File name: Pandora154s1_SaltLakeCityUT_20231223_L2Fit_ffus5c7d20220523p1-8.txt File generation date: 20241004T031725.8Z Data description: Level 2 spectral fitting results file Data file version: ffus5c7p1-8 Local principal investigator: Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 154 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora154_OF_v2d20220401.txt Instrument calibration file used: Pandora154s1_CF_v7d20220523.txt Level 1 file used: Pandora154s1_SaltLakeCityUT_20231223_L1_smca1c7d20220523p1-8.txt Full location name: University of Utah, William Browning Building Short location name: SaltLakeCityUT Country of location: United States Location latitude [deg]: 40.7663 Location longitude [deg]: -111.8478 Location altitude [m]: 1455 Local noon date: 20231223 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 359 625 Nominal wavelengths inside fitting window [nm]: 322.5186 322.6580 322.7974 322.9368 323.0762 323.2155 323.3549 323.4942 323.6336 323.7729 323.9122 324.0515 324.1908 324.3301 324.4693 324.6086 324.7478 324.8871 325.0263 325.1655 325.3047 325.4439 325.5830 325.7222 325.8613 326.0005 326.1396 326.2787 326.4178 326.5569 326.6960 326.8351 326.9741 327.1132 327.2522 327.3912 327.5302 327.6692 327.8082 327.9472 328.0862 328.2251 328.3641 328.5030 328.6419 328.7808 328.9197 329.0586 329.1975 329.3363 329.4752 329.6140 329.7528 329.8917 330.0305 330.1692 330.3080 330.4468 330.5855 330.7243 330.8630 331.0017 331.1405 331.2792 331.4178 331.5565 331.6952 331.8338 331.9725 332.1111 332.2497 332.3883 332.5269 332.6655 332.8041 332.9426 333.0812 333.2197 333.3582 333.4967 333.6352 333.7737 333.9122 334.0506 334.1891 334.3275 334.4660 334.6044 334.7428 334.8812 335.0196 335.1579 335.2963 335.4346 335.5730 335.7113 335.8496 335.9879 336.1262 336.2644 336.4027 336.5409 336.6792 336.8174 336.9556 337.0938 337.2320 337.3702 337.5084 337.6465 337.7847 337.9228 338.0609 338.1990 338.3371 338.4752 338.6133 338.7513 338.8894 339.0274 339.1654 339.3034 339.4414 339.5794 339.7174 339.8554 339.9933 340.1312 340.2692 340.4071 340.5450 340.6829 340.8208 340.9586 341.0965 341.2343 341.3721 341.5100 341.6478 341.7856 341.9233 342.0611 342.1989 342.3366 342.4744 342.6121 342.7498 342.8875 343.0252 343.1628 343.3005 343.4381 343.5758 343.7134 343.8510 343.9886 344.1262 344.2638 344.4013 344.5389 344.6764 344.8140 344.9515 345.0890 345.2265 345.3639 345.5014 345.6389 345.7763 345.9137 346.0511 346.1886 346.3259 346.4633 346.6007 346.7380 346.8754 347.0127 347.1500 347.2873 347.4246 347.5619 347.6992 347.8364 347.9737 348.1109 348.2481 348.3853 348.5225 348.6597 348.7969 348.9341 349.0712 349.2083 349.3455 349.4826 349.6197 349.7567 349.8938 350.0309 350.1679 350.3050 350.4420 350.5790 350.7160 350.8530 350.9899 351.1269 351.2638 351.4008 351.5377 351.6746 351.8115 351.9484 352.0853 352.2221 352.3590 352.4958 352.6326 352.7694 352.9062 353.0430 353.1798 353.3166 353.4533 353.5900 353.7268 353.8635 354.0002 354.1368 354.2735 354.4102 354.5468 354.6835 354.8201 354.9567 355.0933 355.2299 355.3664 355.5030 355.6396 355.7761 355.9126 356.0491 356.1856 356.3221 356.4586 356.5950 356.7315 356.8679 357.0043 357.1407 357.2771 357.4135 357.5499 357.6862 357.8226 357.9589 358.0952 