File name: Pandora63s1_LaPorteTX_20220902_L2Fit_fsus1c2d20210924p1-8.txt File generation date: 20250514T181859.1Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Tom Hanisco Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 63 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora63_OF_v2d20210219.txt Instrument calibration file used: Pandora63s1_CF_v2d20210924.txt Level 1 file used: Pandora63s1_LaPorteTX_20220902_L1_smca1c2d20210924p1-8.txt Full location name: University Of Houston Trailer Short location name: LaPorteTX Country of location: United States Location latitude [deg]: 29.6721 Location longitude [deg]: -95.0647 Location altitude [m]: 22 Local noon date: 20220902 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 148 293 Nominal wavelengths inside fitting window [nm]: 306.0240 306.1653 306.3066 306.4478 306.5891 306.7303 306.8715 307.0127 307.1539 307.2951 307.4362 307.5774 307.7185 307.8597 308.0008 308.1419 308.2830 308.4241 308.5652 308.7063 308.8473 308.9884 309.1294 309.2704 309.4114 309.5524 309.6934 309.8344 309.9753 310.1163 310.2572 310.3982 310.5391 310.6800 310.8209 310.9618 311.1027 311.2435 311.3844 311.5252 311.6661 311.8069 311.9477 312.0885 312.2293 312.3700 312.5108 312.6515 312.7923 312.9330 313.0737 313.2144 313.3551 313.4958 313.6365 313.7771 313.9178 314.0584 314.1991 314.3397 314.4803 314.6209 314.7615 314.9020 315.0426 315.1831 315.3237 315.4642 315.6047 315.7452 315.8857 316.0262 316.1667 316.3071 316.4476 316.5880 316.7284 316.8688 317.0092 317.1496 317.2900 317.4304 317.5707 317.7111 317.8514 317.9917 318.1321 318.2724 318.4126 318.5529 318.6932 318.8334 318.9737 319.1139 319.2541 319.3944 319.5346 319.6747 319.8149 319.9551 320.0952 320.2354 320.3755 320.5156 320.6557 320.7958 320.9359 321.0760 321.2161 321.3561 321.4962 321.6362 321.7762 321.9162 322.0562 322.1962 322.3362 322.4761 322.6161 322.7560 322.8959 323.0359 323.1758 323.3157 323.4555 323.5954 323.7353 323.8751 324.0150 324.1548 324.2946 324.4344 324.5742 324.7140 324.8538 324.9935 325.1333 325.2730 325.4127 325.5524 325.6921 325.8318 325.9715 326.1112 326.2508 326.3905 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SU 20220902T190633.2Z 8280.796218 1755 1 50.07 2 24.55 208.84 79.08 122.52 0.00 1 0.00 1 0 49 4.528e-03 2.544e-03 3.508e-03 2.056e-03 -2.336061e-06 7.755802e-07 3.278918e-08 4.739828e-07 2.090567e-06 228.90 -2.00 3.24 -2.00 321.25 0.00e+00 1.191753e-03 2.693824e-04 3.761002e-06 4.307129e-05 5.634819e-04 294.00 -2.00 20.00 -2.00 321.09 0.00e+00 6.550431e-04 