File name: Pandora130s1_Lindenberg_20221226_L2Fit_fnvs5c6d20220715p1-8.txt File generation date: 20250813T123419.5Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c6p1-8 Local principal investigator: Lionel Doppler Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 130 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora130_OF_v3d20201102.txt Instrument calibration file used: Pandora130s1_CF_v6d20220715.txt Level 1 file used: Pandora130s1_Lindenberg_20221226_L1_smca1c6d20220715p1-8.txt Full location name: DWD Observatory Lindenberg Short location name: Lindenberg Country of location: Germany Location latitude [deg]: 52.2900 Location longitude [deg]: 14.1200 Location altitude [m]: 127 Local noon date: 20221226 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: "AnaLab+fld for 20220715 VP" session 5 from check dispersion First and last pixel inside fitting window: 931 1477 Nominal wavelengths inside fitting window [nm]: 400.0402 400.1723 400.3045 400.4366 400.5688 400.7009 400.8330 400.9651 401.0971 401.2292 401.3612 401.4933 401.6253 401.7573 401.8893 402.0212 402.1532 402.2851 402.4171 402.5490 402.6809 402.8128 402.9446 403.0765 403.2083 403.3402 403.4720 403.6038 403.7356 403.8673 403.9991 404.1308 404.2625 404.3943 404.5260 404.6576 404.7893 404.9210 405.0526 405.1842 405.3158 405.4474 405.5790 405.7106 405.8421 405.9737 406.1052 406.2367 406.3682 406.4997 406.6311 406.7626 406.8940 407.0254 407.1569 407.2882 407.4196 407.5510 407.6823 407.8137 407.9450 408.0763 408.2076 408.3389 408.4701 408.6014 408.7326 408.8638 408.9950 409.1262 409.2574 409.3886 409.5197 409.6508 409.7819 409.9130 410.0441 410.1752 410.3063 410.4373 410.5683 410.6993 410.8303 410.9613 411.0923 411.2233 411.3542 411.4851 411.6160 411.7469 411.8778 412.0087 412.1395 412.2704 412.4012 412.5320 412.6628 412.7936 412.9243 413.0551 413.1858 413.3165 413.4472 413.5779 413.7086 413.8393 413.9699 414.1006 414.2312 414.3618 414.4924 414.6229 414.7535 414.8840 415.0146 415.1451 415.2756 415.4061 415.5365 415.6670 415.7974 415.9279 416.0583 416.1887 416.3190 416.4494 416.5798 416.7101 416.8404 416.9707 417.1010 417.2313 417.3616 417.4918 417.6221 417.7523 417.8825 418.0127 418.1428 418.2730 418.4031 418.5333 418.6634 418.7935 418.9236 419.0536 419.1837 419.3137 419.4438 419.5738 419.7038 419.8338 419.9637 420.0937 420.2236 420.3535 420.4834 420.6133 420.7432 420.8731 421.0029 421.1328 421.2626 421.3924 421.5222 421.6519 421.7817 421.9115 422.0412 422.1709 422.3006 422.4303 422.5599 422.6896 422.8192 422.9489 423.0785 423.2081 423.3377 423.4672 423.5968 423.7263 423.8558 423.9853 424.1148 424.2443 424.3738 424.5032 424.6326 424.7621 424.8915 425.0208 425.1502 425.2796 425.4089 425.5382 425.6675 425.7968 425.9261 426.0554 426.1846 426.3139 426.4431 426.5723 426.7015 426.8307 426.9598 427.0890 427.2181 427.3472 427.4763 427.6054 427.7345 427.8636 427.9926 428.1216 428.2506 428.3796 428.5086 428.6376 428.7665 428.8955 429.0244 429.1533 429.2822 429.4111 429.5399 429.6688 429.7976 429.9264 430.0552 430.1840 430.3128 430.4415 430.5703 430.6990 430.8277 430.9564 431.0851 431.2138 431.3424 431.4710 431.5997 431.7283 431.8569 431.9854 432.1140 432.2425 432.3711 432.4996 