358.2315 358.3678 358.5041 358.6404 358.7766 358.9129 359.0491 359.1853 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 67: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Oxygen dimer effective temperature [K] Column 72: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Ozone effective temperature [K] Column 83: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 89: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 90: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 91: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 92: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 93: Sulfur dioxide effective temperature [K] Column 94: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 95: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 96: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 97: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 98: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 99: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 100: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 101: Lower limit used for wavelength scaling [nm] Column 102: Upper limit used for wavelength scaling [nm] Column 103: Order of smoothing polynomial Column 104: Smoothing polynomial coefficient, order 0 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 1 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 2 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 119: Smoothing polynomial coefficient, order 3 Column 120: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 121: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 122: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 123: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 124: Smoothing polynomial coefficient, order 4 Column 125: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 126: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 127: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 128: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 129: Mean value of measured data inside fitting window [same units as measurements] Column 130: Offset polynomial coefficient, order 0 Column 131: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 132: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 133: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 134: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 135: Wavelength change polynomial coefficient, order 0 Column 136: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 137: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 138: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 139: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 140: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 141: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 142: Resolution change polynomial coefficient, order 0 Column 143: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 144: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 145: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 146: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 147: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 148: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 149: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 150: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 151: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 152: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 153: Atmospheric variability [%], 999=no atmospheric variability was determined Column 154: Wavelength effective temperature [°C], 999=no effective temperature given Column 155: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 156: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 157: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 158: Number of bright count cycles Column 159: Number of dark count cycles Column 160: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 161: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 162: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 163: Integration time [ms] Column 164: Temperature at electronics board [°C], 999=no temperature signal Column 165: Spectrometer control temperature [°C], 999=no temperature signal Column 166: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 167: Temperature in head sensor [°C], 999=no temperature signal Column 168: Humidity in head sensor [%], -9=no humidity signal Column 169: Pressure in head sensor [hPa], -9=no pressure signal Columns 170-436: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 437-703: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20231223T202853.3Z 8757.853395 350 1 20.98 2 65.81 195.69 99.45 52.37 0.00 1 0.00 1 0 33 2.271e-03 2.159e-03 1.668e-03 1.559e-03 7.713876e-07 5.084030e-07 7.178983e-08 3.509790e-07 7.196555e-07 222.45 -2.00 3.47 -2.00 340.13 0.00e+00 -1.797872e-04 1.389491e-04 1.962995e-05 9.288428e-06 1.966803e-04 268.11 -2.00 20.00 -2.00 337.61 0.00e+00 -2.608536e-05 2.134381e-05 1.730981e-06 2.347555e-05 3.420362e-05 268.11 -2.00 20.00 -2.00 346.24 0.00e+00 2.193742e-04 6.055015e-05 1.781029e-05 8.884138e-06 9.474899e-05 268.11 -2.00 20.00 -2.00 344.83 0.00e+00 3.366654e+05 1.249134e+05 4.029708e+04 1.800641e+05 1.801248e+05 251.26 -2.00 11.21 -2.00 351.66 0.00e+00 3.766962e-01 2.009548e-03 3.107144e-03 1.173603e-03 2.480762e-03 222.45 -2.00 3.47 -2.00 330.51 0.00e+00 -1.603683e-03 2.319088e-03 3.948235e-04 6.735721e-05 2.332020e-03 268.11 -2.00 20.00 -2.00 328.58 0.00e+00 2.424 0.000 319.50 362.20 4 5.7301e+00 2.0166e-03 1.4317e-02 1.3354e-03 3.0658e-03 2.9385e-02 4.9959e-04 2.2824e-03 2.3497e-04 7.1478e-04 -2.9706e-04 9.8151e-04 5.1973e-04 7.2992e-05 1.4265e-03 -6.0315e-04 4.7876e-04 5.1513e-04 1.9145e-05 5.5757e-04 -4.6277e-04 7.6939e-04 3.5986e-04 5.1757e-05 1.0263e-03 7.1240e-04 -1.0574e-04 1.2564e-03 2.5275e-04 5.8659e-05 1.7608e-03 7.1651e-05 2.1566e-05 3.7318e-06 4.6385e-07 3.2096e-05 2.8646e-02 -4.2825e-05 1.5829e+00 1.3208e-01 2.1841e-02 3.2874e-03 1.8835e-01 12 9 9 12 5 1 99.91 18.81 0.26 0.02865 0.02953 6 3 1 5 0 2996.370 24.56 19.99 18.81 11.04 9.0 805.64 -263 -334 137 -112 -356 -108 484 -56 189 -455 -84 254 620 60 -414 356 221 225 11 -651 120 65 190 -132 141 255 -265 74 -19 -232 -326 122 345 142 -28 178 -202 -201 546 -149 106 69 -56 -53 127 -160 -310 10 -59 78 -185 -265 233 -277 -153 151 372 -165 66 -251 -2 -2 -219 51 -240 68 174 -4 -95 133 244 -171 104 65 10 -214 -64 289 -108 185 -4 24 -171 36 -72 -227 557 -175 202 -209 -137 -87 -306 291 -33 339 -31 134 -15 -300 -12 338 222 361 -84 7 -163 -6 1 168 -116 383 -400 -103 190 -487 307 -12 56 291 222 118 -72 -56 -14 -83 -328 28 -101 -150 -99 -92 52 22 196 44 -156 -290 -11 135 -147 296 206 -213 -22 -74 33 -151 -75 158 268 -59 228 19 -74 -55 -360 53 48 -123 43 43 -61 -70 159 -218 -25 53 -22 -117 67 63 -337 230 -140 301 -122 -97 124 -240 117 34 -39 50 -131 -39 -129 50 175 -84 92 -68 1232 -49 -109 -122 360 -165 37 14 -257 -142 -130 -62 -255 29 -1 -154 -139 -180 389 -66 48 81 162 -24 -7 -13 -126 135 26 -123 79 53 70 -50 576 -207 87 37 -40 135 -185 -55 -237 -93 8 191 57 0 -120 58 238 149 -326 -270 185 -235 -359 288 -250 222 226 174 251 75 -297 -71 161 -813 28 268 -697 64 343 159 900000 -131 -161 65 -57 -193 -61 282 -33 115 -290 -56 171 421 41 -281 233 141 140 7 -429 84 48 147 -107 118 216 -227 63 -16 -200 -284 107 295 120 -23 149 -169 -164 434 -117 84 55 -45 -43 105 -137 -279 10 -58 77 -185 -267 236 -282 -154 146 345 -146 57 -221 -2 -2 -199 46 -218 63 165 -3 -92 125 229 -163 100 63 10 -205 -61 276 -101 167 -3 21 -158 35 -70 -228 564 -177 198 -205 -136 -89 -324 312 -35 333 -28 111 -12 -270 -12 328 208 319 -71 6 -144 -6 1 171 -116 370 -384 -100 192 -512 324 -12 60 297 222 117 -73 -60 -15 -95 -374 32 -111 -162 -105 -97 55 23 205 45 -158 -294 -12 148 -165 331 226 -230 -24 -81 37 -173 -86 177 298 -65 247 20 -72 -49 -308 45 43 -118 44 46 -68 -78 178 -244 -27 58 -24 -118 68 66 -362 252 -156 338 -139 -111 138 -254 118 34 -40 53 -145 -43 -140 55 193 -92 99 -72 1249 -50 -113 -127 379 -181 42 17 -316 -175 -158 -75 -303 34 -1 -170 -150 -197 440 -78 57 95 181 -25 -7 -13 -131 148 30 -144 92 62 83 -61 701 -252 106 44 -49 165 -229 -68 -293 -115 10 226 66 0 -139 68 278 175 -386 -308 200 -241 -350 275 -242 219 232 187 272 80 -299 -66 140 -692 23 227 -610 59 345 171 900000 SS 20231223T203846.8Z 8757.860264 353 1 10.00 2 66.35 198.10 97.98 54.06 0.00 1 0.00 1 0 33 1.849e-03 1.737e-03 1.274e-03 1.205e-03 1.342935e-06 3.913527e-07 7.155440e-08 3.509778e-07 5.860594e-07 222.45 -2.00 3.47 -2.00 340.01 0.00e+00 -4.855130e-04 1.072515e-04 2.236485e-05 9.289547e-06 1.604249e-04 268.11 -2.00 20.00 -2.00 337.48 0.00e+00 9.957473e-05 1.645817e-05 2.321872e-06 2.347547e-05 2.777310e-05 268.11 -2.00 20.00 -2.00 346.15 0.00e+00 1.338240e-04 4.681451e-05 1.692388e-05 8.889225e-06 7.718703e-05 268.11 -2.00 20.00 -2.00 344.75 0.00e+00 1.257383e+05 9.623875e+04 4.388379e+04 1.800620e+05 1.470460e+05 251.26 -2.00 11.21 -2.00 351.76 0.00e+00 3.829246e-01 1.534606e-03 3.196628e-03 1.173526e-03 2.028449e-03 222.45 -2.00 3.47 -2.00 330.33 0.00e+00 1.192945e-03 1.728956e-03 1.503465e-03 6.373216e-05 1.901077e-03 268.11 -2.00 20.00 -2.00 328.36 0.00e+00 2.476 0.000 319.50 362.20 4 4.6326e+00 1.5564e-03 1.4617e-02 1.3355e-03 2.4971e-03 2.2370e-02 3.8497e-04 2.3289e-03 2.3507e-04 5.8406e-04 -1.6389e-03 7.5966e-04 5.3119e-04 7.2413e-05 1.1652e-03 -1.7040e-03 3.6051e-04 5.5745e-04 1.9135e-05 4.5469e-04 1.0828e-03 5.8937e-04 4.0497e-04 5.1275e-05 8.3893e-04 2.0909e-03 -7.1869e-03 9.4684e-04 2.9596e-04 6.0825e-05 1.4264e-03 5.7707e-05 1.6544e-05 3.8455e-06 4.6257e-07 2.6138e-05 2.8231e-02 -6.9570e-05 1.4283e+00 1.0120e-01 2.4800e-02 3.3556e-03 1.5256e-01 12 9 9 12 5 1 99.40 