3.849687e-04 7.588409e-06 3.290256e-05 9.519793e-04 294.00 -2.00 20.00 -2.00 321.27 0.00e+00 5.160781e-04 5.138469e-04 6.089903e-05 4.345145e-05 1.025161e-03 294.00 -2.00 20.00 -2.00 321.17 0.00e+00 1.361320e-01 2.740712e-03 1.428437e-04 3.609278e-03 5.512502e-03 233.08 5.06 0.00 4.24 9.60 316.86 0.00e+00 4.446528e-05 1.336530e-04 1.493191e-05 5.926088e-05 1.492662e-04 294.00 -2.00 20.00 -2.00 315.54 0.00e+00 1.099 0.000 303.00 329.40 4 5.6372e+00 8.1869e-03 1.0673e-02 3.5593e-03 1.7948e-02 -3.7385e-02 1.0391e-02 1.3197e-03 1.6321e-03 1.8810e-02 1.4698e-02 5.5576e-03 2.9220e-04 5.9817e-04 1.0647e-02 -6.1964e-03 1.9326e-03 8.6985e-05 8.6717e-05 3.8047e-03 1.6201e-03 1.4496e-03 2.2100e-05 7.4290e-05 2.5597e-03 6.7595e-04 -3.1152e-03 2.0981e-03 1.4821e-04 1.5254e-04 2.8933e-03 3.9315e-04 6.5804e-05 3.0249e-06 1.8800e-06 1.4693e-04 -4.9594e-03 7.4735e-05 -2.5971e-01 2.5026e-01 3.2777e-03 1.8742e-03 4.7463e-01 12 9 8 11 8 0 98.75 17.54 0.24 -0.00496 -0.00196 13 3 1 5 0 3851.050 20.67 15.01 17.54 40.82 13.1 1044.88 1081 -613 815 -312 -479 1469 -1468 368 -895 660 -825 1040 -55 762 -174 -1546 85 -1537 422 -420 1051 -467 347 795 646 -409 205 495 352 64 -1008 193 -258 547 -405 435 -50 -56 574 -239 230 -192 -82 -397 240 -300 807 -140 438 -145 -51 416 -314 244 -426 115 -457 56 -181 178 -37 115 -79 -251 -342 -126 128 -193 291 -271 370 403 490 -317 46 -62 32 198 54 -75 -92 473 -48 -294 -113 -291 55 -562 -152 -169 86 -294 -5 33 537 -268 155 168 -72 106 -79 376 -215 320 -4 183 140 63 5 -123 -104 132 16 -95 -135 179 158 -262 -208 30 164 190 -319 -23 -341 -58 -221 271 -230 155 134 189 34 -157 -189 -295 217 16 67 53 -4 4 173 -102 -33 0 232 -147 202 -78 -118 373 -421 114 -297 223 -284 362 -20 278 -64 -571 32 -620 172 -174 411 -173 122 280 239 -160 83 194 132 25 -456 100 -150 340 -262 286 -33 -37 378 -155 145 -119 -50 -246 155 -202 553 -99 311 -106 -38 298 -227 180 -330 94 -390 48 -145 131 -26 85 -65 -220 -309 -114 114 -165 231 -198 256 285 380 -269 41 -59 31 201 59 -84 -105 541 -54 -314 -112 -267 50 -526 -151 -179 96 -347 -6 36 559 -276 165 191 -86 129 -99 484 -286 436 -6 240 174 74 6 -139 -122 163 20 -127 -177 231 198 -318 -245 34 186 227 -398 -30 -440 -75 -294 375 -328 225 199 280 50 -228 -270 -420 316 24 107 89 -6 6 309 -184 -59 0 SU 20220902T190924.7Z 8280.798203 1758 1 48.87 2 24.86 210.37 78.58 122.93 0.00 1 0.00 1 0 49 3.837e-03 2.334e-03 3.570e-03 2.064e-03 4.023162e-08 7.757765e-07 4.233280e-08 4.739871e-07 1.769159e-06 228.90 -2.00 3.24 -2.00 321.29 0.00e+00 7.619855e-04 2.683710e-04 2.580153e-05 