File name: Pandora55s1_QueensNY_20201225_L2Fit_fnvs5c10d20200414p1-8.txt File generation date: 20260625T173313.0Z Data description: Level 2 spectral fitting results file Data file version: fnvs5c10p1-8 Local principal investigator: James Szykman Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 55 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora55_OF_v3d20190723.txt Instrument calibration file used: Pandora55s1_CF_v10d20200414.txt Level 1 file used: Pandora55s1_QueensNY_20201225_L1_smca1c10d20200414p1-8.txt Full location name: Queens College NYSDEC (USEPA AQS ID 36-081-0124) Short location name: QueensNY Country of location: USA Location latitude [deg]: 40.7361 Location longitude [deg]: -73.8215 Location altitude [m]: 25 Local noon date: 20201225 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 960 1508 Nominal wavelengths inside fitting window [nm]: 400.0926 400.2242 400.3557 400.4873 400.6189 400.7504 400.8819 401.0134 401.1449 401.2764 401.4079 401.5393 401.6708 401.8022 401.9336 402.0650 402.1964 402.3278 402.4591 402.5905 402.7218 402.8531 402.9844 403.1157 403.2470 403.3782 403.5095 403.6407 403.7719 403.9031 404.0343 404.1655 404.2966 404.4278 404.5589 404.6900 404.8211 404.9522 405.0833 405.2143 405.3454 405.4764 405.6074 405.7384 405.8694 406.0004 406.1313 406.2623 406.3932 406.5241 406.6550 406.7859 406.9168 407.0476 407.1785 407.3093 407.4401 407.5709 407.7017 407.8325 407.9632 408.0940 408.2247 408.3554 408.4861 408.6168 408.7475 408.8782 409.0088 409.1394 409.2700 409.4006 409.5312 409.6618 409.7924 409.9229 410.0534 410.1840 410.3145 410.4449 410.5754 410.7059 410.8363 410.9667 411.0972 411.2276 411.3579 411.4883 411.6187 411.7490 411.8793 412.0097 412.1400 412.2702 412.4005 412.5308 412.6610 412.7912 412.9215 413.0517 413.1818 413.3120 413.4422 413.5723 413.7024 413.8325 413.9626 414.0927 414.2228 414.3528 414.4829 414.6129 414.7429 414.8729 415.0029 415.1329 415.2628 415.3927 415.5227 415.6526 415.7825 415.9124 416.0422 416.1721 416.3019 416.4317 416.5615 416.6913 416.8211 416.9509 417.0806 417.2103 417.3401 417.4698 417.5995 417.7291 417.8588 417.9884 418.1181 418.2477 418.3773 418.5069 418.6365 418.7660 418.8956 419.0251 419.1546 419.2841 419.4136 419.5431 419.6725 419.8020 419.9314 420.0608 420.1902 420.3196 420.4490 420.5783 420.7077 420.8370 420.9663 421.0956 421.2249 421.3541 421.4834 421.6126 421.7418 421.8710 422.0002 422.1294 422.2586 422.3877 422.5169 422.6460 422.7751 422.9042 423.0333 423.1623 423.2914 423.4204 423.5494 423.6784 423.8074 423.9364 424.0653 424.1943 424.3232 424.4521 424.5810 424.7099 424.8388 424.9676 425.0965 425.2253 425.3541 425.4829 425.6117 425.7404 425.8692 425.9979 426.1266 426.2553 426.3840 426.5127 426.6414 426.7700 426.8986 427.0273 427.1559 427.2845 427.4130 427.5416 427.6701 427.7987 427.9272 428.0557 428.1842 428.3126 428.4411 428.5695 428.6979 428.8263 428.9547 429.0831 429.2115 429.3398 429.4682 429.5965 429.7248 429.8531 429.9814 430.1096 430.2379 430.3661 430.4943 430.6225 430.7507 430.8789 431.0070 431.1352 431.2633 431.3914 431.5195 431.6476 431.7756 431.9037 432.0317 432.1598 432.2878 432.4158 