File name: Pandora198s1_Kobe_20240120_L2Fit_ffus5c1d20220209p1-8.txt File generation date: 20240120T151457.2Z Data description: Level 2 spectral fitting results file Data file version: ffus5c1p1-8 Local principal investigator: Kazuyo Yamaji Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 198 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora198_OF_v4d20210227.txt Instrument calibration file used: Pandora198s1_CF_v1d20220209.txt Level 1 file used: Pandora198s1_Kobe_20240120_L1_smca1c1d20220209p1-8.txt Full location name: Kobe University Short location name: Kobe Country of location: Japan Location latitude [deg]: 34.7190 Location longitude [deg]: 135.2900 Location altitude [m]: 23 Local noon date: 20240120 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 325 590 Nominal wavelengths inside fitting window [nm]: 322.5462 322.6857 322.8252 322.9648 323.1043 323.2438 323.3833 323.5227 323.6622 323.8016 323.9411 324.0805 324.2199 324.3593 324.4987 324.6381 324.7775 324.9169 325.0562 325.1956 325.3349 325.4742 325.6135 325.7528 325.8921 326.0314 326.1706 326.3099 326.4491 326.5883 326.7276 326.8668 327.0060 327.1451 327.2843 327.4235 327.5626 327.7018 327.8409 327.9800 328.1191 328.2582 328.3973 328.5364 328.6754 328.8145 328.9535 329.0925 329.2315 329.3705 329.5095 329.6485 329.7875 329.9264 330.0654 330.2043 330.3432 330.4822 330.6211 330.7599 330.8988 331.0377 331.1765 331.3154 331.4542 331.5930 331.7319 331.8706 332.0094 332.1482 332.2870 332.4257 332.5645 332.7032 332.8419 332.9806 333.1193 333.2580 333.3967 333.5353 333.6740 333.8126 333.9512 334.0899 334.2285 334.3671 334.5056 334.6442 334.7828 334.9213 335.0598 335.1984 335.3369 335.4754 335.6139 335.7523 335.8908 336.0293 336.1677 336.3061 336.4446 336.5830 336.7214 336.8597 336.9981 337.1365 337.2748 337.4132 337.5515 337.6898 337.8281 337.9664 338.1047 338.2429 338.3812 338.5194 338.6577 338.7959 338.9341 339.0723 339.2105 339.3487 339.4868 339.6250 339.7631 339.9013 340.0394 340.1775 340.3156 340.4537 340.5917 340.7298 340.8678 341.0059 341.1439 341.2819 341.4199 341.5579 341.6959 341.8339 341.9718 342.1097 342.2477 342.3856 342.5235 342.6614 342.7993 342.9372 343.0750 343.2129 343.3507 343.4885 343.6263 343.7641 343.9019 344.0397 344.1775 344.3152 344.4530 344.5907 344.7284 344.8661 345.0038 345.1415 345.2792 345.4169 345.5545 345.6922 345.8298 345.9674 346.1050 346.2426 346.3802 346.5177 346.6553 346.7928 346.9304 347.0679 347.2054 347.3429 347.4804 347.6178 347.7553 347.8928 348.0302 348.1676 348.3050 