File name: Pandora309s1_Sodankyla_20260712_L2Fit_fout2c4d20260323p1-8.txt File generation date: 20260712T222951.4Z Data description: Level 2 spectral fitting results file Data file version: fout2c4p1-8 Local principal investigator: Kaisa Lakkala Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 309 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora309_OF_v4d20250908.txt Instrument calibration file used: Pandora309s1_CF_v4d20260323.txt Level 1 file used: Pandora309s1_Sodankyla_20260712_L1_smca1c4d20260323p1-8.txt Full location name: Sodankyla Short location name: Sodankyla Country of location: Finland Location latitude [deg]: 67.3686 Location longitude [deg]: 26.6337 Location altitude [m]: 179 Local noon date: 20260712 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 196 338 Nominal wavelengths inside fitting window [nm]: 305.0993 305.2401 305.3809 305.5216 305.6624 305.8031 305.9438 306.0845 306.2252 306.3659 306.5066 306.6472 306.7879 306.9285 307.0691 307.2098 307.3504 307.4910 307.6316 307.7721 307.9127 308.0532 308.1938 308.3343 308.4748 308.6153 308.7558 308.8963 309.0368 309.1772 309.3177 309.4581 309.5986 309.7390 309.8794 310.0198 310.1602 310.3005 310.4409 310.5812 310.7216 310.8619 311.0022 311.1425 311.2828 311.4231 311.5634 311.7036 311.8439 311.9841 312.1243 312.2645 312.4047 312.5449 312.6851 312.8253 312.9654 313.1056 313.2457 313.3858 313.5259 313.6660 313.8061 313.9462 314.0863 314.2263 314.3664 314.5064 314.6464 314.7864 314.9264 315.0664 315.2064 315.3463 315.4863 315.6262 315.7662 315.9061 316.0460 316.1859 316.3258 316.4656 316.6055 316.7453 316.8852 317.0250 317.1648 317.3046 317.4444 317.5842 317.7240 317.8637 318.0035 318.1432 318.2829 318.4226 318.5623 318.7020 318.8417 318.9814 319.1210 319.2607 319.4003 319.5399 319.6795 319.8191 319.9587 320.0983 320.2378 320.3774 320.5169 320.6565 320.7960 320.9355 321.0750 321.2144 321.3539 321.4934 321.6328 321.7723 321.9117 322.0511 322.1905 322.3299 322.4693 322.6086 322.7480 322.8873 323.0267 323.1660 323.3053 323.4446 323.5839 323.7231 323.8624 324.0016 324.1409 324.2801 324.4193 324.5585 324.6977 324.8369 324.9761 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Temperature at electronics board [°C], 999=no temperature signal Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Humidity in head sensor [%], -9=no humidity signal Column 99: Pressure in head sensor [hPa], -9=no pressure signal Column 100: Humidity inside spectrometer box [%], -9=no humidity signal Column 101: Temperature inside spectrometer box [°C], 999=no temperature signal Column 102: Pressure inside spectrometer box [hPa], -9=no pressure signal Columns 103-245: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 246-388: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------