File name: Pandora85s1_NewOrleansLA-XULA_20250829_L2Fit_fwvt1c5d20250716p1-8.txt File generation date: 20260326T091033.4Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c5p1-8 Local principal investigator: Morewell Gasseller Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 85 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora85_OF_v3d20231120.txt Instrument calibration file used: Pandora85s1_CF_v5d20250716.txt Level 1 file used: Pandora85s1_NewOrleansLA-XULA_20250829_L1_smca1c5d20250716p1-8.txt Full location name: Xavier University of Louisiana Short location name: NewOrleansLA-XULA Country of location: United States Location latitude [deg]: 29.9643 Location longitude [deg]: -90.1074 Location altitude [m]: 10 Local noon date: 20250829 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 1620 1770 Nominal wavelengths inside fitting window [nm]: 492.0796 492.2003 492.3210 492.4417 492.5624 492.6831 492.8037 492.9243 493.0450 493.1656 493.2861 493.4067 493.5273 493.6478 493.7683 493.8888 494.0093 494.1297 494.2502 494.3706 494.4910 494.6114 494.7318 494.8522 494.9725 495.0928 495.2132 495.3335 495.4537 495.5740 495.6942 495.8145 495.9347 496.0549 496.1750 496.2952 496.4153 496.5355 496.6556 496.7757 496.8957 497.0158 497.1358 497.2559 497.3759 497.4959 497.6158 497.7358 497.8557 497.9756 498.0955 498.2154 498.3353 498.4552 498.5750 498.6948 498.8146 498.9344 499.0542 499.1739 499.2937 499.4134 499.5331 499.6527 499.7724 499.8921 500.0117 500.1313 500.2509 500.3705 500.4900 500.6096 500.7291 500.8486 500.9681 501.0876 501.2071 501.3265 501.4459 501.5653 501.6847 501.8041 501.9235 502.0428 502.1621 502.2814 502.4007 502.5200 502.6392 502.7585 502.8777 502.9969 503.1161 503.2353 503.3544 503.4735 503.5927 503.7118 503.8308 503.9499 504.0689 504.1880 504.3070 504.4260 504.5450 504.6639 504.7829 504.9018 505.0207 505.1396 505.2585 505.3773 505.4962 505.6150 505.7338 505.8526 505.9714 506.0901 506.2088 506.3276 506.4463 506.5650 506.6836 506.8023 506.9209 507.0395 507.1581 507.2767 507.3953 507.5138 507.6323 507.7508 507.8693 507.9878 508.1063 508.2247 508.3431 508.4616 508.5799 508.6983 508.8167 508.9350 509.0533 509.1716 509.2899 509.4082 509.5264 509.6447 509.7629 509.8811 509.9993 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Temperature at electronics board [°C], 999=no temperature signal Column 96: Spectrometer control temperature [°C], 999=no temperature signal Column 97: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 98: Temperature in head sensor [°C], 999=no temperature signal Column 99: Humidity in head sensor [%], -9=no humidity signal Column 100: Pressure in head sensor [hPa], -9=no pressure signal Columns 101-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-402: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20250829T121856.1Z 9372.513149 53 1 28.40 2 81.66 84.20 152.81 78.61 0.00 1 0.00 1 0 22 4.328e-03 4.286e-03 1.247e-04 1.244e-04 1.562054e+04 9.254560e+00 1.000563e+03 -6.000000e+00 2.506014e+02 294.17 -2.00 20.00 -2.00 505.32 0.00e+00 1.474839e-03 3.543372e-06 9.991475e-05 -6.000000e+00 