348.4424 348.5798 348.7172 348.8546 348.9919 349.1293 349.2666 349.4039 349.5412 349.6785 349.8158 349.9531 350.0903 350.2276 350.3648 350.5020 350.6393 350.7765 350.9136 351.0508 351.1880 351.3251 351.4623 351.5994 351.7365 351.8736 352.0107 352.1478 352.2849 352.4219 352.5590 352.6960 352.8330 352.9700 353.1070 353.2440 353.3810 353.5180 353.6549 353.7918 353.9288 354.0657 354.2026 354.3395 354.4764 354.6132 354.7501 354.8869 355.0237 355.1606 355.2974 355.4342 355.5709 355.7077 355.8445 355.9812 356.1179 356.2547 356.3914 356.5281 356.6647 356.8014 356.9381 357.0747 357.2114 357.3480 357.4846 357.6212 357.7578 357.8944 358.0309 358.1675 358.3040 358.4405 358.5770 358.7135 358.8500 358.9865 359.1230 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20240120T020937.2Z 8785.090014 250 1 49.02 2 56.79 163.13 103.48 52.51 0.00 1 0.00 1 7 257 3.759e-02 3.738e-02 1.677e-04 1.563e-04 5.933198e-05 5.496090e-08 9.003279e-07 3.825729e-07 1.302702e-05 224.46 -2.00 3.38 -2.00 340.61 0.00e+00 -2.297360e-02 1.705550e-05 9.669712e-04 1.551485e-05 4.097875e-03 280.70 -2.00 20.00 -2.00 338.28 0.00e+00 1.650059e-03 2.299945e-06 2.313587e-05 2.556228e-05 5.961895e-04 280.70 -2.00 20.00 -2.00 346.60 0.00e+00 -5.683710e-03 6.650016e-06 4.148560e-04 6.343737e-05 1.732377e-03 280.70 -2.00 20.00 -2.00 345.36 0.00e+00 -3.664109e+07 1.547813e+04 1.318921e+06 2.008651e+05 3.964105e+06 262.12 -2.00 10.87 -2.00 352.32 0.00e+00 -6.566586e-02 2.167217e-04 4.054345e-03 1.027355e-03 4.447133e-02 224.46 -2.00 3.38 -2.00 330.64 0.00e+00 1.569066e-01 2.275846e-04 5.017361e-03 7.770047e-05 3.805182e-02 280.70 -2.00 20.00 -2.00 328.74 0.00e+00 1.820 0.000 319.50 362.20 4 3.2393e+00 5.2951e-04 3.3364e-02 2.4015e-03 1.3471e-01 -2.8578e-01 9.4653e-05 4.7989e-03 2.8147e-04 2.2267e-02 -2.6799e-01 1.3335e-04 9.3788e-03 3.7720e-04 3.4083e-02 -1.5464e-01 6.2846e-05 2.3889e-03 6.9415e-05 1.4563e-02 3.0611e-01 1.2010e-04 8.2457e-03 2.2729e-04 3.0608e-02 9.2329e-02 -1.5447e+00 4.5107e-04 2.2652e-02 6.7317e-04 1.1115e-01 -3.1640e-03 2.8717e-06 3.2343e-05 1.5911e-06 7.3274e-04 -3.0428e-02 0.0000e+00 3.1785e+01 1.2716e-02 2.6886e-01 8.5255e-03 3.1716e+00 12 10 8 10 0 0 99.97 16.05 0.37 -0.03043 -0.06948 1173 277 1 5 0 41.390 21.27 15.02 16.05 19.16 20.3 983.62 -3348 1531 5741 5624 3480 1231 1026 1071 -121 -1678 -3032 -3733 -4515 -4998 -5071 -3352 -38 2899 2889 1452 715 1904 4061 4771 4806 4065 4634 5470 5438 3905 1979 489 801 1005 -259 -2354 -4092 -2407 334 1922 -186 -4318 -7755 -8764 -8344 -7932 -7157 -6463 -4865 -2606 -133 1326 1442 700 135 363 1591 1861 759 -891 -1890 -1065 821 2399 2628 1429 -614 -1613 -1331 489 1388 1114 14 366 1375 1376 219 -2038 -2676 -1105 1190 1572 1033 728 613 367 450 1758 4306 7641 9339 8474 6558 3800 928 218 1807 4314 4695 1371 -2821 -4632 -3708 -1249 1280 2931 3604 1851 -328 -1870 -1136 1125 2027 584 -1609 -2598 -2772 -2889 -3103 -2669 -1046 140 342 -31 -868 -934 -250 324 -50 -987 -2126 -3776 -6031 -8273 -9902 -9418 -7498 -5936 -5866 -6356 -6135 -3954 -963 2213 4689 6064 6519 6935 7954 8917 9137 7054 3435 -254 -1400 -1324 -1732 -3831 -4585 -3474 -1540 528 2367 4103 4993 4371 2404 1127 1174 2498 2714 1316 647 1471 3054 3283 2044 -272 -1075 -352 1118 1154 -396 -2068 -2044 61 2736 3184 853 -2342 -4100 -4182 -4832 -6637 -7955 -6973 -3848 -1295 128 760 1338 2971 4281 4338 3309 1746 519 907 2544 2568 703 -1773 -3541 -4402 -4672 -4515 -4556 -4234 -5014 -5972 -5724 -3673 -1304 147 535 383 622 1314 2434 2791 3084 2768 2627 2140 1745 566 305 828 1343 1371 1431 2365 2888 1687 242 15 803 1163 660 790 2235 4368 5163 3903 2011 798 -537 -1208 -4058 -8143 -10548 -8251 -3395 412 2315 4641 -1761 808 3047 3018 1899 685 581 618 -71 -1002 -1847 -2322 -2866 -3228 -3327 -2226 -26 1959 1976 927 467 1274 2786 3352 3446 2966 3422 4077 4083 2960 1515 379 625 790 -205 -1873 -3283 -1943 271 1564 -152 -3559 -6438 -7321 -7013 -6734 -6147 -5640 -4312 -2342 -120 1210 1325 647 125 336 1464 1700 689 -808 -1725 -977 757 2217 2431 1324 -572 -1511 -1250 458 1297 1041 14 345 1300 1305 208 -1935 -2537 -1044 1117 1475 973 692 588 355 404 1581 4180 7371 8994 8212 5930 3467 849 197 1737 4069 4382 1287 -2693 -4489 -3610 -1207 1224 2792 3450 1801 -300 -1742 -1067 1055 1896 548 -1528 -2506 -2712 -2852 -3081 -2648 -1034 138 340 -31 -887 -972 -263 342 -53 -1037 -2222 -3938 -6292 -8648 -10369 -9851 -7822 -6200 -6161 -6749 -6596 -4271 -1038 2369 4993 6453 6973 7472 8601 9660 9877 7608 3687 -271 -1472 -1363 -1751 -3840 -4616 -3549 -1604 561 2551 4466 5464 4798 2637 1231 1276 2691 2910 1417 705 1623 3409 3445 2159 -289 -1137 -369 1242 1272 -408 -2152 -2154 65 2926 3414 919 -2537 -4456 -4536 -5227 -7153 -8594 -7589 -4226 -1442 145 876 1571 3525 5089 5151 3916 2057 608 1057 2951 2990 829 -2126 -4024 -5026 -5300 -5048 -5029 -4969 -5534 -6696 -6546 -4271 -1532 174 635 458 749 1586 2941 3382 3748 3372 3212 2625 2139 692 371 999 1604 1624 1689 2791 3416 1999 286 17 919 1301 723 852 2405 4719 5637 4327 2253 891 -592 -1305 -4298 -8518 -10975 -8610 -3578 442 2393 4936 SS 20240120T021902.4Z 8785.096556 253 1 49.87 2 56.27 