File name: Pandora192s1_Tokyo-Sophia_20240927_L2Fit_fnvs4c5d20240824p1-8.txt File generation date: 20250716T125842.3Z Data description: Level 2 spectral fitting results file Data file version: fnvs4c5p1-8 Local principal investigator: Satoshi Inomata Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 192 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora192_OF_v3d20210309.txt Instrument calibration file used: Pandora192s1_CF_v5d20240824.txt Level 1 file used: Pandora192s1_Tokyo-Sophia_20240927_L1_smca1c5d20240824p1-8.txt Full location name: Sophia University Short location name: Tokyo-Sophia Country of location: Japan Location latitude [deg]: 35.6831 Location longitude [deg]: 139.7317 Location altitude [m]: 45 Local noon date: 20240927 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 892 1435 Nominal wavelengths inside fitting window [nm]: 400.0579 400.1905 400.3232 400.4559 400.5885 400.7212 400.8538 400.9864 401.1190 401.2516 401.3841 401.5167 401.6492 401.7817 401.9143 402.0468 402.1792 402.3117 402.4442 402.5766 402.7090 402.8414 402.9738 403.1062 403.2386 403.3709 403.5033 403.6356 403.7679 403.9002 404.0325 404.1648 404.2971 404.4293 404.5615 404.6937 404.8259 404.9581 405.0903 405.2225 405.3546 405.4868 405.6189 405.7510 405.8831 406.0151 406.1472 406.2793 406.4113 406.5433 406.6753 406.8073 406.9393 407.0713 407.2032 407.3351 407.4671 407.5990 407.7309 407.8627 407.9946 408.1265 408.2583 408.3901 408.5219 408.6537 408.7855 408.9173 409.0490 409.1808 409.3125 409.4442 409.5759 409.7076 409.8393 409.9709 410.1025 410.2342 410.3658 410.4974 410.6290 410.7605 410.8921 411.0236 411.1552 411.2867 411.4182 411.5497 411.6811 411.8126 411.9440 412.0754 412.2069 412.3383 412.4696 412.6010 412.7324 412.8637 412.9950 413.1264 413.2576 413.3889 413.5202 413.6515 413.7827 413.9139 414.0451 414.1763 414.3075 414.4387 414.5699 414.7010 414.8321 414.9632 415.0943 415.2254 415.3565 415.4875 415.6186 415.7496 415.8806 416.0116 416.1426 416.2736 416.4045 416.5355 416.6664 416.7973 416.9282 417.0591 417.1900 417.3208 417.4517 417.5825 417.7133 417.8441 417.9749 418.1056 418.2364 418.3671 418.4979 418.6286 418.7593 418.8900 419.0206 419.1513 419.2819 419.4125 419.5432 419.6737 419.8043 419.9349 420.0654 420.1960 420.3265 420.4570 420.5875 420.7180 420.8485 420.9789 421.1093 421.2398 421.3702 421.5006 421.6309 421.7613 421.8917 422.0220 422.1523 422.2826 422.4129 422.5432 422.6734 422.8037 422.9339 423.0641 423.1943 423.3245 423.4547 423.5849 423.7150 423.8451 423.9753 424.1054 424.2354 424.3655 424.4956 424.6256 424.7556 424.8857 425.0157 425.1456 425.2756 425.4056 425.5355 425.6654 425.7953 425.9252 426.0551 426.1850 426.3148 426.4447 426.5745 426.7043 426.8341 426.9639 427.0937 427.2234 427.3531 427.4829 427.6126 427.7423 427.8719 428.0016 428.1312 428.2609 428.3905 428.5201 428.6497 428.7793 428.9088 429.0384 429.1679 429.2974 429.4269 429.5564 429.6859 429.8153 429.9448 430.0742 430.2036 430.3330 430.4624 430.5917 430.7211 430.8504 430.9798 431.1091 431.2384 431.3676 431.4969 431.6261 431.7554 431.8846 432.0138 432.1430 432.2722 432.4013 432.5305 432.6596 432.7887 432.9178 433.0469 433.1760 433.3050 433.4341 433.5631 433.6921 433.8211 433.9501 434.0791 434.2080 434.3369 434.4659 434.5948 434.7237 434.8525 434.9814 435.1103 435.2391 435.3679 435.4967 435.6255 435.7543 435.8830 436.0118 436.1405 436.2692 436.3979 436.5266 436.6553 436.7839 436.9125 437.0412 437.1698 437.2984 437.4270 437.5555 437.6841 437.8126 437.9411 438.0696 438.1981 438.3266 438.4550 438.5835 438.7119 438.8403 438.9687 