File name: Pandora186s1_MadisonCT_20221105_L2Fit_fsus1c2d20210922p1-8.txt File generation date: 20251203T184441.9Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 186 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora186_OF_v4d20210803.txt Instrument calibration file used: Pandora186s1_CF_v2d20210922.txt Level 1 file used: Pandora186s1_MadisonCT_20221105_L1_smca1c2d20210922p1-8.txt Full location name: Madison - Hammonasset State Park CTDEEP (USEPA AQS ID 09-009-9002) Short location name: MadisonCT Country of location: USA Location latitude [deg]: 41.2568 Location longitude [deg]: -72.5533 Location altitude [m]: 3 Local noon date: 20221105 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 205 349 Nominal wavelengths inside fitting window [nm]: 306.1389 306.2800 306.4212 306.5623 306.7034 306.8445 306.9856 307.1267 307.2678 307.4089 307.5499 307.6909 307.8320 307.9730 308.1140 308.2550 308.3960 308.5369 308.6779 308.8189 308.9598 309.1007 309.2416 309.3825 309.5234 309.6643 309.8052 309.9460 310.0869 310.2277 310.3685 310.5093 310.6501 310.7909 310.9317 311.0724 311.2132 311.3539 311.4946 311.6354 311.7761 311.9167 312.0574 312.1981 312.3387 312.4794 312.6200 312.7606 312.9012 313.0418 313.1824 313.3230 313.4636 313.6041 313.7447 313.8852 314.0257 314.1662 314.3067 314.4472 314.5876 314.7281 314.8685 315.0090 315.1494 315.2898 315.4302 315.5706 315.7109 315.8513 315.9917 316.1320 316.2723 316.4126 316.5529 316.6932 316.8335 316.9738 317.1140 317.2543 317.3945 317.5347 317.6749 317.8151 317.9553 318.0955 318.2356 318.3758 318.5159 318.6560 318.7961 318.9362 319.0763 319.2164 319.3565 319.4965 319.6366 319.7766 319.9166 320.0566 320.1966 320.3366 320.4765 320.6165 320.7565 320.8964 321.0363 321.1762 321.3161 321.4560 321.5959 321.7357 321.8756 322.0154 322.1552 322.2950 322.4348 322.5746 322.7144 322.8542 322.9939 323.1337 323.2734 323.4131 323.5528 323.6925 323.8322 323.9719 324.1115 324.2512 324.3908 324.5304 324.6700 324.8096 324.9492 325.0888 325.2283 325.3679 325.5074 325.6469 325.7865 325.9260 326.0654 326.2049 326.3444 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-304: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 305-449: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20221105T200653.1Z 8344.838114 11 1 50.38 2 75.38 232.81 95.36 83.35 0.00 1 0.00 1 0 49 7.643e-03 8.203e-04 5.209e-03 5.576e-04 1.141087e-06 2.100330e-07 5.201270e-08 4.931941e-07 3.513862e-06 224.02 -2.00 3.52 -2.00 323.13 0.00e+00 7.446270e-04 8.664388e-05 3.192477e-05 3.573903e-05 9.112662e-04 281.45 -2.00 20.00 -2.00 323.62 0.00e+00 2.627154e-04 1.110294e-04 1.467785e-05 3.328557e-05 1.687153e-03 281.45 -2.00 20.00 -2.00 322.68 0.00e+00 8.602961e-04 2.342271e-04 1.235343e-04 1.128604e-05 1.716803e-03 281.45 -2.00 20.00 -2.00 322.99 0.00e+00 3.851334e-01 1.137161e-03 3.247533e-04 1.538861e-03 1.021097e-02 222.93 0.65 0.00 0.11 17.23 320.73 0.00e+00 -8.227346e-05 1.052493e-04 4.283106e-05 1.908967e-05 2.649243e-04 281.45 -2.00 20.00 -2.00 319.66 0.00e+00 3.882 0.001 303.00 329.40 4 6.0210e-01 2.2120e-03 3.7750e-02 2.5289e-03 3.1245e-02 -2.3514e-02 4.2819e-03 4.3064e-03 3.0626e-04 3.3605e-02 1.5009e-02 2.2717e-03 4.9058e-04 8.8065e-05 1.8211e-02 -1.3400e-02 1.5276e-03 5.0839e-04 1.6703e-04 7.4962e-03 4.0318e-03 8.1746e-04 1.7361e-04 1.3376e-04 5.5749e-03 5.0166e-03 -4.5089e-03 2.8758e-04 9.2431e-05 2.4375e-05 5.7531e-04 -4.5245e-04 1.9917e-05 3.6202e-06 9.8996e-07 2.5133e-04 1.6795e-03 4.8439e-05 -7.4585e-02 3.6533e-02 8.9316e-04 5.0057e-04 4.0543e-01 10 0 0 10 0 0 99.88 21.60 0.27 0.00168 -0.00177 723 135 1 5 0 69.670 24.04 15.00 21.60 24.65 18.4 1030.43 1269 55 2138 -2753 1828 -3193 1997 -3434 3012 -2427 680 -935 593 74 1267 453 -879 951 -1037 676 -929 1898 -309 946 -572 540 -720 555 -376 1204 -395 -155 67 194 1 -358 204 -137 263 -649 315 -325 109 -469 199 -322 286 -51 444 53 -63 61 -60 13 -138 215 -144 298 -119 35 -432 165 -133 235 -97 79 10 33 184 -92 -37 -37 151 30 73 -263 87 -186 7 -168 195 -69 82 43 -22 -113 -83 84 -64 37 22 100 -28 52 -133 58 -18 -5 -69 16 54 72 -15 53 8 -109 41 7 69 -39 39 -39 74 -54 38 -50 -37 -66 11 -63 16 19 14 35 -53 20 -59 7 -16 31 -14 4 13 55 -29 44 -66 -34 -10 23 70 -2 39 -55 -13 31 1 58 -81 57 -122 85 -174 157 -141 41 -59 38 5 84 32 -68 77 -88 55 -73 144 -26 86 -59 59 -80 59 -43 157 -62 -29 13 40 0 -79 45 -31 59 -160 77 -82 29 -124 56 -98 91 -17 150 18 -21 20 -21 5 -56 94 -65 131 -50 14 -190 81 -73 135 -56 44 5 16 80 -43 -16 -19 87 19 52 -198 69 -159 7 -156 181 -62 69 33 -16 -81 -63 72 -61 36 23 106 -28 53 -127 56 -18 -5 -73 18 64 93 -21 76 12 -145 50 8 81 -47 50 -54 103 -74 51 -65 -45 -78 13 -73 20 25 20 53 -83 31 -96 13 -27 55 -25 7 21 88 -46 71 -115 -66 -19 48 157 -4 93 -134 -32 SS 20221105T201056.4Z 8344.840931 14 1 3.04 2 76.00 233.60 94.62 83.99 0.00 1 0.00 1 0 70 4.052e-02 3.685e-03 2.518e-02 3.713e-03 1.158967e-06 1.369407e-06 5.223964e-08 4.930527e-07 1.833058e-05 224.02 -2.00 3.52 -2.00 322.62 0.00e+00 1.021463e-03 5.451304e-04 1.970149e-05 3.573910e-05 4.823229e-03 281.45 -2.00 20.00 -2.00 322.77 0.00e+00 1.483820e-03 7.041832e-04 2.555906e-05 3.334165e-05 8.948822e-03 281.45 -2.00 