File name: Pandora187s1_PittsburghPA_20211118_L2Fit_fnvs4c2d20210902p1-8.txt File generation date: 20251128T075826.7Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c2p1-8 Local principal investigator: Lukas Valin Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 187 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora187_OF_v4d20210517.txt Instrument calibration file used: Pandora187s1_CF_v2d20210902.txt Level 1 file used: Pandora187s1_PittsburghPA_20211118_L1_smca1c2d20210902p1-8.txt Full location name: Pittsburgh, PA - Lawrenceville ACHD (USEPA AQS ID 42-003-0008) Short location name: PittsburghPA Country of location: United States Location latitude [deg]: 40.4655 Location longitude [deg]: -79.9608 Location altitude [m]: 265 Local noon date: 20211118 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 885 1427 Nominal wavelengths inside fitting window [nm]: 400.0232 400.1561 400.2890 400.4219 400.5547 400.6876 400.8204 400.9532 401.0860 401.2188 401.3516 401.4843 401.6171 401.7498 401.8825 402.0152 402.1479 402.2806 402.4132 402.5459 402.6785 402.8111 402.9437 403.0763 403.2089 403.3415 403.4740 403.6066 403.7391 403.8716 404.0041 404.1366 404.2690 404.4015 404.5339 404.6663 404.7987 404.9311 405.0635 405.1959 405.3282 405.4606 405.5929 405.7252 405.8575 405.9898 406.1221 406.2543 406.3866 406.5188 406.6510 406.7832 406.9154 407.0475 407.1797 407.3118 407.4440 407.5761 407.7082 407.8403 407.9723 408.1044 408.2364 408.3685 408.5005 408.6325 408.7645 408.8965 409.0284 409.1604 409.2923 409.4242 409.5561 409.6880 409.8199 409.9517 410.0836 410.2154 410.3472 410.4790 410.6108 410.7426 410.8744 411.0061 411.1378 411.2696 411.4013 411.5330 411.6646 411.7963 411.9279 412.0596 412.1912 412.3228 412.4544 412.5860 412.7175 412.8491 412.9806 413.1121 413.2436 413.3751 413.5066 413.6381 413.7695 413.9010 414.0324 414.1638 414.2952 414.4265 414.5579 414.6893 414.8206 414.9519 415.0832 415.2145 415.3458 415.4771 415.6083 415.7395 415.8708 416.0020 416.1332 416.2643 416.3955 416.5267 416.6578 416.7889 416.9200 417.0511 417.1822 417.3133 417.4443 417.5753 417.7064 417.8374 417.9684 418.0993 418.2303 418.3612 418.4922 418.6231 418.7540 418.8849 419.0158 419.1466 419.2775 419.4083 419.5391 419.6699 419.8007 419.9315 420.0623 420.1930 420.3238 420.4545 420.5852 420.7159 420.8465 420.9772 421.1078 421.2385 421.3691 421.4997 421.6303 421.7609 421.8914 422.0220 422.1525 422.2830 422.4135 422.5440 422.6745 422.8049 422.9354 423.0658 423.1962 423.3266 423.4570 423.5874 423.7177 423.8481 423.9784 424.1087 424.2390 424.3693 424.4996 424.6298 424.7601 424.8903 425.0205 425.1507 425.2809 425.4110 425.5412 425.6713 425.8015 425.9316 426.0617 426.1917 426.3218 426.4519 426.5819 426.7119 426.8419 426.9719 427.1019 427.2318 427.3618 427.4917 427.6216 427.7515 427.8814 428.0113 428.1412 