18.88 0.18 0.02823 0.02894 7 8 1 5 0 1249.180 24.56 20.01 18.88 12.07 9.0 809.93 90 -10 466 486 12 -19 16 258 341 -550 -175 -119 296 -32 -267 -60 0 357 39 -555 -143 -217 18 -187 -58 108 -86 -160 172 247 -137 44 251 195 -45 -94 -129 100 81 261 449 50 -248 -52 172 81 -133 237 -210 42 -286 -91 22 -333 -97 121 -319 212 -98 -355 -111 -208 88 198 -170 -150 -65 -171 -115 124 223 -25 106 92 320 142 66 160 -63 353 145 40 -77 -264 -289 -195 161 12 15 91 -103 156 -185 116 7 245 -84 158 143 -83 96 55 115 148 -100 -172 -24 117 -34 -52 -88 104 -85 59 138 -227 75 296 -178 261 164 161 108 -95 -51 -112 -202 66 -81 -198 -14 -80 110 107 -122 41 -22 -485 89 121 -210 11 198 203 49 44 52 -112 111 22 248 -162 411 87 93 341 -113 150 -270 -144 -124 99 -226 22 217 -301 -47 -149 -111 -280 201 -89 -342 135 -35 108 -38 -117 137 -306 43 -282 -120 111 28 -72 -114 146 114 5 27 -147 133 131 -121 -252 -93 -122 -174 234 112 -54 194 81 -48 259 -102 -158 -154 -311 193 192 63 166 67 -229 -29 -166 -30 231 -6 -85 128 -119 43 151 70 -121 71 -127 -37 -83 38 83 -9 119 -107 190 93 -201 66 -6 64 315 75 87 209 -176 -298 15 -162 -45 74 156 215 41 -139 -171 166 -741 67 -86 -314 235 23 -24 900000 49 -5 242 264 7 -11 10 162 219 -367 -121 -84 209 -23 -188 -41 0 233 26 -382 -103 -165 14 -154 -49 92 -74 -137 148 215 -120 39 217 167 -39 -80 -109 83 66 210 363 41 -205 -43 144 70 -121 224 -205 42 -284 -91 23 -336 -97 117 -297 188 -86 -316 -100 -190 80 179 -155 -139 -62 -165 -111 117 210 -24 102 89 308 136 63 153 -59 321 130 36 -71 -252 -282 -195 163 12 14 89 -101 158 -194 123 7 241 -76 134 122 -76 92 54 109 133 -86 -148 -22 111 -34 -53 -88 101 -81 58 140 -236 79 312 -187 266 163 160 110 -100 -55 -126 -228 74 -89 -212 -15 -83 115 113 -127 42 -23 -491 93 132 -234 12 216 218 52 48 57 -126 125 25 273 -177 442 92 91 311 -99 131 -246 -140 -127 106 -248 24 240 -335 -52 -162 -117 -285 204 -93 -365 147 -39 121 -43 -132 151 -323 43 -282 -123 118 30 -79 -123 158 125 6 29 -155 136 134 -126 -262 -99 -133 -197 276 136 -66 232 96 -57 297 -116 -173 -166 -339 217 223 74 192 75 -242 -30 -167 -31 252 -7 -98 149 -139 50 180 84 -146 85 -153 -44 -101 47 101 -10 145 -128 223 107 -230 75 -7 74 369 88 99 226 -181 -293 14 -159 -45 77 168 233 43 -141 -161 149 -650 57 -75 -282 221 24 -26 900000 SS 20231223T204926.1Z 8757.867663 356 1 50.17 2 67.02 200.65 96.37 55.84 0.00 1 0.00 1 0 33 1.308e-03 1.240e-03 1.548e-04 1.420e-04 8.400709e-07 4.683370e-08 6.917293e-08 3.509593e-07 4.148971e-07 222.45 -2.00 3.47 -2.00 340.57 0.00e+00 -7.281214e-05 1.290580e-05 1.471958e-05 9.315912e-06 1.141723e-04 268.11 -2.00 20.00 -2.00 338.10 0.00e+00 5.103059e-05 1.911036e-06 1.576255e-06 2.347649e-05 1.953780e-05 268.11 -2.00 20.00 -2.00 346.64 0.00e+00 1.643513e-04 5.489645e-06 1.668780e-05 8.851308e-06 5.467670e-05 268.11 -2.00 20.00 -2.00 345.28 0.00e+00 1.533031e+05 1.153230e+04 3.957733e+04 1.799805e+05 1.049834e+05 251.26 -2.00 11.21 -2.00 351.91 0.00e+00 3.937881e-01 1.917528e-04 3.302313e-03 1.173706e-03 1.451363e-03 222.45 -2.00 3.47 -2.00 330.76 0.00e+00 -2.014717e-03 2.212244e-04 4.224942e-04 6.713794e-05 1.347210e-03 268.11 -2.00 20.00 -2.00 328.87 0.00e+00 2.543 0.000 319.50 362.20 4 1.9141e+00 1.8372e-04 1.5012e-02 1.3357e-03 1.7579e-03 -1.6298e-02 