4.303265e-05 4.769959e-04 294.00 -2.00 20.00 -2.00 321.14 0.00e+00 6.317830e-04 3.869617e-04 9.103083e-06 3.284470e-05 8.064859e-04 294.00 -2.00 20.00 -2.00 321.30 0.00e+00 1.146687e-04 5.004032e-04 5.048582e-05 4.352295e-05 8.685731e-04 294.00 -2.00 20.00 -2.00 321.21 0.00e+00 1.405375e-01 2.795470e-03 1.439802e-04 3.609350e-03 4.670161e-03 246.34 5.17 0.00 4.13 8.13 316.95 0.00e+00 3.068723e-04 1.357299e-04 2.884572e-05 5.926169e-05 1.264113e-04 294.00 -2.00 20.00 -2.00 315.60 0.00e+00 1.102 0.000 303.00 329.40 4 5.5681e+00 9.4663e-03 1.0688e-02 3.5620e-03 1.5212e-02 -1.9229e-02 1.1372e-02 1.5022e-03 1.6351e-03 1.5929e-02 4.5458e-03 5.8607e-03 2.3417e-04 6.0232e-04 9.0142e-03 -3.3381e-03 1.9643e-03 2.2863e-04 8.7693e-05 3.2268e-03 2.3569e-03 1.4600e-03 9.0446e-05 7.3931e-05 2.1675e-03 7.1209e-04 -4.6498e-03 2.0979e-03 1.4210e-04 1.5335e-04 2.4718e-03 3.6405e-04 6.6018e-05 2.7222e-06 1.8785e-06 1.2455e-04 -4.0688e-03 1.0662e-04 -4.5805e-01 2.5159e-01 3.6520e-03 2.0007e-03 4.0488e-01 12 8 8 10 0 0 99.16 17.54 0.20 -0.00407 -0.00129 14 3 1 5 0 3489.760 20.67 15.01 17.54 40.73 13.1 1044.47 1052 -1242 1019 206 1221 -125 651 -1588 555 53 -479 -46 160 -656 -3 197 -148 -166 -800 310 283 -27 200 -616 541 -231 534 -412 585 -301 305 27 348 -337 -142 -200 -304 176 154 756 -463 490 -666 398 -176 -36 -150 527 3 -121 694 -269 146 -454 194 57 418 -378 17 41 -390 595 -254 43 -314 155 46 -274 -126 -546 15 -40 234 -257 206 -385 197 -128 197 -111 52 -10 182 -189 -176 431 -171 234 -407 -10 -149 214 -46 252 412 -67 13 -74 182 -199 315 -100 90 15 -65 -188 125 191 -187 140 -332 102 -32 -6 -290 314 -70 80 41 -353 115 38 -20 -372 468 -429 -60 193 11 77 85 72 -82 -109 -35 152 -97 3 -39 -64 105 36 205 -36 -20 -149 221 -293 248 51 289 -32 179 -488 179 18 -162 -16 57 -239 -1 70 -55 -65 -324 125 109 -10 69 -215 198 -90 213 -161 215 -117 134 14 199 -208 -91 -130 -201 115 101 485 -291 297 -401 241 -112 -24 -103 369 2 -88 498 -193 104 -331 149 46 353 -322 13 30 -276 434 -205 38 -283 140 41 -233 -100 -396 11 -28 180 -216 184 -364 191 -130 212 -124 60 -12 203 -200 -174 393 -153 216 -404 -10 -169 251 -54 279 429 -69 14 -84 216 -243 395 -129 119 20 -89 -247 155 222 -210 158 -391 126 -42 -8 -383 402 -88 98 48 -403 131 45 -25 -477 600 -561 -80 268 16 112 126 108 -122 -159 -50 217 -143 5 -63 -107 182 65 371 -64 -36 -263 SU 20220902T191352.5Z 8280.801302 1764 1 50.59 2 25.37 212.68 77.81 123.59 0.00 1 0.00 1 0 49 3.806e-03 2.044e-03 3.524e-03 2.062e-03 -5.591684e-08 7.735685e-07 4.716122e-09 4.739849e-07 1.754008e-06 228.90 -2.00 