165.71 101.97 54.02 0.00 1 0.00 1 7 257 3.754e-02 3.734e-02 9.983e-05 9.404e-05 5.875094e-05 3.287117e-08 8.816484e-07 3.825611e-07 1.301731e-05 224.46 -2.00 3.38 -2.00 340.44 0.00e+00 -2.261251e-02 1.020794e-05 9.559628e-04 1.571426e-05 4.096464e-03 280.70 -2.00 20.00 -2.00 338.08 0.00e+00 1.636936e-03 1.373708e-06 2.339866e-05 2.556371e-05 5.950459e-04 280.70 -2.00 20.00 -2.00 346.46 0.00e+00 -5.555423e-03 3.983912e-06 3.985438e-04 6.340398e-05 1.730929e-03 280.70 -2.00 20.00 -2.00 345.21 0.00e+00 -3.685436e+07 9.325320e+03 1.334012e+06 2.008759e+05 3.963204e+06 262.12 -2.00 10.87 -2.00 352.33 0.00e+00 -6.393511e-02 1.288518e-04 3.973911e-03 1.027351e-03 4.436528e-02 224.46 -2.00 3.38 -2.00 330.46 0.00e+00 1.525162e-01 1.315670e-04 4.855099e-03 7.770773e-05 3.799738e-02 280.70 -2.00 20.00 -2.00 328.52 0.00e+00 1.795 0.000 319.50 362.20 4 2.3157e+00 3.1557e-04 3.3042e-02 2.3999e-03 1.3376e-01 -2.9919e-01 5.6924e-05 4.8419e-03 2.8069e-04 2.2576e-02 -2.6674e-01 7.9581e-05 9.3730e-03 3.7866e-04 3.4004e-02 -1.5126e-01 3.7387e-05 2.3584e-03 7.0328e-05 1.4516e-02 3.0559e-01 7.1907e-05 8.2671e-03 2.2856e-04 3.0587e-02 2.2945e-01 -1.5146e+00 2.6655e-04 2.2545e-02 6.6977e-04 1.0997e-01 -3.1920e-03 1.7261e-06 3.1853e-05 1.6495e-06 7.3182e-04 -3.0402e-02 0.0000e+00 3.1897e+01 7.6555e-03 2.7677e-01 8.5097e-03 3.1693e+00 12 10 8 10 0 0 99.98 16.07 0.39 -0.03040 -0.06980 1713 404 1 5 0 28.330 21.27 15.01 16.07 20.29 20.4 993.63 -3826 1502 5177 5389 2914 1074 219 939 -426 -1555 -3198 -3741 -4492 -4972 -4909 -3483 50 2672 2919 1163 820 1800 4023 4566 4690 3951 4617 5373 5339 3941 1931 475 660 1102 -310 -2349 -4192 -2439 166 1814 -298 -4447 -7783 -8769 -8257 -7872 -7145 -6583 -4755 -2682 -52 1341 1491 622 203 432 1584 1828 858 -864 -1920 -1026 678 2355 2534 1485 -711 -1560 -1259 545 1378 1069 143 374 1411 1414 262 -2062 -2652 -1143 1262 1512 1095 718 629 382 558 1799 4381 7777 9359 8519 6548 3853 914 314 1866 4472 4658 1381 -2916 -4606 -3724 -1243 1250 2859 3707 1814 -191 -1896 -1100 1123 2035 560 -1552 -2653 -2738 -2775 -3149 -2654 -1046 140 308 17 -863 -830 -238 439 -22 -819 -1989 -3666 -5911 -8163 -9727 -9282 -7299 -5784 -5630 -6255 -5866 -3806 -690 2416 4971 6344 6766 7198 8135 9285 9349 7412 3681 64 -1176 -1092 -1564 -3691 -4464 -3281 -1384 677 2545 4270 5205 4506 2658 1184 1377 2606 2979 1419 808 1560 3150 3379 2244 -78 -938 -197 1244 1305 -300 -1900 -1980 241 2801 3294 909 -2256 -3933 -4011 -4619 -6465 -7760 -6818 -3616 -1125 374 878 1546 3144 4465 4487 3511 1841 689 1058 2646 2743 