File name: Pandora51s1_OldFieldNY_20220128_L2Fit_ffus5c5d20211018p1-8.txt File generation date: 20251205T021642.5Z Data description: Level 2 spectral fitting results file Data file version: ffus5c5p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 51 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora51_OF_v5d20190801.txt Instrument calibration file used: Pandora51s1_CF_v5d20211018.txt Level 1 file used: Pandora51s1_OldFieldNY_20220128_L1_smca1c5d20211018p1-8.txt Full location name: Flax Pond NYSDEC (USEPA AQS ID 36-103-0044) Short location name: OldFieldNY Country of location: USA Location latitude [deg]: 40.9635 Location longitude [deg]: -73.1402 Location altitude [m]: 3 Local noon date: 20220128 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: Modification of session 3 - Full Lab Cal on 1.8 for HCHO First and last pixel inside fitting window: 382 647 Nominal wavelengths inside fitting window [nm]: 322.6315 322.7708 322.9100 323.0492 323.1885 323.3277 323.4669 323.6061 323.7452 323.8844 324.0235 324.1627 324.3018 324.4409 324.5800 324.7191 324.8582 324.9973 325.1363 325.2754 325.4144 325.5534 325.6924 325.8314 325.9704 326.1094 326.2484 326.3873 326.5263 326.6652 326.8041 326.9430 327.0819 327.2208 327.3596 327.4985 327.6374 327.7762 327.9150 328.0538 328.1926 328.3314 328.4702 328.6089 328.7477 328.8864 329.0252 329.1639 329.3026 329.4413 329.5799 329.7186 329.8573 329.9959 330.1345 330.2732 330.4118 330.5504 330.6890 330.8275 330.9661 331.1046 331.2432 331.3817 331.5202 331.6587 331.7972 331.9357 332.0741 332.2126 332.3510 332.4895 332.6279 332.7663 332.9047 333.0431 333.1814 333.3198 333.4581 333.5965 333.7348 333.8731 334.0114 334.1497 334.2879 334.4262 334.5644 334.7027 334.8409 334.9791 335.1173 335.2555 335.3937 335.5318 335.6700 335.8081 335.9463 336.0844 336.2225 336.3606 336.4986 336.6367 336.7748 336.9128 337.0508 337.1888 337.3269 337.4648 337.6028 337.7408 337.8788 338.0167 338.1546 338.2926 338.4305 338.5684 338.7062 338.8441 338.9820 339.1198 339.2577 339.3955 339.5333 339.6711 339.8089 339.9466 340.0844 340.2222 340.3599 340.4976 340.6353 340.7730 340.9107 341.0484 341.1861 341.3237 341.4614 341.5990 341.7366 341.8742 342.0118 342.1494 342.2869 342.4245 342.5620 342.6996 342.8371 342.9746 343.1121 343.2496 343.3870 343.5245 343.6619 343.7993 343.9368 344.0742 344.2116 344.3489 344.4863 344.6237 344.7610 344.8984 345.0357 345.1730 345.3103 345.4476 345.5848 345.7221 345.8593 345.9966 346.1338 346.2710 346.4082 346.5454 346.6826 346.8197 346.9569 347.0940 347.2311 347.3682 347.5053 347.6424 347.7795 347.9165 348.0536 348.1906 348.3277 348.4647 348.6017 348.7387 