3.24 -2.00 321.26 0.00e+00 5.911650e-04 2.666739e-04 7.276579e-06 4.308422e-05 4.730116e-04 294.00 -2.00 20.00 -2.00 321.10 0.00e+00 9.875520e-04 3.867533e-04 3.259545e-06 3.289951e-05 8.005196e-04 294.00 -2.00 20.00 -2.00 321.27 0.00e+00 3.541304e-04 4.917220e-04 3.982081e-05 4.358649e-05 8.617159e-04 294.00 -2.00 20.00 -2.00 321.18 0.00e+00 1.430560e-01 2.779575e-03 1.058741e-04 3.609400e-03 4.631760e-03 250.07 5.10 0.00 4.03 8.07 316.91 0.00e+00 1.019401e-04 1.340936e-04 1.542601e-05 5.926150e-05 1.254701e-04 294.00 -2.00 20.00 -2.00 315.55 0.00e+00 1.106 0.000 303.00 329.40 4 5.6141e+00 9.8386e-03 1.0735e-02 3.5588e-03 1.5081e-02 -7.4801e-03 1.1526e-02 1.2174e-03 1.6291e-03 1.5796e-02 6.6582e-04 5.8860e-03 2.5979e-04 5.9774e-04 8.9383e-03 -2.5689e-03 1.9512e-03 1.1412e-04 8.6526e-05 3.1984e-03 2.6022e-03 1.4541e-03 2.0039e-05 7.3901e-05 2.1512e-03 6.6722e-04 -3.5431e-03 2.0864e-03 8.2712e-05 1.5413e-04 2.4647e-03 6.9983e-05 6.6215e-05 1.6380e-06 1.8431e-06 1.2293e-04 -2.5707e-03 6.9304e-05 9.1638e-02 2.5025e-01 1.7737e-03 1.9032e-03 4.0103e-01 12 8 8 10 0 0 29.35 17.55 0.11 -0.00257 -0.00204 13 3 1 5 0 3890.820 20.67 14.98 17.55 40.59 13.1 1043.48 -1597 822 783 1244 1404 -52 208 -439 -866 -1028 188 119 -849 361 489 -626 359 -702 -53 495 -346 -394 573 503 -417 -50 178 343 -341 1242 85 10 174 -581 76 -304 -129 136 -114 338 577 234 119 -254 -230 -255 1 171 328 -129 281 -110 123 6 85 -26 99 -161 -113 40 251 29 2 89 -168 26 -221 -160 -318 -143 53 289 -315 -172 37 -155 -40 85 265 -85 -43 268 -74 -308 -257 -107 362 -539 63 -30 126 16 -95 521 389 -147 -119 44 -189 125 7 -143 171 205 114 107 20 -152 -226 -25 -121 112 273 -68 -306 169 -55 178 80 195 -251 -72 -126 -241 86 -206 -127 79 -82 29 270 -155 -58 161 -31 -147 -142 97 185 88 -62 15 68 -27 -94 27 -349 194 194 307 337 -13 59 -137 -287 -353 64 41 -305 132 178 -230 135 -279 -22 202 -137 -146 200 178 -156 -19 72 135 -129 487 38 5 100 -363 49 -200 -85 90 -75 220 362 144 72 -157 -149 -173 1 120 233 -93 205 -79 88 5 66 -21 84 -138 -91 29 179 21 2 78 -151 24 -196 -137 -253 -105 37 205 -246 -145 33 -147 -39 86 285 -96 -49 306 -84 -329 -253 -99 323 -503 62 -32 142 19 -111 575 408 -151 -127 50 -227 152 8 -185 228 278 154 140 25 -178 -255 -28 -141 138 352 -91 -403 216 -69 216 94 220 -286 -86 -157 -307 110 -267 -169 110 -118 42 398 -230 -85 233 -44 -209 -207 147 293 147 -108 26 122 -48 -167 47 SU 20220902T191644.3Z 8280.803290 1767 1 48.91 2 25.71 214.12 77.31 124.02 0.00 1 0.00 1 0 49 4.312e-03 2.238e-03 3.507e-03 2.047e-03 -1.702133e-06 7.713949e-07 