428.2710 428.4008 428.5307 428.6605 428.7902 428.9200 429.0498 429.1795 429.3092 429.4390 429.5687 429.6983 429.8280 429.9577 430.0873 430.2169 430.3465 430.4761 430.6057 430.7353 430.8648 430.9943 431.1239 431.2534 431.3829 431.5123 431.6418 431.7712 431.9007 432.0301 432.1595 432.2889 432.4183 432.5476 432.6770 432.8063 432.9356 433.0649 433.1942 433.3234 433.4527 433.5819 433.7112 433.8404 433.9696 434.0987 434.2279 434.3570 434.4862 434.6153 434.7444 434.8735 435.0026 435.1316 435.2607 435.3897 435.5187 435.6477 435.7767 435.9057 436.0346 436.1636 436.2925 436.4214 436.5503 436.6792 436.8080 436.9369 437.0657 437.1945 437.3233 437.4521 437.5809 437.7097 437.8384 437.9671 438.0958 438.2245 438.3532 438.4819 438.6106 438.7392 438.8678 438.9964 439.1250 439.2536 439.3822 439.5107 439.6392 439.7678 439.8963 440.0247 440.1532 440.2817 440.4101 440.5385 440.6670 440.7954 440.9237 441.0521 441.1805 441.3088 441.4371 441.5654 441.6937 441.8220 441.9502 442.0785 442.2067 442.3349 442.4631 442.5913 442.7195 442.8476 442.9758 443.1039 443.2320 443.3601 443.4882 443.6163 443.7443 443.8723 444.0004 444.1284 444.2563 444.3843 444.5123 444.6402 444.7681 444.8960 445.0239 445.1518 445.2797 445.4075 445.5354 445.6632 445.7910 445.9188 446.0466 446.1743 446.3021 446.4298 446.5575 446.6852 446.8129 446.9405 447.0682 447.1958 447.3234 447.4510 447.5786 447.7062 447.8338 447.9613 448.0888 448.2163 448.3438 448.4713 448.5988 448.7262 448.8537 448.9811 449.1085 449.2359 449.3633 449.4906 449.6180 449.7453 449.8726 449.9999 450.1272 450.2545 450.3817 450.5089 450.6362 450.7634 450.8906 451.0177 451.1449 451.2720 451.3992 451.5263 451.6534 451.7804 451.9075 452.0346 452.1616 452.2886 452.4156 452.5426 452.6696 452.7965 452.9235 453.0504 453.1773 453.3042 453.4311 453.5579 453.6848 453.8116 453.9384 454.0652 454.1920 454.3188 454.4456 454.5723 454.6990 454.8257 454.9524 455.0791 455.2058 455.3324 455.4590 455.5857 455.7123 455.8388 455.9654 456.0920 456.2185 456.3450 456.4715 456.5980 456.7245 456.8509 456.9774 457.1038 457.2302 457.3566 457.4830 457.6094 457.7357 457.8621 457.9884 458.1147 458.2410 458.3672 458.4935 458.6197 458.7460 458.8722 458.9984 459.1245 459.2507 459.3768 459.5030 459.6291 459.7552 459.8813 460.0073 460.1334 460.2594 460.3855 460.5115 460.6374 460.7634 460.8894 461.0153 461.1412 461.2672 461.3931 461.5189 461.6448 461.7706 461.8965 462.0223 462.1481 462.2739 462.3996 462.5254 462.6511 462.7769 462.9026 463.0282 463.1539 463.2796 463.4052 463.5308 463.6565 463.7821 463.9076 464.0332 464.1587 464.2843 464.4098 464.5353 464.6608 464.7862 464.9117 465.0371 465.1625 465.2880 465.4133 465.5387 465.6641 465.7894 465.9147 466.0400 466.1653 466.2906 466.4159 466.5411 466.6664 466.7916 466.9168 467.0419 467.1671 467.2923 467.4174 467.5425 467.6676 467.7927 467.9178 468.0428 