348.8756 349.0126 349.1495 349.2865 349.4234 349.5603 349.6972 349.8341 349.9710 350.1078 350.2447 350.3815 350.5184 350.6552 350.7920 350.9288 351.0655 351.2023 351.3390 351.4758 351.6125 351.7492 351.8859 352.0226 352.1593 352.2960 352.4326 352.5692 352.7059 352.8425 352.9791 353.1157 353.2522 353.3888 353.5254 353.6619 353.7984 353.9349 354.0714 354.2079 354.3444 354.4809 354.6173 354.7538 354.8902 355.0266 355.1630 355.2994 355.4358 355.5721 355.7085 355.8448 355.9811 356.1175 356.2538 356.3900 356.5263 356.6626 356.7988 356.9351 357.0713 357.2075 357.3437 357.4799 357.6161 357.7522 357.8884 358.0245 358.1606 358.2967 358.4328 358.5689 358.7050 358.8411 358.9771 359.1131 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220128T140856.3Z 8063.589541 192 1 30.20 2 71.86 135.84 67.12 189.61 0.00 1 0.00 1 0 33 1.157e-03 8.981e-04 8.698e-04 7.298e-04 1.163817e-06 2.550431e-07 7.723499e-08 6.014477e-07 3.747856e-07 224.23 -2.00 3.51 -2.00 342.07 0.00e+00 3.207989e-04 7.145904e-05 1.997177e-05 3.016766e-05 1.041329e-04 275.24 -2.00 20.00 -2.00 339.73 0.00e+00 1.848239e-05 9.733676e-06 3.038770e-06 4.004843e-05 1.722553e-05 275.24 -2.00 20.00 -2.00 347.80 0.00e+00 1.100768e-03 2.870406e-05 5.559197e-05 2.072116e-05 4.987211e-05 275.24 -2.00 20.00 -2.00 346.64 0.00e+00 5.895711e+05 6.442246e+04 4.684844e+04 3.113006e+05 9.777162e+04 257.40 -2.00 11.22 -2.00 352.61 0.00e+00 4.591775e-01 1.193543e-03 3.704191e-03 2.885221e-03 1.390705e-03 224.23 -2.00 3.51 -2.00 331.81 0.00e+00 -2.313839e-03 1.681446e-03 6.282488e-04 1.479896e-04 1.485466e-03 275.24 -2.00 20.00 -2.00 330.11 0.00e+00 3.170 0.001 319.50 362.20 4 3.8613e+00 9.7095e-04 2.2450e-02 2.3079e-03 1.5514e-03 -2.8396e-02 2.8942e-04 3.5263e-03 4.0712e-04 3.9688e-04 -1.2059e-03 5.0637e-04 8.2149e-04 1.6289e-04 7.5733e-04 2.3866e-04 2.9954e-04 6.3313e-04 5.2635e-05 3.1811e-04 -5.6440e-04 4.3386e-04 4.5000e-04 1.1523e-04 5.7521e-04 2.4906e-03 3.0581e-03 5.7364e-04 2.8846e-04 9.8738e-05 7.4562e-04 -6.5866e-05 1.0410e-05 3.8600e-06 9.0922e-07 1.7777e-05 -4.0800e-03 -3.0073e-05 -5.6796e-01 6.1447e-02 2.4338e-02 6.0773e-03 9.0894e-02 12 9 9 12 1 1 99.62 22.32 0.17 -0.00408 -0.00489 30 11 1 5 0 968.450 26.94 19.99 22.32 6.59 10.8 880.12 -63 -540 -572 -195 -492 -188 63 -102 -192 -71 368 -4 387 248 157 132 59 111 0 9 -107 284 26 13 97 -151 69 -84 -44 -132 -41 -84 395 -63 99 140 -26 -30 129 -105 63 49 97 -24 -50 -140 60 -225 55 155 129 -79 53 26 -77 -40 115 -5 80 -98 -76 -96 186 -263 174 -63 -52 -81 -58 -28 -88 37 -85 132 3 30 -20 15 -46 -64 74 -125 -124 -173 -91 -19 -14 -82 -21 19 -81 -11 -60 -20 -71 -64 179 150 170 21 131 -9 -33 67 -33 -16 129 11 115 -15 132 