4.7263e-05 2.3913e-03 2.3513e-04 4.1890e-04 4.6462e-04 9.1170e-05 5.5718e-04 7.5912e-05 8.3095e-04 -1.0058e-03 4.5114e-05 5.3410e-04 1.9191e-05 3.2344e-04 7.6557e-04 7.2153e-05 3.5544e-04 5.4493e-05 6.0213e-04 3.0498e-02 -1.7634e-03 1.1199e-04 2.7130e-04 5.8348e-05 9.7045e-04 -1.7337e-05 1.9497e-06 3.5843e-06 4.7019e-07 1.8492e-05 2.7606e-02 -1.2001e-04 1.3938e+00 1.1951e-02 2.3179e-02 3.3047e-03 1.0662e-01 12 8 8 10 0 0 84.01 19.03 0.21 0.02761 0.02739 657 129 1 5 0 76.350 24.65 20.00 19.03 13.28 9.1 813.22 -245 -266 384 99 -12 67 44 28 -2 -28 94 -10 242 -6 -327 -50 -10 173 127 -244 -8 -165 172 44 -9 108 -77 87 107 51 24 -140 55 135 170 -21 -197 -143 101 91 217 98 -249 28 63 74 3 133 -127 -73 -10 -238 35 -362 -203 83 -144 213 -13 -226 -15 10 -57 77 -51 -88 6 7 -26 -31 286 -53 140 -13 44 190 11 73 -195 117 73 143 -21 -143 -26 -169 115 -246 61 98 -187 68 -87 86 69 86 -54 -51 67 -6 132 23 97 113 -16 -32 21 30 14 -47 -113 190 -61 15 188 -244 163 111 -63 157 87 44 9 -85 -109 -130 -155 -50 -40 -63 -6 -10 125 158 -33 142 16 -92 76 17 -74 -5 85 13 -68 123 19 13 -100 52 44 -73 318 57 28 359 -140 118 -115 -21 -14 73 -130 -40 112 -97 115 -10 -59 -79 44 -6 -234 77 -175 8 50 -106 188 -215 14 -66 -131 43 -34 -102 -122 54 52 -73 110 -61 33 118 -102 -169 94 -161 -146 96 -142 -71 8 17 -105 167 50 -190 78 -121 15 20 48 180 102 112 -104 -93 31 -40 73 -39 171 -72 -22 68 24 -115 35 -72 -79 28 -129 49 54 83 38 36 143 -61 64 -40 19 277 11 -10 304 -100 -161 102 -191 -98 23 171 105 245 -50 -126 127 -563 -96 -210 -395 82 122 -14 900000 -115 -120 170 47 -6 36 25 16 -1 -17 59 -6 153 -4 -205 -31 -6 100 75 -153 -5 -117 126 34 -7 87 -63 70 87 42 20 -119 46 108 135 -17 -156 -114 78 69 165 77 -197 22 51 61 3 123 -119 -70 -10 -234 34 -349 -198 77 -129 184 -11 -195 -13 8 -49 66 -44 -79 6 7 -24 -28 263 -50 129 -12 40 181 10 67 -179 101 65 123 -19 -135 -24 -167 116 -249 59 93 -182 67 -91 91 71 83 -47 -41 54 -5 123 22 91 97 -14 -27 18 28 14 -47 -113 180 -57 15 186 -256 173 115 -67 158 85 44 9 -88 -121 -146 -175 -55 -45 -68 -6 -10 133 164 -34 146 16 -93 79 19 -83 -5 92 14 -74 137 22 16 -116 58 49 -80 339 60 28 329 -120 100 -106 -20 -15 77 -144 -46 127 -111 130 -11 -63 -80 45 -6 -252 86 -195 10 58 -123 207 -228 14 -66 -138 47 -38 -113 -133 59 57 -82 120 -66 34 120 -107 -179 102 -180 -170 116 -176 -88 10 21 -127 195 59 -213 87 -133 17 24 57 218 119 123 -106 -96 33 -44 86 -46 204 -87 -27 83 31 -144 44 -91 -100 35 -163 62 69 105 47 45 170 -72 76 -48 23 334 14 -11 338 -105 -162 100 -193 -99 24 187 118 272 -53 -122 116 -493 -85 -184 -365 80 129 -16 900000 SS 20231223T205933.1Z 8757.874688 363 1 18.36 2 67.74 203.05 94.80 57.49 0.00 1 0.00 1 0 33 1.508e-03 1.441e-03 8.005e-04 7.454e-04 3.695739e-07 2.440468e-07 7.457374e-08 3.509692e-07 4.777819e-07 222.45 -2.00 3.47 -2.00 340.32 0.00e+00 -3.668502e-05 6.704956e-05 1.728007e-05 9.301545e-06 1.310615e-04 268.11 -2.00 20.00 -2.00 337.81 0.00e+00 7.641055e-06 1.010164e-05 1.743293e-06 2.347597e-05 2.257786e-05 268.11 -2.00 20.00 -2.00 346.41 0.00e+00 2.119460e-04 2.882387e-05 1.783805e-05 8.870090e-06 6.297564e-05 268.11 -2.00 20.00 -2.00 345.04 0.00e+00 3.148512e+05 6.005764e+04 4.227498e+04 1.800229e+05 1.204220e+05 251.26 -2.00 11.21 -2.00 351.82 0.00e+00 