468.1679 468.2929 468.4179 468.5429 468.6679 468.7928 468.9178 469.0427 469.1676 469.2925 469.4174 469.5422 469.6671 469.7919 469.9167 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-706: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 707-1249: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20211118T210420.7Z 7992.878018 537 1 46.04 2 81.66 235.46 97.49 60.69 0.00 1 0.00 1 0 49 8.958e-04 7.251e-04 5.683e-04 5.027e-04 2.075462e+03 1.040271e+02 3.264282e+02 4.549765e+02 1.904447e+02 278.97 -2.00 20.00 -2.00 448.39 0.00e+00 1.175565e-04 6.047881e-05 4.577610e-05 2.158470e-05 9.806201e-05 278.97 -2.00 20.00 -2.00 457.26 0.00e+00 1.277099e-03 5.700377e-06 9.654238e-05 2.167194e-05 1.014833e-05 278.97 -2.00 20.00 -2.00 441.74 0.00e+00 1.709475e+06 7.044381e+04 1.432193e+05 2.807040e+05 1.328435e+05 260.44 -2.00 11.20 -2.00 459.05 0.00e+00 7.696358e-01 1.286027e-02 2.838102e-02 1.111265e-02 2.826267e-02 223.16 -2.00 3.49 -2.00 456.59 0.00e+00 1.499954e-06 1.680536e-06 2.063567e-06 1.420869e-06 3.539873e-06 278.97 -2.00 20.00 -2.00 457.26 0.00e+00 6.483 0.005 397.00 473.00 4 4.5628e+00 5.8055e-04 1.6554e-02 5.0433e-04 9.6284e-04 -4.6966e-02 7.5109e-04 3.3633e-03 3.4496e-04 1.2168e-03 4.1562e-03 3.7695e-04 4.4332e-04 1.4796e-04 6.1449e-04 6.5849e-03 1.4183e-04 7.6561e-05 3.9465e-05 2.2653e-04 -3.9208e-03 7.0975e-05 5.8630e-05 2.0424e-05 1.0924e-04 6.8542e-03 -5.1058e-02 3.2946e-04 3.8238e-04 8.6591e-05 5.4352e-04 -6.5467e-05 6.8985e-06 1.7363e-06 6.3615e-07 1.2037e-05 9.7972e-05 1.0124e-05 7.8752e-07 8.2927e-07 1.6410e-05 1.6989e-04 -8.9816e-05 -2.6839e-01 5.7798e-02 7.6885e-03 6.6399e-03 9.0088e-02 10 0 0 10 0 0 98.62 18.78 1.12 0.00017 -0.00960 107 33 1 4 0 430.180 22.09 15.00 18.78 12.97 12.4 919.72 -76 139 111 43 -252 -149 -184 40 -11 203 83 193 39 103 35 17 147 52 81 13 293 52 -124 -312 -213 -345 -266 -70 26 71 -16 -119 -120 -356 -437 -444 -201 -15 -101 42 -58 -124 -185 -163 18 -86 -75 -294 -213 -208 24 41 62 25 -27 73 41 -85 -32 99 131 68 26 20 -44 4 73 146 88 100 15 102 106 137 108 133 38 32 29 70 112 54 186 57 147 196 205 108 251 115 33 82 161 250 147 87 65 102 40 60 16 9 93 92 14 55 0 93 -42 17 46 23 75 -33 26 -11 52 -95 -66 27 82 108 124 66 44 -60 69 57 29 133 45 50 30 -1 -26 -16 -5 87 40 -45 49 -21 13 -95 -29 -83 24 48 77 78 53 -56 -48 -60 -11 -17 -37 -39 -60 -103 -59 -82 -38 28 -83 -38 7 -51 -26 -10 -37 -150 -36 -83 -56 -46 -63 -138 -102 -26 -62 -91 -49 -9 -44 -168 -85 -8 -71 -151 -133 -152 -177 -81 -74 -59 -62 -104 -100 -77 -19 -155 -46 -50 -30 -66 -51 -108 -90 28 -143 -225 -90 -174 -32 -43 -113 -81 -126 -169 -197 -78 -65 -70 -50 -46 -17 4 62 171 151 177 28 54 -14 105 -67 5 -93 -100 -131 -85 -95 -80 -99 -42 64 -70 19 -46 51 -28 0 -80 -9 39 -4 97 93 112 128 210 180 238 35 112 69 139 100 34 38 64 24 14 2 20 -2 15 50 -2 -1 -19 37 30 27 18 8 31 