72 117 163 68 21 14 -84 39 22 -124 100 10 29 31 -55 10 -10 -5 -128 -56 -106 92 -75 -55 60 -27 24 -6 147 89 -18 9 55 -90 -104 15 -85 -4 -123 -44 -115 -31 97 136 -24 37 98 94 -63 -78 83 88 -146 -167 35 -205 155 -82 36 -6 51 -46 25 -41 10 -23 69 42 -101 22 77 -99 82 2 20 83 -54 16 -31 95 -23 -6 21 -17 133 -7 65 -16 57 5 29 -117 -9 -169 68 -45 215 198 23 -74 59 151 -5 -105 -28 -69 70 -101 -11 61 16 -66 -104 -32 -12 58 0 59 -56 -33 92 -16 -18 -58 -37 39 2 35 -65 -62 -15 11 -43 93 16 24 -7 -14 48 -69 -64 -27 -138 30 -45 174 -25 -109 -138 71 57 -55 30 3 162 -21 -180 -199 -73 -197 -80 27 -46 -90 -35 185 -2 202 129 78 64 28 53 0 5 -59 167 16 8 65 -103 48 -58 -30 -93 -29 -59 274 -43 68 95 -17 -20 83 -68 40 32 65 -16 -35 -102 47 -183 46 131 111 -69 46 22 -66 -32 88 -4 59 -75 -60 -75 143 -204 139 -51 -44 -69 -48 -24 -74 32 -74 114 2 26 -17 13 -38 -51 58 -102 -104 -149 -81 -18 -13 -75 -19 17 -75 -10 -59 -19 -68 -56 143 114 135 18 119 -8 -28 54 -26 -13 109 10 108 -14 122 66 106 154 66 21 14 -85 39 21 -118 96 10 31 33 -61 11 -11 -6 -134 -58 -109 94 -77 -56 61 -27 25 -6 160 100 -20 10 59 -97 -115 17 -97 -4 -139 -49 -126 -34 100 129 -21 31 87 88 -63 -82 93 98 -167 -193 40 -233 171 -89 37 -6 56 -52 28 -48 11 -27 81 47 -110 23 81 -107 92 3 23 95 -62 19 -36 108 -25 -7 23 -19 147 -7 77 -19 74 7 38 -151 -12 -215 85 -56 252 233 27 -91 75 195 -6 -126 -32 -76 77 -115 -13 77 20 -85 -135 -41 -16 78 0 79 -75 -44 125 -22 -24 -80 -49 51 2 45 -84 -79 -20 15 -58 123 20 29 -8 -15 52 -76 -72 -31 -168 37 -53 195 -27 -109 -134 68 56 -56 32 3 203 SS 20220128T141428.8Z 8063.593388 195 1 48.70 2 71.14 137.00 67.31 190.92 0.00 1 0.00 1 0 33 1.034e-03 7.506e-04 6.650e-04 5.456e-04 7.813798e-07 1.916252e-07 7.626170e-08 6.014466e-07 3.351553e-07 224.23 -2.00 3.51 -2.00 342.28 0.00e+00 3.795625e-04 5.349739e-05 2.084768e-05 3.015671e-05 9.320014e-05 275.24 -2.00 20.00 -2.00 339.98 0.00e+00 1.781723e-05 7.289030e-06 2.712878e-06 4.004865e-05 1.540936e-05 275.24 -2.00 20.00 -2.00 347.95 0.00e+00 1.006922e-03 2.142701e-05 5.243524e-05 2.071271e-05 4.458654e-05 275.24 -2.00 20.00 -2.00 346.79 0.00e+00 6.368141e+05 4.841568e+04 4.497396e+04 3.113002e+05 8.722744e+04 257.40 -2.00 11.22 -2.00 352.60 0.00e+00 4.407958e-01 9.064651e-04 3.544015e-03 2.884793e-03 1.230827e-03 224.23 -2.00 3.51 -2.00 332.01 0.00e+00 -3.620515e-03 1.295888e-03 1.075371e-03 1.568608e-04 1.324886e-03 275.24 -2.00 20.00 -2.00 330.36 0.00e+00 3.056 0.000 319.50 362.20 4 3.7150e+00 7.2911e-04 2.1637e-02 2.3079e-03 1.3958e-03 -2.7425e-02 2.1936e-04 3.4000e-03 4.0697e-04 3.5452e-04 3.0799e-05 3.8063e-04 7.8483e-04 1.6426e-04 6.7636e-04 5.4305e-04 2.2967e-04 6.1356e-04 