File name: Pandora127s1_Mainz-MPIC_20251012_L2Fit_fwvt1c7d20250721p1-8.txt File generation date: 20251012T231856.8Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c7p1-8 Local principal investigator: Thomas Wagner Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 127 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora127_OF_v4d20210611.txt Instrument calibration file used: Pandora127s1_CF_v7d20250721.txt Level 1 file used: Pandora127s1_Mainz-MPIC_20251012_L1_smca1c7d20250721p1-8.txt Full location name: Max-Planck-Institute for Chemistry, Mainz Short location name: Mainz-MPIC Country of location: Germany Location latitude [deg]: 49.9910 Location longitude [deg]: 8.2280 Location altitude [m]: 125 Local noon date: 20251012 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1649 1799 Nominal wavelengths inside fitting window [nm]: 492.0928 492.2131 492.3335 492.4538 492.5741 492.6944 492.8147 492.9349 493.0552 493.1754 493.2956 493.4158 493.5360 493.6562 493.7763 493.8964 494.0165 494.1366 494.2567 494.3768 494.4968 494.6168 494.7368 494.8568 494.9768 495.0968 495.2167 495.3366 495.4565 495.5764 495.6963 495.8161 495.9360 496.0558 496.1756 496.2954 496.4151 496.5349 496.6546 496.7743 496.8940 497.0137 497.1334 497.2530 497.3727 497.4923 497.6119 497.7315 497.8510 497.9706 498.0901 498.2096 498.3291 498.4486 498.5680 498.6875 498.8069 498.9263 499.0457 499.1651 499.2844 499.4038 499.5231 499.6424 499.7617 499.8810 500.0002 500.1195 500.2387 500.3579 500.4771 500.5962 500.7154 500.8345 500.9536 501.0727 501.1918 501.3109 501.4299 501.5490 501.6680 501.7870 501.9059 502.0249 502.1439 502.2628 502.3817 502.5006 502.6195 502.7383 502.8572 502.9760 503.0948 503.2136 503.3324 503.4511 503.5699 503.6886 503.8073 503.9260 504.0446 504.1633 504.2819 504.4005 504.5191 504.6377 504.7563 504.8748 504.9934 505.1119 505.2304 505.3489 505.4673 505.5858 505.7042 505.8226 505.9410 506.0594 506.1777 506.2961 506.4144 506.5327 506.6510 506.7693 506.8875 507.0057 507.1240 507.2422 507.3604 507.4785 507.5967 507.7148 507.8329 507.9510 508.0691 508.1872 508.3052 508.4232 508.5413 508.6593 508.7772 508.8952 509.0131 509.1311 509.2490 509.3669 509.4847 509.6026 509.7204 509.8382 509.9560 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-252: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 253-403: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20251012T144124.8Z 9416.612093 511 1 28.59 2 73.11 234.69 99.47 337.56 0.00 1 0.00 1 0 15 3.528e-03 3.491e-03 5.575e-04 5.564e-04 3.448535e+03 3.279776e+01 2.574643e+02 -6.000000e+00 1.866152e+02 277.34 -2.00 20.00 -2.00 505.27 0.00e+00 6.687980e-04 1.491009e-05 4.049062e-05 -6.000000e+00 9.641910e-05 277.34 -2.00 20.00 -2.00 500.44 0.00e+00 1.761230e-01 1.084215e-02 2.473847e-02 -6.000000e+00 6.882782e-02 225.04 -2.00 3.76 -2.00 502.04 0.00e+00 3.389 0.001 489.00 513.00 1 5.8486e+00 8.2839e-04 5.3059e-03 -6.0000e+00 5.2601e-03 1.4719e-02 2.1522e-04 6.5968e-04 -6.0000e+00 1.3766e-03 3.4213e-03 2.8474e-04 4.9619e-05 