92 71 108 151 132 108 159 133 158 72 -44 88 70 36 -6 87 35 35 122 160 63 104 100 40 183 95 78 43 27 -15 43 69 126 133 -55 -38 -33 -25 -80 0 -89 89 47 -45 -34 -14 27 51 41 5 -87 44 -20 -55 -7 -71 -92 7 -53 -101 21 -19 115 71 52 24 -23 -11 -23 9 -26 29 -46 2 39 -62 8 -33 16 -18 -45 -73 3 27 -45 -59 -80 -52 -39 -43 -82 -36 -25 -30 -33 -61 -71 -132 -59 -52 -35 -42 -64 -56 -82 17 -96 -12 -52 30 71 -5 -5 40 12 48 52 56 47 60 58 65 77 0 5 40 -13 2 5 -82 -54 50 6 46 30 47 32 0 43 14 -19 -53 12 -1 -101 -42 -47 5 -23 -17 -14 -61 -44 -51 3 -45 36 -29 -7 34 34 34 56 -5 46 46 33 26 32 49 10 75 37 107 30 13 43 8 -33 -1 10 54 -24 -78 -49 -5 -41 56 -2 9 29 15 3 -26 37 24 -4 -71 -73 -31 -48 7 -17 4 -79 2 -7 8 -54 -71 -32 -88 22 -15 -16 61 -69 -60 -56 -67 -43 3 -8 -78 -10 27 -13 33 112 84 121 80 16 8 -13 -37 10 5 10 47 18 -18 47 60 7 -25 8 -24 -63 -58 16 -3 70 21 41 -43 81 64 24 -140 -83 -105 23 -6 117 48 118 24 63 21 10 87 31 49 8 177 31 -77 -187 -124 -202 -161 -44 16 45 -10 -78 -75 -212 -254 -260 -122 -9 -67 28 -38 -79 -117 -102 11 -54 -47 -181 -130 -128 15 27 41 16 -18 48 27 -55 -21 65 88 48 19 14 -31 3 51 105 64 72 11 74 75 95 71 90 25 21 19 47 79 40 139 43 107 147 157 83 194 89 25 63 123 192 113 66 50 77 32 47 13 7 70 72 11 45 0 73 -32 13 35 18 60 -26 21 -8 41 -75 -52 22 68 91 101 55 37 -50 56 46 24 109 36 39 24 -1 -21 -13 -4 72 33 -37 41 -17 10 -76 -23 -69 20 40 62 62 43 -45 -39 -47 -9 -14 -32 -35 -51 -88 -50 -70 -32 24 -72 -33 6 -44 -22 -8 -30 -120 -28 -64 -47 -38 -54 -117 -84 -22 -53 -75 -41 -7 -38 -147 -74 -7 -60 -124 -110 -126 -150 -70 -65 -51 -53 -88 -84 -66 -17 -136 -41 -43 -27 -55 -40 -88 -74 23 -123 -199 -77 -149 -27 -36 -100 -70 -108 -142 -164 -65 -55 -60 -43 -38 -13 3 46 122 107 126 20 38 -11 76 -48 4 -74 -83 -119 -79 -89 -76 -96 -39 57 -60 16 -40 46 -26 0 -76 -9 37 -3 84 78 91 103 177 154 216 33 103 64 127 94 32 36 58 23 13 2 20 -1 14 49 -2 -1 -19 35 30 26 17 7 30 89 69 104 140 116 95 139 119 142 67 -42 84 65 34 -6 85 34 34 118 152 59 96 93 38 178 92 78 43 28 -15 43 70 129 134 -56 -39 -34 -25 -80 0 -90 90 48 -44 -34 -14 27 52 42 5 -89 45 -20 -57 -7 -74 -97 7 -55 -103 21 -18 115 71 53 24 -23 -11 -23 9 -28 30 -48 2 41 -67 8 -36 17 -20 -47 -76 3 29 -48 -65 -88 -57 -43 -47 -90 -40 -28 -34 -37 -69 -79 -148 -67 -60 -41 -49 -75 -66 -95 19 -111 -14 -59 35 83 -6 -6 47 14 55 59 64 52 67 64 73 88 0 6 46 -15 3 7 -99 -65 60 7 55 35 55 37 0 51 16 -23 -64 15 -1 -128 -53 -59 6 -28 -21 -18 -78 -56 -65 4 -58 46 -37 -9 42 43 43 70 -7 58 57 42 33 41 62 13 94 47 141 39 16 55 11 -43 -1 13 72 -33 -105 -66 -7 -55 75 -2 12 40 20 5 -36 51 33 -6 -98 -101 -42 -66 10 -24 6 -107 3 -9 11 -74 -97 -43 -118 30 -20 -22 83 -95 -83 -78 -94 -59 4 -11 -108 -14 36 -19 45 149 111 160 108 22 11 -18 -51 14 7 14 64 25 -25 65 83 10 -35 11 -34 -88 -81 22 -5 98 28 56 SQ 20211118T211543.2Z 7992.885917 540 1 19.24 2 