100 -326 -596 -416 65 331 1024 1116 1194 345 1188 444 -728 -1672 -1698 -724 -398 423 1064 878 -82 -808 -1074 -711 -332 300 444 546 521 313 1008 429 838 24 66 -414 -570 -476 139 171 267 173 325 464 472 91 -358 -1299 -1150 -799 -645 143 -119 233 249 21 399 715 501 331 -290 -456 900000 900000 -2053 -1713 -853 -367 249 677 857 1124 1136 1384 694 333 115 -60 -894 -683 -597 -411 122 813 628 450 245 282 292 616 622 710 213 -397 -1352 -1385 -1615 -615 140 574 801 -15 -286 -562 -180 -332 -114 631 420 735 781 959 766 89 -629 -468 -1618 -1766 -1559 -705 -82 908 639 81 41 474 160 869 609 482 285 394 120 -411 -224 -330 -308 203 780 147 291 -378 -454 -661 -990 -701 -288 -356 -6 -498 492 -98 -323 -575 -402 63 324 1003 1095 1162 333 1154 425 -691 -1579 -1600 -684 -372 402 1023 851 -80 -786 -1042 -690 -324 295 442 531 511 309 991 423 818 23 63 -395 -542 -452 135 162 252 163 306 434 453 87 -338 -1227 -1084 -757 -600 134 -114 224 241 20 390 698 489 321 -279 -432 SQ 20260406T082946.4Z 9592.354009 37 1 30.60 2 73.21 265.87 154.79 75.40 0.00 1 0.00 1 0 36 7.202e-03 7.208e-03 1.596e-03 1.592e-03 2.781887e+03 1.032052e+02 1.620268e+02 -6.000000e+00 4.225294e+02 282.76 -2.00 20.00 -2.00 505.22 0.00e+00 1.776699e-03 4.532229e-05 1.195997e-04 -6.000000e+00 2.073571e-04 282.76 -2.00 20.00 -2.00 500.29 0.00e+00 3.481016e-01 3.318713e-02 2.524529e-02 -6.000000e+00 1.487735e-01 228.44 -2.00 3.41 -2.00 501.89 0.00e+00 3.407 0.001 489.00 513.00 1 7.4707e+00 2.5425e-03 6.0062e-03 -6.0000e+00 1.1402e-02 -1.8063e-03 6.6409e-04 5.2060e-04 -6.0000e+00 2.9786e-03 6.5112e-04 -1.8243e-02 1.8497e-04 5.5851e-05 -6.0000e+00 8.6830e-04 -1.3482e-01 -5.3562e-04 12 8 8 10 0 0 99.87 25.21 2.18 -0.13482 -0.26136 11 11 1 2 0 2781.180 20.00 25.21 23.98 34.00 33.00 0.9 991.88 900000 900000 -2123 -1869 -1191 -513 338 268 952 1284 1366 1318 974 178 238 -444 -498 -699 -470 -658 447 544 747 686 260 310 390 533 628 818 12 -165 -1494 -1657 -1516 -654 80 677 662 55 -145 -375 -634 -191 -473 405 437 679 755 753 803 508 -550 -887 -1856 -2041 -1452 -608 159 598 548 396 392 328 778 821 768 825 428 113 -52 -331 -797 -493 13 43 412 623 166 -211 -671 -822 -909 -666 -496 -313 -213 -191 -128 110 -192 -526 -585 -273 368 664 877 1035 874 1023 -157 -632 -1333 -1249 -900 -542 304 842 663 93 -574 -692 -386 -252 427 294 271 713 468 798 510 888 40 -394 -624 -535 27 -105 220 305 306 369 587 359 -110 -465 -971 -948 -616 -400 -174 77 270 18 349 296 555 542 -104 -111 -659 900000 900000 -2113 -1850 -1190 -524 341 279 1002 1365 1459 1403 1029 187 246 -456 -507 -711 -480 -684 469 563 779 719 275 327 414 565 665 858 12 -168 -1509 -1709 -1522 -664 83 710 700 59 -153 -392 -661 -198 -497 425 463 702 781 774 840 523 -559 -883 -1831 -2005 -1430 -607 161 616 554 403 399 335 792 837 781 832 428 112 -53 -330 -791 -486 13 42 409 602 161 -208 -657 -798 -880 -646 -483 -298 -204 -184 -124 107 -188 -516 -577 -270 366 665 878 1027 855 980 -149 -590 -1234 -1153 -838 -515 294 826 637 90 -552 -664 -371 -244 417 291 272 716 473 809 504 893 40 -392 -615 -524 27 -102 215 298 299 359 568 346 -105 -441 -917 -894 -584 -384 -165 73 261 17 342 292 546 534 -102 -107 -632 SQ 20260406T085638.0Z 9592.372662 52 1 26.39 2 78.64 269.87 149.73 81.27 0.00 1 0.00 1 0 50 7.554e-03 