5.2568e-05 2.8448e-04 -1.1511e-03 3.2810e-04 4.3493e-04 1.1640e-04 5.1392e-04 3.1167e-03 5.4885e-03 4.4232e-04 2.6504e-04 9.6482e-05 6.8149e-04 -8.3361e-05 7.8010e-06 3.5980e-06 9.1388e-07 1.5891e-05 -3.7680e-03 -3.4423e-05 -7.1486e-01 4.6686e-02 2.1643e-02 5.9767e-03 8.2381e-02 12 9 8 11 8 0 99.74 22.29 0.28 -0.00377 -0.00480 85 19 1 5 0 572.680 26.83 20.00 22.29 6.73 10.8 880.93 -450 -211 -625 -172 -362 -101 -355 -190 205 11 232 66 472 142 58 74 -6 210 -88 193 -45 104 -28 -5 213 48 78 -114 -139 -80 -71 14 116 133 42 87 1 73 -93 -29 6 -69 212 -21 14 -158 -65 43 64 -129 62 96 -145 -42 -13 85 34 -112 54 -117 27 -18 170 27 -15 -36 -159 -29 -46 58 6 26 115 51 39 -146 127 10 52 6 -124 -36 -26 -132 -202 -51 -65 -41 -6 -41 -11 -122 -49 9 61 17 95 15 -88 48 22 152 -77 22 57 67 125 24 122 5 84 -39 74 63 92 35 -44 1 -21 64 10 46 20 58 77 -27 -42 -15 -46 -67 -116 -26 -110 14 1 51 18 49 12 -53 114 -59 39 -91 -25 -46 -127 42 -59 -20 -112 -46 -67 -38 126 -26 74 59 70 -40 65 82 87 80 -67 -68 -114 50 -87 -16 -98 -52 64 -32 43 -62 71 -10 68 77 10 51 2 33 86 109 110 -148 18 -89 78 -16 -42 -37 41 38 3 36 -8 1 -42 -9 -40 3 28 -10 75 64 61 -3 -7 -9 21 -27 -44 50 34 -79 -66 -21 62 -65 -51 -34 67 -73 -26 15 2 12 -19 -16 27 95 -9 62 -50 9 31 -80 -23 8 31 -31 98 107 -126 22 26 38 17 -90 -97 -122 -63 -168 6 -121 3 105 9 61 55 97 38 101 -146 -67 -207 -59 -136 -40 -148 -82 93 5 111 32 233 70 27 34 -3 95 -42 94 -24 58 -17 -4 142 31 53 -77 -92 -54 -49 10 80 90 29 59 1 46 -58 -18 4 -44 138 -14 9 -113 -51 35 53 -110 53 83 -128 -36 -11 67 26 -81 39 -87 21 -14 130 20 -12 -29 -131 -24 -38 46 5 21 98 44 32 -122 106 8 43 5 -97 -29 -21 -113 -181 -45 -59 -38 -5 -37 -10 -116 -49 9 57 14 74 11 -69 40 19 135 -63 18 43 53 103 22 115 5 76 -36 68 58 91 34 -44 1 -22 62 10 44 20 61 83 -30 -46 -17 -49 -70 -118 -26 -113 14 1 52 18 49 13 -58 127 -65 42 -96 -26 -51 -146 49 -69 -22 -126 -50 -72 -39 119 -23 62 51 64 -39 70 91 101 90 -77 -77 -128 56 -92 -17 -102 -57 73 -36 50 -75 83 -12 78 83 10 53 2 37 101 127 126 -173 21 -105 89 -17 -46 -40 45 42 3 43 -10 1 -56 -12 -52 4 36 -13 91 77 71 -4 -8 -12 28 -34 -53 57 38 -86 -77 -26 79 -85 -66 -44 89 -100 -35 21 3 16 -25 -22 38 134 -12 87 -68 11 40 -103 -30 11 42 -42 132 134 -152 25 28 41 20 -102 -114 -148 -78 -203 7 -126 3 101 8 58 55 105 45 127 SS 20220128T142027.4Z 8063.597539 198 1 26.02 2 70.38 138.27 67.54 192.31 0.00 1 0.00 1 0 33 1.871e-03 1.632e-03 1.802e-03 1.556e-03 1.462677e-06 5.379325e-07 9.595908e-08 6.014893e-07 6.063500e-07 224.23 -2.00 3.51 -2.00 341.65 0.00e+00 -8.513795e-05 1.499030e-04 2.286915e-05 3.012678e-05 1.685234e-04 275.24 -2.00 20.00 -2.00 339.25 0.00e+00 6.066657e-05 2.090503e-05 