File name: Pandora138s1_Milan-MIBI_20260118_L2Fit_fwvt1c22d20250714p1-8.txt File generation date: 20260118T233645.1Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c22p1-8 Local principal investigator: Stefano Casadio Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 138 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora138_OF_v3d20210407.txt Instrument calibration file used: Pandora138s1_CF_v22d20250714.txt Level 1 file used: Pandora138s1_Milan-MIBI_20260118_L1_smca1c22d20250714p1-8.txt Full location name: University Milano Bicocca, building U9 Short location name: Milan-MIBI Country of location: Italy Location latitude [deg]: 45.5090 Location longitude [deg]: 9.2080 Location altitude [m]: 150 Local noon date: 20260118 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1629 1778 Nominal wavelengths inside fitting window [nm]: 492.1148 492.2359 492.3571 492.4782 492.5993 492.7204 492.8415 492.9625 493.0836 493.2046 493.3256 493.4466 493.5676 493.6885 493.8095 493.9304 494.0513 494.1722 494.2931 494.4139 494.5347 494.6556 494.7764 494.8972 495.0179 495.1387 495.2594 495.3801 495.5008 495.6215 495.7422 495.8629 495.9835 496.1041 496.2247 496.3453 496.4659 496.5864 496.7070 496.8275 496.9480 497.0685 497.1889 497.3094 497.4298 497.5502 497.6706 497.7910 497.9114 498.0317 498.1520 498.2724 498.3927 498.5129 498.6332 498.7534 498.8737 498.9939 499.1141 499.2343 499.3544 499.4746 499.5947 499.7148 499.8349 499.9550 500.0750 500.1951 500.3151 500.4351 500.5551 500.6751 500.7950 500.9150 501.0349 501.1548 501.2747 501.3946 501.5144 501.6343 501.7541 501.8739 501.9937 502.1134 502.2332 502.3529 502.4726 502.5923 502.7120 502.8317 502.9514 503.0710 503.1906 503.3102 503.4298 503.5493 503.6689 503.7884 503.9079 504.0274 504.1469 504.2664 504.3858 504.5052 504.6247 504.7440 504.8634 504.9828 505.1021 505.2215 505.3408 505.4600 505.5793 505.6986 505.8178 505.9370 506.0562 506.1754 506.2946 506.4138 506.5329 506.6520 506.7711 506.8902 507.0093 507.1283 507.2473 507.3664 507.4854 507.6043 507.7233 507.8422 507.9612 508.0801 508.1990 508.3179 508.4367 508.5556 508.6744 508.7932 508.9120 509.0308 509.1495 509.2683 509.3870 509.5057 509.6244 509.7430 509.8617 509.9803 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20260118T114214.6Z 9514.487669 189 1 43.25 2 66.02 182.22 71.38 185.33 0.00 1 0.00 1 0 15 2.038e-03 2.035e-03 5.152e-04 5.145e-04 2.086860e+03 3.117294e+01 1.518455e+02 -6.000000e+00 1.154639e+02 270.60 -2.00 20.00 -2.00 505.28 0.00e+00 5.392135e-04 1.414717e-05 3.414430e-05 -6.000000e+00 5.715408e-05 270.60 -2.00 