7.516e-03 1.182e-03 1.180e-03 3.659719e+03 7.712695e+01 2.149206e+02 -6.000000e+00 4.431674e+02 282.76 -2.00 20.00 -2.00 505.26 0.00e+00 2.318590e-03 3.356071e-05 1.527451e-04 -6.000000e+00 2.174068e-04 282.76 -2.00 20.00 -2.00 500.45 0.00e+00 4.737730e-01 2.435470e-02 3.469940e-02 -6.000000e+00 1.559304e-01 228.44 -2.00 3.41 -2.00 502.03 0.00e+00 4.906 0.002 489.00 513.00 1 6.6191e+00 1.8635e-03 8.3999e-03 -6.0000e+00 1.1953e-02 -1.9340e-02 4.8615e-04 7.4009e-04 -6.0000e+00 3.1188e-03 1.2095e-03 -1.9668e-02 1.3705e-04 7.1521e-05 -6.0000e+00 9.1121e-04 -1.1411e-01 -5.8414e-04 12 8 8 10 0 0 92.31 25.24 2.31 -0.11411 -0.25054 9 9 1 2 0 2932.150 19.99 25.24 23.15 34.00 33.00 0.9 986.59 900000 900000 -1978 -2103 -1196 -403 153 594 1170 1156 1594 1333 745 373 172 -190 -721 -730 -757 -403 387 845 553 218 54 181 581 742 865 855 329 -314 -1486 -1951 -1542 -576 71 612 624 196 -69 -448 -623 -243 182 260 384 1064 883 959 664 163 -303 -1017 -1790 -1831 -1398 -605 114 698 468 402 293 236 769 852 897 466 344 172 186 -446 -821 -568 -625 -244 294 317 0 -335 -531 -753 -789 -681 -356 -534 -363 -269 -25 -123 -487 -317 -353 -172 418 1009 1263 1210 707 1011 -54 -943 -1327 -1538 -1095 -561 435 539 401 -299 -639 -721 -405 -248 438 564 550 675 682 909 844 1025 480 -93 -558 -740 13 149 340 351 166 553 519 287 -40 -674 -925 -930 -807 -510 -305 266 85 359 379 169 487 422 268 -196 -994 900000 900000 -1916 -2037 -1168 -402 153 605 1210 1183 1634 1364 758 385 175 -192 -726 -734 -766 -413 392 867 576 228 57 186 599 766 890 874 341 -320 -1502 -1960 -1552 -586 72 630 646 203 -71 -459 -638 -248 187 269 402 1115 907 1002 687 167 -304 -1003 -1791 -1823 -1367 -600 115 714 474 410 299 242 785 871 915 474 347 171 187 -446 -815 -560 -618 -242 293 309 0 -331 -520 -732 -766 -661 -347 -513 -351 -262 -25 -121 -481 -313 -351 -171 410 993 1242 1181 699 976 -52 -889 -1268 -1436 -1031 -538 425 525 394 -294 -628 -707 -397 -246 437 558 550 680 692 924 859 1036 483 -92 -554 -732 13 147 334 346 164 543 509 280 -39 -649 -886 -891 -779 -499 -302 261 85 358 381 172 493 427 270 -195 -982 SQ 20260406T090423.9Z 9592.378054 56 1 30.73 2 80.21 271.00 148.25 82.74 0.00 1 0.00 1 0 43 8.198e-03 8.130e-03 8.179e-04 8.173e-04 3.983131e+03 5.334792e+01 2.294595e+02 -6.000000e+00 4.808538e+02 282.76 -2.00 20.00 -2.00 505.27 0.00e+00 2.758173e-03 2.327699e-05 1.724399e-04 -6.000000e+00 2.358053e-04 282.76 -2.00 20.00 -2.00 500.50 0.00e+00 4.963536e-01 1.672159e-02 3.866831e-02 -6.000000e+00 1.686486e-01 228.44 -2.00 3.41 -2.00 502.08 0.00e+00 5.619 0.003 489.00 513.00 1 5.9835e+00 1.2797e-03 9.5674e-03 -6.0000e+00 1.2941e-02 -3.4997e-02 3.3132e-04 8.2325e-04 -6.0000e+00 3.3543e-03 2.0439e-03 -2.1004e-02 9.2580e-05 7.4812e-05 -6.0000e+00 9.8491e-04 -7.9691e-02 -7.5987e-04 12 8 8 10 0 0 85.11 25.25 2.88 -0.07969 -0.22538 15 15 1 2 0 2048.470 20.00 25.25 23.10 34.00 33.00 1.0 986.26 900000 -1403 -2153 -2041 -1360 -429 203 636 1125 1287 1509 1365 965 523 245 -185 -638 -683 -705 -251 334 888 671 431 374 361 610 759 939 823 400 -445 -1551 -1993 -1635 -764 103 741 584 121 -174 -532 -493 -458 -61 292 660 971 957 997 794 294 -451 -1100 -1765 -2051 -1477 -711 16 629 534 385 535 636 822 989 1017 794 276 206 -160 -351 -688 -713 -481 -205 260 