3.025959e-06 4.004659e-05 2.795423e-05 275.24 -2.00 20.00 -2.00 347.48 0.00e+00 8.020728e-04 6.133917e-05 3.898825e-05 2.072457e-05 8.057394e-05 275.24 -2.00 20.00 -2.00 346.25 0.00e+00 2.859587e+05 1.350467e+05 4.304193e+04 3.113206e+05 1.564343e+05 257.40 -2.00 11.22 -2.00 352.40 0.00e+00 4.235251e-01 2.408084e-03 3.425211e-03 2.884447e-03 2.194981e-03 224.23 -2.00 3.51 -2.00 331.53 0.00e+00 4.474338e-03 3.394236e-03 9.416361e-04 1.520704e-04 2.391774e-03 275.24 -2.00 20.00 -2.00 329.75 0.00e+00 2.945 0.000 319.50 362.20 4 5.1977e+00 2.0798e-03 2.0814e-02 2.3073e-03 2.5741e-03 7.6700e-03 5.8751e-04 3.2702e-03 4.0699e-04 6.3612e-04 -4.9953e-03 1.0601e-03 7.1640e-04 1.5880e-04 1.2218e-03 5.3860e-04 6.1365e-04 5.9229e-04 5.2506e-05 5.1260e-04 -2.8855e-04 8.9831e-04 4.0502e-04 1.1064e-04 9.2235e-04 7.6758e-04 -1.6065e-03 1.2544e-03 2.7109e-04 1.0287e-04 1.3345e-03 -7.5965e-05 2.2356e-05 3.8270e-06 9.1623e-07 2.8744e-05 -2.7579e-03 -2.7975e-05 -5.6119e-01 1.3328e-01 2.2418e-02 6.2686e-03 1.5263e-01 12 9 9 12 9 1 99.77 22.27 0.15 -0.00276 -0.00370 7 3 1 5 0 3229.580 26.83 19.99 22.27 6.88 10.8 881.89 447 -205 -73 -356 -376 -493 194 876 30 -133 -52 -265 275 -69 -180 245 50 458 281 -493 78 -380 140 670 -35 -328 -137 127 -151 -6 375 118 186 -209 -321 -18 -346 254 197 288 103 -96 -11 35 -133 -271 -51 -214 185 221 -394 155 31 -59 -311 -64 168 -70 -64 -133 36 -37 158 111 -206 -102 -47 240 44 -337 187 -111 206 181 171 -49 113 146 139 -81 -310 -29 -223 -270 282 -66 -283 208 -71 -130 159 -3 84 214 -184 -56 157 -39 -66 -3 163 -126 268 25 -6 255 23 12 -127 47 106 -71 -10 16 91 28 127 191 98 34 55 -48 -51 -49 189 47 -86 -147 -88 -220 -347 -68 148 103 44 -24 -44 11 65 -86 -66 -62 29 -56 123 -41 -86 20 -131 24 -39 189 -64 -32 358 17 -155 -43 -14 187 -98 282 -62 -120 -144 118 -281 161 -312 213 -191 5 225 -58 -56 89 15 195 -185 92 68 3 -192 -192 8 139 94 -81 -113 1 -221 96 57 -318 -61 -112 -51 101 -29 53 60 166 -122 -172 199 292 6 291 -20 -48 265 -119 61 164 -41 -156 -10 -126 369 73 -96 27 -321 -258 88 -133 95 46 -2 -21 113 -182 104 9 -59 -45 136 34 6 -90 -286 278 85 158 24 -219 231 93 -31 212 -68 -220 -111 -135 134 -104 -71 -190 -125 -85 -237 -46 113 55 256 77 165 -74 -27 -144 -162 -222 90 419 15 -69 -28 -146 153 -38 -96 127 25 225 145 -272 45 -239 93 461 -25 -238 -99 92 -111 -4 278 86 135 -149 -230 -13 -246 173 133 193 71 -66 -8 25 -97 -209 -42 -182 163 195 -354 140 28 -53 -276 -54 134 -54 -50 -106 29 -30 126 89 -171 -87 -41 210 38 -290 161 -96 182 160 150 -43 99 128 118 -66 -251 -24 -192 -241 257 -62 -269 195 -64 -120 148 -3 84 214 -179 -50 128 -30 -54 -2 148 -115 231 21 -5 207 20 11 -123 45 99 -65 -10 15 91 