4.852273e-08 4.739889e-07 1.990352e-06 228.90 -2.00 3.24 -2.00 321.25 0.00e+00 8.974278e-04 2.681450e-04 2.555334e-05 4.307792e-05 5.346041e-04 294.00 -2.00 20.00 -2.00 321.09 0.00e+00 7.391622e-04 3.826577e-04 1.848069e-05 3.301399e-05 9.046494e-04 294.00 -2.00 20.00 -2.00 321.27 0.00e+00 1.170400e-03 5.120994e-04 8.751854e-05 4.326837e-05 9.764057e-04 294.00 -2.00 20.00 -2.00 321.17 0.00e+00 1.358482e-01 2.722664e-03 1.518741e-04 3.609372e-03 5.254606e-03 232.38 5.03 0.00 4.22 9.16 316.87 0.00e+00 3.089358e-04 1.332692e-04 5.860723e-06 5.926181e-05 1.421634e-04 294.00 -2.00 20.00 -2.00 315.56 0.00e+00 1.110 0.000 303.00 329.40 4 5.5895e+00 8.0671e-03 1.0802e-02 3.5533e-03 1.7093e-02 -3.8568e-02 1.0283e-02 1.4867e-03 1.6309e-03 1.7931e-02 1.4732e-02 5.5068e-03 3.3445e-04 5.9601e-04 1.0117e-02 -7.9729e-03 1.9229e-03 2.5993e-04 8.5780e-05 3.6315e-03 3.4040e-03 1.4442e-03 7.3609e-05 7.4443e-05 2.4307e-03 6.9484e-04 -2.7341e-03 2.0756e-03 1.6766e-04 1.4868e-04 2.7057e-03 1.2670e-04 6.5319e-05 2.8513e-06 1.8438e-06 1.3923e-04 -5.4550e-03 -1.2876e-05 -9.0661e-02 2.4732e-01 4.3790e-03 1.5849e-03 4.5114e-01 12 9 8 11 8 0 -19.13 17.55 0.18 -0.00546 -0.00449 13 3 1 5 0 3761.770 20.67 15.02 17.55 40.51 13.2 1043.28 1982 70 961 299 1568 1920 -286 -494 395 -1097 -883 -456 194 -228 -1197 172 -109 -884 -526 99 -81 -547 259 -396 -263 24 278 626 -649 977 -162 -225 62 -464 -268 321 169 207 553 156 466 172 161 19 250 128 55 163 -194 362 -246 132 68 -156 -222 297 -191 -524 305 -17 241 330 -426 -114 -331 -125 -27 34 -227 -485 400 -264 -197 -156 153 -156 241 480 183 272 -569 398 -239 -9 -170 188 -263 36 -63 -328 84 17 183 417 -76 4 -39 127 -250 -42 79 211 -141 179 27 -6 -100 201 -287 -36 -270 178 54 112 -336 60 241 65 -5 -26 -146 -160 -284 -50 57 -102 -11 79 202 50 29 -2 -50 -124 121 -172 1 73 93 131 20 50 26 -4 -118 -73 415 16 236 73 376 482 -81 -152 129 -374 -306 -161 70 -84 -442 63 -41 -350 -214 40 -32 -202 91 -141 -99 9 113 244 -247 386 -73 -116 36 -289 -173 210 111 138 365 101 294 105 97 12 160 86 38 115 -139 262 -179 96 49 -115 -171 243 -162 -446 245 -12 173 242 -347 -99 -300 -113 -24 30 -181 -356 279 -190 -154 -133 138 -147 233 491 198 304 -658 453 -270 -9 -167 173 -234 33 -63 -349 94 20 214 460 -80 4 -41 145 -297 -51 100 270 -187 244 37 -8 -125 234 -324 -41 -315 221 71 147 -446 77 302 79 -6 -30 -166 -193 -357 -63 73 -132 -15 109 287 73 43 -3 -74 -178 173 -245 2 112 148 217 34 89 47 -7 -208 -127 SU 20220902T191934.1Z 8280.805255 1770 1 50.32 2 26.06 215.51 76.82 124.45 0.00 1 0.00 1 0 49 3.040e-03 