432.6281 432.7566 432.8850 433.0135 433.1419 433.2704 433.3988 433.5272 433.6556 433.7839 433.9123 434.0406 434.1689 434.2972 434.4255 434.5538 434.6820 434.8103 434.9385 435.0667 435.1949 435.3231 435.4513 435.5794 435.7076 435.8357 435.9638 436.0919 436.2200 436.3480 436.4761 436.6041 436.7321 436.8601 436.9881 437.1161 437.2440 437.3720 437.4999 437.6278 437.7557 437.8836 438.0115 438.1393 438.2671 438.3950 438.5228 438.6506 438.7783 438.9061 439.0338 439.1616 439.2893 439.4170 439.5447 439.6723 439.8000 439.9276 440.0552 440.1828 440.3104 440.4380 440.5656 440.6931 440.8207 440.9482 441.0757 441.2032 441.3306 441.4581 441.5855 441.7129 441.8404 441.9677 442.0951 442.2225 442.3498 442.4772 442.6045 442.7318 442.8591 442.9863 443.1136 443.2408 443.3681 443.4953 443.6225 443.7497 443.8768 444.0040 444.1311 444.2582 444.3853 444.5124 444.6395 444.7665 444.8936 445.0206 445.1476 445.2746 445.4016 445.5286 445.6555 445.7825 445.9094 446.0363 446.1632 446.2900 446.4169 446.5437 446.6706 446.7974 446.9242 447.0510 447.1777 447.3045 447.4312 447.5579 447.6846 447.8113 447.9380 448.0647 448.1913 448.3179 448.4446 448.5712 448.6977 448.8243 448.9509 449.0774 449.2039 449.3304 449.4569 449.5834 449.7098 449.8363 449.9627 450.0891 450.2155 450.3419 450.4683 450.5946 450.7210 450.8473 450.9736 451.0999 451.2262 451.3524 451.4787 451.6049 451.7311 451.8573 451.9835 452.1097 452.2358 452.3619 452.4881 452.6142 452.7403 452.8663 452.9924 453.1184 453.2445 453.3705 453.4965 453.6225 453.7484 453.8744 454.0003 454.1262 454.2521 454.3780 454.5039 454.6298 454.7556 454.8814 455.0072 455.1330 455.2588 455.3846 455.5103 455.6361 455.7618 455.8875 456.0132 456.1388 456.2645 456.3901 456.5158 456.6414 456.7670 456.8925 457.0181 457.1437 457.2692 457.3947 457.5202 457.6457 457.7712 457.8966 458.0221 458.1475 458.2729 458.3983 458.5237 458.6490 458.7744 458.8997 459.0250 459.1503 459.2756 459.4009 459.5261 459.6513 459.7766 459.9018 460.0270 460.1521 460.2773 460.4024 460.5276 460.6527 460.7778 460.9029 461.0279 461.1530 461.2780 461.4030 461.5280 461.6530 461.7780 461.9029 462.0279 462.1528 462.2777 462.4026 462.5275 462.6523 462.7772 462.9020 463.0268 463.1516 463.2764 463.4012 463.5259 463.6507 463.7754 463.9001 464.0248 464.1495 464.2741 464.3988 464.5234 464.6480 464.7726 464.8972 465.0217 465.1463 465.2708 465.3953 465.5198 465.6443 465.7688 465.8932 466.0177 466.1421 466.2665 466.3909 466.5153 466.6396 466.7640 466.8883 467.0126 467.1369 467.2612 467.3854 467.5097 467.6339 467.7581 467.8823 468.0065 468.1307 468.2548 468.3790 468.5031 468.6272 468.7513 468.8754 468.9994 469.1235 469.2475 469.3715 469.4955 469.6195 469.7434 469.8674 469.9913 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Spectrometer control temperature [°C], 999=no temperature signal Column 159: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 160: Temperature in head sensor [°C], 999=no temperature signal Column 161: Temperature at electronics board 1 [°C], 999=no temperature signal Column 162: Temperature at electronics board 2 [°C], 999=no temperature signal Column 163: Humidity in head sensor [%], -9=no humidity signal Column 164: Pressure in head sensor [hPa], -9=no