20.00 -2.00 322.28 0.00e+00 1.623001e-03 1.329197e-03 1.603271e-04 1.030607e-05 9.099387e-03 281.45 -2.00 20.00 -2.00 322.46 0.00e+00 4.033812e-01 6.612642e-03 4.974376e-04 1.539209e-03 5.411762e-02 218.67 3.66 0.00 0.11 92.13 319.80 0.00e+00 -8.187868e-05 5.355614e-04 1.484278e-04 1.911816e-05 1.350533e-03 281.45 -2.00 20.00 -2.00 318.75 0.00e+00 4.040 0.001 303.00 329.40 4 1.8170e+00 1.3670e-02 3.9313e-02 2.5294e-03 1.6571e-01 -1.8925e-02 2.4041e-02 5.1846e-03 3.2141e-04 1.7836e-01 9.5800e-03 1.2839e-02 1.4078e-03 8.0759e-05 9.6536e-02 -5.4553e-03 8.2854e-03 5.1202e-04 1.2221e-04 3.6021e-02 1.1269e-03 4.7309e-03 1.8011e-04 1.1264e-04 2.6960e-02 1.2434e-03 -4.7126e-03 1.2791e-03 6.3264e-05 1.4461e-05 1.7427e-03 1.7575e-04 1.2425e-04 5.1977e-06 9.5296e-07 1.3416e-03 -5.2954e-04 1.8311e-04 4.2939e-01 2.2615e-01 2.3312e-03 4.8279e-04 2.0486e+00 12 9 9 12 1 1 -59.51 21.12 0.26 -0.00053 0.00081 8 29 1 5 0 319.100 23.64 15.00 21.12 24.92 18.1 1030.35 40342 -12498 -3472 -1807 -3698 -7964 -5762 -1499 185 1477 2498 2514 870 5783 -4673 -879 -2992 4845 -2082 2969 -4755 -535 -2530 -2805 -1539 4772 1546 -1121 2170 -1131 1129 -2332 -536 548 992 -45 628 -205 765 -167 1214 12 193 -107 -1110 1785 -1185 216 548 1291 -559 -848 -602 472 -223 -297 408 216 -232 -687 -772 -94 447 466 -103 -773 990 831 1374 -285 -972 -145 -137 19 919 8 -746 -309 -79 230 -145 413 -89 -650 -1105 -107 38 -319 365 57 -98 -224 -9 -38 -309 356 90 -110 109 81 135 -37 294 402 -44 222 -108 -117 375 20 129 145 165 -292 -47 85 -239 37 -83 371 -364 247 -304 -143 152 -335 -128 -47 447 -229 74 -304 83 -62 175 18 -55 127 -463 221 172 98 -210 189 -67 1096 -509 -137 -74 -170 -443 -366 -105 14 117 207 218 79 508 -463 -89 -334 531 -250 333 -549 -59 -305 -376 -226 714 240 -175 349 -199 231 -587 -150 163 307 -14 187 -62 248 -55 394 4 64 -39 -437 730 -528 98 255 601 -262 -394 -285 220 -116 -167 238 123 -126 -374 -444 -57 296 327 -73 -534 629 514 776 -159 -574 -90 -98 14 753 6 -659 -290 -73 221 -140 385 -82 -560 -951 -90 32 -303 369 62 -114 -261 -10 -41 -313 361 97 -121 127 94 168 -48 402 543 -62 295 -142 -145 460 26 168 199 231 -403 -63 109 -308 46 -100 447 -478 336 -426 -210 231 -513 -207 -77 748 -392 127 -510 132 -100 276 29 -92 224 -860 426 344 206 -439 394 -140 SS 20221105T201503.1Z 8344.843786 17 1 50.44 2 76.62 234.39 93.86 84.64 0.00 1 0.00 1 0 49 1.224e-02 8.529e-04 8.374e-03 6.693e-04 2.372158e-06 2.531701e-07 4.041103e-08 4.932716e-07 5.611118e-06 224.02 -2.00 3.52 -2.00 323.34 0.00e+00 9.667333e-04 1.057921e-04 3.877371e-05 3.570101e-05 1.455410e-03 281.45 -2.00 20.00 -2.00 323.86 0.00e+00 4.388617e-04 1.370251e-04 1.782921e-05 3.335982e-05 2.721369e-03 281.45 -2.00 20.00 -2.00 322.84 0.00e+00 4.155657e-04 3.016449e-04 1.514804e-04 1.184762e-05 2.750023e-03 281.45 -2.00 20.00 -2.00 323.17 0.00e+00 4.149662e-01 1.441806e-03 4.847417e-04 1.538515e-03 1.637908e-02 223.00 0.77 0.00 0.11 27.63 321.10 0.00e+00 -3.214315e-04 1.463454e-04 1.450489e-04 1.910170e-05 4.217931e-04 281.45 -2.00 20.00 -2.00 320.06 0.00e+00 4.216 0.001 303.00 329.40 4 5.6044e-01 2.7334e-03 4.1010e-02 2.5298e-03 5.0054e-02 -2.3224e-02 5.4913e-03 5.1910e-03 3.0633e-04 5.3795e-02 1.5475e-02 2.9306e-03 1.1886e-03 9.5515e-05 2.9157e-02 -1.4682e-02 2.0891e-03 3.6243e-04 2.0151e-04 1.1786e-02 4.5770e-03 1.0862e-03 1.5933e-04 1.5180e-04 9.1091e-03 3.7377e-03 -3.8896e-03 3.1718e-04 6.5405e-05 2.3386e-05 6.5207e-04 2.2768e-04 2.4592e-05 5.0080e-06 1.0314e-06 4.0495e-04 -2.8543e-04 1.6047e-04 -5.8637e-02 4.1176e-02 2.3192e-03 6.4140e-04 6.0764e-01 10 0 0 10 0 0 57.02 20.79 0.26 -0.00029 0.00145 634 118 1 5 0 79.540 23.43 15.00 20.79 24.99 18.2 1031.26 2568 8300 -7005 -1 672 1273 71 -1582 -4119 3318 -1851 1652 -2172 2197 -1812 382 -817 -419 415 295 -273 -1265 221 -615 1936 27 1419 -1618 165 -1419 243 -851 597 -409 702 588 -168 736 317 472 248 456 -415 -45 -378 -134 -426 49 -238 367 -50 -108 120 -263 228 -275 -3 10 48 -175 79 -319 202 -77 225 -146 179 13 -83 -62 4 167 62 290 41 -62 -217 16 -222 68 -119 6 82 155 132 50 -101 -83 -31 27 1 -95 139 -72 158 -22 34 -72 -17 -26 54 8 99 -46 -39 46 18 -11 0 24 -17 12 -54 67 -1 42 -112 6 -117 1 41 -34 -7 -42 79 -60 -28 -32 80 -1 99 -79 17 -36 -31 -30 41 -28 27 18 51 9 10 -27 -27 45 150 -151 0 16 35 2 -60 -159 140 -79 72 -101 110 -96 21 -45 -27 27 19 -17 -79 15 -46 157 2 126 -145 16 -156 32 -121 95 -71 126 108 -31 137 60 89 47 89 -87 -10 -94 -36 -120 14 -71 110 -15 -32 36 -85 81 -107 -1 4 18 -66 31 -143 100 -41 119 -75 85 5 -33 -27 2 78 34 175 27 -44 -162 13 -186 58 -104 5 64 113 91 34 -73 -68 -28 28 1 -98 147 -71 145 -20 34 -77 -19 -28 63 9 132 -63 -53 60 22 -12 0 29 -21 17 -74 90 -1 53 -135 7 -143 1 50 -45 -10 -64 124 -100 -45 -55 140 -2 177 -138 28 -63 -53 -53 72 -53 56 37 114 21 25 -66 -67 SS 20221105T202025.0Z 8344.847512 20 1 50.42 2 77.45 235.40 92.87 85.48 0.00 1 0.00 1 0 49 1.555e-02 6.905e-04 1.202e-02 7.973e-04 2.169555e-06 3.046185e-07 1.320690e-07 4.933269e-07 7.129053e-06 224.02 -2.00 3.52 -2.00 323.48 0.00e+00 9.706933e-04 1.280578e-04 5.933778e-05 3.565108e-05 1.848235e-03 281.45 -2.00 20.00 -2.00 324.05 0.00e+00 5.963967e-04 1.663882e-04 2.425448e-05 3.340803e-05 