File name: Pandora166s1_PhiladelphiaPA_20240129_L2Fit_ffus5c6d20231015p1-8.txt File generation date: 20241031T041056.8Z Data description: Level 2 spectral fitting results file Data file version: ffus5c6p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 166 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora166_OF_v5d20210217.txt Instrument calibration file used: Pandora166s1_CF_v6d20231015.txt Level 1 file used: Pandora166s1_PhiladelphiaPA_20240129_L1_smca1c6d20231015p1-8.txt Full location name: Philadelphia, Pennsylvania; Philadelphia-Camden-Wilmington; North East Waste (NE Short location name: PhiladelphiaPA Country of location: United States Location latitude [deg]: 39.9919 Location longitude [deg]: -75.0811 Location altitude [m]: 6 Local noon date: 20240129 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 348 613 Nominal wavelengths inside fitting window [nm]: 322.5497 322.6891 322.8284 322.9677 323.1070 323.2463 323.3856 323.5249 323.6642 323.8034 323.9426 324.0819 324.2211 324.3603 324.4995 324.6387 324.7778 324.9170 325.0561 325.1953 325.3344 325.4735 325.6126 325.7517 325.8908 326.0299 326.1689 326.3080 326.4470 326.5860 326.7251 326.8641 327.0030 327.1420 327.2810 327.4199 327.5589 327.6978 327.8367 327.9757 328.1146 328.2534 328.3923 328.5312 328.6700 328.8089 328.9477 329.0865 329.2253 329.3641 329.5029 329.6417 329.7804 329.9192 330.0579 330.1967 330.3354 330.4741 330.6128 330.7515 330.8901 331.0288 331.1674 331.3061 331.4447 331.5833 331.7219 331.8605 331.9991 332.1376 332.2762 332.4147 332.5533 332.6918 332.8303 332.9688 333.1073 333.2457 333.3842 333.5226 333.6611 333.7995 333.9379 334.0763 334.2147 334.3531 334.4915 334.6298 334.7682 334.9065 335.0448 335.1831 335.3214 335.4597 335.5980 335.7362 335.8745 336.0127 336.1510 336.2892 336.4274 336.5656 336.7037 336.8419 336.9801 337.1182 337.2563 337.3945 337.5326 337.6707 337.8087 337.9468 338.0849 338.2229 338.3610 338.4990 338.6370 338.7750 338.9130 339.0510 339.1889 339.3269 339.4648 339.6028 339.7407 339.8786 340.0165 340.1544 340.2922 340.4301 340.5679 340.7058 340.8436 340.9814 341.1192 341.2570 341.3948 341.5325 341.6703 341.8080 341.9457 342.0834 342.2211 342.3588 342.4965 342.6342 342.7718 342.9095 343.0471 343.1847 343.3223 343.4599 343.5975 343.7351 343.8726 344.0102 344.1477 344.2852 344.4227 344.5602 344.6977 344.8352 344.9726 345.1101 345.2475 345.3849 345.5224 345.6598 345.7971 345.9345 346.0719 346.2092 346.3466 346.4839 346.6212 346.7585 346.8958 347.0331 347.1703 347.3076 347.4448 347.5820 347.7193 347.8565 347.9937 348.1308 348.2680 348.4051 348.5423 348.6794 348.8165 348.9536 349.0907 349.2278 349.3649 349.5019 349.6390 349.7760 349.9130 350.0500 