28 129 195 98 33 53 -46 -51 -51 208 53 -96 -163 -95 -230 -361 -69 153 107 45 -24 -44 11 69 -95 -74 -69 32 -60 132 -45 -98 23 -151 27 -43 207 -70 -33 340 15 -132 -37 -13 185 -104 311 -70 -138 -165 134 -320 179 -332 220 -202 5 247 -65 -65 104 18 229 -209 98 71 3 -208 -215 9 157 107 -92 -130 1 -250 105 60 -341 -67 -122 -58 117 -35 69 78 215 -157 -220 249 356 7 338 -23 -56 323 -149 78 203 -48 -174 -10 -136 414 87 -118 34 -406 -330 113 -173 125 61 -2 -27 148 -242 140 12 -80 -60 178 44 8 -113 -362 357 110 206 31 -272 270 103 -32 223 -73 -241 -128 -162 159 -121 -76 -190 -120 -79 -220 -43 110 57 292 94 SS 20220128T143234.6Z 8063.605956 201 1 9.42 2 68.89 140.90 68.08 195.12 0.00 1 0.00 1 0 33 2.435e-03 2.120e-03 2.157e-03 1.939e-03 2.818957e-07 6.615375e-07 1.135647e-07 6.015263e-07 7.889069e-07 224.23 -2.00 3.51 -2.00 341.16 0.00e+00 1.459884e-04 1.842016e-04 2.950850e-05 3.010723e-05 2.198777e-04 275.24 -2.00 20.00 -2.00 338.71 0.00e+00 3.483843e-05 2.612584e-05 2.286585e-06 4.004531e-05 3.639981e-05 275.24 -2.00 20.00 -2.00 347.12 0.00e+00 6.674557e-04 7.660645e-05 3.664068e-05 2.074225e-05 1.048719e-04 275.24 -2.00 20.00 -2.00 345.85 0.00e+00 8.177847e+04 1.656799e+05 4.334168e+04 3.113286e+05 2.034721e+05 257.40 -2.00 11.22 -2.00 352.33 0.00e+00 3.992297e-01 2.831814e-03 3.232848e-03 2.884573e-03 2.817278e-03 224.23 -2.00 3.51 -2.00 331.10 0.00e+00 -9.665869e-03 3.887807e-03 2.341945e-03 1.466915e-04 3.089637e-03 275.24 -2.00 20.00 -2.00 329.21 0.00e+00 2.751 0.000 319.50 362.20 4 4.8558e+00 2.6039e-03 1.9436e-02 2.3068e-03 3.3797e-03 -1.9958e-03 7.0931e-04 3.0530e-03 4.0712e-04 8.2546e-04 -4.8245e-03 1.3010e-03 6.8451e-04 1.5480e-04 1.5922e-03 -1.6491e-03 7.1975e-04 6.0381e-04 5.2486e-05 6.6870e-04 2.3749e-03 1.0862e-03 3.9632e-04 1.0713e-04 1.2065e-03 1.2391e-03 1.7547e-03 1.5582e-03 2.7230e-04 1.0705e-04 1.7702e-03 6.4838e-05 2.7829e-05 3.8938e-06 9.0440e-07 3.7429e-05 -3.1625e-03 7.0847e-05 -7.2810e-01 1.6649e-01 2.3306e-02 6.5604e-03 2.0205e-01 12 9 9 12 1 1 99.87 22.22 0.40 -0.00316 -0.00236 4 6 1 5 0 1849.030 26.83 20.00 22.22 7.00 10.7 881.30 225 198 -1156 103 -320 -73 27 241 4 -187 -281 496 625 271 -789 455 407 -500 -57 87 -494 196 -11 360 -50 -384 -70 262 22 -216 201 -350 17 -258 576 32 662 -212 -592 232 574 155 268 50 -74 -326 -251 -227 36 46 -138 216 29 -80 -31 299 404 280 -67 -207 -396 -262 -214 253 -158 -166 22 62 -192 -52 -47 -432 0 38 82 -359 134 145 -210 152 -16 414 -362 -410 -117 172 353 47 18 268 448 -189 -13 -100 143 477 313 528 -457 -75 -73 139 -124 -36 -192 -214 89 -182 20 160 378 -95 -340 103 -397 240 162 10 -109 6 -266 11 134 -50 236 -96 253 153 -275 116 -7 -176 -225 75 166 