3.468956e-03 281.45 -2.00 20.00 -2.00 322.95 0.00e+00 5.832403e-04 3.768023e-04 1.584636e-04 1.241815e-05 3.493580e-03 281.45 -2.00 20.00 -2.00 323.29 0.00e+00 4.419796e-01 1.787594e-03 4.749325e-04 1.538077e-03 2.083245e-02 224.18 0.90 0.00 0.10 35.13 321.36 0.00e+00 1.061173e-04 1.917894e-04 1.622985e-04 1.909332e-05 5.365445e-04 281.45 -2.00 20.00 -2.00 320.33 0.00e+00 4.473 0.002 303.00 329.40 4 5.8950e-01 3.3625e-03 4.3517e-02 2.5303e-03 6.3621e-02 -1.3093e-02 6.8997e-03 5.7980e-03 3.0547e-04 6.8336e-02 1.1610e-02 3.6712e-03 4.3898e-04 1.0265e-04 3.7067e-02 -1.9014e-02 2.6751e-03 1.6794e-03 2.2848e-04 1.4966e-02 7.9676e-03 1.3785e-03 5.9331e-04 1.6413e-04 1.1672e-02 2.7596e-03 -5.0412e-03 3.2791e-04 1.8810e-04 2.3099e-05 6.9250e-04 9.6461e-05 2.9862e-05 3.8792e-06 1.0810e-06 5.1474e-04 4.0601e-04 1.3074e-04 -6.4314e-02 4.7213e-02 2.7147e-03 6.0132e-04 7.4022e-01 10 0 0 10 0 0 89.25 20.48 0.26 0.00041 0.00114 517 96 1 5 0 97.510 23.11 15.00 20.48 25.09 18.0 1030.86 11133 9503 -6411 1131 1420 1684 2458 -4633 -1336 -456 -2238 338 -2167 -264 -633 -80 -1060 1126 -272 671 -763 284 681 -1652 410 -437 26 -495 1361 -588 642 289 557 -280 812 378 285 65 388 -460 158 -732 17 54 -182 -402 -45 -12 -108 85 15 83 -89 98 -68 -187 264 77 -49 36 -23 -204 102 16 -19 125 62 -213 191 -315 210 -120 130 -72 -19 -34 86 -194 29 51 40 81 9 -13 -4 -66 -48 -56 -118 124 119 34 -62 56 -2 -117 18 -89 -21 -75 77 -13 46 -11 33 16 -21 -75 -24 -7 -7 47 -4 68 20 67 -64 -67 -169 65 70 63 9 51 -19 -19 -57 -45 45 10 -18 10 6 1 41 -5 -21 -66 4 39 48 -12 -29 -31 31 155 144 -114 20 28 38 65 -148 -46 -15 -80 12 -84 -11 -28 -4 -49 60 -15 36 -40 15 38 -107 29 -34 2 -38 110 -56 65 35 77 -42 126 61 46 11 64 -77 27 -129 3 11 -40 -96 -11 -3 -29 23 4 22 -24 28 -22 -66 97 28 -17 13 -8 -85 47 8 -9 59 27 -86 71 -126 81 -53 66 -41 -12 -22 61 -147 23 42 33 64 7 -9 -2 -43 -34 -44 -105 123 128 37 -64 53 -1 -105 17 -91 -22 -86 86 -16 59 -15 44 20 -26 -86 -27 -8 -9 63 -6 90 26 84 -76 -83 -203 79 85 84 13 77 -30 -31 -101 -78 80 18 -32 18 11 2 69 -9 -37 -127 8 89 108 -28 -71 -77 76 SS 20221105T203049.3Z 8344.854737 23 1 50.44 2 79.08 237.34 90.95 87.12 0.00 1 0.00 1 0 49 5.504e-02 1.403e-03 2.855e-02 1.251e-03 2.770765e-06 4.832341e-07 1.044837e-07 4.934530e-07 2.446772e-05 224.02 -2.00 3.52 -2.00 323.73 0.00e+00 9.170823e-04 2.118936e-04 4.433682e-05 3.553658e-05 6.525672e-03 281.45 -2.00 20.00 -2.00 324.40 0.00e+00 7.266347e-04 2.777178e-04 1.953297e-05 3.354756e-05 1.204886e-02 281.45 -2.00 20.00 -2.00 323.19 0.00e+00 4.630645e-04 6.574299e-04 2.302213e-04 1.376349e-05 