File name: Pandora176s1_Tsukuba-NIES_20220908_L2Fit_fsus1c2d20210908p1-8.txt File generation date: 20241219T182601.7Z Data description: Level 2 spectral fitting results file Data file version: fsus1c2p1-8 Local principal investigator: Tamaki Fujinawa Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 176 Spectrometer number: 1 Processing software version used: BlickP v1.8.60 Instrument operation file used: Pandora176_OF_v3d20200605.txt Instrument calibration file used: Pandora176s1_CF_v2d20210908.txt Level 1 file used: Pandora176s1_Tsukuba-NIES_20220908_L1_smca1c2d20210908p1-8.txt Full location name: National Institute for Environmental Studies (NIES) Short location name: Tsukuba-NIES Country of location: Japan Location latitude [deg]: 36.0513 Location longitude [deg]: 140.1210 Location altitude [m]: 45 Local noon date: 20220908 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 263 408 Nominal wavelengths inside fitting window [nm]: 306.0091 306.1498 306.2905 306.4313 306.5720 306.7127 306.8534 306.9941 307.1347 307.2754 307.4160 307.5567 307.6973 307.8379 307.9785 308.1191 308.2597 308.4002 308.5408 308.6813 308.8218 308.9624 309.1029 309.2434 309.3838 309.5243 309.6648 309.8052 309.9457 310.0861 310.2265 310.3669 310.5073 310.6477 310.7880 310.9284 311.0687 311.2091 311.3494 311.4897 311.6300 311.7703 311.9105 312.0508 312.1910 312.3313 312.4715 312.6117 312.7519 312.8921 313.0323 313.1725 313.3126 313.4528 313.5929 313.7330 313.8731 314.0132 314.1533 314.2934 314.4334 314.5735 314.7135 314.8535 314.9935 315.1335 315.2735 315.4135 315.5535 315.6934 315.8334 315.9733 316.1132 316.2531 316.3930 316.5329 316.6728 316.8126 316.9525 317.0923 317.2322 317.3720 317.5118 317.6516 317.7913 317.9311 318.0709 318.2106 318.3503 318.4900 318.6298 318.7694 318.9091 319.0488 319.1885 319.3281 319.4677 319.6074 319.7470 319.8866 320.0262 320.1657 320.3053 320.4449 320.5844 320.7239 320.8634 321.0030 321.1424 321.2819 321.4214 321.5609 321.7003 321.8397 321.9792 322.1186 322.2580 322.3974 322.5367 322.6761 322.8154 322.9548 323.0941 323.2334 323.3727 323.5120 323.6513 323.7906 323.9298 324.0691 324.2083 324.3475 324.4867 324.6259 324.7651 324.9043 325.0434 325.1826 325.3217 325.4609 325.6000 325.7391 325.8782 326.0172 326.1563 326.2954 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220907T230700.6Z 8285.963201 222 1 7.56 2 56.78 109.13 156.72 300.18 0.00 1 0.00 1 0 33 7.185e-03 3.347e-03 7.139e-03 3.292e-03 4.120615e-08 1.250670e-06 4.583076e-08 4.181324e-07 3.369401e-06 229.90 -2.00 3.41 -2.00 321.45 0.00e+00 1.821670e-04 4.433681e-04 1.750574e-05 1.168086e-05 8.762602e-04 291.16 -2.00 20.00 -2.00 321.17 0.00e+00 1.940723e-03 6.028930e-04 1.336764e-05 2.777302e-05 1.510492e-03 291.16 -2.00 20.00 -2.00 321.39 0.00e+00 6.336043e-04 8.727689e-04 8.652153e-05 1.426495e-05 1.623935e-03 291.16 -2.00 20.00 -2.00 321.33 0.00e+00 2.333621e-01 4.587669e-03 2.590386e-04 2.320824e-03 9.057087e-03 224.34 4.71 0.00 2.16 15.57 317.50 0.00e+00 -1.426890e-04 2.490993e-04 6.661964e-05 7.461440e-06 