830 -1626 -3513 -4243 -4558 -4393 -4456 -4099 -4978 -5884 -5655 -3607 -1191 266 611 449 733 1318 2472 2763 3152 2792 2660 2176 1781 590 398 897 1375 1435 1435 2420 2876 1767 227 64 791 1189 589 644 2106 4264 5039 3782 1946 686 -571 -1298 -4108 -8228 -10527 -8424 -3391 293 2368 4620 -2165 851 2952 3104 1708 642 134 581 -268 -998 -1941 -2317 -2841 -3199 -3204 -2302 33 1796 1983 805 580 1307 2994 3483 3651 2915 3445 4047 4050 3017 1493 371 520 874 -247 -1884 -3393 -1984 136 1487 -245 -3691 -6505 -7374 -6985 -6730 -6186 -5797 -4251 -2433 -47 1236 1383 580 190 404 1469 1682 784 -789 -1764 -948 630 2191 2361 1386 -668 -1472 -1191 514 1298 1007 135 355 1343 1351 251 -1972 -2532 -1087 1192 1428 1038 687 608 348 512 1652 4015 7561 9090 7800 6055 3594 855 290 1804 4235 4367 1303 -2803 -4491 -3417 -1207 1201 2736 3566 1665 -179 -1804 -1054 1075 1943 536 -1504 -2615 -2736 -2797 -3193 -2687 -1054 141 312 17 -901 -882 -256 474 -23 -879 -2122 -3902 -6291 -8704 -10387 -9895 -7758 -6160 -6031 -6783 -6058 -3952 -714 2485 5085 6488 6959 7457 8461 9670 9718 7680 3795 66 -1258 -1142 -1605 -3755 -4568 -3411 -1470 690 2635 4469 5478 4757 2802 1243 1437 2694 3065 1467 845 1654 3380 3667 2451 -86 -1025 -212 1325 1380 -318 -2040 -2155 265 3093 3645 1011 -2522 -4407 -4483 -5145 -7173 -8633 -7646 -4093 -1221 412 989 1774 3644 5185 5203 4055 2115 787 1201 2990 3111 954 -1901 -4164 -5048 -5382 -5105 -5107 -4670 -5709 -6861 -6384 -4143 -1383 310 717 531 871 1573 2952 3311 3787 3363 3216 2639 2157 713 478 1068 1621 1678 1672 2820 3360 2067 264 74 893 1309 634 683 2228 4533 5422 4135 2149 755 -619 -1376 -4261 -8421 -10708 -8603 -3503 309 2565 4903 SS 20240120T022533.8Z 8785.101086 257 1 7.86 2 55.96 167.51 100.91 55.04 0.00 1 0.00 1 7 257 3.712e-02 3.719e-02 4.913e-04 4.724e-04 5.606433e-05 1.645570e-07 8.428537e-07 3.824803e-07 1.285123e-05 224.46 -2.00 3.38 -2.00 340.02 0.00e+00 -2.167930e-02 5.070742e-05 9.548886e-04 1.496195e-05 4.033002e-03 280.70 -2.00 20.00 -2.00 337.58 0.00e+00 1.296083e-03 7.032269e-06 1.846931e-05 2.557599e-05 5.946454e-04 280.70 -2.00 20.00 -2.00 346.12 0.00e+00 -5.044703e-03 2.006215e-05 3.828505e-04 6.332336e-05 1.703453e-03 280.70 -2.00 20.00 -2.00 344.84 0.00e+00 -3.580648e+07 4.637160e+04 1.284669e+06 2.007765e+05 3.867195e+06 262.12 -2.00 10.87 -2.00 352.23 0.00e+00 -6.381631e-02 6.272234e-04 3.543738e-03 1.027195e-03 4.381102e-02 224.46 -2.00 3.38 -2.00 330.08 0.00e+00 1.393819e-01 6.181620e-04 4.821547e-03 7.923382e-05 3.747217e-02 280.70 -2.00 20.00 -2.00 328.07 0.00e+00 