File name: Pandora154s1_SaltLakeCityUT_20240717_L2Fit_ffuh5c7d20220523p1-8.txt File generation date: 20241003T084658.9Z Data description: Level 2 spectral fitting results file Data file version: ffuh5c7p1-8 Local principal investigator: Jeffrey Geddes Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 154 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora154_OF_v3d20220401.txt Instrument calibration file used: Pandora154s1_CF_v7d20220523.txt Level 1 file used: Pandora154s1_SaltLakeCityUT_20240717_L1_smca1c7d20220523p1-8.txt Full location name: University of Utah, William Browning Building Short location name: SaltLakeCityUT Country of location: United States Location latitude [deg]: 40.7663 Location longitude [deg]: -111.8478 Location altitude [m]: 1455 Local noon date: 20240717 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 402 623 Nominal wavelengths inside fitting window [nm]: 328.5030 328.6419 328.7808 328.9197 329.0586 329.1975 329.3363 329.4752 329.6140 329.7528 329.8917 330.0305 330.1692 330.3080 330.4468 330.5855 330.7243 330.8630 331.0017 331.1405 331.2792 331.4178 331.5565 331.6952 331.8338 331.9725 332.1111 332.2497 332.3883 332.5269 332.6655 332.8041 332.9426 333.0812 333.2197 333.3582 333.4967 333.6352 333.7737 333.9122 334.0506 334.1891 334.3275 334.4660 334.6044 334.7428 334.8812 335.0196 335.1579 335.2963 335.4346 335.5730 335.7113 335.8496 335.9879 336.1262 336.2644 336.4027 336.5409 336.6792 336.8174 336.9556 337.0938 337.2320 337.3702 337.5084 337.6465 337.7847 337.9228 338.0609 338.1990 338.3371 338.4752 338.6133 338.7513 338.8894 339.0274 339.1654 339.3034 339.4414 339.5794 339.7174 339.8554 339.9933 340.1312 340.2692 340.4071 340.5450 340.6829 340.8208 340.9586 341.0965 341.2343 341.3721 341.5100 341.6478 341.7856 341.9233 342.0611 342.1989 342.3366 342.4744 342.6121 342.7498 342.8875 343.0252 343.1628 343.3005 343.4381 343.5758 343.7134 343.8510 343.9886 344.1262 344.2638 344.4013 344.5389 344.6764 344.8140 344.9515 345.0890 345.2265 345.3639 345.5014 345.6389 345.7763 345.9137 346.0511 346.1886 346.3259 346.4633 346.6007 346.7380 346.8754 347.0127 347.1500 347.2873 347.4246 347.5619 347.6992 347.8364 347.9737 348.1109 348.2481 348.3853 348.5225 348.6597 348.7969 348.9341 349.0712 349.2083 349.3455 349.4826 349.6197 349.7567 349.8938 350.0309 350.1679 350.3050 350.4420 350.5790 350.7160 350.8530 350.9899 351.1269 351.2638 351.4008 351.5377 351.6746 351.8115 351.9484 352.0853 352.2221 352.3590 352.4958 352.6326 352.7694 352.9062 353.0430 353.1798 353.3166 353.4533 353.5900 353.7268 353.8635 354.0002 354.1368 354.2735 354.4102 354.5468 354.6835 354.8201 354.9567 355.0933 355.2299 355.3664 355.5030 355.6396 355.7761 355.9126 356.0491 356.1856 356.3221 356.4586 356.5950 356.7315 356.8679 357.0043 357.1407 357.2771 357.4135 357.5499 357.6862 357.8226 357.9589 358.0952 358.2315 358.3678 358.5041 358.6404 358.7766 358.9129 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Formaldehyde effective temperature [K] Column 28: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 45: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Oxygen dimer effective temperature [K] Column 50: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Ozone effective temperature [K] Column 61: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Fitted Ring spectrum, -9e99=no fitting done or fitting not successful Column 67: Independent uncertainty of fitted Ring spectrum, -9=fitting not successful Column 68: Structured uncertainty of fitted Ring spectrum, -9=fitting not successful Column 69: Common uncertainty of fitted Ring spectrum, -9=fitting not successful Column 70: rms-based uncertainty of fitted Ring spectrum, -9=fitting not successful Column 71: Effective Ring fitting wavelength [nm], -9=fitting not done or not successful Column 72: Diffuse correction applied before fitting at effective Ring fitting wavelength [%], 0=no diffuse correction applied, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 73: Lower limit used for wavelength scaling [nm] Column 74: Upper limit used for wavelength scaling [nm] Column 75: Order of smoothing polynomial Column 76: Smoothing polynomial coefficient, order 0 Column 77: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 78: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 79: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 80: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 81: Smoothing polynomial coefficient, order 1 Column 82: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 83: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 84: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 85: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 86: Smoothing polynomial coefficient, order 2 Column 87: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 88: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 89: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 90: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 91: Smoothing polynomial coefficient, order 3 Column 92: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 93: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 94: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 95: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 96: Smoothing polynomial coefficient, order 4 Column 97: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 98: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 99: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 100: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 101: Mean value of measured data inside fitting window [same units as measurements] Column 102: Offset polynomial coefficient, order 0 Column 103: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 104: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 105: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 106: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 107: Offset polynomial coefficient, order 1 Column 108: Independent uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 109: Structured uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 110: Common uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 111: rms-based uncertainty of offset polynomial coefficient, order 1, -9=fitting not successful Column 112: Wavelength change polynomial coefficient, order 0 Column 113: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 114: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 115: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 116: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 117: Wavelength change polynomial coefficient, order 1 Column 118: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 119: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 120: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 121: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 122: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 123: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 124: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 125: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 126: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 127: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 128: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 129: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 130: Atmospheric variability [%], 999=no atmospheric variability was determined Column 131: Wavelength effective temperature [°C], 999=no effective temperature given Column 132: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 133: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 134: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 135: Number of bright count cycles Column 136: Number of dark count cycles Column 137: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 138: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 139: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 140: Integration time [ms] Column 141: Temperature at electronics board [°C], 999=no temperature signal Column 142: Spectrometer control temperature [°C], 999=no temperature signal Column 143: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 144: Temperature in head sensor [°C], 999=no temperature signal Column 145: Humidity in head sensor [%], -9=no humidity signal Column 146: Pressure in head sensor [hPa], -9=no pressure signal Columns 147-368: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 369-590: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------