432.5437 432.6717 432.7996 432.9276 433.0555 433.1834 433.3113 433.4391 433.5670 433.6948 433.8227 433.9505 434.0783 434.2061 434.3338 434.4616 434.5893 434.7170 434.8447 434.9724 435.1001 435.2278 435.3554 435.4831 435.6107 435.7383 435.8659 435.9934 436.1210 436.2485 436.3761 436.5036 436.6311 436.7585 436.8860 437.0135 437.1409 437.2683 437.3957 437.5231 437.6505 437.7778 437.9052 438.0325 438.1598 438.2871 438.4144 438.5417 438.6689 438.7962 438.9234 439.0506 439.1778 439.3050 439.4321 439.5593 439.6864 439.8135 439.9407 440.0677 440.1948 440.3219 440.4489 440.5759 440.7029 440.8299 440.9569 441.0839 441.2108 441.3378 441.4647 441.5916 441.7185 441.8454 441.9722 442.0991 442.2259 442.3527 442.4795 442.6063 442.7331 442.8598 442.9866 443.1133 443.2400 443.3667 443.4934 443.6200 443.7467 443.8733 443.9999 444.1265 444.2531 444.3797 444.5062 444.6328 444.7593 444.8858 445.0123 445.1388 445.2652 445.3917 445.5181 445.6445 445.7709 445.8973 446.0237 446.1501 446.2764 446.4027 446.5290 446.6553 446.7816 446.9079 447.0341 447.1604 447.2866 447.4128 447.5390 447.6651 447.7913 447.9174 448.0436 448.1697 448.2958 448.4219 448.5479 448.6740 448.8000 448.9260 449.0520 449.1780 449.3040 449.4299 449.5559 449.6818 449.8077 449.9336 450.0595 450.1854 450.3112 450.4370 450.5629 450.6887 450.8145 450.9402 451.0660 451.1917 451.3175 451.4432 451.5689 451.6945 451.8202 451.9459 452.0715 452.1971 452.3227 452.4483 452.5739 452.6994 452.8250 452.9505 453.0760 453.2015 453.3270 453.4524 453.5779 453.7033 453.8287 453.9541 454.0795 454.2049 454.3302 454.4556 454.5809 454.7062 454.8315 454.9568 455.0820 455.2073 455.3325 455.4577 455.5829 455.7081 455.8333 455.9584 456.0836 456.2087 456.3338 456.4589 456.5840 456.7090 456.8341 456.9591 457.0841 457.2091 457.3341 457.4590 457.5840 457.7089 457.8338 457.9587 458.0836 458.2085 458.3334 458.4582 458.5830 458.7078 458.8326 458.9574 459.0822 459.2069 459.3317 459.4564 459.5811 459.7057 459.8304 459.9551 460.0797 460.2043 460.3289 460.4535 460.5781 460.7027 460.8272 460.9517 461.0762 461.2007 461.3252 461.4497 461.5741 461.6986 461.8230 461.9474 462.0718 462.1961 462.3205 462.4448 462.5692 462.6935 462.8178 462.9420 463.0663 463.1905 463.3148 463.4390 463.5632 463.6874 463.8115 463.9357 464.0598 464.1839 464.3080 464.4321 464.5562 464.6802 464.8043 464.9283 465.0523 465.1763 465.3003 465.4242 465.5482 465.6721 465.7960 465.9199 466.0438 466.1677 466.2915 466.4154 466.5392 466.6630 466.7868 466.9105 467.0343 467.1580 467.2817 467.4055 467.5291 467.6528 467.7765 467.9001 468.0238 468.1474 468.2710 468.3945 468.5181 468.6417 468.7652 468.8887 469.0122 469.1357 469.2592 469.3826 469.5061 469.6295 469.7529 469.8763 469.9996 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-712: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 713-1261: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20201225T211227.2Z 7664.883648 573 1 50.38 2 87.46 235.80 63.68 94.55 0.00 1 0.00 1 7 262 1.208e-02 7.724e-03 4.616e-04 3.559e-04 6.692848e+03 6.888394e+01 3.833069e+02 3.157147e+02 2.382021e+03 276.55 -2.00 20.00 -2.00 451.57 0.00e+00 2.520821e-03 4.648261e-05 