350.1870 350.3240 350.4610 350.5979 350.7349 350.8718 351.0087 351.1456 351.2825 351.4194 351.5563 351.6931 351.8300 351.9668 352.1036 352.2404 352.3772 352.5140 352.6508 352.7875 352.9243 353.0610 353.1977 353.3345 353.4712 353.6078 353.7445 353.8812 354.0178 354.1544 354.2911 354.4277 354.5643 354.7009 354.8374 354.9740 355.1105 355.2471 355.3836 355.5201 355.6566 355.7931 355.9296 356.0660 356.2025 356.3389 356.4753 356.6117 356.7481 356.8845 357.0209 357.1572 357.2936 357.4299 357.5662 357.7025 357.8388 357.9751 358.1114 358.2477 358.3839 358.5201 358.6564 358.7926 358.9288 359.0649 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-435: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 436-701: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20240129T140634.1Z 8794.587894 322 1 6.52 2 72.45 133.44 88.89 275.60 0.00 1 0.00 1 0 33 1.496e-03 1.258e-03 1.377e-03 1.227e-03 1.525809e-06 4.128679e-07 8.721251e-08 4.264400e-07 4.761019e-07 224.34 -2.00 3.49 -2.00 341.19 0.00e+00 2.746220e-04 1.150682e-04 2.580609e-05 1.118178e-05 1.300537e-04 276.03 -2.00 20.00 -2.00 338.78 0.00e+00 -4.260722e-06 1.619573e-05 1.688937e-06 2.838024e-05 2.212692e-05 276.03 -2.00 20.00 -2.00 347.10 0.00e+00 3.724727e-04 4.761968e-05 2.844652e-05 1.228563e-05 6.354208e-05 276.03 -2.00 20.00 -2.00 345.83 0.00e+00 7.915376e+05 1.031552e+05 5.372407e+04 2.209773e+05 1.234760e+05 258.04 -2.00 11.19 -2.00 352.19 0.00e+00 5.622408e-01 1.877079e-03 4.723425e-03 4.720646e-03 1.828010e-03 224.34 -2.00 3.49 -2.00 331.15 0.00e+00 -4.629678e-03 1.869926e-03 4.626180e-04 7.882695e-05 1.415272e-03 276.03 -2.00 20.00 -2.00 329.40 0.00e+00 3.270 0.001 319.50 362.20 4 2.6445e+00 1.5549e-03 2.3079e-02 1.6399e-03 1.9150e-03 3.6208e-02 4.1989e-04 3.6710e-03 2.8959e-04 4.8038e-04 -9.5629e-05 8.2196e-04 8.5596e-04 1.1423e-04 9.6957e-04 -5.2920e-04 3.9321e-04 7.4755e-04 3.5696e-05 3.5982e-04 -7.3012e-04 6.4663e-04 4.8365e-04 7.3176e-05 6.9315e-04 6.4975e-03 3.3914e-03 8.8780e-04 3.2107e-04 6.9630e-05 9.1244e-04 -9.8291e-05 1.6176e-05 4.8069e-06 5.8211e-07 2.1235e-05 6.1804e-04 0.0000e+00 -1.4618e-01 9.5539e-02 2.9811e-02 3.9036e-03 1.0903e-01 12 9 9 12 9 1 99.66 19.36 0.28 0.00062 -0.00059 8 13 1 5 0 723.300 26.21 20.00 19.36 10.01 23.5 945.77 -339 -802 -265 -65 -149 -253 -62 211 -117 171 235 402 545 170 267 -477 96 10 97 -72 198 224 -107 -37 142 -53 -138 35 -98 -69 -156 112 -41 136 -75 15 -47 -259 -70 47 -25 185 76 25 -46 185 -218 8 -196 -79 -125 115 -12 -59 -204 164 -128 215 173 190 -73 162 337 8 -57 94 -183 -109 -121 15 -80 -74 -4 -123 233 151 80 342 91 -289 37 26 4 -163 -321 -122 -52 -179 -183 63 -257 71 151 -111 96 -4 205 -141 342 -89 -110 212 -17 32 35 -31 21 -183 91 224 94 0 -128 2 -20 17 51 67 -77 -110 236 -18 -14 190 31 139 26 -33 71 88 -122 19 -232 172 -259 -62 13 -105 19 44 -211 -151 186 105 65 -28 -83 37 -3 -241 157 -38 -70 -155 102 221 -180 93 138 98 -101 183 136 41 -86 -119 44 -57 37 -162 118 -47 -83 101 -65 -138 -54 -54 -141 195 10 -84 37 33 49 -106 -132 106 -2 111 -46 106 47 -8 -25 175 -259 139 102 2 -21 5 22 14 93 51 91 86 -22 -169 -5 -13 -145 -100 92 100 -33 -70 -104 42 -65 -14 78 13 -26 -12 13 17 -73 96 -42 75 2 -23 -21 20 121 28 -44 12 -121 -12 46 -15 87 16 -42 115 -236 -88 89 137 -111 -104 -24 71 -158 -148 71 -195 387 57 -187 178 101 -51 -142 -323 -106 -29 -71 -127 -32 113 -64 95 139 235 322 102 159 -271 53 6 52 -42 118 142 -72 -26 103 -39 -104 26 -75 -54 -121 87 -31 101 -57 11 -35 -186 -49 33 -17 134 55 18 -35 147 -179 7 -177 -71 -115 106 -11 -54 -187 146 -108 175 138 154 -60 135 278 6 -48 80 -161 -100 -110 13 -71 -66 -3 -112 209 137 73 312 80 -245 31 22 4 -146 -297 -115 -50 -171 -172 60 -244 69 154 -113 97 -4 182 -117 282 -79 -102 199 -15 28 29 -26 18 -167 87 224 91 0 -119 2 -20 17 53 69 -80 -111 235 -18 -14 199 33 155 29 -36 77 94 -126 20 -239 179 -268 -63 13 -107 19 47 -235 -166 204 114 70 -31 -93 42 -4 -273 174 -42 -77 -165 102 202 -159 82 129 95 -105 198 152 45 -98 -135 49 -64 40 -167 124 -50 -90 112 -74 -158 -63 -63 -160 212 10 -86 38 36 55 -120 -149 120 -2 127 -51 115 51 -9 -27 190 -286 159 121 3 -27 7 28 17 114 61 109 99 -25 -192 -6 -16 -179 -124 108 113 -36 -74 -113 48 -78 -17 96 16 -33 -15 17 22 -93 123 -54 96 2 -30 -27 26 154 34 -55 15 -149 -15 58 -19 110 20 -49 128 -249 -91 94 145 -123 -120 -28 81 -174 -151 69 -184 363 55 -181 180 111 -59 SS 20240129T141116.8Z 8794.591167 325 1 1.79 2 71.80 134.39 89.78 276.32 0.00 1 0.00 1 0 33 1.269e-03 1.148e-03 1.189e-03 1.074e-03 2.154620e-06 3.595967e-07 8.533154e-08 4.264450e-07 4.038193e-07 224.34 -2.00 3.49 -2.00 341.09 0.00e+00 -2.287553e-04 1.005125e-04 2.213717e-05 1.119618e-05 1.107124e-04 276.03 -2.00 20.00 -2.00 338.65 0.00e+00 8.377331e-05 1.416194e-05 1.474981e-06 2.838018e-05 1.875530e-05 276.03 -2.00 20.00 -2.00 347.03 0.00e+00 2.785982e-04 4.170241e-05 2.345587e-05 1.228434e-05 5.390262e-05 276.03 -2.00 20.00 -2.00 345.76 0.00e+00 5.136370e+05 9.004404e+04 5.096552e+04 2.209749e+05 1.049492e+05 258.04 -2.00 11.19 -2.00 352.21 0.00e+00 5.439003e-01 1.614547e-03 4.591816e-03 4.720562e-03 1.539334e-03 224.34 -2.00 3.49 -2.00 331.00 0.00e+00 -5.476751e-03 1.585836e-03 4.649347e-04 7.760215e-05 1.199027e-03 276.03 -2.00 20.00 -2.00 329.20 0.00e+00 3.160 0.001 319.50 362.20 4 1.2294e+00 1.3609e-03 2.2296e-02 1.6399e-03 1.6307e-03 1.3080e-02 3.6758e-04 3.5447e-03 2.8963e-04 4.0934e-04 5.3317e-04 7.1815e-04 8.2230e-04 1.1383e-04 8.2266e-04 -9.0971e-04 3.3683e-04 7.2261e-04 3.5637e-05 3.0570e-04 3.9682e-04 5.6168e-04 4.6099e-04 7.2897e-05 5.9017e-04 2.9152e-02 1.3621e-03 7.6560e-04 3.2676e-04 7.0958e-05 7.7553e-04 -1.4413e-04 1.4127e-05 4.6567e-06 5.7907e-07 1.8003e-05 8.4280e-04 0.0000e+00 -1.8433e-01 8.3660e-02 3.0239e-02 4.0071e-03 9.3254e-02 12 9 9 12 1 1 64.86 19.35 0.19 0.00084 -0.00094 9 51 1 5 0 178.930 26.21 20.00 19.35 10.29 23.4 947.65 115 -380 -188 30 -344 -62 -300 -128 296 81 259 -79 266 221 -121 -308 209 197 118 99 70 -280 211 -28 85 73 111 -247 47 33 246 -70 -100 74 24 -159 -6 -319 -5 246 -91 108 -225 -72 171 -34 -88 10 -151 42 -150 -85 -115 233 73 -7 106 128 173 -23 102 74 49 29 -14 -45 -42 44 -93 -26 31 -302 -29 156 8 -141 201 -24 176 -15 -42 107 -189 -245 -46 -257 -185 -109 30 184 -3 -1 30 -191 -26 72 97 246 168 220 77 65 47 60 -151 25 37 44 -126 55 -41 111 -28 -34 57 -57 159 43 -53 -230 40 61 9 26 91 -203 -62 -21 -36 199 -50 -30 -24 -73 -119 125 210 -84 -277 174 65 -107 -16 68 -18 -172 -74 -65 12 -30 41 32 -18 109 21 98 16 -145 114 182 36 27 14 39 192 -116 187 21 68 -35 62 135 -184 29 -105 82 -146 -73 97 -22 -7 -103 33 12 156 62 105 -98 6 26 -64 -19 -136 -245 94 -119 -75 23 139 129 -124 40 -104 -108 -126 47 -24 -103 -20 45 -23 76 36 -76 -59 58 65 -2 90 -88 17 39 -30 -15 -62 -13 -195 -47 46 41 -13 69 34 85 31 29 -34 189 -82 105 -143 29 48 281 248 137 -74 -65 -269 -133 86 -79 -92 -43 -80 29 -47 15 63 -92 88 -19 -170 6 73 5 51 -168 -83 14 -171 -32 -160 -71 166 48 157 -48 163 137 -73 -184 121 109 67 59 43 -183 143 -21 62 55 85 -188 36 26 194 -55 -78 56 18 -120 -5 -237 -3 176 -65 79 -168 -54 131 -26 -73 9 -135 37 -138 -78 -106 215 66 -6 91 104 140 -19 84 62 41 24 -12 -38 -37 40 -84 -23 28 -270 -27 142 7 -128 183 -22 156 -13 -36 90 -166 -219 -43 -244 -180 -106 29 171 -3 -1 30 -194 -26 68 85 204 140 194 72 62 43 53 -127 21 31 40 -122 54 -40 107 -26 -32 57 -58 164 45 -54 -231 39 60 9 27 99 -224 -69 -23 -38 211 -53 -31 -25 -75 -124 128 213 -86 -290 189 72 -118 -18 73 -20 -188 -83 -74 13 -34 45 35 -19 116 21 92 14 -127 106 179 37 30 15 44 216 -130 208 24 73 -37 65 145 -201 33 -118 94 -169 -84 110 -24 -8 -106 35 13 176 71 117 -108 7 29 -71 -21 -146 -260 101 -129 -83 26 163 158 -156 50 -130 -133 -153 57 -29 -118 -23 51 -27 92 44 -92 -70 65 70 -2 98 -100 20 47 -37 -19 -77 -16 -248 -60 58 52 -16 88 44 109 39 37 -43 235 -101 128 -174 36 59 350 311 165 -87 -73 -286 -140 91 -85 -103 -50 -94 33 -52 16 62 -89 82 -18 -166 6 80 6 SS 20240129T203553.7Z 8794.858260 575 1 49.18 2 74.62 229.72 136.10 9.73 0.00 1 0.00 1 0 33 1.211e-02 8.189e-03 9.792e-03 6.975e-03 -9.344493e-07 2.454847e-06 1.605289e-07 4.263904e-07 3.848271e-06 224.35 -2.00 3.49 -2.00 342.96 0.00e+00 1.032719e-04 6.844272e-04 