439.0971 439.2255 439.3538 439.4822 439.6105 439.7388 439.8671 439.9954 440.1236 440.2519 440.3801 440.5083 440.6365 440.7647 440.8929 441.0210 441.1492 441.2773 441.4054 441.5335 441.6616 441.7897 441.9177 442.0458 442.1738 442.3018 442.4298 442.5578 442.6857 442.8137 442.9416 443.0695 443.1974 443.3253 443.4532 443.5810 443.7089 443.8367 443.9645 444.0923 444.2201 444.3478 444.4756 444.6033 444.7310 444.8587 444.9864 445.1141 445.2418 445.3694 445.4970 445.6246 445.7522 445.8798 446.0074 446.1349 446.2625 446.3900 446.5175 446.6450 446.7725 446.8999 447.0274 447.1548 447.2822 447.4096 447.5370 447.6644 447.7917 447.9191 448.0464 448.1737 448.3010 448.4283 448.5555 448.6828 448.8100 448.9372 449.0644 449.1916 449.3188 449.4459 449.5731 449.7002 449.8273 449.9544 450.0815 450.2085 450.3356 450.4626 450.5896 450.7166 450.8436 450.9706 451.0975 451.2245 451.3514 451.4783 451.6052 451.7321 451.8589 451.9858 452.1126 452.2394 452.3662 452.4930 452.6198 452.7465 452.8733 453.0000 453.1267 453.2534 453.3801 453.5067 453.6334 453.7600 453.8866 454.0132 454.1398 454.2664 454.3930 454.5195 454.6460 454.7725 454.8990 455.0255 455.1520 455.2784 455.4048 455.5312 455.6576 455.7840 455.9104 456.0368 456.1631 456.2894 456.4157 456.5420 456.6683 456.7945 456.9208 457.0470 457.1732 457.2994 457.4256 457.5518 457.6779 457.8041 457.9302 458.0563 458.1824 458.3085 458.4345 458.5606 458.6866 458.8126 458.9386 459.0646 459.1905 459.3165 459.4424 459.5683 459.6942 459.8201 459.9460 460.0719 460.1977 460.3235 460.4493 460.5751 460.7009 460.8267 460.9524 461.0781 461.2039 461.3296 461.4552 461.5809 461.7066 461.8322 461.9578 462.0834 462.2090 462.3346 462.4602 462.5857 462.7112 462.8367 462.9622 463.0877 463.2132 463.3386 463.4641 463.5895 463.7149 463.8403 463.9656 464.0910 464.2163 464.3417 464.4670 464.5923 464.7175 464.8428 464.9680 465.0933 465.2185 465.3437 465.4689 465.5940 465.7192 465.8443 465.9694 466.0945 466.2196 466.3447 466.4698 466.5948 466.7198 466.8448 466.9698 467.0948 467.2198 467.3447 467.4696 467.5946 467.7195 467.8443 467.9692 468.0941 468.2189 468.3437 468.4685 468.5933 468.7181 468.8428 468.9676 469.0923 469.2170 469.3417 469.4664 469.5910 469.7157 469.8403 469.9649 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Molecular iodine slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of molecular iodine slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of molecular iodine slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Molecular iodine effective temperature [K] Column 39: Independent uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of molecular iodine effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective molecular iodine fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for molecular iodine [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrogen dioxide effective temperature [K] Column 50: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Oxygen dimer slant column amount [moles squared per meter to the 5th], -9e99=fitting not successful Column 56: Independent uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of oxygen dimer slant column amount [moles squared per meter to the 5th], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Oxygen dimer effective temperature [K] Column 61: Independent uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of oxygen dimer effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective oxygen dimer fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for oxygen dimer [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 