3.5754e-05 -6.0000e+00 3.2525e-04 5.6594e-03 -7.7620e-05 12 1 1 12 1 1 95.29 20.61 1.90 0.00566 0.00763 32 13 1 2 0 866.310 20.00 20.61 22.11 25.47 25.39 0.1 958.46 -602 -467 -164 79 51 500 464 447 470 491 305 42 -193 -330 -472 -437 -231 96 34 -147 208 181 159 217 269 408 463 157 -473 -607 -449 -418 -106 431 148 43 293 107 -60 -155 -60 -47 166 208 302 386 309 418 161 -80 -520 -731 -1655 -494 -350 -226 -170 80 81 85 267 435 345 513 408 209 212 14 -96 -377 -341 -226 -153 138 14 -93 -297 -153 -320 -376 -565 -430 -407 -253 -44 -295 -198 -142 -90 -111 -139 268 454 365 498 435 309 38 -284 -715 -866 -598 -421 26 47 -201 -116 -216 -259 -169 -23 -39 108 218 248 386 621 616 404 347 181 12 38 300 179 131 289 292 136 405 264 -120 -117 -232 -446 -326 -30 -208 -77 64 103 62 265 279 397 283 162 -239 -486 -441 -389 -597 -456 -165 83 53 524 494 480 503 516 317 43 -195 -330 -470 -438 -235 100 37 -153 217 189 166 227 283 427 483 162 -494 -613 -445 -416 -107 453 155 45 306 110 -61 -162 -63 -48 170 216 316 405 323 430 163 -82 -518 -710 -1601 -476 -347 -231 -172 82 82 86 271 443 353 523 414 209 209 15 -96 -371 -332 -221 -151 137 14 -94 -295 -148 -308 -360 -543 -416 -397 -249 -44 -286 -193 -138 -87 -108 -136 264 455 368 498 427 297 37 -269 -666 -800 -557 -403 25 46 -203 -116 -213 -251 -164 -22 -39 109 215 246 384 620 618 405 343 182 12 37 293 177 130 285 288 134 398 259 -116 -112 -218 -417 -307 -29 -204 -77 63 101 62 263 278 396 282 159 -231 -474 -423 -374 SQ 20251012T145659.4Z 9416.622910 519 1 2.80 2 75.19 238.06 100.33 340.77 0.00 1 0.00 1 0 15 4.272e-03 4.248e-03 2.009e-03 2.006e-03 3.644207e+03 1.181972e+02 2.744674e+02 -6.000000e+00 2.259690e+02 277.34 -2.00 20.00 -2.00 505.27 0.00e+00 8.260124e-04 5.369309e-05 4.834638e-05 -6.000000e+00 1.167552e-04 277.34 -2.00 20.00 -2.00 500.47 0.00e+00 2.871874e-01 3.903722e-02 2.593728e-02 -6.000000e+00 8.335209e-02 225.04 -2.00 3.76 -2.00 502.05 0.00e+00 3.835 0.001 489.00 513.00 1 5.7759e+00 2.9812e-03 5.9501e-03 -6.0000e+00 6.3700e-03 1.2754e-02 7.7521e-04 7.0260e-04 -6.0000e+00 1.6672e-03 3.4190e-03 5.7597e-04 1.7882e-04 3.9772e-05 -6.0000e+00 3.9388e-04 4.6116e-03 -7.9033e-05 12 9 1 12 1 1 999.00 20.60 1.85 0.00461 0.00861 2 12 1 2 0 932.160 20.00 20.60 22.03 25.47 25.39 0.1 957.60 -628 -490 -96 188 -74 708 531 418 440 401 175 126 -392 -491 -533 -311 0 78 216 108 431 36 351 418 672 461 303 262 -495 -576 -572 -341 -165 80 -12 -27 41 -95 -409 -219 85 23 223 270 774 118 580 235 276 140 -188 -990 -1786 -495 -387 -218 -263 453 -52 97 -133 628 673 478 -9 -55 110 -231 130 -337 -599 -475 -82 172 126 -64 -198 -451 -438 -442 -496 -604 -646 -10 -24 14 -116 -247 -74 -380 201 67 897 276 317 426 131 189 154 -943 -851 -833 -681 -352 -140 58 203 -388 -584 -421 -107 41 -7 101 268 714 1157 560 584 275 382 360 322 176 24 4 253 330 -84 555 165 196 -570 98 -46 -245 -305 -129 186 98 72 79 506 167 586 -8 206 -224 -783 -691 -281 -613 -478 -97 191 -76 733 560 435 465 418 180 128 -402 -498 -538 -315 0 81 223 113 450 38 367 438 706 485 318 271 -513 -577 -575 -344 -166 82 -13 -28 43 -98 -420 -222 87 24 230 281 811 122 607 244 280 142 -186 -980 -1758 -484 -381 -221 -268 463 -54 99 -137 642 690 492 -9 -55 109 -231 129 -330 -582 -462 -80 171 127 -64 -195 -436 -428 -430 -484 -582 -627 -10 -24 14 -114 -242 -73 -373 197 67 899 274 319 420 127 182 147 -893 -798 -789 -649 -341 -140 57 203 -384 -571 -411 -106 40 -7 101 271 720 1169 561 584 277 378 351 316 173 24 4 247 321 -82 537 160 191 -550 93 -43 -232 -295 -125 182 97 71 78 500 167 584 -8 203 -221 -757 -658 -273 SQ 20251012T155148.2Z 9416.660974 545 1 26.93 2 83.10 249.32 102.32 352.35 0.00 1 0.00 1 0 22 4.730e-03 4.673e-03 1.401e-04 1.399e-04 7.621438e+03 8.795264e+00 5.418975e+02 -6.000000e+00 2.501982e+02 277.34 -2.00 20.00 -2.00 505.34 0.00e+00 1.446005e-03 3.764960e-06 8.455317e-05 -6.000000e+00 1.292701e-04 277.34 -2.00 20.00 -2.00 500.70 0.00e+00 5.787477e-01 2.706281e-03 5.464001e-02 -6.000000e+00 9.227414e-02 225.03 -2.00 3.76 -2.00 502.25 0.00e+00 7.620 0.009 489.00 513.00 1 2.4064e+00 2.0642e-04 1.1930e-02 -6.0000e+00 7.0520e-03 -1.7267e-02 5.3073e-05 1.4631e-03 -6.0000e+00 1.8453e-03 5.6346e-02 4.9112e-04 1.2251e-05 7.6011e-05 -6.0000e+00 4.3606e-04 5.9583e-03 -7.4564e-05 12 8 8 10 0 0 94.04 20.58 1.66 0.00596 0.00936 534 125 1 2 0 50.240 20.02 20.58 22.50 25.47 25.39 0.0 960.89 -1061 -751 -295 -38 200 634 716 631 589 340 282 -34 -368 -455 -636 -542 -230 65 130 53 202 209 186 428 428 500 524 257 -372 -619 -623 -641 -202 408 297 252 279 92 -93 -167 -52 17 202 433 564 535 531 428 202 -228 -656 -914 -1913 -823 -372 -142 44 156 186 251 394 539 524 557 461 276 177 11 -245 -491 -505 -332 -301 34 104 -204 -376 -432 -573 -659 -612 -593 -560 -354 -143 -236 -234 -164 -179 -94 53 424 661 647 600 608 382 -22 -413 -959 -1118 -946 -556 -12 27 -157 -167 -406 -484 -242 -135 -54 207 382 444 677 897 905 621 443 230 40 83 350 300 207 349 297 269 455 263 -91 -148 -421 -653 -366 -170 -235 -68 222 133 157 332 333 426 353 30 -344 -637 -751 -626 -1008 -701 -284 -38 197 635 729 648 603 344 282 -34 -359 -440 -613 -525 -226 65 134 54 203 212 188 434 437 510 533 259 -380 -613 -606 -628 -202 408 306 261 287 94 -94 -167 -52 17 206 447 588 560 553 441 205 -226 -658 -896 -1872 -804 -372 -142 45 161 192 259 405 557 544 579 476 282 178 11 -241 -478 -487 -320 -294 33 104 -204 -370 -417 -547 -627 -583 -569 -543 -346 -141 -236 -234 -164 -179 -94 53 428 654 643 588 602 368 -21 -395 -903 -1045 -894 -523 -12 27 -157 -167 -401 -474 -237 -133 -54 211 391 456 698 901 918 633 448 236 40 83 349 302 209 353 301 272 459 265 -91 -145 -409 -635 -359 -170 -233 -68 226 137 162 346 349 447 370 31 -351 -637 -742 -621 SQ 20251012T155215.2Z 9416.661287 545 2 26.93 2 83.17 249.41 102.33 352.44 0.00 1 0.00 1 0 22 4.825e-03 4.766e-03 1.519e-04 1.517e-04 7.691218e+03 9.549612e+00 5.448139e+02 -6.000000e+00 2.552684e+02 277.34 -2.00 20.00 -2.00 505.33 0.00e+00 1.463173e-03 4.077419e-06 8.583834e-05 -6.000000e+00 1.318869e-04 277.34 -2.00 20.00 -2.00 500.66 0.00e+00 5.843414e-01 2.930693e-03 