139 277 -223 0 -352 62 103 25 -233 -277 -183 -23 -82 145 145 98 79 -369 -214 225 314 44 20 -22 -17 50 -183 -152 284 -60 -188 -296 -136 -10 -27 -27 108 108 354 85 97 15 7 -17 43 -73 -305 202 290 110 311 -122 -416 78 27 25 418 -89 -29 -70 -158 -182 15 208 227 -476 189 -102 -280 -53 -113 293 -191 50 105 209 149 -188 149 -80 -71 -66 -7 -30 123 167 -166 126 145 143 117 -76 -91 -241 34 199 19 -8 138 70 186 -166 -68 -23 -235 4 5 -10 31 -153 102 -188 -198 -71 42 112 329 -29 -311 -63 -127 -155 -88 -289 -255 299 369 -148 1 264 233 97 83 -507 48 -156 -37 14 128 2 -108 -166 297 379 164 -466 262 226 -278 -33 52 -316 131 -8 263 -38 -294 -53 198 17 -168 157 -272 13 -195 438 24 490 -155 -430 167 413 114 198 38 -57 -261 -211 -199 33 42 -126 199 27 -75 -28 262 335 228 -54 -170 -331 -222 -180 211 -134 -145 19 56 -170 -46 -42 -388 0 34 74 -324 121 130 -182 128 -14 356 -321 -371 -109 163 339 45 16 250 424 -186 -13 -101 139 432 261 426 -384 -67 -68 128 -110 -31 -159 -180 78 -171 20 157 359 -89 -317 99 -401 246 167 11 -111 6 -258 10 135 -52 257 -106 279 167 -295 123 -7 -183 -233 78 169 139 277 -228 0 -386 69 113 28 -251 -299 -201 -26 -93 165 162 109 87 -397 -220 216 281 38 17 -21 -17 52 -201 -170 318 -68 -213 -331 -149 -10 -28 -29 116 118 396 97 111 18 8 -18 46 -75 -315 215 321 124 350 -136 -465 89 30 28 448 -94 -31 -75 -171 -201 18 250 282 -608 238 -129 -347 -65 -136 342 -217 57 121 248 183 -232 180 -92 -77 -69 -8 -33 143 201 -204 156 179 179 149 -98 -116 -310 44 255 25 -11 179 91 240 -211 -84 -28 -288 5 6 -12 39 -192 122 -216 -217 -75 43 118 357 -33 -362 -74 -144 -167 -88 -277 -239 278 347 -144 1 296 276 SS 20220128T151427.5Z 8063.635040 222 1 47.36 2 64.43 150.60 70.74 204.51 0.00 1 0.00 1 0 33 2.511e-03 2.276e-03 1.924e-03 1.715e-03 4.352051e-07 5.831627e-07 8.602377e-08 6.015781e-07 8.132429e-07 224.23 -2.00 3.51 -2.00 340.98 0.00e+00 2.470236e-04 1.598482e-04 1.716471e-05 3.005009e-05 2.240466e-04 275.24 -2.00 20.00 -2.00 338.52 0.00e+00 1.506138e-05 2.352294e-05 2.107012e-06 4.004427e-05 3.801731e-05 275.24 -2.00 20.00 -2.00 346.96 0.00e+00 4.054596e-04 6.820161e-05 2.291293e-05 2.073290e-05 1.078292e-04 275.24 -2.00 20.00 -2.00 345.59 0.00e+00 3.033583e+05 1.451488e+05 3.825061e+04 3.113665e+05 2.052081e+05 257.40 -2.00 11.22 -2.00 351.92 0.00e+00 3.497882e-01 2.433281e-03 2.769249e-03 2.883120e-03 2.804426e-03 224.23 -2.00 3.51 -2.00 331.16 0.00e+00 2.526532e-03 3.472672e-03 4.501845e-04 1.604573e-04 3.180348e-03 275.24 -2.00 20.00 -2.00 329.29 0.00e+00 2.303 0.000 319.50 362.20 4 6.2267e+00 2.3154e-03 1.6255e-02 2.3059e-03 3.5663e-03 4.5239e-02 5.9864e-04 2.5643e-03 4.0680e-04 8.2632e-04 -9.1798e-03 1.1328e-03 