76: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 77: Iodine dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 78: Independent uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 79: Structured uncertainty of iodine dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 80: Common uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: rms-based uncertainty of iodine dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 82: Iodine dioxide effective temperature [K] Column 83: Independent uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 84: Structured uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 85: Common uncertainty of iodine dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 86: Effective iodine dioxide fitting wavelength [nm], -9=fitting not successful Column 87: Diffuse correction applied before fitting at effective fitting wavelength for iodine dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 88: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 89: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 90: Lower limit used for wavelength scaling [nm] Column 91: Upper limit used for wavelength scaling [nm] Column 92: Order of smoothing polynomial Column 93: Smoothing polynomial coefficient, order 0 Column 94: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 95: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: Smoothing polynomial coefficient, order 1 Column 99: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 100: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: Smoothing polynomial coefficient, order 2 Column 104: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 105: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: Smoothing polynomial coefficient, order 3 Column 109: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 110: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: Smoothing polynomial coefficient, order 4 Column 114: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 115: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: Mean value of measured data inside fitting window [same units as measurements] Column 119: Offset polynomial coefficient, order 0 Column 120: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 121: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: Wavelength change polynomial coefficient, order 0 Column 125: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 126: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: Wavelength change polynomial coefficient, order 1 Column 130: Independent uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 131: Structured uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 132: Common uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 133: rms-based uncertainty of wavelength change polynomial coefficient, order 1, -9=fitting not successful Column 134: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 135: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 136: Resolution change polynomial coefficient, order 0 Column 137: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 138: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 139: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 140: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 141: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 142: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 143: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 144: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 145: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 