1.236361e-02 281.45 -2.00 20.00 -2.00 323.55 0.00e+00 4.917611e-01 3.026609e-03 7.472153e-04 1.536973e-03 7.386147e-02 223.46 1.37 0.00 0.09 122.40 321.89 0.00e+00 -4.480410e-04 3.700901e-04 1.686273e-04 1.911968e-05 1.969224e-03 281.45 -2.00 20.00 -2.00 320.91 0.00e+00 5.085 0.002 303.00 329.40 4 7.9328e-01 5.4468e-03 4.9490e-02 2.5314e-03 2.2413e-01 -2.4311e-02 1.1849e-02 6.6854e-03 3.0781e-04 2.4127e-01 1.0538e-02 6.4012e-03 9.9267e-04 1.2394e-04 1.3145e-01 -1.2301e-02 4.9186e-03 1.6520e-03 2.8214e-04 4.9869e-02 5.5457e-03 2.4816e-03 7.0515e-04 1.8702e-04 3.8559e-02 1.2324e-03 -4.8704e-03 4.1417e-04 1.4377e-04 2.0814e-05 1.3538e-03 -5.6566e-04 4.9575e-05 6.5095e-06 1.1941e-06 1.8087e-03 2.0550e-03 3.0505e-05 -1.3909e-01 6.7506e-02 2.4206e-03 5.8798e-04 2.4191e+00 11 8 0 10 0 0 99.88 20.22 0.28 0.00205 -0.00226 282 53 1 5 0 178.850 22.90 15.00 20.22 25.08 17.9 1029.58 -12936 28153 -7597 47749 -4807 4114 -5604 8680 -3191 -10248 206 -8221 -9292 -3128 437 -4512 7488 -5547 4143 -603 3629 -536 2495 127 -687 -2669 -3329 -2011 -1397 -3889 -897 1092 -956 2958 -282 2488 369 2189 438 -640 -408 1350 62 -170 18 -132 -44 481 254 -642 27 359 968 160 214 -89 213 -170 370 -72 138 -305 -316 97 -235 134 -225 190 -566 408 -978 -44 77 96 -41 167 -73 -271 -96 -197 71 103 253 -175 -39 -276 -140 -272 -5 67 172 68 54 19 -86 15 57 25 76 152 -112 162 -68 113 -136 128 63 -18 -51 -118 33 30 129 -36 140 -156 36 -256 71 -203 33 48 65 31 16 -120 22 -42 91 47 -123 -37 37 107 -144 104 -101 33 -45 59 51 22 3 -43 -8 -143 260 -91 430 -66 61 -104 165 -73 -244 5 -216 -255 -91 13 -147 239 -192 150 -22 126 -20 97 6 -35 -138 -192 -113 -84 -250 -67 96 -98 316 -33 289 44 261 54 -81 -53 178 9 -27 3 -25 -9 100 54 -140 6 76 207 37 55 -25 64 -50 106 -21 43 -107 -123 40 -98 54 -84 64 -178 126 -328 -17 34 48 -23 98 -46 -182 -68 -143 52 73 167 -108 -23 -162 -89 -195 -4 62 171 69 52 16 -71 12 50 23 75 161 -127 184 -84 146 -175 158 73 -22 -61 -148 41 39 167 -46 172 -203 45 -307 83 -241 44 64 93 47 26 -201 40 -79 174 92 -242 -71 67 184 -246 183 -193 63 -96 135 127 54 7 -111 -19 SS 20221105T204840.5Z 8344.867135 28 1 50.91 2 81.95 240.57 87.65 89.91 0.00 1 0.00 1 0 81 1.477e-01 7.038e-03 2.514e-01 7.073e-03 1.321265e-06 3.013131e-06 5.431323e-07 4.936839e-07 6.421004e-05 224.02 -2.00 3.52 -2.00 324.27 0.00e+00 6.288843e-03 1.472090e-03 5.200722e-04 3.533317e-05 1.756309e-02 281.45 -2.00 20.00 -2.00 325.09 0.00e+00 9.600647e-04 2.020228e-03 9.836228e-04 3.388801e-05 3.185593e-02 281.45 -2.00 20.00 -2.00 323.68 0.00e+00 1.179190e-02 4.640015e-03 1.642874e-03 1.559848e-05 