1.781 0.000 319.50 362.20 4 3.9540e+00 1.6033e-03 3.2365e-02 2.3881e-03 1.3292e-01 -2.5392e-01 2.6635e-04 4.5368e-03 2.8451e-04 2.0914e-02 -2.6963e-01 4.0421e-04 9.1008e-03 3.7374e-04 3.3631e-02 -1.5136e-01 1.8379e-04 2.3284e-03 6.7417e-05 1.4220e-02 3.0302e-01 3.6117e-04 8.0352e-03 2.2212e-04 2.9956e-02 4.5491e-02 -1.5460e+00 1.3652e-03 2.2724e-02 6.6559e-04 1.1078e-01 -3.2379e-03 8.7230e-06 2.9993e-05 1.6608e-06 7.2442e-04 -3.1524e-02 0.0000e+00 3.1065e+01 3.8630e-02 2.8589e-01 8.4710e-03 3.1495e+00 12 11 9 12 1 1 99.41 16.08 0.41 -0.03152 -0.07148 40 60 1 5 0 191.320 21.27 15.01 16.08 20.89 20.4 998.05 -3718 1669 4507 5449 2850 907 -466 640 -404 -1367 -3102 -3653 -4382 -4416 -4666 -3053 24 2906 3100 1202 929 1927 4081 4613 4780 3985 4222 5212 4959 3872 1664 456 404 902 -267 -2037 -4463 -2217 -119 1896 -276 -4576 -7913 -8847 -8026 -7861 -7014 -6212 -4580 -2511 -147 1337 1459 698 265 541 1601 2028 888 -935 -1843 -908 602 2197 2408 1577 -582 -1511 -1203 590 1268 863 189 323 1647 1404 -28 -1941 -2771 -1095 1286 1717 1056 896 846 679 711 1867 4378 7615 9101 8686 6550 3839 1076 474 1825 4274 4511 1168 -2706 -4434 -3513 -1222 1335 2563 3837 1814 -282 -1806 -1324 1014 2010 624 -1374 -2662 -2706 -2639 -3186 -2843 -1455 -120 -130 -576 -1249 -1135 -607 34 -240 -1120 -2302 -4167 -6194 -8318 -9849 -9317 -7216 -5922 -5534 -6090 -5836 -3780 -694 2144 4665 6057 6743 6890 7674 8866 8877 7028 3546 -194 -1414 -1372 -1759 -4051 -4629 -3342 -1346 684 2426 4013 5240 4524 2825 1175 1419 2418 2957 1297 903 1506 3163 3342 2072 -13 -804 -118 1202 1284 -302 -1898 -1930 79 2702 3033 1011 -2287 -4032 -4006 -4486 -6322 -7633 -6800 -3705 -1056 305 779 1638 3027 4342 4546 3523 2021 696 1032 2507 2726 790 -1632 -3592 -4385 -4703 -4412 -4481 -4274 -4991 -6010 -5656 -3695 -1256 228 651 415 683 1353 2751 2976 3395 2846 2728 2353 1722 577 303 909 1277 1574 1427 2402 2614 1707 84 85 875 1242 640 931 2138 4350 5109 3849 2186 813 -506 -1014 -3789 -7850 -10297 -8275 -3321 410 2412 4636 -2325 1045 2844 3466 1844 598 -313 437 -266 -915 -2120 -2548 -3121 -3196 -3431 -2273 17 2092 2257 891 704 1496 3244 3578 3781 3208 3441 4284 4107 3233 1405 389 333 746 -222 -1704 -3775 -1882 -101 1624 -238 -3972 -6919 -7781 -7091 -7017 -6330 -5692 -4076 -2266 -134 1225 1346 647 247 503 1479 1860 809 -852 -1688 -836 557 2038 2235 1465 -543 -1418 -1132 554 1187 808 177 305 1556 1332 -27 -1844 -2631 -1034 1208 1612 994 850 810 656 690 1814 4243 7332 8749 8387 6390 3780 1062 463 1751 4023 4201 1094 -2574 -4280 -3407 -1178 1272 2435 