5.3215e-04 1.5204e-04 1.6201e-03 3.1395e-04 6.4089e-04 4.9060e-04 5.2214e-05 6.8164e-04 6.5749e-04 9.4692e-04 3.5062e-04 1.0378e-04 1.2100e-03 4.2997e-04 -1.2324e-03 1.4649e-03 1.8664e-04 1.0440e-04 2.0419e-03 1.0545e-04 2.5126e-05 3.5315e-06 9.2889e-07 3.8561e-05 -1.7652e-03 3.8451e-05 -2.7431e-01 1.5302e-01 1.5667e-02 6.4489e-03 2.1987e-01 12 9 8 11 8 0 99.91 22.11 0.27 -0.00177 -0.00046 12 3 1 5 0 3945.930 26.73 19.99 22.11 6.78 10.9 881.89 -44 136 -839 -902 12 377 -374 152 361 -344 188 65 620 451 166 -308 440 -420 142 -203 -160 71 -160 237 390 -327 43 -391 -27 291 -51 -379 171 107 28 -428 -382 302 -202 464 -55 -149 359 -400 287 -452 -67 232 36 49 -186 76 448 -44 -182 352 -113 266 -198 -202 610 68 667 128 83 -297 -325 -182 12 -350 -407 118 192 -127 343 -472 -1 184 41 -109 378 -447 -280 -363 -648 200 298 108 104 185 -350 229 75 95 -145 450 104 -230 131 34 -60 39 -44 322 -310 189 -57 243 312 186 -103 -240 261 123 -61 27 62 1 -93 90 -81 164 -99 -26 272 -105 89 -262 242 -154 -391 -499 117 -9 -181 -242 -51 29 -472 288 -3 368 154 -193 57 -340 0 -154 41 86 -115 69 -295 -38 138 79 -291 -140 -50 -244 252 356 90 -16 235 51 -148 46 -290 156 -155 291 -172 76 -122 -169 -96 -171 221 -127 198 111 30 -94 394 150 -2 209 -80 -21 -103 343 328 -69 177 33 190 -221 10 30 -20 150 -105 -181 -117 458 -122 407 287 -365 15 -233 21 44 -443 -7 18 -83 50 -11 -6 -154 -132 -131 411 292 133 -111 103 -38 238 -181 -241 77 -242 113 31 18 -307 -357 270 243 -130 -182 -148 -117 96 125 -243 -133 237 307 -135 45 -230 1 -46 61 -1 -348 252 -218 290 86 137 203 -18 53 -343 -391 5 183 -189 77 191 -194 110 38 365 264 97 -173 236 -226 79 -122 -102 48 -116 177 301 -258 34 -305 -21 233 -41 -304 133 82 21 -328 -293 222 -146 332 -40 -111 265 -300 223 -371 -58 214 34 47 -180 74 439 -43 -171 317 -97 216 -161 -168 518 59 567 109 72 -264 -299 -169 11 -311 -364 107 178 -118 313 -434 -1 168 36 -91 322 -386 -253 -336 -627 194 292 106 99 176 -345 233 78 101 -144 410 85 -181 107 31 -56 36 -38 264 -246 153 -50 229 307 183 -99 -223 241 120 -62 28 65 1 -96 89 -80 163 -102 -28 307 -122 103 -297 268 -165 -409 -519 122 -9 -188 -243 -50 30 -509 323 -4 412 169 -212 62 -381 0 -179 47 99 -129 76 -324 -39 127 67 -241 -117 -45 -238 263 391 102 -19 267 58 -165 51 -306 157 -160 307 -190 85 -141 -195 -113 -201 244 -131 197 112 32 -104 445 169 -2 234 -90 -24 -113 363 336 -72 187 34 209 -255 12 38 -26 193 -133 -226 -144 547 -144 453 322 -420 18 -290 26 53 -509 -7 18 -84 54 -12 -8 -187 -163 -163 520 374 173 -144 133 -49 306 -237 -319 102 -316 148 40 22 -378 -436 330 296 -162 -232 -184 -138 107 129 -238 -131 233 314 -147 51 -258 1 -46 56 -1 -290 209 -184 257 83 146 230