1.937e-03 3.476e-03 2.005e-03 -2.259249e-07 7.540518e-07 2.622513e-08 4.739949e-07 1.399234e-06 228.90 -2.00 3.24 -2.00 321.29 0.00e+00 5.978079e-04 2.616587e-04 9.227554e-06 4.302274e-05 3.774207e-04 294.00 -2.00 20.00 -2.00 321.14 0.00e+00 6.167733e-04 3.758474e-04 9.348934e-06 3.282525e-05 6.382240e-04 294.00 -2.00 20.00 -2.00 321.30 0.00e+00 5.223065e-04 4.934934e-04 3.734026e-05 4.341852e-05 6.882737e-04 294.00 -2.00 20.00 -2.00 321.21 0.00e+00 1.421909e-01 2.707578e-03 1.026289e-04 3.609397e-03 3.699119e-03 240.73 4.88 0.00 3.99 6.45 316.96 0.00e+00 -3.772731e-05 1.319244e-04 3.985040e-05 5.926195e-05 1.002709e-04 294.00 -2.00 20.00 -2.00 315.61 0.00e+00 1.113 0.000 303.00 329.40 4 5.5377e+00 8.6508e-03 1.0804e-02 3.5610e-03 1.2020e-02 -2.0534e-02 1.0692e-02 1.4115e-03 1.6361e-03 1.2624e-02 2.6800e-03 5.5908e-03 2.9913e-04 6.0328e-04 7.1291e-03 -3.6222e-03 1.9055e-03 3.9629e-05 8.8383e-05 2.5555e-03 4.3709e-03 1.4193e-03 4.3406e-05 7.3735e-05 1.7152e-03 7.2092e-04 8.1707e-05 2.0532e-03 7.4549e-05 1.5304e-04 1.9162e-03 -1.9505e-04 6.4391e-05 1.6119e-06 1.8281e-06 9.7636e-05 -2.8673e-03 -4.0886e-06 1.4037e-01 2.4351e-01 2.7293e-03 1.9843e-03 3.1900e-01 12 8 8 10 0 0 26.01 17.55 0.10 -0.00287 -0.00436 14 3 1 5 0 3593.250 20.67 15.00 17.55 40.45 13.2 1043.04 435 291 -104 -708 1099 688 641 -512 176 -232 413 -321 -450 -783 -1027 -27 18 -379 -552 72 136 205 394 462 -5 -189 72 193 6 1204 568 -308 253 190 -512 83 -167 390 413 22 81 332 91 -259 -126 140 -177 -251 -104 -85 107 83 -38 229 146 -231 219 -296 -82 275 9 26 -107 -311 -106 182 291 -285 100 -80 -295 -76 -232 55 112 -161 182 150 -19 -104 -4 98 -97 -407 -143 70 -67 90 -177 -89 -128 3 103 364 334 -238 -99 19 -235 219 25 184 141 173 -91 109 100 -3 -225 84 -252 93 405 39 -260 148 103 -207 164 -133 148 -307 -48 -353 65 -46 -80 254 -95 -182 39 139 55 -169 -85 -214 263 144 -83 -5 -13 19 4 89 -110 69 91 67 -25 -173 260 171 176 -156 57 -77 138 -111 -159 -285 -373 -10 7 -149 -224 29 53 74 136 160 -2 -73 29 75 2 466 249 -158 145 118 -328 54 -110 255 269 14 50 201 54 -158 -81 94 -122 -176 -74 -62 78 60 -28 167 111 -188 184 -252 -65 200 7 19 -88 -271 -95 164 256 -243 78 -58 -205 -54 -180 46 101 -152 177 152 -21 -117 -4 113 -108 -434 -142 65 -60 83 -175 -94 -144 3 120 403 348 -244 -105 21 -280 267 31 236 188 236 -123 143 124 -4 -253 96 -297 115 525 52 -344 190 129 -252 193 -152 169 -368 -60 -452 84 -60 -107 353 -137 -265 59 207 82 -245 -121 -305 384 219 -132 -9 -22 33 8 161 -198 121 SU 20220902T192221.1Z 8280.807189 1773 1 48.05 2 26.42 216.85 