8.847591e-05 1.122524e-05 1.018793e-03 276.03 -2.00 20.00 -2.00 340.88 0.00e+00 -1.879427e-04 9.202292e-05 4.490585e-06 2.838341e-05 1.792575e-04 276.03 -2.00 20.00 -2.00 348.37 0.00e+00 9.612108e-04 2.714566e-04 5.596186e-05 1.223052e-05 5.132263e-04 276.03 -2.00 20.00 -2.00 347.15 0.00e+00 6.871548e+05 6.233294e+05 7.350415e+04 2.209836e+05 9.895027e+05 258.04 -2.00 11.19 -2.00 352.19 0.00e+00 6.696207e-01 1.328605e-02 5.144386e-03 4.720411e-03 1.530392e-02 224.35 -2.00 3.49 -2.00 332.91 0.00e+00 1.294322e-02 1.459993e-02 4.859344e-04 9.533400e-05 1.154251e-02 276.03 -2.00 20.00 -2.00 331.82 0.00e+00 3.702 0.001 319.50 362.20 4 6.0015e+00 8.8691e-03 2.6207e-02 1.6408e-03 1.4790e-02 1.1195e-01 2.6092e-03 4.1988e-03 2.8927e-04 3.8249e-03 -1.5996e-02 5.0093e-03 1.1072e-03 1.2517e-04 7.7614e-03 4.2205e-03 2.8019e-03 8.4756e-04 3.4744e-05 2.8477e-03 -2.6916e-03 4.1241e-03 6.3345e-04 8.2221e-05 5.3881e-03 1.6348e-04 1.1565e-03 5.5759e-03 3.0035e-04 5.8900e-05 6.6796e-03 1.5561e-05 9.4998e-05 4.4522e-06 5.8151e-07 1.7216e-04 -3.0135e-03 0.0000e+00 8.9888e-01 5.6168e-01 2.3666e-02 3.3314e-03 8.3552e-01 12 9 8 11 8 0 99.77 19.37 1.41 -0.00301 -0.00282 13 2 1 5 0 3782.940 26.21 19.98 19.37 12.04 23.6 960.96 1007 -5371 6791 -964 1655 4204 -1568 -579 -1522 2395 -3349 106 -2334 -370 300 -3448 3893 447 3743 -2333 -1083 227 2860 3343 -92 1300 -1343 1642 -914 -2165 224 -800 1499 -2352 -581 1294 673 515 -509 -1034 -1859 -1976 -45 -586 -64 -794 730 -1002 670 -1221 476 1494 935 654 -263 1177 400 1085 2227 -124 43 -390 1237 -1349 -448 -808 1329 -620 1064 554 -1152 1050 192 133 -710 -1146 233 -744 179 -1218 551 -407 -141 1 -1377 1004 61 491 -328 1205 940 -180 619 -402 -660 -156 883 561 -242 789 -2387 536 -2161 493 -2207 -899 558 279 -1157 -572 1874 -688 191 184 -597 642 -680 322 -1402 -739 641 -1219 688 -838 775 -65 1200 675 795 341 -975 691 -862 2311 -1398 491 536 1426 138 -894 392 -641 -564 133 697 -673 361 231 -478 -384 -429 282 337 -418 456 -1269 -749 -568 1633 87 935 490 0 -362 -127 967 -26 868 -1114 83 119 -224 -206 903 424 94 -435 -803 39 -407 894 299 -24 -710 1320 -174 951 -608 -88 -379 250 -81 66 -199 -1051 739 931 -1201 992 -598 -172 -220 36 -234 569 -862 407 -329 -466 47 -439 827 17 887 405 404 -291 -2439 369 -1038 -30 -112 352 317 -20 -58 -794 -364 170 -144 167 863 -282 3 415 -424 -287 72 373 -151 322 357 -347 357 289 516 1257 -1004 51 -1318 -45 1180 -494 -127 -652 145 -37 1686 -2071 1269 -537 302 -938 -205 1753 -1012 218 -1197 1360 -232 441 1206 -511 -196 -545 879 -1369 43 -974 -152 118 -1326 1316 149 1231 -875 -442 100 1344 1713 -52 757 -822 976 -567 -1394 144 -518 918 -1449 -346 755 389 285 -271 -540 -991 -1102 -25 -338 -39 -515 508 -774 541 -1026 