1.248404e-04 294.17 -2.00 20.00 -2.00 500.55 0.00e+00 8.175037e-01 2.451832e-03 8.592396e-02 -6.000000e+00 8.555130e-02 229.12 -2.00 3.24 -2.00 502.13 0.00e+00 6.466 0.003 489.00 513.00 1 1.9705e+00 1.8853e-04 1.2047e-02 -6.0000e+00 6.5809e-03 -2.8488e-02 4.7761e-05 2.1743e-03 -6.0000e+00 1.7129e-03 9.7605e-02 1.4215e-03 1.1302e-05 9.3029e-05 -6.0000e+00 4.4016e-04 1.3351e-02 6.5893e-05 11 9 0 11 4 0 54.64 33.15 2.05 0.01335 0.02321 554 62 1 4 0 51.260 41.00 20.00 33.15 32.38 4.0 1031.18 -945 -629 -311 135 665 780 734 625 567 455 100 -257 -360 -495 -581 -374 -85 -67 -64 204 246 138 330 331 382 584 367 -260 -357 -443 -715 -504 83 8 73 420 246 -104 -228 -178 -188 70 285 475 505 564 519 291 -97 -459 -729 -962 -833 -538 -322 -107 201 268 345 396 415 390 435 431 233 181 22 -290 -605 -511 -473 -428 -130 -67 -271 -218 -171 -480 -640 -560 -508 -476 -229 -85 -207 -178 -161 -146 -128 75 354 516 389 542 682 410 174 -336 -882 -1026 -836 -508 -224 -202 -128 9 -238 -273 -210 -344 -379 -20 278 389 730 998 879 532 451 264 44 76 233 72 148 374 298 304 466 8 -180 -10 -309 -586 -244 -257 -254 172 432 263 258 342 350 411 322 61 -304 -493 -673 -722 900000 -898 -610 -305 136 670 802 751 643 580 461 103 -260 -360 -491 -577 -374 -86 -68 -66 209 254 143 341 343 398 607 381 -267 -363 -439 -707 -502 84 8 76 433 257 -107 -234 -182 -194 72 292 492 527 588 538 298 -99 -461 -729 -946 -815 -533 -321 -110 205 275 354 406 426 403 450 445 239 183 22 -292 -603 -503 -464 -423 -129 -67 -268 -218 -168 -466 -615 -546 -486 -460 -222 -83 -206 -175 -158 -142 -126 74 346 508 385 528 660 393 161 -311 -801 -926 -759 -474 -213 -197 -127 9 -234 -271 -207 -336 -376 -20 278 390 733 1007 883 542 458 265 44 75 228 70 146 370 295 301 461 8 -177 -10 -296 -563 -235 -251 -250 171 436 264 263 351 361 424 332 62 -308 -491 -677 -726 900000 SQ 20250829T121924.6Z 9372.513479 53 2 28.40 2 81.55 84.26 152.72 78.71 0.00 1 0.00 1 0 22 4.281e-03 4.237e-03 1.293e-04 1.291e-04 1.551018e+04 9.589768e+00 9.930335e+02 -6.000000e+00 2.478534e+02 294.17 -2.00 20.00 -2.00 505.32 0.00e+00 1.462901e-03 3.672973e-06 9.931885e-05 -6.000000e+00 1.234725e-04 294.17 -2.00 20.00 -2.00 500.54 0.00e+00 8.107782e-01 2.540760e-03 8.471678e-02 -6.000000e+00 8.461607e-02 229.12 -2.00 3.24 -2.00 502.11 0.00e+00 6.398 0.003 489.00 513.00 1 2.0467e+00 1.9534e-04 1.1911e-02 -6.0000e+00 6.5090e-03 -2.8187e-02 4.9601e-05 2.1433e-03 -6.0000e+00 1.6943e-03 9.1411e-02 1.4856e-03 1.1750e-05 9.2566e-05 -6.0000e+00 4.3534e-04 1.4711e-02 5.4957e-05 11 9 0 11 4 0 21.81 33.15 2.05 0.01471 0.02502 554 62 1 4 0 51.260 41.00 20.00 33.15 32.45 4.0 1031.47 -936 -623 -292 146 673 786 714 645 555 444 82 -257 -378 -479 -597 -349 -74 -72 -82 202 244 152 314 314 369 578 370 -272 -344 -444 -722 -484 99 17 50 405 251 -95 -226 -199 -173 63 304 455 492 554 540 327 -102 -443 -716 -963 -815 -523 -322 -132 188 264 314 383 385 375 397 426 237 192 6 -272 -570 -482 -481 -397 -122 -108 -245 -229 -166 -454 -632 -586 -500 -476 -254 -65 -179 -203 -161 -149 -122 98 353 495 404 536 696 423 131 -370 -854 -1030 -816 -478 -220 -227 -134 -13 -229 -260 -208 -356 -353 -22 252 411 695 985 851 572 462 268 50 71 246 80 145 359 274 303 459 8 -181 -20 -286 -553 -251 -257 -240 165 430 244 289 355 356 412 323 57 -289 -491 -680 -720 900000 -887 -603 -285 147 675 805 742 661 565 457 83 -259 -376 -473 -589 -348 -75 -73 -85 211 256 160 323 325 382 599 382 -284 -348 -448 -726 -490 100 17 52 424 261 -98 -231 -203 -177 64 316 478 510 574 556 339 -104 -442 -712 -941 -793 -515 -326 -134 195 269 320 390 393 385 409 437 241 196 6 -272 -565 -471 -469 -390 -121 -108 -246 -229 -162 -447 -616 -568 -487 -467 -245 -63 -177 -202 -160 -147 -120 97 350 494 397 530 669 402 123 -340 -772 -925 -738 -443 -209 -220 -132 -13 -228 -257 -204 -352 -354 -22 250 409 693 988 865 578 466 273 50 69 243 79 142 352 270 298 451 8 -176 -19 -278 -538 -239 -250 -233 163 430 249 292 361 364 422 330 58 -290 -494 -679 -719 900000 SQ 20250829T122757.1Z 9372.519411 55 1 54.36 2 79.71 85.30 150.99 80.39 0.00 1 0.00 1 0 22 4.298e-03 4.257e-03 4.500e-04 4.490e-04 1.362043e+04 3.308859e+01 8.750416e+02 -6.000000e+00 2.488396e+02 294.17 -2.00 20.00 -2.00 505.32 0.00e+00 1.237902e-03 1.277034e-05 8.509681e-05 -6.000000e+00 1.239602e-04 294.17 -2.00 20.00 -2.00 500.50 0.00e+00 6.604240e-01 8.874851e-03 7.630780e-02 -6.000000e+00 8.494297e-02 229.12 -2.00 3.24 -2.00 502.09 0.00e+00 5.365 0.002 489.00 513.00 1 5.1969e+00 6.8238e-04 1.0255e-02 -6.0000e+00 6.5343e-03 -2.6218e-02 1.7314e-04 1.9097e-03 -6.0000e+00 1.7006e-03 4.6178e-03 1.2030e-03 4.1547e-05 7.8823e-05 -6.0000e+00 4.3705e-04 1.4047e-02 6.7984e-05 11 9 0 11 4 0 98.57 33.18 2.06 0.01405 0.02239 66 7 1 4 0 823.540 41.00 20.00 33.18 32.91 4.0 1032.89 -1043 -624 -333 116 663 749 669 670 578 425 160 -270 -309 -480 -561 -319 14 -94 -218 208 215 159 263 397 359 498 347 -234 -272 -403 -770 -420 14 38 55 481 249 -79 -297 -214 -114 148 256 472 547 459 510 294 -83 -394 -738 -927 -696 -467 -400 -117 222 221 272 436 357 268 463 344 273 123 50 -341 -610 -592 -444 -423 -35 -86 -290 -14 -276 -501 -573 -596 -607 -438 -300 -47 -202 -58 -23 -137 -88 89 409 370 431 407 703 372 119 -391 -806 -1010 -880 -420 -203 -168 -250 -39 -216 -259 -271 -480 -396 -17 269 414 775 1041 907 562 478 257 84 15 205 82 234 430 319 231 420 -37 -160 -38 -244 -631 -211 -305 -263 126 358 338 211 311 373 396 317 109 -328 -471 -753 -724 900000 -1005 -613 -326 117 682 761 690 695 596 433 162 -270 -315 -485 -567 -325 14 -96 -229 219 228 169 270 409 372 516 357 -246 -278 -402 -765 -419 15 39 58 502 258 -82 -303 -217 -116 151 266 494 577 484 534 304 -84 -391 -738 -912 -680 -462 -394 -118 228 229 282 450 370 280 483 359 282 125 50 -339 -601 -576 -430 -412 -35 -86 -290 -14 -269 -480 -562 -581 -576 -419 -289 -45 -199 -57 -23 -135 -86 88 404 369 432 404 678 349 111 -359 -726 -903 -792 -387 -188 -163 -244 -39 -212 -253 -263 -469 -392 -17 270 416 778 1051 927 564 479 262 84 15 200 80 230 423 315 229 414 -37 -157 -36 -233 -602 -202 -296 -254 123 355 340 215 319 384 409 327 112 -331 -468 -741 -713 900000 SQ 20250829T123207.6Z 9372.522311 58 1 10.27 2 78.81 85.81 150.14 81.16 0.00 1 0.00 1 0 22 4.111e-03 4.083e-03 4.007e-04 4.002e-04 