4.029808e-01 9.840930e-04 3.344177e-03 1.173729e-03 1.674200e-03 222.45 -2.00 3.47 -2.00 330.56 0.00e+00 -2.385526e-03 1.118396e-03 4.490940e-04 6.511154e-05 1.545679e-03 268.11 -2.00 20.00 -2.00 328.63 0.00e+00 2.618 0.000 319.50 362.20 4 4.2215e+00 9.6113e-04 1.5460e-02 1.3356e-03 2.0258e-03 1.1978e-02 2.4283e-04 2.4611e-03 2.3509e-04 4.7905e-04 -7.4254e-04 4.7472e-04 5.6171e-04 7.4285e-05 9.5444e-04 -8.7330e-04 2.3039e-04 5.4952e-04 1.9158e-05 3.7086e-04 8.0899e-04 3.7233e-04 3.7455e-04 5.2985e-05 6.8882e-04 2.8851e-03 -2.0432e-03 5.8740e-04 2.7874e-04 5.9176e-05 1.1346e-03 5.6548e-05 1.0217e-05 3.8610e-06 4.6170e-07 2.1308e-05 2.5186e-02 -1.5467e-05 1.1855e+00 6.2371e-02 2.4580e-02 3.2913e-03 1.2272e-01 12 9 9 12 1 1 99.93 19.20 0.16 0.02519 0.02588 24 13 1 5 0 734.350 24.86 20.00 19.20 13.93 8.9 813.46 -185 -146 105 -232 -340 52 105 155 -82 -187 164 34 288 149 -126 44 257 338 -163 -184 -11 -173 214 102 1 -45 33 -14 112 103 62 -75 154 90 90 55 -62 -100 -50 59 350 -128 -282 -68 -19 143 -114 77 -173 -209 -33 -208 81 -475 -213 83 79 163 -63 -202 -115 -90 -135 159 -36 26 -16 -69 20 -101 400 4 99 -39 -10 161 -19 276 -198 255 107 -36 140 -155 -46 -183 142 -235 91 64 -250 -11 -148 160 145 207 42 -76 -39 -171 72 100 117 208 69 15 -35 118 123 44 -141 119 -131 -4 114 -161 118 128 25 99 154 109 -27 -145 -152 -147 -124 -73 -52 -106 -84 -32 100 296 -49 88 -14 -104 91 32 -49 86 45 65 -80 79 41 -103 -113 8 55 -188 394 102 72 434 -218 35 -220 -70 69 38 -165 16 50 -90 113 -62 -31 8 -8 -48 -334 147 -106 124 -20 -36 105 -234 -22 -47 -229 30 -16 -23 -135 155 8 -80 2 34 89 125 -16 -54 98 -173 -215 109 -209 -76 -127 19 -95 72 -79 -88 109 -87 19 20 74 188 160 -35 63 -7 221 108 63 -59 143 -37 18 81 11 -87 72 -131 -139 8 -97 145 -10 114 -37 58 183 -54 60 -122 31 348 -103 -73 193 -283 -179 189 -102 57 107 154 24 267 -114 -340 -43 -629 -53 -109 -369 197 158 98 900000 -92 -70 50 -116 -182 29 61 92 -50 -118 107 23 194 101 -84 29 161 208 -102 -119 -8 -125 162 81 1 -37 28 -11 93 87 53 -64 129 74 74 46 -51 -80 -39 46 273 -102 -227 -54 -15 120 -101 71 -166 -203 -32 -204 80 -473 -209 79 73 142 -54 -176 -101 -80 -120 141 -32 24 -15 -65 19 -94 370 3 94 -37 -10 152 -18 260 -183 227 95 -32 128 -146 -45 -181 142 -235 89 62 -245 -11 -154 169 150 202 37 -64 -33 -153 68 97 109 184 59 12 -31 111 122 45 -141 114 -125 -4 114 -167 123 135 26 101 153 107 -27 -153 -167 -166 -140 -82 -57 -113 -88 -33 104 311 -51 90 -15 -105 95 35 -55 96 49 70 -86 86 45 -117 -128 9 61 -207 427 108 71 393 -190 30 -200 -67 71 41 -183 18 56 -101 126 -68 -33 8 -8 -50 -360 161 -119 140 -23 -41 117 -249 -23 -47 -237 32 -17 -25 -148 169 9 -89 3 36 92 129 -17 -56 104 -191 -247 131 -257 -93 -155 23 -113 84 -90 -98 119 -96 22 23 89 222 181 -37 64 -7 231 119 72 -69 169 -44 21 99 14 -106 89 -161 -171 10 -121 181 -12 141 -46 69 214 -63 70 -143 36 414 -123 -84 211 -296 -179 186 -102 58 113 169 27 289 -117 -326 -39 -554 -46 -96 -334 187 163 108 900000 SS 20231223T210819.2Z 8757.880777 369 1 50.13 2 68.41 205.09 93.43 58.90 0.00 1 0.00 1 0 33 1.218e-03 1.153e-03 2.472e-04 2.232e-04 5.748676e-07 7.398581e-08 7.288916e-08 3.509560e-07 3.861579e-07 222.45 -2.00 3.47 -2.00 340.83 0.00e+00 4.044206e-05 2.043102e-05 1.656369e-05 9.328093e-06 1.063207e-04 