2.354446e-04 291.16 -2.00 20.00 -2.00 316.26 0.00e+00 1.819 0.000 303.00 329.40 4 4.5899e+00 1.1956e-02 1.7627e-02 2.1403e-03 2.8538e-02 6.9390e-03 1.6640e-02 2.5311e-03 3.7265e-04 3.0663e-02 1.5958e-03 8.9934e-03 5.4301e-04 1.2430e-04 1.6865e-02 -7.5795e-03 3.7938e-03 5.8484e-05 3.7224e-05 6.5166e-03 6.7597e-03 2.6689e-03 1.0500e-04 5.6501e-05 4.3177e-03 8.8200e-04 -4.7094e-03 2.2103e-03 4.4456e-05 1.6135e-05 2.1287e-03 -5.7260e-05 9.3690e-05 1.4299e-06 8.1155e-07 2.0970e-04 -2.3692e-03 -1.7733e-05 1.0025e-01 3.1395e-01 1.8930e-03 5.8634e-04 5.9237e-01 12 9 9 12 9 1 -69.42 20.23 0.15 -0.00237 -0.00281 5 9 1 5 0 1230.490 26.73 19.99 20.23 31.14 10.4 1025.61 1622 810 1110 -4 2812 -1225 -620 -3515 -1252 156 1076 -1319 886 893 206 765 478 -1916 -1216 409 -404 773 -1094 2518 -271 746 -65 -1313 69 -495 1448 -904 849 -201 111 331 272 762 755 660 -25 -195 174 -699 -730 -1459 -203 66 138 668 -379 238 -710 131 114 123 543 -493 -535 445 -305 -39 -40 399 761 -799 -6 -115 211 -1084 348 480 69 -44 -15 423 315 -140 -30 -283 -191 -159 -19 395 207 -141 77 -582 22 158 199 296 4 -56 316 -309 -119 -404 -185 -293 128 -85 336 114 198 -124 -27 -50 -111 305 89 -80 -190 478 -294 121 -238 239 222 15 399 -162 -293 -241 92 -182 168 -394 170 -449 453 -52 131 -23 186 -306 -111 99 -157 -70 211 161 18 -107 -17 14 219 123 181 -1 452 -219 -123 -803 -308 40 279 -361 245 253 59 217 142 -612 -402 136 -130 231 -319 725 -85 247 -23 -458 23 -170 546 -401 425 -111 64 195 162 450 446 387 -15 -111 97 -402 -442 -928 -133 44 94 462 -266 164 -488 90 82 94 435 -407 -425 329 -219 -28 -31 339 673 -723 -5 -98 168 -809 244 336 52 -36 -13 397 305 -141 -32 -311 -215 -180 -21 423 209 -134 69 -540 22 166 224 351 5 -65 348 -327 -126 -451 -216 -352 158 -108 440 155 274 -169 -35 -62 -132 356 106 -100 -248 640 -396 161 -310 300 270 17 460 -193 -368 -314 122 -244 229 -556 249 -672 684 -80 199 -35 272 -442 -161 148 -246 -116 360 287 32 -197 -32 25 SS 20220907T231113.8Z 8285.966131 225 1 47.91 2 55.97 109.94 157.41 301.77 0.00 1 0.00 1 0 49 2.800e-03 9.846e-04 3.106e-03 9.974e-04 4.953046e-07 3.748246e-07 1.102331e-08 4.182724e-07 1.313892e-06 229.90 -2.00 3.41 -2.00 322.16 0.00e+00 4.665427e-04 1.407359e-04 7.578287e-06 1.201309e-05 3.424396e-04 291.15 -2.00 20.00 -2.00 322.13 0.00e+00 1.747916e-04 1.861559e-04 1.879002e-06 2.771018e-05 5.879895e-04 291.15 -2.00 20.00 -2.00 321.89 0.00e+00 -1.547453e-05 2.980678e-04 3.607155e-05 1.429385e-05 6.329228e-04 291.15 -2.00 20.00 -2.00 322.01 0.00e+00 2.308733e-01 1.558245e-03 1.276486e-04 2.320896e-03 3.516493e-03 229.22 1.62 0.00 2.22 6.02 318.69 0.00e+00 -5.608277e-05 9.998260e-05 2.707885e-06 7.614169e-06 9.169106e-05 291.15 -2.00 20.00 -2.00 317.38 0.00e+00 1.781 0.000 303.00 329.40 4 3.2501e+00 3.9109e-03 1.7245e-02 2.1411e-03 1.1078e-02 1.5824e-02 5.9195e-03 1.8530e-03 3.8285e-04 1.1897e-02 1.9599e-03 3.0983e-03 2.5405e-04 1.3940e-04 6.5658e-03 -4.7546e-03 1.3157e-03 7.3066e-05 5.1202e-05 2.5342e-03 2.0530e-03 8.8477e-04 1.8415e-05 6.4484e-05 1.6699e-03 3.5204e-03 -3.6528e-03 