5.530794e-02 -6.000000e+00 9.412837e-02 225.03 -2.00 3.76 -2.00 502.22 0.00e+00 7.683 0.010 489.00 513.00 1 2.5328e+00 2.2378e-04 1.2042e-02 -6.0000e+00 7.1940e-03 -1.8329e-02 5.7497e-05 1.4750e-03 -6.0000e+00 1.8821e-03 4.9181e-02 3.1011e-04 1.3239e-05 7.6289e-05 -6.0000e+00 4.4485e-04 3.5285e-03 -4.8110e-05 12 8 8 10 0 0 99.13 20.58 1.65 0.00353 0.00568 534 125 1 2 0 50.240 20.00 20.58 22.56 25.47 25.39 0.0 960.89 -1082 -783 -319 -41 195 659 718 641 600 335 265 -34 -371 -460 -611 -506 -219 102 159 57 188 185 202 411 452 465 527 231 -371 -673 -710 -686 -228 417 320 262 331 114 -73 -154 -44 2 236 417 566 540 512 445 239 -192 -697 -940 -1924 -816 -380 -136 58 176 182 281 432 554 560 595 478 276 213 14 -238 -520 -513 -391 -310 49 98 -213 -315 -394 -609 -659 -620 -592 -607 -381 -152 -227 -208 -148 -166 -112 82 447 715 634 638 607 340 -32 -432 -973 -1168 -942 -576 -16 -20 -127 -161 -396 -498 -262 -143 -40 233 380 501 667 927 885 631 400 203 52 82 362 264 223 391 301 287 481 283 -91 -177 -374 -689 -405 -165 -231 -28 235 188 177 331 351 409 363 23 -353 -669 -732 -652 -1017 -750 -303 -40 196 676 721 649 605 334 271 -34 -371 -455 -602 -502 -221 101 162 58 194 191 209 426 472 486 548 238 -374 -658 -683 -664 -225 426 325 267 335 119 -75 -158 -45 2 238 425 582 557 526 452 239 -195 -691 -910 -1859 -787 -376 -139 59 179 186 285 437 564 573 610 487 278 211 14 -240 -519 -507 -386 -310 48 96 -210 -305 -389 -595 -641 -605 -581 -601 -367 -147 -223 -205 -146 -163 -110 81 446 721 643 638 593 323 -31 -408 -904 -1079 -880 -554 -16 -20 -126 -159 -399 -497 -261 -144 -40 234 383 507 678 949 916 655 412 206 52 81 355 261 222 390 300 286 479 282 -89 -172 -359 -661 -392 -163 -233 -29 244 191 181 339 362 423 375 24 -355 -682 -737 -659 SQ 20251012T160717.7Z 9416.671733 549 1 48.58 2 85.45 252.37 102.58 355.67 0.00 1 0.00 1 0 22 6.066e-03 5.985e-03 1.557e-04 1.554e-04 1.056002e+04 1.014085e+01 7.329424e+02 -6.000000e+00 3.208772e+02 277.33 -2.00 20.00 -2.00 505.37 0.00e+00 2.054246e-03 4.181966e-06 1.188928e-04 -6.000000e+00 1.657858e-04 277.33 -2.00 20.00 -2.00 500.79 0.00e+00 7.747706e-01 2.989951e-03 7.524843e-02 -6.000000e+00 1.183291e-01 225.03 -2.00 3.76 -2.00 502.33 0.00e+00 10.519 0.025 489.00 513.00 1 2.7433e+00 2.2809e-04 1.6733e-02 -6.0000e+00 9.0434e-03 -2.8754e-02 5.8275e-05 2.0202e-03 -6.0000e+00 2.3661e-03 2.6074e-02 5.7238e-04 1.3379e-05 1.0151e-04 -6.0000e+00 5.5921e-04 5.8063e-03 -6.6372e-05 12 8 8 10 0 0 93.26 20.57 2.18 0.00581 0.00978 512 120 1 2 0 94.860 20.02 20.57 23.08 25.47 25.39 0.0 964.89 -1414 -1009 -425 -34 260 786 882 851 722 460 280 -81 -523 -659 -822 -706 -308 96 238 140 290 273 296 520 549 622 635 281 -444 -821 -894 -857 -307 462 408 343 399 104 -115 -190 -57 53 310 569 725 736 664 529 254 -260 -804 -1129 -2126 -1030 -464 -60 168 315 333 386 522 714 684 729 595 335 165 -43 -306 -654 -674 -520 -387 -28 45 -287 -536 -618 -800 -890 -826 -727 -695 -464 -211 -305 -244 -232 -230 -117 102 532 880 859 767 740 432 -13 -553 -1226 -1465 -1199 -756 -102 78 -83 -205 -483 -566 -352 -177 -6 314 511 635 919 1200 1139 844 586 267 70 82 417 398 328 460 416 346 543 301 -112 -274 -551 -875 -529 -230 -221 -7 266 251 224 355 413 515 457 95 -387 -822 -954 -846 -1316 -919 -400 -33 259 765 874 850 719 453 273 -78 -499 -648 -806 -669 -297 95 241 143 297 280 304 536 549 623 633 289 -447 -803 -861 -831 -304 472 414 350 404 104 -114 -188 -56 53 314 584 751 765 687 542 256 -258 -778 -1110 -2089 -1011 -450 -60 171 326 344 397 538 740 713 733 617 344 167 -43 -303 -643 -657 -507 -381 -28 45 -290 -532 -602 -772 -855 -794 -704 -678 -457 -210 -307 -247 -233 -231 -117 103 520 871 852 749 728 413 -12 -506 -1152 -1369 -1092 -711 -100 77 -84 -207 -483 -560 -349 -178 -6 323 528 658 922 1215 1169 873 602 270 72 83 422 407 326 458 416 345 542 300 -111 -277 -552 -877 -535 -229 -225 -7 278 266 231 369 432 539 477 98 -408 -853 -981 -874 SQ 20251012T161223.9Z 9416.675276 552 1 48.57 2 86.24 253.36 102.63 356.77 0.00 1 0.00 1 0 22 6.733e-03 6.636e-03 3.005e-04 2.997e-04 1.187586e+04 1.992046e+01 8.161504e+02 -6.000000e+00 3.561662e+02 277.33 -2.00 20.00 -2.00 505.40 0.00e+00 2.336858e-03 8.093730e-06 1.356260e-04 -6.000000e+00 1.840139e-04 277.33 -2.00 20.00 -2.00 500.87 0.00e+00 8.785007e-01 5.772285e-03 8.490769e-02 -6.000000e+00 1.312736e-01 225.03 -2.00 3.76 -2.00 502.40 0.00e+00 11.920 0.036 489.00 513.00 1 3.7696e+00 4.4050e-04 1.9214e-02 -6.0000e+00 1.0034e-02 -2.9859e-02 1.1186e-04 2.2875e-03 -6.0000e+00 2.6236e-03 7.5736e-03 -8.8052e-05 2.5646e-05 1.1014e-04 -6.0000e+00 6.2051e-04 1.5430e-03 -4.5986e-06 12 8 8 10 0 0 99.63 20.58 2.69 0.00154 0.00093 188 44 1 2 0 258.300 20.04 20.58 23.15 25.47 25.39 0.0 965.10 -1635 -1193 -426 -40 337 846 971 898 799 443 287 -74 -535 -712 -913 -718 -340 167 214 209 321 295 314 489 563 619 701 272 -457 -965 -1003 -995 -339 433 455 467 400 159 -123 -100 -75 74 330 651 858 851 732 593 276 -327 -845 -1291 -2287 -1188 -496 -84 227 401 435 481 501 749 738 811 620 404 136 -42 -335 -691 -745 -659 -482 -38 77 -318 -524 -744 -900 -1038 -928 -777 -779 -476 -289 -240 -351 -142 -344 -118 127 593 1001 937 955 771 442 -56 -560 -1395 -1634 -1413 -817 -105 26 -14 -216 -543 -708 -406 -249 13 393 575 712 1011 1297 1282 917 564 253 0 81 422 450 367 481 403 338 560 331 -159 -368 -555 -937 -587 -274 -265 60 302 324 227 427 400 560 486 113 -447 -915 -1097 -956 -1453 -1082 -398 -38 333 814 950 886 786 432 276 -70 -505 -696 -892 -674 -324 163 214 211 325 300 319 500 580 639 720 277 -456 -938 -960 -960 -334 440 456 471 401 158 -122 -98 -74 73 332 661 880 877 752 603 277 -323 -812 -1271 -2249 -1167 -478 -84 231 412 447 493 515 772 766 842 641 413 137 -41 -331 -677 -725 -642 -474 -38 78 -320 -519 -724 -866 -995 -890 -750 -758 -467 -287 -241 -354 -142 -343 -117 126 598 1019 919 958 751 418 -52 -507 -1304 -1520 -1276 -762 -103 25 -14 -216 -539 -697 -400 -249 13 401 590 732 1042 1349 1353 939 574 264 0 82 425 457 376 494 415 348 576 341 -162 -371 -554 -939 -594 -283 -268 62 314 342 241 457 431 605 524 121 -471 -950 -1129 -988