pressure signal Columns 165-711: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 712-1258: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20221226T074537.9Z 8395.323355 81 1 7.92 2 87.12 135.58 109.94 100.19 0.00 1 0.00 1 0 49 7.138e-03 4.935e-03 3.322e-03 2.575e-03 1.076025e+04 4.916251e+02 9.516312e+02 5.375999e+02 1.380265e+03 267.06 -2.00 20.00 -2.00 450.16 0.00e+00 -3.370162e-04 3.214015e-04 2.061689e-05 2.796715e-05 7.580832e-04 267.06 -2.00 20.00 -2.00 458.40 0.00e+00 1.117768e-03 2.406126e-05 8.422967e-06 1.060402e-05 6.631578e-05 221.44 -2.00 2.40 -2.00 445.61 0.00e+00 4.218130e+06 3.493017e+05 1.579174e+05 3.497313e+05 1.033073e+06 250.97 -2.00 11.50 -2.00 459.53 0.00e+00 1.423250e+00 6.211380e-02 6.982237e-03 1.336660e-02 2.213997e-01 220.62 -2.00 3.85 -2.00 457.72 0.00e+00 3.251464e-06 8.042518e-06 1.655407e-06 1.781313e-06 2.761977e-05 267.06 -2.00 20.00 -2.00 458.09 0.00e+00 13.919 0.060 397.00 473.00 4 5.0337e+00 2.9988e-03 3.7734e-02 6.2333e-04 7.4918e-03 3.2419e-02 4.1555e-03 7.8802e-03 4.5680e-04 9.9890e-03 -5.8360e-03 1.9313e-03 1.0375e-03 1.6212e-04 4.5688e-03 7.6421e-03 8.4487e-04 1.6359e-04 4.4639e-05 1.8015e-03 -3.2800e-03 4.0051e-04 9.9743e-05 2.6423e-05 8.5989e-04 4.9265e-04 -9.4090e-02 1.2754e-03 1.0498e-04 6.4635e-05 3.8065e-03 -3.7610e-04 3.3160e-05 2.2161e-06 5.2215e-07 8.4389e-05 -2.8708e-04 4.9187e-05 3.5521e-06 7.7166e-07 1.1579e-04 -3.3782e-02 3.9464e-04 1.2687e+00 2.7907e-01 1.6517e-02 4.0269e-03 6.7524e-01 12 9 9 12 33 1 97.83 15.95 1.02 -0.03378 -0.01764 4 8 1 2 0 1550.390 15.00 15.95 14.80 21.38 21.38 19.1 999.92 -1434 651 124 -1986 1444 1324 -311 -298 -700 134 -1062 -225 -365 -2553 -2334 -821 -187 -1783 -311 -534 399 641 -860 909 94 2955 -791 236 650 1327 -1401 -1923 -1710 1755 1820 1193 2032 -897 -81 -430 1800 302 1282 -478 1633 -1887 709 -178 -2002 94 800 98 322 203 1373 997 1363 -823 -1119 1428 544 -218 893 387 886 -663 1552 77 -1251 174 -862 1652 404 -196 689 163 -2063 827 -3463 -1120 -8 -28 -1882 788 -482 566 117 -217 208 1282 1629 1287 -568 353 -1647 -274 249 1053 1551 -144 -341 80 2384 487 276 -263 434 1550 979 1605 33 -323 2035 -128 1333 -128 567 646 -846 651 89 -102 -38 140 814 -1102 -12 -623 -495 -1838 138 326 -905 -267 636 -1082 -464 -976 -366 106 60 -464 -15 -1519 469 -546 -184 719 467 348 -336 722 -276 -31 -1926 -801 1487 -609 -397 -196 246 -725 1100 367 579 360 407 -664 244 -884 -1012 321 168 -585 -874 -24 911 -139 499 -364 -151 -632 1131 -1026 -1380 -889 -960 1235 -153 -796 570 -991 -965 1116 -258 -476 -550 64 361 -1361 130 -94 335 -153 -703 -62 -835 -463 -687 99 -123 -370 51 -92 -1130 363 191 -126 846 -5 -181 -183 1239 -672 1557 705 415 477 -178 134 -470 -2016 224 -119 -2802 -547 177 822 -1794 -300 154 296 204 449 -1268 -356 938 403 769 -675 874 145 339 144 78 381 -354 -114 -250 -1368 -1415 -172 -580 26 -697 -656 133 -499 -543 910 874 410 391 144 131 1125 -80 -87 -312 582 720 451 773 213 -840 1434 674 309 759 234 245 209 202 -163 -322 -267 52 347 850 85 512 458 644 228 -98 -318 592 134 -544 522 -335 -230 -357 32 524 645 335 -518 472 336 510 -182 -224 -138 -98 768 -242 29 180 -495 -468 226 -316 -363 -61 -13 -843 215 143 -112 17 471 792 255 99 146 84 303 305 259 31 420 -156 -269 