401 1255 798 562 -220 926 293 726 1445 -83 30 -274 854 -949 -320 -608 1032 -509 859 439 -925 842 158 111 -593 -950 191 -613 140 -911 392 -294 -106 0 -1173 876 55 445 -289 1039 829 -167 611 -410 -656 -141 688 389 -168 603 -2077 466 -1830 373 -1592 -632 412 229 -1062 -544 1695 -612 165 164 -577 643 -700 335 -1460 -731 605 -1154 658 -873 852 -75 1376 765 873 363 -1022 704 -895 2361 -1466 490 523 1381 143 -1014 456 -750 -645 147 757 -757 423 277 -577 -457 -501 318 374 -450 431 -1078 -584 -437 1333 80 938 537 0 -426 -151 1140 -30 998 -1234 86 121 -240 -230 1037 504 114 -543 -1006 47 -453 907 300 -25 -800 1543 -207 1095 -709 -105 -455 291 -91 70 -212 -1158 802 1039 -1441 1243 -822 -248 -316 51 -328 767 -1146 522 -403 -549 57 -555 1097 24 1189 511 465 -313 -2623 406 -1259 -39 -150 478 436 -27 -83 -1168 -532 246 -211 243 1262 -422 4 618 -631 -418 100 507 -204 432 486 -481 500 406 683 1536 -1155 53 -1357 -47 1234 -559 -154 -812 174 -41 1635 -1913 1075 -451 259 -839 -197 1904 -1255 SS 20240129T204849.2Z 8794.867237 584 1 50.87 2 76.55 232.20 135.65 14.15 0.00 1 0.00 1 0 33 1.528e-03 9.192e-04 1.617e-03 9.563e-04 2.734137e-06 3.487656e-07 8.411916e-08 4.263385e-07 4.852418e-07 224.35 -2.00 3.49 -2.00 344.42 0.00e+00 -2.193484e-05 9.932856e-05 2.136548e-05 1.138420e-05 1.283451e-04 276.03 -2.00 20.00 -2.00 342.62 0.00e+00 6.053493e-05 1.247001e-05 1.717677e-06 2.838801e-05 2.257661e-05 276.03 -2.00 20.00 -2.00 349.35 0.00e+00 6.433300e-04 3.707558e-05 3.695031e-05 1.229770e-05 6.488591e-05 276.03 -2.00 20.00 -2.00 348.36 0.00e+00 9.373396e+05 9.117863e+04 5.724970e+04 2.209705e+05 1.271826e+05 258.04 -2.00 11.19 -2.00 352.97 0.00e+00 7.465312e-01 2.215377e-03 5.653363e-03 4.721090e-03 2.007045e-03 224.35 -2.00 3.49 -2.00 334.19 0.00e+00 6.001971e-04 2.546471e-03 2.416578e-05 9.077753e-05 1.519393e-03 276.03 -2.00 20.00 -2.00 333.86 0.00e+00 4.195 0.001 319.50 362.20 4 2.5904e+00 1.2127e-03 2.9633e-02 1.6428e-03 1.7843e-03 5.3968e-03 4.1425e-04 4.7507e-03 2.8927e-04 4.8553e-04 -9.8062e-04 7.4497e-04 1.1483e-03 1.3679e-04 9.8000e-04 -1.0831e-03 4.5459e-04 9.0093e-04 3.5353e-05 3.6238e-04 8.8926e-04 6.3161e-04 5.6000e-04 9.5087e-05 6.8943e-04 3.6421e-03 -3.8097e-04 7.1620e-04 1.3964e-04 5.2766e-05 6.3385e-04 3.2415e-06 1.2647e-05 3.8906e-06 5.6415e-07 2.1741e-05 -1.3980e-03 0.0000e+00 -2.5954e-02 7.5440e-02 1.5896e-02 3.0106e-03 9.8235e-02 12 8 8 10 0 0 100.00 19.36 0.01 -0.00140 -0.00136 406 73 1 5 0 125.290 26.21 20.00 19.36 12.01 23.7 961.10 -117 -154 -114 179 -483 107 761 -186 868 -536 202 -322 475 -166 -7 -41 -218 551 -322 63 -384 739 -109 -84 -152 -217 -101 -37 4 -188 29 -60 19 157 130 160 106 -50 108 -12 109 -175 -36 -142 23 -143 94 177 21 -19 -123 27 46 -174 77 -3 214 237 -9 -207 0 -77 -33 26 -205 32 -98 118 -58 74 178 -168 -75 20 90 126 -1 9 -126 150 -237 101 -255 62 -11 -188 -136 -89 121 -134 270 41 -17 -156 48 28 -102 21 -47 274 121 -39 73 -130 -50 -2 49 70 60 77 116 64 39 231 54 99 -129 -24 -25 -208 11 -180 -53 71 122 153 74 77 -154 -36 -198 -80 28 -192 -94 -144 13 -43 -67 -26 -47 24 -112 8 1 129 55 23 -21 185 59 26 67 105 53 -4 149 -21 -155 93 -53 -52 0 93 64 -128 28 8 113 17 159 -11 -13 64 10 40 -146 58 -46 76 -88 -210 -65 -99 129 16 183 -42 -7 -57 3 -34 -63 13 4 -77 13 23 18 -26 73 -56 -83 -40 -3 -41 -20 29 13 -59 9 -2 -2 -84 -20 -78 108 -58 -19 75 -53 32 -104 25 -96 27 2 27 4 -69 144 15 64 -62 53 -27 -51 26 -1 147 72 16 56 -8 24 -42 87 -76 76 -115 14 72 -7 43 10 -58 43 -30 77 -150 179 -76 -20 -185 -20 -19 -19 -24 -18 32 -98 24 183 -48 232 -155 61 -100 148 -52 -2 -12 -58 140 -84 18 -120 252 -41 -34 -67 -101 -48 -18 2 -94 15 -31 9 76 62 76 49 -22 46 -5 46 -78 -17 -67 11 -77 55 112 14 -13 -87 19 33 -126 54 -2 132 135 -5 -117 0 -46 -20 15 -125 20 -67 83 -41 51 123 -119 -55 15 65 91 -1 6 -87 98 -150 64 -171 44 -8 -147 -110 -73 96 -105 217 34 -15 -144 43 23 -74 14 -30 196 95 -32 56 -92 -33 -1 34 54 51 68 99 53 32 193 48 93 -123 -23 -24 -193 10 -161 -48 70 128 166 81 83 -162 -36 -197 -79 28 -193 -94 -140 12 -41 -67 -28 -53 27 -123 9 1 141 63 26 -25 212 66 29 74 111 50 -3 116 -16 -130 86 -53 -57 0 108 75 -151 33 9 124 18 165 -12 -14 75 12 49 -183 73 -56 86 -92 -219 -70 -114 156 19 219 -51 -8 -70 3 -39 -70 14 4 -88 15 29 24 -37 107 -82 -120 -57 -4 -56 -26 37 16 -74 12 -3 -3 -118 -26 -96 125 -66 -22 96 -73 45 -150 37 -140 41 4 41 6 -106 221 24 100 -97 84 -42 -78 39 -2 213 104 24 83 -12 37 -61 118 -96 88 -131 16 86 -9 57 13 -78 53 -34 80 -148 173 -75 -21 -203 -25 -25 SS 20240129T210744.8Z 8794.880380 590 1 4.20 2 79.47 235.69 134.68 20.45 0.00 1 0.00 1 0 33 2.776e-03 1.988e-03 2.673e-03 1.899e-03 1.281866e-06 6.769746e-07 1.210758e-07 4.263477e-07 8.808128e-07 224.35 -2.00 3.49 -2.00 343.45 0.00e+00 3.123093e-04 1.921683e-04 3.024338e-05 1.130084e-05 2.254754e-04 276.03 -2.00 20.00 -2.00 341.43 0.00e+00 -4.463854e-05 2.459595e-05 2.872895e-06 2.838818e-05 4.110652e-05 276.03 -2.00 20.00 -2.00 348.73 0.00e+00 1.253391e-03 7.322282e-05 6.499979e-05 1.231601e-05 1.176815e-04 276.03 -2.00 20.00 -2.00 347.75 0.00e+00 1.811716e+06 1.753035e+05 8.066448e+04 2.209622e+05 2.295695e+05 258.04 -2.00 11.19 -2.00 353.03 0.00e+00 9.065028e-01 4.143760e-03 7.121320e-03 4.722992e-03 3.759927e-03 224.35 -2.00 3.49 -2.00 333.12 0.00e+00 -9.148571e-03 4.418450e-03 4.598697e-04 6.924398e-05 2.885179e-03 276.03 -2.00 20.00 -2.00 332.16 0.00e+00 5.262 0.003 319.50 362.20 4 1.6247e+00 2.2251e-03 3.7234e-02 1.6410e-03 