83.47 237.46 95.62 62.56 0.00 1 0.00 1 0 49 1.622e-03 1.324e-03 1.673e-03 1.381e-03 2.826452e+03 2.865818e+02 4.050748e+02 4.549318e+02 3.451830e+02 278.97 -2.00 20.00 -2.00 449.68 0.00e+00 3.913542e-05 1.725401e-04 4.851961e-05 2.335169e-05 1.772010e-04 278.97 -2.00 20.00 -2.00 458.16 0.00e+00 1.508443e-03 1.591833e-05 1.143567e-04 2.168164e-05 1.843546e-05 278.97 -2.00 20.00 -2.00 444.11 0.00e+00 2.152690e+06 1.938468e+05 1.718545e+05 2.806123e+05 2.407923e+05 260.44 -2.00 11.20 -2.00 459.82 0.00e+00 9.693717e-01 3.411052e-02 3.375175e-02 1.088074e-02 5.115843e-02 223.16 -2.00 3.49 -2.00 457.49 0.00e+00 -5.365523e-06 4.486868e-06 2.307196e-06 1.426109e-06 6.408787e-06 278.97 -2.00 20.00 -2.00 458.00 0.00e+00 7.979 0.009 397.00 473.00 4 5.2857e+00 1.6505e-03 2.0390e-02 5.0901e-04 1.7656e-03 -8.6970e-02 2.1938e-03 4.1651e-03 3.7944e-04 2.2709e-03 1.2309e-02 1.0518e-03 5.4650e-04 1.5394e-04 1.0882e-03 1.2486e-02 4.1524e-04 8.5933e-05 4.2083e-05 4.0917e-04 -8.7383e-03 2.0601e-04 6.1297e-05 2.1014e-05 1.9696e-04 2.4893e-03 -9.5913e-02 8.2752e-04 4.6087e-04 9.9997e-05 1.0119e-03 -7.2586e-05 1.9358e-05 2.1366e-06 6.1940e-07 2.1796e-05 1.4252e-04 2.8438e-05 1.0837e-06 8.2215e-07 2.9709e-05 2.7127e-03 -1.2275e-04 -3.6679e-01 1.6162e-01 4.2127e-03 7.1031e-03 1.6224e-01 12 9 1 12 1 1 99.77 18.77 1.47 0.00271 -0.01100 25 19 1 4 0 733.360 22.09 15.01 18.77 12.91 12.4 919.62 -240 391 161 -298 240 15 -258 163 44 374 -49 -240 17 276 542 93 123 -168 -138 -315 -70 -98 -62 -283 -190 -449 -526 82 -250 33 127 -128 -700 -524 -687 -508 -140 -207 -217 -163 -113 18 -100 -96 -257 -190 -357 -98 239 157 -43 262 -39 -99 70 191 140 256 116 123 -43 91 -84 115 25 -181 -255 311 94 279 502 145 148 482 69 50 84 -117 92 -30 132 231 47 161 109 64 124 -2 205 242 -32 115 176 15 84 137 186 371 333 486 301 17 319 261 107 217 83 258 119 267 16 46 29 -34 -89 112 60 -185 -2 147 149 59 205 135 12 -208 181 49 -69 63 149 -194 68 165 -22 -119 -211 225 -40 38 347 -36 -46 -315 55 -150 12 -179 -93 187 16 245 -163 -197 -46 -55 -84 -163 -273 -175 -18 13 -272 65 -170 -59 134 -309 -108 104 -208 -411 -257 56 -117 -126 -82 -162 -146 -60 -54 25 12 13 -87 -140 -36 -261 -272 -368 -18 -300 -370 -59 113 -139 -39 -175 -102 -197 -60 47 -223 -133 -65 59 19 -332 6 44 -101 -114 64 -148 71 82 -70 52 33 -307 23 -60 100 8 -119 -34 -82 6 73 283 265 152 -46 -38 145 -66 -101 -220 14 -159 -138 -225 -116 -159 -135 16 -21 -223 -53 -187 40 -75 -240 -138 -263 153 -88 61 -340 -68 -31 135 146 110 -91 -43 -55 202 108 141 265 99 123 -142 18 -47 -114 230 78 202 103 307 118 81 19 91 124 140 111 222 222 492 41 300 123 163 164 143 -41 89 536 234 60 109 124 130 55 184 -14 191 27 234 204 51 264 171 -5 -128 -81 121 -6 128 149 -27 16 -41 19 189 -49 156 -172 -235 47 -235 35 97 -5 -26 -84 93 2 -93 -232 5 -52 -24 -188 -194 -99 -224 -40 -113 -53 -148 -14 -23 -53 25 21 23 152 54 75 10 75 64 -65 -103 -138 -75 36 172 -243 -7 -148 -118 -65 -158 -113 -145 -55 -219 -33 -2 -92 -139 -124 -164 -72 -13 -54 30 -217 -44 -47 -221 4 98 116 -24 -19 56 -3 -18 96 77 92 -12 11 262 152 -88 37 -22 -100 161 -84 3 109 5 46 151 195 79 -64 25 66 -32 153 -123 113 29 106 -140 -8 150 17 106 -68 -145 17 33 27 6 78 -110 -73 8 167 89 73 -31 92 104 -10 -112 101 -50 93 14 59 121 40 169 20 14 22 -27 27 67 132 -47 -77 52 -42 136 35 -43 -17 -3 -89 -6 -53 115 -58 -155 -92 35 -76 19 -1 -26 3 -104 2 -92 34 -190 121 -209 -88 -166 -38 -25 -115 -134 -170 -59 -120 -139 -107 -14 -32 -39 -19 -27 166 18 239 -29 -67 56 26 55 54 -100 45 54 -65 101 92 -29 -72 -41 31 167 19 -40 67 -68 110 191 66 -113 186 76 -148 118 8 -130 79 22 187 -25 -121 9 139 275 48 63 -87 -72 -165 -37 -51 -34 -150 -99 -233 -281 45 -134 18 69 -73 -388 -277 -356 -265 -76 -117 -126 -95 -65 10 -56 -53 -144 -107 -199 -54 130 85 -24 152 -23 -58 41 112 81 148 67 71 -26 56 -52 72 16 -116 -167 207 63 185 327 93 93 295 41 28 50 -69 52 -18 83 150 31 108 74 44 88 -2 147 173 -22 81 126 10 60 98 132 260 231 332 204 12 224 190 76 155 58 178 86 191 12 32 21 -24 -63 78 42 -129 -1 104 108 44 155 104 9 -159 137 37 -51 46 106 -137 48 117 -16 -87 -156 167 -30 28 255 -26 -34 -237 42 -117 10 -140 -71 140 12 177 -119 -147 -35 -43 -64 -127 -215 -139 -14 10 -215 51 -132 -46 106 -247 -85 79 -160 -301 -186 42 -87 -99 -65 -129 -114 -46 -41 19 10 11 -71 -115 -29 -212 -217 -289 -14 -238 -299 -48 93 -115 -32 -141 -83 -162 -48 39 -186 -109 -51 47 15 -251 5 35 -79 -91 52 -120 58 66 -56 41 26 -236 18 -46 77 6 -94 -26 -63 4 51 191 177 102 -31 -25 96 -43 -68 -157 11 -128 -115 -200 -108 -149 -124 14 -18 -186 -44 -159 34 -67 -224 -124 -235 140 -77 51 -282 -54 -25 112 121 96 -83 -38 -49 177 98 127 240 87 111 -130 17 -45 -110 224 76 198 100 295 112 77 18 84 114 129 104 210 207 443 35 261 107 137 143 129 -38 83 503 212 55 102 116 122 52 169 -13 171 24 215 193 50 254 167 -5 -124 -78 117 -6 129 151 -27 16 -41 19 190 -50 158 -173 -235 46 -234 36 100 -5 -26 -83 96 2 -93 -233 5 -53 -25 -188 -199 -100 -221 -39 -110 -52 -148 -15 -23 -53 26 22 23 159 58 81 11 83 71 -72 -112 -147 -79 38 184 -267 -8 -166 -131 -72 -175 -126 -163 -62 -250 -36 -2 -103 -158 -144 -192 -85 -15 -64 35 -257 -51 -55 -258 4 113 134 -28 -22 65 -3 -21 111 87 103 -13 13 294 173 -102 44 -27 -123 200 -101 3 137 6 57 184 236 96 -77 30 80 -40 192 -157 146 38 139 -184 -10 195 22 139 -90 -193 23 44 36 8 105 -148 -96 10 215 114 93 -41 120 138 -13 -151 135 -67 123 18 79 161 54 226 27 19 30 -37 37 94 187 -67 -109 74 -59 194 50 -61 -25 -5 -130 -9 -78 168 -85 -228 -135 52 -111 28 -2 -37 5 -152 3 -135 49 -279 176 -302 -127 -238 -55 -37 -164 -193 -246 -85 -176 -205 -160 -22 -48 -57 -27 -40 238 26 343 -42 -95 82 39 82 80 -148 66 80 -95 150 137 -44 -110 -62 47 253 29 -61 99 -99 168 287 99