3.315531e-02 281.45 -2.00 20.00 -2.00 324.12 0.00e+00 5.685903e-01 1.895874e-02 3.717111e-03 1.535357e-03 2.009261e-01 204.89 7.25 0.00 0.08 331.11 322.83 0.00e+00 -5.583137e-03 3.338564e-03 5.864833e-03 1.925618e-05 4.920375e-03 281.45 -2.00 20.00 -2.00 321.96 0.00e+00 6.685 0.005 303.00 329.40 4 1.7274e+00 3.5507e-02 6.9746e-02 2.5299e-03 6.0983e-01 7.4266e-02 7.4121e-02 6.6262e-02 3.3183e-04 6.5390e-01 -3.8505e-01 5.1763e-02 2.1975e-02 1.1901e-04 3.5851e-01 4.2703e-01 3.1840e-02 1.0128e-02 1.8646e-04 1.2154e-01 -1.6460e-01 1.4031e-02 7.3074e-03 1.4087e-04 8.5468e-02 8.9584e-05 4.9386e-02 1.1073e-02 6.9070e-04 4.1048e-06 4.7501e-04 -5.3826e-04 3.2894e-04 7.4984e-05 1.2334e-06 4.8722e-03 3.5279e-03 -4.5838e-05 1.9587e-01 3.3317e-01 4.3411e-02 6.4858e-04 5.2109e+00 12 9 8 11 8 0 99.98 20.10 0.48 0.00353 -0.00058 60 11 1 5 0 848.290 22.90 15.00 20.10 24.87 17.8 1027.69 -49755 -62446 -49520 -29626 -56220 -45617 -10020 -9988 -38876 -2227 -13518 -4370 -6780 16195 -39649 377 -11380 2768 -2120 -22874 -4090 -44357 -37015 -18249 18274 -16666 -7910 -12807 -5677 -13683 2827 3275 30783 29638 25250 16581 9861 17398 3129 4202 -8 4263 -5639 5420 8701 10043 13213 10788 7612 12531 -1167 685 1478 -191 3736 -1400 7777 -712 862 1298 -2850 1566 3892 -3449 -337 -485 881 -2538 -5511 -4964 -2740 -100 -2225 -1164 598 889 -1762 244 -949 248 -2367 104 -2025 -1776 -3251 -1476 -2212 1692 -1045 -256 650 499 399 -653 294 -1463 651 -730 122 162 1390 888 641 724 -298 280 -335 155 483 -130 290 945 341 -359 399 223 -191 34 -312 -20 -123 2 -14 -356 86 -483 -281 -564 363 -42 332 -552 -93 -132 787 132 -43 -287 -697 473 -60 56 63 42 47 -364 -951 -482 -198 -993 -861 -79 -122 -1207 -27 -247 -59 -91 108 -1159 4 -229 40 -35 -543 -44 -1296 -1059 -433 208 -548 -207 -343 -145 -541 114 175 1256 1371 1307 979 624 953 211 279 -1 306 -515 482 826 1033 1416 1261 959 1488 -158 87 187 -27 566 -254 1345 -134 155 237 -595 357 974 -993 -94 -128 210 -564 -1168 -1046 -624 -26 -714 -426 239 377 -817 118 -488 129 -1265 52 -973 -796 -1429 -654 -1100 938 -692 -192 529 411 312 -471 194 -981 457 -556 98 139 1283 914 729 873 -365 331 -377 166 518 -146 345 1165 424 -437 466 252 -208 36 -320 -21 -146 2 -21 -560 142 -851 -483 -1028 673 -79 625 -1014 -176 -238 1374 241 -84 -578 -1553 1144 -159 158 187 126 144 SS 20221105T205911.1Z 8344.874434 31 1 50.16 2 83.69 242.42 85.70 91.56 0.00 1 0.00 1 0 209 1.345e-01 1.057e-02 2.778e-01 1.237e-02 1.247431e-05 5.762428e-06 9.650943e-07 4.937770e-07 5.845851e-05 224.02 -2.00 3.52 -2.00 324.56 0.00e+00 9.411441e-03 2.683926e-03 4.573551e-04 