3654 1756 -278 -1812 -1284 1024 2024 604 -1344 -2648 -2728 -2683 -3260 -2907 -1483 -122 -133 -596 -1315 -1167 -631 36 -250 -1163 -2377 -4298 -6386 -8590 -10189 -9627 -7428 -6110 -5733 -6379 -6188 -4028 -738 2264 4897 6351 7097 7310 8177 9454 9454 7463 3746 -204 -1465 -1393 -1826 -4172 -4781 -3498 -1378 713 2568 4293 5627 4875 3041 1261 1513 2559 3111 1372 964 1630 3329 3555 2220 -14 -862 -126 1259 1388 -315 -2001 -2060 85 2925 3293 1102 -2507 -4436 -4400 -4911 -6897 -8347 -7494 -3965 -1145 336 874 1872 3372 4846 5063 3912 2233 766 1172 2831 3086 874 -1835 -4098 -5026 -5359 -4951 -4964 -4707 -5526 -6761 -6485 -4160 -1428 261 748 481 796 1581 3212 3487 3985 3240 3114 2693 1971 659 344 1057 1472 1797 1625 2734 2985 1949 96 96 966 1340 675 1001 2295 4683 5366 4104 2354 874 -538 -1055 -4004 -8196 -10694 -8622 -3369 423 2549 4870 SS 20240120T024208.2Z 8785.112595 269 1 48.68 2 55.36 172.16 98.15 57.56 0.00 1 0.00 1 7 257 3.683e-02 3.646e-02 5.987e-04 5.591e-04 5.563997e-05 1.943241e-07 8.541324e-07 3.824994e-07 1.273401e-05 224.46 -2.00 3.38 -2.00 340.52 0.00e+00 -2.298542e-02 6.018186e-05 9.909180e-04 1.535766e-05 3.989712e-03 280.70 -2.00 20.00 -2.00 338.17 0.00e+00 1.219006e-03 8.347050e-06 1.885549e-05 2.558384e-05 5.950257e-04 280.70 -2.00 20.00 -2.00 346.54 0.00e+00 -4.882392e-03 2.341696e-05 3.722990e-04 6.328457e-05 1.687659e-03 280.70 -2.00 20.00 -2.00 345.27 0.00e+00 -3.587703e+07 5.478641e+04 1.276890e+06 2.007741e+05 3.811657e+06 262.12 -2.00 10.87 -2.00 352.43 0.00e+00 -7.837505e-02 7.725963e-04 3.991239e-03 1.027634e-03 4.342652e-02 224.46 -2.00 3.38 -2.00 330.61 0.00e+00 1.397229e-01 7.914318e-04 5.274966e-03 8.405820e-05 3.721685e-02 280.70 -2.00 20.00 -2.00 328.74 0.00e+00 1.754 0.000 319.50 362.20 4 5.7142e+00 1.9197e-03 3.2457e-02 2.4057e-03 1.3393e-01 -2.3172e-01 3.0703e-04 4.3874e-03 2.8555e-04 1.9869e-02 -2.7953e-01 4.8251e-04 9.2309e-03 3.7786e-04 3.3599e-02 -1.5187e-01 2.2029e-04 2.3994e-03 6.7902e-05 1.4003e-02 3.0714e-01 4.2722e-04 8.0855e-03 2.2342e-04 2.9618e-02 8.4512e-03 -1.6105e+00 1.6611e-03 2.3434e-02 6.8749e-04 1.1257e-01 -3.3660e-03 1.0343e-05 3.0683e-05 1.6749e-06 7.1950e-04 -3.0160e-02 0.0000e+00 3.0564e+01 4.5899e-02 2.8766e-01 8.8037e-03 3.1408e+00 12 10 8 10 0 0 99.95 16.12 0.40 -0.03016 -0.07170 132 31 1 5 0 368.710 21.27 15.01 16.12 20.36 20.4 992.98 -3493 1063 5224 4138 2646 -553 -430 527 458 -1778 -3559 -3918 -4354 -4555 -4295 -2721 276 2837 3098 1321 806 2743 3689 5056 5047 4797 4455 5541 5342 3380 1741 667 418 1184 13 -2259 -4138 -2396 