1.211862e+04 2.873601e+01 7.842167e+02 -6.000000e+00 2.380508e+02 294.17 -2.00 20.00 -2.00 505.30 0.00e+00 1.138378e-03 1.137663e-05 7.878215e-05 -6.000000e+00 1.185896e-04 294.17 -2.00 20.00 -2.00 500.51 0.00e+00 6.250733e-01 7.880218e-03 6.892192e-02 -6.000000e+00 8.127038e-02 229.12 -2.00 3.24 -2.00 502.09 0.00e+00 4.970 0.001 489.00 513.00 1 3.5688e+00 6.0605e-04 9.4084e-03 -6.0000e+00 6.2516e-03 -2.1979e-02 1.5450e-04 1.7175e-03 -6.0000e+00 1.6273e-03 2.5050e-02 1.3027e-03 3.7337e-05 7.4008e-05 -6.0000e+00 4.1812e-04 1.4973e-02 5.2630e-05 12 9 1 12 5 1 86.37 33.20 2.02 0.01497 0.02401 43 26 1 4 0 233.260 41.00 20.00 33.20 33.06 4.0 1033.45 -971 -614 -357 73 641 764 660 606 548 420 61 -293 -359 -462 -557 -322 -36 -88 -141 279 256 115 323 260 324 482 357 -256 -332 -401 -647 -435 103 -6 80 478 227 -42 -143 -108 -125 152 225 466 506 467 492 297 -45 -387 -623 -981 -794 -527 -363 -95 177 264 299 336 398 348 390 423 200 159 8 -328 -536 -468 -410 -353 -139 -46 -171 -151 -96 -420 -603 -593 -532 -511 -242 -43 -214 -96 -117 -195 -95 17 300 392 331 449 661 362 125 -343 -786 -943 -753 -386 -198 -146 -183 -76 -216 -306 -225 -319 -344 29 367 421 676 993 867 504 463 304 -23 161 261 38 165 294 264 234 562 85 -147 122 -298 -589 -196 -265 -312 59 323 273 281 349 387 320 296 26 -386 -492 -643 -712 900000 -937 -595 -353 73 648 788 683 631 567 430 63 -298 -359 -464 -560 -322 -36 -90 -146 291 265 119 335 271 339 502 370 -263 -339 -399 -650 -435 104 -7 83 496 234 -43 -146 -110 -128 156 232 484 529 483 511 305 -46 -391 -621 -961 -773 -520 -363 -96 180 271 307 344 408 355 399 430 204 160 8 -327 -535 -461 -403 -349 -137 -46 -171 -149 -94 -409 -589 -576 -512 -496 -236 -43 -211 -95 -116 -193 -94 16 294 388 330 443 644 347 118 -320 -730 -868 -697 -361 -188 -142 -181 -75 -214 -301 -222 -314 -343 29 366 421 677 999 873 513 470 305 -23 158 256 37 162 288 260 231 550 83 -144 118 -286 -565 -188 -256 -304 58 320 275 282 353 394 327 301 26 -385 -488 -637 -705 900000 SQ 20250829T123732.0Z 9372.526064 61 1 54.12 2 77.64 86.47 149.03 82.12 0.00 1 0.00 1 0 22 4.139e-03 4.103e-03 4.991e-04 4.980e-04 1.193334e+04 3.600642e+01 7.692426e+02 -6.000000e+00 2.396287e+02 294.17 -2.00 20.00 -2.00 505.29 0.00e+00 1.114476e-03 1.410239e-05 7.712292e-05 -6.000000e+00 1.193718e-04 294.17 -2.00 20.00 -2.00 500.46 0.00e+00 5.458250e-01 9.814050e-03 6.831437e-02 -6.000000e+00 8.179893e-02 229.12 -2.00 3.24 -2.00 502.05 0.00e+00 4.536 0.001 489.00 513.00 1 5.4811e+00 7.5457e-04 8.9019e-03 -6.0000e+00 6.2924e-03 -2.2731e-02 1.9250e-04 1.6893e-03 -6.0000e+00 1.6376e-03 3.9633e-03 1.1629e-03 4.6509e-05 7.0921e-05 -6.0000e+00 4.2088e-04 1.4408e-02 6.5670e-05 11 9 0 11 4 0 99.83 33.23 2.03 0.01441 0.02247 86 10 1 4 0 629.220 41.00 20.00 33.23 33.15 4.0 1033.71 -995 -679 -295 122 617 770 568 522 511 374 129 -248 -373 -532 -500 -256 -50 -131 -56 242 227 111 317 362 378 497 429 -388 -344 -392 -664 -430 66 27 52 497 203 -120 -224 -47 -140 174 265 487 458 505 494 326 -48 -469 -707 -856 -765 -591 -307 -237 160 172 305 440 394 410 375 413 257 239 -25 -162 -495 -482 -452 -362 -84 -103 -251 -142 -220 -400 -617 -451 -542 -475 -195 -15 -237 6 -122 -136 -165 -1 306 371 392 493 714 400 99 -399 -880 -904 -771 -394 -215 -152 -159 65 -289 -156 -386 -409 -293 -80 261 425 800 1001 923 494 495 282 43 148 215 20 190 277 229 204 432 8 -88 19 -247 -583 -182 -339 -405 82 432 227 255 268 363 444 202 2 -374 -444 -611 -605 900000 -963 -670 -290 124 637 782 587 542 528 382 130 -257 -380 -538 -505 -260 -50 -134 -59 255 240 117 335 384 403 529 454 -407 -351 -389 -656 -428 67 28 54 515 210 -126 -235 -49 -146 183 272 505 479 528 513 334 -49 -478 -701 -835 -742 -580 -310 -238 163 176 312 449 404 422 388 426 262 240 -25 -159 -498 -479 -448 -361 -84 -101 -248 -139 -219 -392 -600 -436 -527 -465 -192 -14 -231 6 -120 -133 -161 -1 300 368 391 486 686 387 94 -367 -796 -809 -693 -362 -206 -147 -158 65 -290 -154 -382 -408 -295 -79 258 421 794 999 931 505 503 283 43 144 207 20 184 269 223 199 419 8 -85 18 -232 -547 -171 -324 -396 82 433 232 254 269 366 449 204 2 -370 -446 -605 -599 900000 SQ 20250829T124214.2Z 9372.529332 64 1 53.90 2 76.63 87.05 148.07 82.91 0.00 1 0.00 1 0 22 4.037e-03 4.001e-03 8.550e-04 8.524e-04 1.085626e+04 6.109117e+01 7.052655e+02 -6.000000e+00 2.337337e+02 294.17 -2.00 20.00 -2.00 505.28 0.00e+00 9.965945e-04 2.408198e-05 6.856112e-05 -6.000000e+00 1.164352e-04 294.17 -2.00 20.00 -2.00 500.40 0.00e+00 5.304386e-01 1.684129e-02 6.228437e-02 -6.000000e+00 7.978641e-02 229.12 -2.00 3.24 -2.00 502.00 0.00e+00 4.215 0.001 489.00 513.00 1 6.4697e+00 1.2944e-03 8.1881e-03 -6.0000e+00 6.1376e-03 -1.1582e-02 3.3044e-04 1.5453e-03 -6.0000e+00 1.5973e-03 1.5508e-03 1.1638e-03 8.0110e-05 6.3384e-05 -6.0000e+00 4.1052e-04 1.2519e-02 7.7446e-05 11 9 0 11 4 0 98.05 33.27 2.00 0.01252 0.02059 25 3 1 4 0 2155.790 41.00 20.00 33.27 33.18 4.0 1033.78 -763 -596 -446 32 501 525 504 357 560 295 131 -406 -390 -423 -528 -316 121 -51 -87 458 154 96 465 223 376 380 407 -201 -206 -364 -609 -338 74 158 86 406 385 -77 -339 -138 -198 69 160 546 463 432 466 236 -45 -407 -656 -930 -739 -666 -121 -265 83 5 431 423 339 234 382 346 224 270 207 -424 -327 -257 -382 -174 -202 -296 -431 -247 -47 -370 -376 -589 -459 -429 -329 187 -98 -66 -110 -106 -212 -35 249 444 464 549 575 361 97 -505 -747 -824 -818 -183 -205 -301 -285 -94 -184 -304 -245 -466 -205 -139 227 428 839 906 768 486 431 248 70 351 180 -162 295 184 459 339 567 -114 -311 125 -113 -505 -195 -123 -263 180 280 237 469 334 333 589 13 -65 -407 -517 -732 -941 900000 -731 -583 -451 33 511 547 532 380 591 307 135 -415 -392 -421 -526 -317 124 -54 -93 491 166 104 500 242 408 397 439 -214 -213 -367 -612 -341 76 168 90 425 399 -79 -347 -140 -202 71 166 570 488 455 487 244 -46 -419 -658 -917 -724 -662 -123 -267 85 5 443 433 349 242 396 357 229 272 205 -418 -318 -257 -381 -167 -197 -291 -427 -242 -45 -351 -367 -573 -448 -406 -314 180 -96 -65 -108 -103 -207 -34 245 440 463 542 555 339 92 -470 -680 -743 -742 -170 -190 -291 -284 -95 -184 -301 -241 -463 -206 -135 223 421 825 897 768 490 433 246 69 336 178 -155 283 177 441 326 543 -109 -296 117 -109 -466 -180 -115 -252 175 277 237 473 340 341 602 14 -67 -409 -509 -712 -917 900000