5.105171e-05 1.999562e-05 1.309720e-03 276.55 -2.00 20.00 -2.00 459.31 0.00e+00 3.091423e-03 3.346109e-06 2.125498e-05 7.570450e-06 1.116332e-04 226.82 -2.00 2.16 -2.00 446.62 0.00e+00 1.092734e+07 4.997841e+04 4.950389e+04 1.971454e+05 1.763124e+06 258.49 -2.00 11.21 -2.00 461.00 0.00e+00 1.279919e+00 8.409742e-03 1.359575e-02 6.923813e-03 3.747492e-01 223.15 -2.00 3.51 -2.00 458.64 0.00e+00 -2.745235e-05 1.095415e-06 2.255302e-06 1.001652e-06 4.596735e-05 276.55 -2.00 20.00 -2.00 459.03 0.00e+00 14.696 0.058 397.00 473.00 4 2.3804e+00 4.7869e-04 4.0148e-02 3.6754e-04 1.3006e-02 -2.4474e-01 7.1052e-04 8.4008e-03 3.6971e-04 1.9427e-02 4.6398e-02 2.7179e-04 1.1135e-03 1.1401e-04 7.5361e-03 7.1613e-02 1.0102e-04 2.8323e-04 3.0171e-05 2.8033e-03 -5.6634e-02 5.9274e-05 1.9951e-04 1.5383e-05 1.6033e-03 7.3289e-03 -3.2020e-01 3.2081e-04 7.8273e-05 1.1752e-04 7.8698e-03 6.7601e-05 4.0674e-06 2.0005e-06 4.7041e-07 1.2357e-04 -4.5727e-05 5.6532e-06 2.9858e-06 3.9690e-07 1.7379e-04 -7.1941e-03 1.7133e-04 2.1941e-01 3.7672e-02 5.3502e-03 9.0860e-03 1.0620e+00 12 10 8 10 0 0 99.94 22.88 1.69 -0.00719 -0.00182 284 54 1 4 0 175.500 25.79 20.00 22.88 11.72 27.1 1074.58 -1951 -2453 -3624 -4963 -5188 -4507 -2798 -1616 -891 -628 -499 -1193 -312 -673 -184 278 276 393 398 541 814 -42 -1590 -3263 -4381 -3776 -1377 397 1576 1812 1503 149 -1493 -3170 -4398 -3451 -1688 600 1076 1160 284 -251 -521 -672 126 -153 -259 -1361 -1762 -1427 333 1321 1166 1349 1409 1164 1489 955 836 814 1773 2250 2733 2325 2676 2953 3373 4123 4000 3753 3315 2779 2071 1815 1372 -160 -723 -872 -572 805 1850 2154 2743 2944 3072 3337 3439 3355 3542 3352 3067 2717 2350 2761 2524 2237 2469 2054 1655 1443 1094 809 1114 1302 1647 1977 1901 1531 1058 874 493 460 870 563 521 299 271 570 159 -144 352 310 247 250 131 207 -193 -155 -92 -317 -653 -959 -1090 -1311 -1014 -1135 -991 -1026 -724 -969 -785 -774 -925 -1025 -1055 -1101 -738 -945 -1065 -964 -1322 -1556 -1751 -1462 -1455 -1332 -1109 -1096 -1034 -859 -1032 -1095 -895 -1073 -940 -1084 -1401 -1350 -1135 -1240 -1359 -1321 -1931 -1969 -1924 -1534 -1396 -1534 -1219 -1260 -1502 -1537 -1477 -1357 -1365 -1494 -1527 -1293 -1416 -1289 -1603 -1404 -1570 -1135 -1092 -1170 -979 -982 -815 -1019 -707 -980 -995 -1076 -745 -891 -717 -1256 -1140 -1365 -1684 -1458 -1471 -1362 -1456 -1431 -1173 -1148 -1127 -1044 -791 -794 -825 -653 -837 -727 -769 -638 -429 -712 -677 -1043 -945 -902 -886 -881 -1064 -1153 -1100 -782 -411 -221 -244 -403 -278 -131 -183 189 436 462 653 458 159 187 232 257 438 636 911 1337 1596 1709 1754 1659 1444 1153 764 670 716 769 666 846 894 741 762 819 952 816 851 723 781 787 900 863 995 739 956 1030 958 1067 996 952 714 932 1263 1545 1562 1449 1240 1152 1145 1137 963 1066 933 897 941 821 722 880 1046 1048 1145 1201 909 784 657 412 522 518 663 667 533 463 249 248 223 195 47 -8 -39 52 94 185 329 363 483 430 109 75 24 -18 146 -13 -96 -106 -155 -241 -349 -444 -413 -434 -407 -340 -466 -465 -391 -638 -825 -783 -809 -825 -724 -691 -718 -894 -848 -874 -832 -837 -646 -594 -196 -182 -6 -284 -323 -264 -131 -129 -80 -76 -55 -83 -141 -258 -191 -160 -108 -165 -299 -365 -240 -280 -247 -166 -35 6 -14 36 16 113 164 72 71 50 43 276 394 461 567 455 458 414 512 349 184 9 -113 -193 -229 -78 -99 -29 200 307 488 572 549 489 380 384 185 168 -8 -78 -158 -103 61 -11 24 -152 -220 -271 -202 -169 -142 -237 -282 -168 37 158 352 415 492 520 356 234 -10 -65 -71 -99 14 88 -5 25 -5 -7 -34 57 68 140 51 -108 -119 -146 -77 33 83 40 -6 46 -39 -72 -149 -187 -259 -238 -176 -158 -96 -161 -153 -141 -120 -117 -50 -28 -26 -71 -192 -343 -469 -319 -247 -90 -59 -111 -242 -375 -435 -414 -403 -429 -606 -690 -676 -614 -492 -246 53 290 379 335 117 21 -64 -184 -99 -57 116 162 268 309 252 102 138 145 210 300 379 421 465 349 275 325 412 594 900000 -962 -1207 -1767 -2411 -2513 -2199 -1381 -805 -446 -315 -251 -601 -157 -340 -93 142 141 200 204 278 418 -22 -801 -1620 -2165 -1882 -695 204 817 944 782 77 -749 -1560 -2288 -1704 -857 309 559 599 146 -128 -264 -342 65 -78 -140 -729 -938 -766 182 691 611 708 785 647 825 526 458 450 995 1205 1467 1328 1531 1613 1875 2314 2253 2110 1850 1536 1136 1043 772 -88 -390 -468 -312 454 1075 1204 1548 1675 1769 1950 2045 2022 2134 2016 1840 1627 1417 1672 1532 1357 1490 1235 987 851 640 474 662 794 1033 1261 1215 965 658 539 307 291 527 344 318 182 164 344 96 -88 219 197 160 164 87 136 -127 -101 -60 -204 -415 -604 -682 -825 -646 -734 -646 -671 -475 -638 -516 -507 -607 -677 -703 -712 -486 -625 -700 -622 -836 -1028 -1154 -919 -933 -871 -744 -752 -720 -602 -730 -741 -606 -723 -660 -758 -987 -921 -782 -852 -911 -885 -1244 -1262 -1271 -1016 -968 -1084 -853 -865 -1021 -1040 -1007 -942 -962 -1073 -1113 -940 -1024 -916 -1123 -987 -1120 -819 -765 -831 -697 -695 -570 -710 -499 -715 -754 -829 -570 -666 -513 -867 -802 -955 -1159 -1046 -1089 -1025 -1102 -1080 -883 -864 -849 -782 -581 -577 -603 -483 -604 -534 -563 -475 -306 -485 -467 -708 -645 -621 -608 -594 -707 -764 -746 -533 -301 -168 -191 -336 -230 -110 -150 154 335 356 501 351 129 153 195 217 371 531 733 1061 1187 1282 1323 1247 1155 930 639 572 608 640 546 687 733 628 636 693 819 712 755 631 690 695 794 756 866 645 829 883 818 916 869 849 644 814 1082 1259 1299 1174 1048 1007 977 979 836 934 833 817 838 737 649 784 947 941 1031 1086 815 733 615 397 505 496 627 629 514 445 243 243 217 187 45 -8 -38 51 93 181 317 348 465 421 106 74 23 -17 145 -13 -93 -105 -154 -240 -349 -442 -403 -416 -384 -319 -441 -444 -378 -632 -809 -787 -829 -849 -745 -715 -751 -924 -889 -927 -887 -886 -670 -620 -200 -186 -6 -298 -350 -288 -142 -139 -87 -83 -60 -89 -153 -285 -214 -182 -123 -191 -340 -421 -279 -327 -290 -195 -41 7 -16 42 18 130 190 84 83 59 51 321 448 531 646 522 531 469 585 406 220 11 -139 -240 -286 -96 -123 -36 243 379 598 703 678 610 479 488 232 214 -10 -104 -211 -136 81 -14 31 -203 -297 -368 -273 -228 -192 -324 -387 -228 50 214 471 552 656 701 489 319 -14 -90 -100 -138 19 122 -8 35 -7 -11 -49 82 96 199 74 -158 -177 -219 -114 49 124 59 -9 71 -59 -108 -225 -285 -395 -362 -268 -238 -149 -250 -237 -218 -187 -181 -77 -43 -40 -112 -295 -534 -731 -492 -387 -140 -93 -173 -385 -605 -707 -656 -643 -694 -1000 -1155 -1134 -1020 -803 -399 82 445 596 520 187 33 -104 -303 -165 -95 191 264 435 506 419 168 230 243 351 501 632 704 785 580 460 541 697 991 900000