20.00 -2.00 500.51 0.00e+00 8.844886e-02 1.049797e-02 1.886046e-02 -6.000000e+00 4.177226e-02 223.30 -2.00 3.61 -2.00 502.10 0.00e+00 2.443 0.000 489.00 513.00 1 6.8704e+00 8.0565e-04 3.8513e-03 -6.0000e+00 3.2068e-03 1.2111e-02 2.0292e-04 4.7189e-04 -6.0000e+00 8.1184e-04 1.4244e-03 7.7664e-04 6.3987e-05 2.3133e-05 -6.0000e+00 2.6105e-04 4.5112e-03 -4.8768e-05 10 0 0 10 0 0 99.16 17.72 0.56 0.00451 0.00990 31 8 1 2 0 1394.960 15.00 17.72 17.45 21.27 20.87 22.1 963.81 354 352 270 14 -23 114 172 109 93 118 165 140 -49 59 326 161 -8 17 -164 -214 43 126 172 211 -7 -97 -38 -136 -377 101 473 -2 -89 -53 -346 -485 -188 -9 88 250 211 179 149 -60 5 -182 -168 -45 -268 -152 -121 187 -2 -15 -92 -346 -379 -162 -17 98 243 127 -31 -38 36 -61 -65 81 38 -129 -103 -73 -218 -279 -339 -390 -70 180 -7 -185 -27 -229 -274 -116 57 -253 -169 32 127 -60 50 183 -56 -302 -272 112 -10 -152 -95 118 -24 -260 -380 -489 -689 -352 29 144 351 266 1 -23 185 163 254 298 304 117 41 272 363 241 385 213 -49 203 42 50 217 74 -170 244 398 17 44 110 -112 -320 -118 -11 -19 106 134 -110 -10 -81 -31 34 184 -38 349 343 271 14 -24 119 177 113 95 123 170 142 -49 59 325 163 -9 18 -170 -224 45 132 181 222 -8 -102 -40 -139 -388 102 472 -2 -92 -55 -361 -509 -196 -9 90 254 215 183 154 -63 5 -191 -174 -46 -269 -152 -118 185 -2 -15 -92 -345 -384 -165 -17 100 248 130 -32 -39 36 -61 -66 81 37 -126 -100 -72 -215 -278 -337 -385 -68 173 -7 -177 -26 -222 -268 -114 56 -246 -164 31 124 -59 50 184 -57 -304 -271 109 -10 -145 -90 114 -23 -252 -367 -483 -689 -351 29 141 343 262 1 -23 184 163 256 302 307 118 41 268 362 239 379 211 -48 202 42 50 213 72 -165 233 375 16 42 106 -110 -311 -116 -11 -19 106 134 -110 -10 -79 -30 33 177 -37 SQ 20260118T115449.8Z 9514.496409 197 1 9.13 2 66.17 185.44 71.60 188.25 0.00 1 0.00 1 0 15 1.978e-03 1.981e-03 1.352e-04 1.350e-04 2.024225e+03 8.151462e+00 1.503357e+02 -6.000000e+00 1.120999e+02 270.60 -2.00 20.00 -2.00 505.28 0.00e+00 5.845978e-04 3.708133e-06 3.553225e-05 -6.000000e+00 5.548667e-05 270.60 -2.00 20.00 -2.00 500.55 0.00e+00 8.773738e-02 2.748660e-03 1.803131e-02 -6.000000e+00 4.053622e-02 223.30 -2.00 3.61 -2.00 502.12 0.00e+00 2.457 0.000 489.00 513.00 1 2.6387e+00 2.1084e-04 3.8507e-03 -6.0000e+00 3.1121e-03 4.4380e-03 5.3143e-05 4.5827e-04 -6.0000e+00 7.8736e-04 9.7830e-02 -1.2805e-04 1.6785e-05 2.4174e-05 -6.0000e+00 2.5340e-04 1.5924e-03 9.2293e-06 12 1 1 12 1 1 78.65 17.74 0.62 0.00159 0.00070 417 117 1 2 0 21.480 15.00 17.74 17.99 21.27 20.87 22.2 967.47 297 229 253 41 -59 158 215 180 76 105 236 82 -55 114 253 63 -29 18 -178 -292 13 178 147 