3.0376e-03 5.5379e-04 7.3202e-04 5.9442e-03 2.8946e-04 8.7322e-04 1.7213e-03 1.4219e-03 1.4495e-03 1.2924e-04 1.7378e-03 7.6131e-05 7.9096e-04 1.1444e-03 3.5703e-05 6.5210e-04 -7.5498e-04 1.1757e-03 7.4450e-04 8.7802e-05 1.2029e-03 4.5748e-03 1.4863e-03 1.0213e-03 1.9422e-04 4.1901e-05 7.5294e-04 -7.6511e-05 2.4233e-05 5.5335e-06 5.5191e-07 3.9513e-05 -1.9762e-04 0.0000e+00 -2.9793e-01 1.3273e-01 2.7922e-02 2.2598e-03 1.5924e-01 12 9 9 12 1 1 99.59 19.36 0.20 -0.00020 -0.00114 5 13 1 5 0 700.100 26.21 20.01 19.36 12.57 23.3 964.60 -90 -1195 271 -1260 -2 -195 -638 266 119 379 -51 84 983 -27 733 -368 351 -837 236 19 -351 106 -229 282 301 70 285 -593 282 -500 766 369 544 -576 252 351 -370 306 -100 176 -299 -1 -511 -506 -244 -951 -59 -619 277 310 412 -458 -374 -70 191 -192 304 -218 509 64 -451 416 51 334 -25 108 -174 -29 -418 62 105 11 95 -42 254 -345 202 -31 712 -188 -49 -116 -353 398 170 242 -264 -71 -87 -61 185 -170 -52 190 232 -183 -269 -387 286 177 -566 392 199 -109 87 36 271 187 25 -41 199 191 133 49 -23 177 53 17 -289 -144 119 153 73 -34 -140 -235 5 -332 -59 -75 -18 -54 -110 181 31 117 246 -1 122 -176 34 193 -185 -43 77 -189 -349 -27 39 -198 -200 4 14 -112 446 179 -47 -159 49 313 173 138 167 270 -251 -134 -138 103 -46 146 -494 -47 104 30 73 -94 -95 -417 79 14 -43 68 184 68 143 160 253 167 -36 -34 -220 -96 -86 148 1 345 168 -181 74 -112 92 -37 -201 -262 -67 90 27 -87 -54 156 -12 -195 -220 38 364 124 115 0 -156 103 9 10 -55 79 107 235 77 -76 -33 -46 -77 -45 210 -124 152 10 -180 -25 -340 207 -150 7 -44 191 -114 -120 37 133 59 36 115 -158 -30 8 108 -64 -104 76 -393 131 1 -124 189 -112 223 16 -20 -262 60 -316 -1 -60 -211 91 43 144 -20 34 393 -11 285 -137 123 -284 81 7 -140 45 -105 138 156 38 157 -332 160 -291 450 218 312 -326 140 195 -204 162 -51 88 -152 -1 -281 -285 -143 -590 -39 -433 201 229 308 -346 -285 -53 142 -138 207 -141 326 41 -296 276 34 222 -17 76 -129 -22 -320 47 80 8 74 -33 199 -270 158 -24 538 -137 -35 -83 -262 307 136 200 -225 -60 -73 -51 157 -149 -47 177 212 -160 -215 -289 212 141 -479 336 165 -86 66 27 211 155 23 -38 178 168 116 43 -22 170 52 17 -284 -138 112 143 69 -34 -145 -249 6 -350 -61 -77 -18 -54 -110 184 31 117 242 -1 124 -189 38 211 -201 -46 82 -205 -389 -31 44 -223 -222 5 15 -119 440 165 -41 -140 45 307 180 151 189 308 -291 -155 -159 118 -51 156 -530 -52 117 35 85 -112 -114 -505 94 16 -46 73 203 78 170 191 298 197 -43 -41 -261 -112 -97 168 1 397 197 -220 93 -148 125 -50 -271 -352 -88 117 35 -108 -66 193 -16 -258 -296 51 467 151 135 0 -186 129 12 13 -75 107 147 327 109 -107 -47 -65 -109 -65 302 -179 220 14 -257 -34 -470 284 -207 10 -62 269 -162 -165 49 167 70 43 138 -192 -38 10 144 -84 -131 88 -439 142 1 -135 209 -130 280 21