146: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 147: Atmospheric variability [%], 999=no atmospheric variability was determined Column 148: Wavelength effective temperature [°C], 999=no effective temperature given Column 149: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 150: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 151: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 152: Number of bright count cycles Column 153: Number of dark count cycles Column 154: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 155: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 156: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 157: Integration time [ms] Column 158: Temperature at electronics board [°C], 999=no temperature signal Column 159: Spectrometer control temperature [°C], 999=no temperature signal Column 160: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 161: Temperature in head sensor [°C], 999=no temperature signal Column 162: Humidity in head sensor [%], -9=no humidity signal Column 163: Pressure in head sensor [hPa], -9=no pressure signal Columns 164-707: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 708-1251: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SQ 20240927T022340.0Z 9036.099768 436 1 47.72 2 37.52 176.56 50.38 273.31 0.00 1 0.00 1 0 33 2.092e-03 2.038e-03 1.149e-03 1.130e-03 9.818516e+03 2.441318e+02 8.075360e+02 3.351881e+02 4.375636e+02 289.61 -2.00 20.00 -2.00 445.19 0.00e+00 1.169110e-03 1.250937e-04 1.748230e-05 3.340390e-05 2.311615e-04 289.61 -2.00 20.00 -2.00 454.67 0.00e+00 3.512743e-04 1.255045e-05 2.752137e-05 5.388873e-05 2.335607e-05 289.61 -2.00 20.00 -2.00 434.90 0.00e+00 7.390067e+05 1.611457e+05 1.057988e+05 2.025285e+05 3.022668e+05 270.17 -2.00 10.93 -2.00 457.78 0.00e+00 1.865921e-01 3.222972e-02 8.162943e-03 8.106406e-03 6.577288e-02 228.28 -2.00 3.41 -2.00 454.03 0.00e+00 2.231544e-05 4.015475e-06 1.415818e-06 9.641573e-07 7.973736e-06 289.61 -2.00 20.00 -2.00 455.39 0.00e+00 1.260 0.000 397.00 473.00 4 7.9735e+00 1.2545e-03 3.4272e-03 5.7969e-04 2.2347e-03 4.5208e-02 1.4221e-03 6.9275e-04 4.2708e-04 2.6380e-03 -1.9772e-02 8.3593e-04 1.2082e-04 3.7576e-04 1.5391e-03 -3.4207e-03 2.7758e-04 4.5044e-05 9.1246e-05 5.1417e-04 2.4470e-03 1.4142e-04 2.7207e-05 3.1150e-05 2.5633e-04 5.1637e-04 -2.4558e-02 8.5163e-04 1.5701e-04 3.0971e-04 1.4796e-03 1.1434e-04 1.3005e-05 1.4093e-06 1.8823e-06 2.3267e-05 -1.2284e-04 1.7926e-05 2.1241e-06 1.9632e-06 3.2355e-05 3.2508e-03 8.1539e-05 9.0961e-01 1.1181e-01 1.0353e-02 2.1379e-02 1.9367e-01 12 8 8 10 0 0 51.21 16.17 0.75 0.00325 0.01620 12 3 1 4 0 3975.910 20.67 15.00 16.17 32.15 9.7 970.50 -3 -635 -68 69 -221 -190 -333 195 -167 -72 -47 -181 -312 -186 -384 21 -407 44 -100 -55 -138 -25 -244 -389 -338 305 -6 61 160 230 301 -13 -110 284 74 222 63 153 -42 205 145 -122 257 256 23 89 10 77 -32 448 -126 -69 321 400 243 -27 590 -119 174 248 276 -10 368 509 146 473 444 196 501 355 233 434 234 216 -207 147 -253 -151 -450 -263 -152 19 57 104 178 62 44 11 87 377 213 -73 249 -55 96 -129 35 -117 -331 -523 158 209 -181 190 136 38 -220 108 316 51 46 -348 -126 -83 -371 -232 -84 -259 -225 -407 -331 -505 -210 -308 -360 -83 -379 -4 -365 -96 -246 -359 -378 112 -245 -478 -75 -67 -137 18 -141 228 -56 137 -17 85 579 -125 -78 20 -170 -173 -58 77 -209 -6 287 -51 34 386 75 291 152 6 43 213 17 372 -138 -191 -280 -138 -123 -129 -99 -339 -196 -177 -261 -24 -9 -110 -50 -117 -86 171 198 -60 115 -34 66 -394 47 70 -354 -340 -331 -195 -97 107 163 -138 621 90 -59 170 -315 -125 62 -142 -600 72 -122 -106 131 71 240 -179 -77 200 45 192 621 466 257 349 438 343 509 479 270 26 -166 -25 -234 24 170 -292 26 -88 266 84 461 140 235 111 -33 176 -24 273 -271 -261 -35 10 140 -97 138 -37 -590 66 -285 -255 -69 -467 -34 -308 -207 -226 -23 -14 -169 -205 -383 3 208 88 5 -70 -134 300 365 11 172 104 -91 -207 -302 256 -217 56 -232 -301 -107 -106 332 -91 -166 159 17 -18 129 351 208 196 244 252 297 144 -25 115 -147 -89 -19 357 265 245 319 126 278 108 193 27 -250 0 -1 39 304 -38 -245 117 -83 -198 223 142 199 -51 -32 -83 382 129 180 53 201 119 17 -12 208 197 214 -110 -38 75 -422 -183 38 -177 -103 -53 -8 -28 102 -215 7 -154 -247 77 16 121 -159 55 42 -36 -144 -105 19 -135 55 -32 -120 35 -15 -62 -370 -270 -136 136 -105 21 73 -156 -182 45 -220 187 -205 207 -229 41 86 -57 273 115 229 -83 371 -31 -105 102 38 -140 -304 203 -141 -35 -93 7 -167 271 -35 164 90 -267 -326 12 94 96 -138 197 264 18 -151 20 -94 -129 28 68 -102 51 198 -187 51 105 18 120 -151 62 -241 -136 44 -2 -41 -271 60 -36 115 -92 12 211 -15 -273 -69 -148 -438 -15 82 86 89 255 171 163 -26 -79 28 -39 -107 -67 -216 -70 148 -156 59 -67 33 -147 215 14 -5 159 -63 135 166 -35 -36 -210 -177 157 -202 -220 -180 189 -121 -184 -150 -20 121 131 -29 236 -208 150 -79 209 376 281 17 -161 -310 89 -262 109 144 172 182 3 -88 8 54 93 -98 243 322 87 -45 -209 47 -171 158 -154 -19 282 -234 35 -78 -182 -2 -568 -59 58 -186 -161 -292 175 -153 -66 -43 -166 -287 -172 -355 19 -380 41 -93 -51 -130 -23 -216 -331 -294 256 -5 57 152 221 286 -12 -95 244 63 192 56 142 -39 189 130 -108 232 233 21 81 9 67 -28 389 -116 -65 298 372 225 -25 537 -108 156 227 263 -9 346 477 138 456 440 197 497 347 223 404 223 199 -181 122 -216 -129 -387 -242 -147 18 54 99 173 62 45 11 88 376 210 -72 247 -55 95 -128 34 -113 -329 -511 152 204 -176 191 141 40 -223 105 312 50 45 -344 -126 -83 -365 -225 -80 -246 -214 -396 -329 -517 -219 -323 -377 -85 -385 -4 -358 -92 -231 -349 -367 110 -235 -464 -72 -65 -132 17 -134 215 -54 130 -17 86 582 -125 -76 19 -162 -164 -55 72 -201 -6 293 -52 36 402 78 301 155 6 43 212 17 383 -140 -185 -261 -121 -108 -119 -94 -341 -199 -176 -251 -22 -9 -104 -49 -116 -87 174 199 -59 110 -32 62 -373 45 68 -348 -331 -315 -182 -90 101 161 -135 605 86 -56 152 -270 -109 55 -128 -571 70 -119 -103 126 68 226 -167 -70 175 39 168 547 419 232 303 374 273 384 349 198 20 -125 -19 -176 18 123 -226 22 -79 250 85 482 141 241 107 -31 153 -21 246 -252 -258 -36 10 143 -97 132 -35 -507 54 -234 -219 -64 -441 -33 -311 -208 -220 -22 -13 -159 -199 -382 3 211 86 5 -71 -136 301 363 10 166 104 -89 -200 -290 245 -212 54 -221 -283 -93 -92 286 -78 -151 150 17 -18 125 328 199 190 236 243 284 135 -23 107 -138 -84 -18 348 267 251 322 124 270 105 195 27 -250 0 0 39 303 -36 -237 113 -81 -189 218 139 189 -50 -32 -82 371 124 173 51 200 119 17 -12 205 188 206 -104 -35 70 -397 -173 37 -166 -99 -52 -8 -28 99 -213 7 -158 -258 81 17 123 -159 53 41 -36 -147 -109 20 -137 55 -32 -120 35 -15 -63 -382 -281 -143 144 -112 23 80 -172 -200 49 -239 200 -219 217 -240 43 90 -60 286 120 237 -84 382 -31 -103 100 38 -140 -305 204 -144 -37 -99 7 -183 293 -38 176 96 -280 -338 12 97 99 -144 206 279 19 -165 22 -105 -143 31 73 -110 55 217 -206 56 116 20 132 -168 69 -263 -145 48 -2 -44 -296 66 -40 130 -104 14 237 -16 -303 -76 -165 -487 -17 91 96 100 287 195 187 -30 -92 33 -45 -123 -78 -250 -81 170 -181 69 -79 39 -172 250 16 -5 186 -73 157 192 -40 -41 -238 -200 178 -230 -252 -204 211 -133 -210 -164 -23 136 148 -33 267 -236 172 -92 244 437 322 20 -183 -345 97 -290 122 166 194 207 3 -100 9 60 103 -109 271 362 99 -51 -238 53 -194 178 -175 -22 321 -266 39 -87 -208