255 54 -138 -50 -155 -292 141 468 101 -56 4 -407 -555 -181 100 86 166 215 135 36 45 -19 -129 -159 -79 -121 -267 -56 66 33 2 -144 -399 -369 -244 -15 113 244 153 19 21 -31 -31 30 55 -102 -106 77 -109 -307 -228 -301 -367 -165 61 -30 -95 -30 -171 -284 -49 -17 -196 -188 46 193 103 70 176 27 -248 -138 26 -33 -160 -27 104 -25 -280 -342 -513 -705 -411 -24 114 284 268 22 -51 70 166 207 286 293 127 102 364 308 258 362 236 -47 96 136 39 157 91 -168 100 288 75 17 186 -117 -258 -91 35 71 130 99 -31 -80 -129 -92 6 163 -8 289 227 250 42 -60 164 221 186 79 107 243 84 -55 115 257 63 -29 18 -184 -305 13 187 154 268 55 -145 -52 -158 -299 141 465 102 -56 4 -418 -572 -189 103 88 170 219 139 38 46 -19 -132 -162 -81 -122 -268 -55 66 33 2 -144 -401 -376 -250 -16 116 250 158 19 21 -31 -31 29 55 -101 -103 75 -107 -304 -228 -301 -364 -161 59 -29 -92 -29 -166 -279 -48 -16 -193 -185 46 191 102 70 174 27 -248 -139 26 -32 -155 -26 98 -24 -272 -335 -513 -699 -407 -24 113 281 262 22 -52 71 166 208 289 295 127 101 364 305 254 355 232 -46 94 134 39 154 88 -165 97 276 72 17 181 -114 -256 -89 35 70 130 99 -31 -80 -127 -90 6 157 -8 SQ 20260118T121310.2Z 9514.509146 204 1 42.20 2 66.60 190.10 72.13 192.46 0.00 1 0.00 1 0 15 2.461e-03 2.448e-03 1.057e-03 1.055e-03 2.175556e+03 6.418429e+01 1.608864e+02 -6.000000e+00 1.394275e+02 270.60 -2.00 20.00 -2.00 505.26 0.00e+00 6.087222e-04 2.902334e-05 3.731473e-05 -6.000000e+00 6.905475e-05 270.60 -2.00 20.00 -2.00 500.46 0.00e+00 1.410635e-01 2.155069e-02 1.749840e-02 -6.000000e+00 5.059550e-02 223.30 -2.00 3.61 -2.00 502.05 0.00e+00 2.499 0.000 489.00 513.00 1 8.2267e+00 1.6537e-03 3.8999e-03 -6.0000e+00 3.8819e-03 1.1458e-02 4.1694e-04 4.5685e-04 -6.0000e+00 9.8697e-04 3.6222e-04 5.9262e-03 1.3088e-04 2.6175e-05 -6.0000e+00 3.1552e-04 3.0253e-02 -4.6261e-04 10 0 0 10 0 0 97.05 17.78 0.40 0.03025 0.07136 12 3 1 2 0 3516.380 15.00 17.78 19.01 21.27 20.96 22.1 971.99 156 525 336 -125 -70 46 155 90 178 376 -11 32 -48 -103 321 134 -24 126 -109 59 102 51 54 212 -171 62 -190 -197 -463 48 396 -54 -145 -167 -144 -336 -184 261 162 161 452 266 61 -87 -35 -205 -215 122 -370 -286 -97 -65 169 -285 18 -464 -341 162 318 -34 177 31 95 -100 197 77 -243 255 129 31 -47 -195 -217 -295 -450 -546 -134 208 141 -140 -352 -488 -198 -192 -98 -270 -396 -6 374 -172 187 265 -127 -196 -95 137 -131 -20 -184 30 -300 -197 -522 -303 -750 -179 -139 239 416 174 -44 -29 237 196 517 383 386 2 215 260 365 35 263 259 -27 455 -149 173 503 -57 -64 -95 315 -151 -45 473 -17 -448 37 200 -165 -28 60 -47 -32 29 -120 308 -148 -202 153 518 337 -128 -73 48 162 94 185 390 -11 33 -48 -104 323 136 -24 130 -114 62 107 53 57 222 -179 65 -198 -203 -472 48 397 -54 -148 -172 -150 -351 -191 269 167 165 463 274 63 -90 -36 -213 -222 125 -375 -287 -96 -64 165 -280 18 -469 -347 165 324 -34 180 32 97 -102 199 78 -242 252 126 31 -46 -191 -213 -291 -444 -537 -131 201 136 -135 -340 -474 -193 -187 -96 -266 -391 -6 368 -171 186 264 -128 -196 -94 134 -127 -20 -175 28 -285 -189 -508 -298 -745 -178 -138 234 407 172 -43 -29 237 198 519 386 389 2 215 258 360 35 258 254 -26 445 -147 169 490 -55 -62 -91 300 -144 -43 455 -16 -440 37 197 -164 -28 60 -47 -32 29 -117 297 -142 -195 SQ 20260118T122643.0Z 9514.518553 212 1 49.22 2 67.08 193.51 72.66 195.55 0.00 1 0.00 1 0 15 2.003e-03 2.001e-03 1.426e-04 1.424e-04 2.173429e+03 8.639290e+00 1.620693e+02 -6.000000e+00 1.134914e+02 270.60 -2.00 20.00 -2.00 505.27 0.00e+00 6.770364e-04 3.922960e-06 4.068199e-05 -6.000000e+00 5.617800e-05 270.60 -2.00 20.00 -2.00 500.52 0.00e+00 1.004246e-01 2.901415e-03 1.888708e-02 -6.000000e+00 4.106425e-02 223.30 -2.00 3.61 -2.00 502.10 0.00e+00 2.548 0.000 489.00 513.00 1 4.4310e+00 2.2271e-04 4.0220e-03 -6.0000e+00 3.1523e-03 9.1658e-03 5.6089e-05 4.8035e-04 -6.0000e+00 7.9822e-04 1.6048e-02 8.8573e-04 1.7679e-05 2.6633e-05 -6.0000e+00 2.5660e-04 4.3717e-03 -5.9701e-05 10 0 0 10 0 0 99.53 17.81 0.58 0.00437 0.01052 445 98 1 2 0 110.600 15.00 17.81 18.89 21.27 20.96 22.0 971.09 363 309 309 62 -60 130 194 154 76 72 245 90 -49 127 279 88 -27 26 -166 -296 11 156 119 247 20 -156 -36 -154 -291 137 535 115 -52 -8 -412 -556 -176 54 52 148 188 121 27 -1 -46 -161 -149 -67 -128 -238 -56 92 66 11 -169 -379 -369 -235 -55 123 227 122 -11 -22 -13 -15 56 76 -60 -105 61 -86 -315 -251 -296 -362 -158 75 -52 -113 -41 -178 -282 -44 -6 -217 -169 19 200 86 46 183 -14 -276 -152 42 -51 -129 3 88 -2 -293 -352 -495 -712 -412 -14 138 300 271 32 -54 78 131 176 276 263 123 108 365 326 241 374 228 -60 87 122 8 169 79 -137 133 303 78 55 187 -119 -283 -79 35 43 93 98 -28 -84 -126 -71 42 220 15 358 302 311 63 -62 134 202 161 80 74 249 92 -50 128 280 89 -28 27 -174 -306 11 161 123 256 21 -161 -38 -159 -294 138 538 117 -53 -9 -425 -577 -181 56 54 152 194 126 28 -1 -48 -167 -153 -70 -129 -235 -56 90 64 11 -167 -383 -379 -237 -55 124 229 124 -11 -22 -13 -15 55 75 -60 -104 60 -85 -308 -246 -291 -353 -155 73 -50 -110 -40 -175 -279 -43 -6 -215 -167 19 199 86 47 182 -14 -276 -149 42 -49 -125 3 84 -2 -279 -345 -485 -706 -408 -14 138 298 265 31 -55 79 131 176 278 265 123 107 366 323 237 366 224 -59 86 120 7 165 77 -132 129 291 75 53 183 -116 -281 -77 34 43 93 98 -28 -83 -124 -70 41 211 14