206 -367 54 1016 -135 232 -336 -64 -437 -87 -68 -253 213 -430 -420 48 44 -516 -147 4 -177 -303 371 -144 -303 232 -41 -349 -37 -423 -204 -346 128 -342 -9 134 150 -353 -208 4 296 269 298 -106 -72 141 321 -263 335 -549 122 -1791 269 -43 57 -307 45 261 187 -272 241 -201 -62 255 -55 -362 -135 186 -187 205 -228 250 284 289 -274 245 -174 78 -225 -150 -6 -240 219 443 366 571 -188 92 -218 55 -630 -82 192 -3 90 68 -13 193 -502 -29 -324 -48 -562 370 -130 -24 184 492 38 427 653 499 -5 263 -84 82 -282 -256 -101 -193 -359 349 113 -57 -155 -105 362 -193 -322 46 147 -158 10 -79 40 44 -236 -82 177 63 -106 305 119 76 -364 -103 23 195 81 -31 -20 -201 324 -107 -133 -292 196 -196 -328 -294 193 -192 -163 169 128 204 287 189 -259 500 55 -115 -219 -64 -319 168 288 105 127 -26 27 79 -372 91 246 66 116 59 93 -377 -174 141 900000 -618 281 53 -850 600 553 -134 -132 -318 61 -492 -104 -168 -1204 -1106 -388 -89 -858 -149 -258 192 307 -409 416 42 1307 -369 114 323 667 -721 -982 -844 810 820 542 950 -451 -42 -222 905 151 629 -237 804 -960 351 -88 -987 46 397 51 169 106 715 520 707 -433 -587 738 290 -120 499 218 499 -383 903 43 -715 98 -483 958 232 -111 377 87 -1078 418 -1842 -614 -5 -16 -1082 449 -281 333 71 -134 129 782 986 778 -349 217 -1034 -170 153 641 931 -87 -203 48 1417 303 179 -175 288 999 618 992 21 -208 1318 -85 877 -85 370 419 -556 427 60 -66 -25 94 550 -755 -8 -417 -328 -1217 89 220 -610 -180 405 -712 -308 -653 -244 71 40 -310 -10 -1028 316 -380 -131 511 329 240 -227 475 -182 -21 -1338 -568 1067 -431 -285 -142 178 -533 795 265 412 255 291 -487 180 -652 -719 226 113 -393 -615 -17 668 -105 370 -266 -108 -455 812 -766 -1055 -689 -754 951 -118 -602 418 -738 -729 843 -201 -375 -433 49 275 -1050 101 -72 264 -123 -558 -47 -646 -342 -497 72 -93 -278 40 -73 -900 284 149 -98 650 -4 -135 -136 966 -510 1179 542 315 366 -130 92 -315 -1353 149 -80 -1914 -383 123 573 -1259 -225 119 238 178 390 -1143 -316 833 339 640 -553 720 121 300 127 70 342 -317 -99 -217 -1122 -1157 -137 -476 22 -613 -576 120 -457 -493 799 756 356 345 131 122 1052 -73 -81 -295 555 690 431 731 200 -792 1316 616 280 686 214 228 197 187 -151 -283 -227 45 308 786 78 473 427 606 218 -96 -316 587 133 -539 503 -320 -218 -342 31 501 642 344 -542 487 341 515 -187 -226 -143 -101 784 -246 29 182 -507 -482 232 -326 -372 -62 -13 -879 227 153 -121 18 493 831 273 103 154 88 318 317 275 32 427 -158 -273 211 -383 57 1047 -144 251 -368 -70 -483 -97 -74 -282 239 -491 -478 54 48 -559 -165 4 -200 -350 428 -166 -348 265 -47 -406 -43 -500 -234 -403 151 -408 -11 163 185 -424 -250 5 367 332 366 -130 -88 172 391 -325 413 -682 150 -2208 319 -51 68 -363 54 312 217 -320 288 -246 -77 313 -68 -452 -167 229 -230 258 -287 311 354 363 -348 312 -218 99 -291 -198 -9 -319 289 578 476 745 -249 123 -293 73 -851 -111 261 -5 122 90 -17 250 -652 -37 -427 -64 -764 503 -178 -32 249 662 51 575 881 676 -6 361 -116 114 -397 -365 -141 -272 -507 489 158 -81 -218 -149 513 -277 -464 67 213 -230 14 -115 58 64 -345 -120 257 92 -153 440 172 110 -532 -152 34 285 117 -47 -30 -291 475 -160 -201 -443 297 -299 -509 -445 292 -291 -252 254 189 304 424 282 -382 750 85 -179 -343 -100 -499 260 442 162 197 -39 41 122 -577 140 378 101 179 92 144 -588 -269 215 900000