571 1592 8 -4626 -7558 -8824 -8550 -7926 -6893 -6414 -4640 -2619 -441 1465 1330 809 96 657 1533 1993 1128 -370 -1490 -605 782 2074 2669 1071 -709 -1898 -1446 209 1235 771 -52 64 1237 891 -239 -1992 -2988 -1126 953 1231 876 886 699 711 624 1989 4412 7418 9094 8187 6615 3727 1239 231 1794 4458 4362 1285 -2647 -4668 -3274 -1378 1317 2816 3514 1993 -123 -1692 -921 1517 1935 854 -1260 -2143 -2191 -2424 -3167 -2757 -970 -20 -12 -201 -1297 -1432 -497 -6 -546 -1474 -2477 -4230 -6150 -8529 -9957 -9473 -7627 -5807 -6070 -6410 -6168 -3731 -999 2229 4526 5911 6422 6774 7791 8906 9006 7074 3433 -125 -1106 -1201 -1406 -3735 -4285 -3318 -1374 331 2482 4281 5106 4540 2752 1366 1229 2790 3060 1510 844 1512 3044 3247 2161 89 -685 80 1204 1237 -150 -1730 -1820 119 2716 3115 747 -2228 -3787 -3844 -4554 -6244 -7456 -6497 -3458 -995 422 870 1497 2976 4319 4374 3376 1717 761 967 2530 2469 758 -1753 -3525 -4220 -4594 -4568 -4301 -4197 -4761 -5829 -5375 -3539 -1057 121 681 464 921 1499 2437 2825 2930 2646 2227 2015 1374 373 23 636 1181 1189 1118 2128 2657 1466 60 -121 761 1224 862 749 2270 4478 4880 3827 2009 747 -398 -792 -3781 -7589 -10009 -7844 -3359 478 2220 4429 -1919 585 2891 2317 1503 -321 -254 316 253 -1001 -2047 -2298 -2605 -2771 -2651 -1700 174 1806 1994 865 540 1877 2594 3631 3697 3570 3362 4213 4091 2615 1359 526 333 947 10 -1830 -3383 -1969 471 1319 7 -3881 -6377 -7495 -7305 -6829 -6000 -5673 -4164 -2383 -405 1352 1235 755 90 614 1426 1840 1033 -339 -1372 -560 728 1935 2487 1000 -665 -1791 -1366 197 1160 724 -49 61 1173 849 -228 -1896 -2845 -1067 898 1159 827 842 671 687 606 1932 4275 7144 8737 7911 6445 3667 1221 225 1719 4187 4058 1200 -2513 -4504 -3168 -1326 1253 2667 3343 1924 -121 -1692 -928 1523 1942 859 -1280 -2211 -2291 -2558 -3086 -2927 -1024 -21 -12 -197 -1298 -1458 -510 -6 -563 -1514 -2529 -4310 -6260 -8704 -10173 -9668 -7761 -5909 -6217 -6631 -6458 -3920 -1048 2320 4686 6113 6671 7088 8179 9357 9445 7399 3575 -130 -1128 -1200 -1379 -3636 -4182 -3285 -1385 340 2585 4499 5394 4809 2911 1440 1289 2898 3162 1567 885 1607 3271 3525 2360 98 -749 87 1286 1311 -159 -1858 -1980 131 2995 3444 829 -2486 -4239 -4294 -5076 -6933 -8294 -7278 -3905 -1138 491 1030 1666 3347 4864 4919 3784 1916 844 1068 2779 2721 846 -1988 -4052 -4872 -5273 -5171 -4799 -4659 -5308 -6605 -6203 -4153 -1252 145 815 559 1116 1823 2966 3446 3584 3244 2740 2484 1693 458 28 770 1415 1414 1325 2520 3150 1740 71 -141 873 1372 945 809 2446 4837 5331 4240 2249 834 -439 -855 -4010 -7945 -10423 -8188 -3540 475 2262 4637