469 319 -365 -826 -874 -962 -948 -635 -610 -378 -320 -202 -68 -498 -349 -276 80 371 1217 1426 1420 930 888 -13 -755 -1498 -1630 -1333 -692 197 531 386 -93 -652 -787 -570 -326 236 506 535 820 838 1129 1075 1014 402 47 -419 -317 -186 248 364 528 315 416 628 385 32 -768 -1175 -1202 -1113 -455 -169 -8 -31 279 251 207 363 519 229 -282 -868 900000 -1370 -2069 -1957 -1318 -425 202 645 1135 1316 1548 1397 981 527 244 -183 -628 -685 -698 -252 339 896 685 444 387 374 633 774 955 850 409 -449 -1548 -1977 -1627 -769 103 755 600 125 -178 -544 -502 -467 -62 301 674 997 985 1020 805 300 -454 -1088 -1727 -2003 -1449 -708 16 635 545 395 550 654 832 1001 1028 814 281 208 -159 -347 -675 -696 -469 -201 257 464 315 -358 -804 -844 -927 -915 -615 -596 -371 -317 -198 -67 -490 -344 -272 79 371 1220 1430 1413 916 857 -13 -724 -1427 -1552 -1282 -665 193 519 381 -92 -645 -778 -564 -326 234 507 543 836 844 1141 1088 1023 404 48 -423 -318 -187 248 366 530 311 418 627 384 31 -757 -1153 -1181 -1102 -446 -168 -8 -31 281 255 212 372 529 233 -285 -866 SQ 20260406T090904.7Z 9592.381304 59 1 31.19 2 81.16 271.69 147.36 83.58 0.00 1 0.00 1 0 43 8.310e-03 8.241e-03 1.068e-03 1.066e-03 4.453799e+03 7.037823e+01 2.520045e+02 -6.000000e+00 4.874662e+02 282.76 -2.00 20.00 -2.00 505.27 0.00e+00 2.903461e-03 3.033912e-05 1.840244e-04 -6.000000e+00 2.390098e-04 282.76 -2.00 20.00 -2.00 500.49 0.00e+00 5.856098e-01 2.180455e-02 4.259293e-02 -6.000000e+00 1.709250e-01 228.44 -2.00 3.41 -2.00 502.07 0.00e+00 6.155 0.004 489.00 513.00 1 6.3858e+00 1.6684e-03 1.0438e-02 -6.0000e+00 1.3116e-02 -3.6317e-02 4.3142e-04 9.1322e-04 -6.0000e+00 3.3981e-03 1.2544e-03 -2.1325e-02 1.2054e-04 7.9983e-05 -6.0000e+00 9.9877e-04 -9.4243e-02 -6.4029e-04 12 8 8 10 0 0 56.98 25.25 3.08 -0.09424 -0.24216 11 11 1 2 0 2834.620 20.00 25.25 22.94 34.00 33.25 1.0 985.65 900000 -1432 -2078 -2201 -1493 -454 324 760 1277 1409 1565 1261 886 642 191 -240 -691 -653 -845 -291 192 658 627 424 264 365 615 652 1027 889 527 -279 -1538 -2004 -1565 -640 226 719 541 78 -110 -542 -442 -537 -96 274 573 1001 1133 987 809 222 -550 -1034 -1994 -1948 -1611 -661 143 590 673 556 422 426 470 862 814 858 420 315 -215 -417 -550 -743 -616 -21 399 623 325 -189 -773 -929 -1122 -942 -725 -680 -435 -98 -54 108 -471 -154 -576 -46 609 1050 1414 1450 930 924 155 -784 -1594 -1514 -1474 -576 62 796 452 -102 -684 -818 -656 -419 174 385 611 856 699 1085 1247 953 460 -205 -376 -353 -57 -66 335 388 337 570 527 353 -101 -795 -1236 -1046 -966 -504 -287 203 331 153 382 342 421 242 136 -290 -943 900000 -1379 -2021 -2139 -1431 -444 324 757 1293 1445 1612 1298 906 649 192 -238 -683 -644 -841 -293 192 665 641 437 273 378 639 680 1067 919 539 -281 -1538 -1992 -1560 -645 232 732 556 80 -113 -552 -449 -547 -98 283 597 1024 1159 1007 836 227 -554 -1023 -1956 -1901 -1583 -658 145 593 684 568 433 438 486 888 838 877 426 316 -214 -411 -538 -724 -601 -21 392 614 319 -184 -750 -895 -1080 -907 -701 -662 -426 -97 -54 107 -461 -154 -567 -46 604 1047 1406 1431 907 904 150 -747 -1511 -1431 -1412 -561 60 785 451 -103 -685 -800 -644 -415 174 389 611 862 709 1103 1268 968 464 -206 -375 -349 -57 -65 332 386 335 565 521 348 -99 -775 -1201 -1015 -946 -499 -288 202 333 155 390 351 433 249 139 -294 -948