268.11 -2.00 20.00 -2.00 338.42 0.00e+00 -7.001620e-06 2.994466e-06 1.698684e-06 2.347686e-05 1.815578e-05 268.11 -2.00 20.00 -2.00 346.84 0.00e+00 2.578712e-04 8.591969e-06 1.875965e-05 8.839879e-06 5.092567e-05 268.11 -2.00 20.00 -2.00 345.50 0.00e+00 3.971396e+05 1.825957e+04 4.164361e+04 1.799492e+05 9.801286e+04 251.26 -2.00 11.21 -2.00 351.95 0.00e+00 4.142081e-01 3.113282e-04 3.451166e-03 1.173846e-03 1.367275e-03 222.45 -2.00 3.47 -2.00 330.95 0.00e+00 -3.934898e-03 3.610723e-04 1.000775e-03 6.683608e-05 1.251970e-03 268.11 -2.00 20.00 -2.00 329.09 0.00e+00 2.695 0.000 319.50 362.20 4 2.6904e+00 2.8771e-04 1.5913e-02 1.3358e-03 1.6236e-03 -1.7777e-02 7.5371e-05 2.5336e-03 2.3511e-04 3.9108e-04 1.5585e-03 1.4446e-04 5.9584e-04 7.6822e-05 7.7524e-04 -6.9174e-04 7.2984e-05 5.6677e-04 1.9197e-05 3.0083e-04 -3.1942e-05 1.1529e-04 3.7236e-04 5.5376e-05 5.6192e-04 1.2761e-02 2.0218e-03 1.7643e-04 2.7298e-04 5.6717e-05 8.7990e-04 -1.5080e-05 3.0608e-06 3.6903e-06 4.7064e-07 1.7214e-05 2.4944e-02 -6.8284e-05 1.2340e+00 1.8700e-02 2.3283e-02 3.2324e-03 9.7743e-02 12 8 8 10 0 0 98.93 19.31 0.15 0.02494 0.02476 317 62 1 5 0 158.110 24.96 19.99 19.31 13.46 9.0 812.24 -114 -445 151 -44 -179 -26 -13 71 -113 25 140 43 304 144 -238 -117 49 115 67 -271 -76 -65 155 133 46 152 -25 67 153 -3 -8 -137 108 146 163 -17 -180 -88 94 127 194 54 -215 34 58 -4 -76 40 -36 -105 -43 -222 -20 -360 -192 141 -51 174 13 -255 44 30 -19 54 -53 -93 -18 37 -30 5 194 -45 88 -18 24 122 62 90 -201 48 44 105 17 -41 -15 -90 119 -168 47 86 -199 55 -67 59 102 94 -46 -104 -92 9 77 71 84 122 -69 -117 15 19 27 -25 -68 170 -59 4 195 -168 158 156 -50 117 63 23 -15 -115 -129 -176 -188 -87 -66 -78 -38 17 69 194 -57 184 75 -19 132 26 -46 32 90 62 -54 99 -64 -70 -126 38 9 -118 278 34 106 299 -189 39 -61 -18 8 116 -143 -33 72 -59 94 42 -28 -76 88 -6 -131 62 -149 -37 2 -73 157 -122 27 41 -84 61 -37 -103 -105 43 98 -67 92 -36 52 147 -24 -90 113 -119 -150 54 -206 -132 -53 -99 -126 106 72 -165 70 -52 36 11 -1 139 85 116 -54 -68 110 27 108 -40 175 -67 -36 105 33 -133 48 -44 -113 -1 -137 14 27 31 31 -1 135 -37 58 -20 -19 241 -30 -18 303 -50 -119 87 -153 -88 60 167 61 241 -50 -126 76 -485 -122 -207 -325 53 176 -7 900000 -50 -187 63 -20 -84 -13 -7 39 -61 14 85 27 192 91 -149 -70 28 66 37 -161 -49 -44 108 100 35 118 -20 52 119 -2 -7 -112 86 113 124 -13 -143 -67 69 92 141 40 -164 26 46 -3 -65 36 -33 -99 -41 -213 -19 -352 -183 127 -45 147 10 -213 37 25 -16 47 -45 -81 -16 34 -28 5 174 -41 83 -17 23 114 58 84 -181 43 38 92 15 -38 -14 -87 118 -167 45 80 -191 56 -69 62 104 90 -39 -83 -73 8 71 67 78 108 -56 -95 13 18 27 -25 -68 160 -54 4 192 -175 166 167 -53 117 63 23 -15 -123 -143 -197 -212 -96 -74 -84 -39 18 73 201 -61 188 74 -19 135 29 -52 36 98 68 -59 110 -72 -81 -146 44 10 -129 308 36 103 274 -161 33 -56 -17 8 127 -160 -37 83 -67 107 47 -30 -77 89 -7 -141 70 -167 -42 3 -85 175 -131 28 41 -89 67 -41 -115 -115 47 110 -76 102 -40 53 152 -26 -96 124 -134 -176 67 -261 -166 -66 -121 -155 126 83 -188 76 -58 41 13 -1 166 98 125 -56 -71 118 31 129 -48 213 -83 -44 131 43 -171 61 -55 -143 -2 -177 18 35 40 40 -1 164 -45 70 -25 -24 298 -37 -22 345 -54 -122 87 -157 -91 64 186 70 266 -52 -125 70 -432 -107 -186 -295 51 184 -9 900000