3.543869e-05 1.597916e-02 281.44 -2.00 20.00 -2.00 325.35 0.00e+00 3.001344e-03 3.974332e-03 1.727556e-03 3.415257e-05 2.901822e-02 281.44 -2.00 20.00 -2.00 323.98 0.00e+00 -3.281340e-03 8.669607e-03 2.005041e-03 1.679385e-05 3.018364e-02 281.44 -2.00 20.00 -2.00 324.42 0.00e+00 7.404070e-01 3.900971e-02 7.904653e-03 1.534164e-03 1.819916e-01 232.62 12.16 0.00 0.07 299.69 323.34 0.00e+00 -1.005266e-02 6.180136e-03 8.778196e-03 1.946783e-05 4.474978e-03 281.44 -2.00 20.00 -2.00 322.50 0.00e+00 8.203 0.010 303.00 329.40 4 8.8634e-01 7.8308e-02 8.6997e-02 2.5321e-03 5.5073e-01 6.5657e-01 1.6519e-01 8.4816e-02 3.5174e-04 5.9106e-01 -9.0502e-01 8.8967e-02 3.6511e-02 1.3138e-04 3.2326e-01 7.2689e-01 3.6849e-02 7.6098e-03 1.0352e-04 1.0820e-01 -2.3758e-01 2.2593e-02 5.8363e-03 9.9306e-05 7.8040e-02 4.2526e-05 7.6545e-02 1.6945e-02 3.2799e-09 1.0233e-10 1.4179e-07 9.1131e-04 6.4883e-04 7.7271e-05 1.2672e-06 4.4660e-03 -4.8468e-04 2.1514e-04 4.8282e-01 5.0186e-01 5.7419e-02 4.9937e-04 3.9659e+00 12 9 8 11 8 0 37.20 20.08 0.32 -0.00048 0.00647 44 8 1 5 0 1139.490 22.80 15.00 20.08 24.35 17.9 1023.96 -11093 -2582 19272 -29405 -7669 6879 67559 23426 13686 -2888 18021 22228 -7152 -20913 17064 3089 32108 14201 -21079 27656 1320 -42648 -5613 9091 -17118 25804 -17379 -19308 -2064 -16368 -1258 32382 30998 28018 8794 10972 32567 -6585 32560 4623 14477 -11684 5577 -16128 14255 5513 18721 17497 19591 17989 20717 1697 3362 7296 2276 10638 3674 -3145 -14004 4768 -5281 1807 1396 5779 -818 2226 -2739 -8081 -11457 227 -6359 -4884 2244 -378 2645 -1870 -1065 -1271 3925 -2571 -3082 -3404 -2032 -7785 -5050 -1152 -1483 -362 -1019 3718 865 2531 -1261 1969 1074 -1219 -3906 900 339 435 212 2216 2372 162 1201 1346 -551 -1648 -179 41 48 205 -483 3 828 -861 1415 -691 -63 -813 -27 -340 -1177 -215 -208 -400 -102 -375 -355 955 -320 700 73 -169 401 -279 -583 -677 659 620 466 -16 -540 296 -238 -339 -69 266 -1221 -232 182 791 575 431 -121 480 485 -260 -864 282 82 439 342 -945 324 22 -1700 -112 155 -651 381 -666 -686 -55 -737 -58 1095 1312 1344 569 659 1268 -451 1120 253 688 -875 363 -1608 1056 507 1573 1582 1781 1654 1722 168 318 694 260 1228 492 -453 -2250 639 -885 325 286 1190 -180 447 -526 -1464 -1980 34 -1163 -1055 538 -108 817 -648 -389 -495 1515 -1090 -1311 -1406 -778 -2981 -1833 -419 -610 -172 -571 2277 599 1746 -857 1187 603 -697 -2443 572 230 318 171 1951 2317 172 1287 1406 -562 -1642 -177 42 53 233 -554 4 876 -894 1383 -670 -60 -818 -30 -433 -1669 -325 -334 -686 -187 -726 -704 1894 -641 1340 134 -294 681 -496 -1128 -1449 1534 1583 1302 -48 -1708 955 -791