76.35 124.87 0.00 1 0.00 1 0 49 4.382e-03 2.292e-03 3.471e-03 2.002e-03 -1.150660e-06 7.521191e-07 4.697233e-08 4.739946e-07 2.024143e-06 228.90 -2.00 3.24 -2.00 321.29 0.00e+00 1.316438e-04 2.604766e-04 2.893314e-05 4.304386e-05 5.444933e-04 294.00 -2.00 20.00 -2.00 321.14 0.00e+00 2.944065e-04 3.752548e-04 2.130515e-05 3.282685e-05 9.196924e-04 294.00 -2.00 20.00 -2.00 321.29 0.00e+00 1.456239e-03 4.864631e-04 7.729751e-05 4.336639e-05 9.920546e-04 294.00 -2.00 20.00 -2.00 321.21 0.00e+00 1.404769e-01 2.709393e-03 1.239662e-04 3.609352e-03 5.339103e-03 244.89 4.99 0.00 4.08 9.30 316.97 0.00e+00 2.195260e-04 1.317955e-04 2.073247e-05 5.926193e-05 1.444827e-04 294.00 -2.00 20.00 -2.00 315.61 0.00e+00 1.116 0.000 303.00 329.40 4 5.4857e+00 9.0354e-03 1.0874e-02 3.5609e-03 1.7378e-02 -2.8478e-02 1.0939e-02 1.3664e-03 1.6369e-03 1.8224e-02 5.3332e-03 5.6600e-03 4.2897e-04 6.0389e-04 1.0304e-02 -4.6171e-03 1.9117e-03 2.2450e-04 8.8843e-05 3.6935e-03 4.9783e-03 1.4167e-03 9.7750e-05 7.4013e-05 2.4721e-03 7.5209e-04 -5.1003e-03 2.0208e-03 1.1274e-04 1.5384e-04 2.7652e-03 5.5472e-05 6.4100e-05 1.6584e-06 1.8486e-06 1.4143e-04 -3.3917e-03 3.9531e-05 -2.1260e-01 2.4247e-01 4.9347e-03 1.9788e-03 4.5770e-01 12 8 8 10 0 0 74.74 17.55 0.20 -0.00339 -0.00297 14 3 1 5 0 3431.420 20.67 15.02 17.55 40.43 13.2 1042.91 2669 -1230 939 -1027 807 375 -1019 -425 -671 -130 -321 -70 -298 -400 -360 399 493 320 293 -678 517 33 1324 -936 239 -381 535 389 269 -148 -741 886 -163 138 -796 253 -174 -72 165 379 142 45 200 -70 52 -226 360 -13 180 -153 325 -93 -239 537 66 -202 -331 314 -447 -23 12 347 -324 152 76 112 -202 -697 12 60 479 -363 225 -320 -163 155 173 215 20 -9 -386 139 -52 -139 -302 -106 136 -255 21 -247 102 -9 -144 364 371 -84 -148 125 13 86 28 44 161 301 43 28 -10 236 -87 40 -71 -219 203 135 0 -146 207 -209 -8 -295 59 42 -187 -41 40 -249 -437 152 -51 112 -147 371 -269 -28 73 -62 112 -34 169 -135 67 -25 203 -90 51 -94 548 -289 228 -251 192 94 -284 -129 -218 -43 -108 -24 -105 -145 -131 142 182 125 118 -275 200 12 454 -328 88 -148 214 151 100 -58 -328 446 -94 85 -512 164 -114 -47 108 243 88 27 120 -43 33 -151 246 -9 128 -111 235 -67 -172 390 51 -165 -281 267 -357 -17 9 255 -264 132 69 101 -180 -595 9 44 332 -259 173 -270 -147 147 168 218 22 -10 -443 158 -58 -148 -299 -97 121 -237 21 -262 115 -11 -168 401 388 -87 -158 142 15 104 35 57 214 410 58 37 -13 276 -98 45 -83 -271 264 179 0 -189 260 -254 -10 -336 68 50 -234 -52 51 -323 -586 210 -74 163 -218 553 -398 -40 105 -88 164 -52 270 -226 117 -44 366 -163 91 -165