8.5896e-04 5.4691e-05 2.4682e-05 8.8009e-04 5.1952e-04 2.9832e-05 1.7522e-06 8.6364e-07 8.2341e-05 -2.7883e-03 1.1592e-04 5.9382e-03 1.0206e-01 1.4627e-03 5.1044e-04 2.3497e-01 11 8 0 10 0 0 99.97 20.23 0.15 -0.00279 0.00118 619 147 1 5 0 77.390 26.73 20.00 20.23 31.41 10.4 1027.77 405 -1368 858 -323 1321 -829 660 -253 136 -150 472 -320 -262 -404 -9 -12 41 189 -360 138 -562 549 109 1068 20 196 256 -189 310 -232 -21 -36 -52 -376 10 -271 176 -134 249 -329 271 -66 -8 -19 26 -100 -117 259 0 226 -125 54 -64 175 154 93 -71 -6 24 -121 -57 -231 -42 -203 132 -134 350 -196 257 111 138 -40 32 40 61 -94 -169 14 -129 59 -73 97 -73 80 -209 -13 -46 -32 -51 93 130 -60 144 -31 -92 -70 123 -113 36 -45 19 44 10 25 -36 79 -7 183 -125 72 -58 22 -76 36 -4 82 -62 -19 -34 -57 21 -103 123 -109 50 -130 25 -73 5 -11 157 5 -18 19 -94 47 -83 -66 -31 30 30 96 49 18 -54 -48 35 -137 91 -35 139 -96 85 -37 22 -26 83 -58 -49 -78 -2 -2 8 40 -80 31 -123 109 22 221 5 47 66 -47 72 -57 -6 -12 -19 -155 4 -121 79 -60 111 -146 126 -30 -4 -9 12 -52 -63 145 0 132 -74 31 -36 100 93 61 -51 -4 16 -76 -34 -139 -29 -154 106 -109 277 -148 176 68 78 -23 20 28 48 -81 -152 13 -131 63 -82 109 -81 83 -198 -11 -37 -26 -45 92 141 -72 173 -35 -97 -68 120 -121 41 -54 24 57 13 36 -53 114 -9 227 -144 80 -67 27 -101 50 -5 110 -81 -24 -40 -63 23 -116 150 -141 66 -176 35 -107 8 -17 257 9 -29 31 -145 71 -125 -104 -53 55 60 188 99 37 -112 -97 SS 20220907T231547.6Z 8285.969301 228 1 47.97 2 55.11 110.83 158.13 303.59 0.00 1 0.00 1 0 49 1.632e-03 6.307e-04 1.030e-03 4.183e-04 9.252439e-07 1.576406e-07 1.372893e-08 4.182102e-07 7.666158e-07 229.90 -2.00 3.41 -2.00 321.79 0.00e+00 1.296060e-04 5.761575e-05 5.522804e-06 1.187209e-05 2.001348e-04 291.15 -2.00 20.00 -2.00 321.65 0.00e+00 6.175957e-05 7.781586e-05 2.605594e-06 2.773301e-05 3.424794e-04 291.15 -2.00 20.00 -2.00 321.64 0.00e+00 1.856856e-04 1.163303e-04 3.329654e-05 1.424782e-05 3.689316e-04 291.15 -2.00 20.00 -2.00 321.67 0.00e+00 2.255205e-01 6.214669e-04 9.365958e-05 2.320799e-03 2.048614e-03 231.94 0.67 0.00 2.26 3.51 318.05 0.00e+00 3.025928e-05 3.539159e-05 8.096025e-06 7.495548e-06 5.342593e-05 291.15 -2.00 20.00 -2.00 316.76 0.00e+00 1.743 0.000 303.00 329.40 4 2.1977e+00 1.6596e-03 1.6874e-02 2.1409e-03 6.4605e-03 1.7873e-02 2.3617e-03 1.7913e-03 3.7536e-04 6.9375e-03 -3.9948e-03 1.2419e-03 2.2031e-04 1.2994e-04 3.8358e-03 4.4831e-04 4.9920e-04 6.9602e-05 4.1103e-05 1.4686e-03 1.1257e-04 3.4546e-04 2.8179e-05 6.0037e-05 9.6461e-04 1.0499e-02 -2.5602e-03 3.2980e-04 2.8475e-05 1.9709e-05 5.4044e-04 3.9390e-04 1.2098e-05 1.3665e-06 8.4275e-07 4.7907e-05 -3.0922e-03 6.4971e-05 -1.6877e-01 4.2206e-02 6.2480e-04 5.4078e-04 1.3850e-01 10 0 0 10 0 0 99.72 20.23 0.15 -0.00309 -0.00009 596 142 1 5 0 80.460 26.73 20.01 20.23 32.03 10.5 1032.47 264 538 -522 411 -863 476 -126 393 -475 -28 -261 -181 89 -169 125 -143 248 -352 241 -237 298 -162 143 38 261 182 45 -157 -119 -124 -77 228 -86 66 -117 139 -152 155 -57 -36 49 112 136 6 42 -61 120 -67 170 -26 122 -147 15 -43 74 1 39 5 -48 -20 -204 -18 -111 39 -24 0 -107 44 -32 8 19 -67 111 86 119 -11 18 -90 -13 -107 17 -52 -28 15 91 64 -18 20 -24 32 -56 -22 -13 57 -99 29 20 -12 -26 -32 13 -29 64 0 52 -59 95 6 71 13 17 45 33 -35 29 46 -17 53 -30 -26 4 63 -44 -9 -44 -62 -94 11 29 15 42 -6 13 -72 -14 -37 45 -123 11 -42 43 41 65 5 -43 16 31 71 -75 59 -123 72 -22 76 -102 -6 -60 -43 22 -43 31 -36 65 -98 70 -70 84 -42 35 9 69 52 14 -47 -33 -36 -26 90 -40 32 -59 72 -80 81 -29 -18 27 59 71 3 24 -34 69 -40 103 -16 76 -90 9 -26 48 1 29 4 -35 -13 -140 -13 -79 31 -20 0 -90 35 -23 5 13 -44 80 64 98 -9 17 -90 -14 -120 19 -56 -33 17 90 57 -15 17 -22 33 -64 -25 -14 68 -108 29 20 -14 -31 -40 16 -37 83 0 73 -83 124 7 85 15 21 57 41 -46 39 60 -23 68 -37 -30 5 74 -57 -13 -62 -88 -136 15 43 22 66 -9 21 -110 -20 -53 64 -186 17 -75 75 78 126 9 -85 30 SS 20220907T232102.6Z 8285.972947 231 1 48.05 2 54.12 111.88 158.95 305.81 0.00 1 0.00 1 0 49 4.902e-03 1.884e-03 4.941e-03 1.914e-03 -4.178535e-07 7.231067e-07 3.165846e-08 4.182288e-07 2.302981e-06 229.90 -2.00 3.41 -2.00 321.98 0.00e+00 3.823351e-04 2.667545e-04 1.113254e-05 1.188648e-05 6.017318e-04 291.15 -2.00 20.00 -2.00 321.92 0.00e+00 5.990196e-04 3.593560e-04 1.177907e-05 2.771791e-05 1.044211e-03 291.15 -2.00 20.00 -2.00 321.76 0.00e+00 -5.166940e-04 5.485865e-04 2.879896e-05 1.431112e-05 1.108259e-03 291.15 -2.00 20.00 -2.00 321.84 0.00e+00 2.289171e-01 2.924247e-03 1.558459e-04 2.320975e-03 6.157810e-03 232.55 3.11 0.00 2.25 10.71 318.31 0.00e+00 -1.138697e-04 1.727918e-04 2.866659e-05 7.540706e-06 1.656735e-04 291.15 -2.00 20.00 -2.00 316.99 0.00e+00 1.702 0.000 303.00 329.40 4 4.9493e+00 7.7300e-03 1.6474e-02 2.1412e-03 1.9446e-02 4.5419e-02 1.1204e-02 1.8849e-03 3.7879e-04 2.0905e-02 -7.6004e-03 5.8482e-03 2.8845e-04 1.3456e-04 1.1506e-02 -4.4462e-03 2.3656e-03 8.5087e-05 4.5321e-05 4.4135e-03 3.6324e-03 1.6307e-03 5.0639e-05 6.1484e-05 2.9148e-03 7.0021e-04 -8.7118e-03 1.6046e-03 5.0286e-05 2.3363e-05 1.8359e-03 7.4743e-04 5.6927e-05 1.8480e-06 8.4756e-07 1.4494e-04 -3.2240e-03 1.4980e-04 4.2539e-01 1.9851e-01 8.4003e-04 5.6033e-04 4.2882e-01 12 8 8 10 0 0 99.98 20.25 0.20 -0.00322 0.00248 54 13 1 5 0 889.730 26.73 20.00 20.25 32.86 10.4 1037.84 900000 -583 1358 -991 2081 46 2667 -865 -507 631 -461 -291 -521 -220 -1223 979 -424 1032 -446 -201 -1314 733 135 111 478 1014 -116 -414 55 -602 1367 -633 502 38 -88 -782 -236 398 -93 185 85 -322 -288 58 -70 295 197 -71 -379 377 185 335 -83 3 17 -8 216 -77 82 -324 -123 -520 158 -63 38 -59 296 -297 234 200 -71 60 89 180 42 260 -148 -54 -145 49 -263 237 -11 -151 -23 -93 130 -145 -65 -177 226 25 113 218 -24 -420 -39 -148 -187 -35 17 101 68 219 -17 189 -182 93 -79 98 168 -29 -293 -38 152 186 69 -299 68 -21 12 -300 71 -136 11 83 96 -242 -155 58 236 39 -145 27 2 142 -85 44 -149 -104 79 248 13 77 -19 -187 900000 -70 173 -130 262 6 402 -152 -98 127 -96 -62 -115 -50 -281 220 -101 256 -117 -53 -340 173 31 26 117 264 -33 -114 14 -164 412 -229 211 18 -43 -399 -122 203 -48 93 42 -155 -137 28 -36 159 112 -42 -227 229 114 202 -50 2 11 -6 157 -58 58 -213 -77 -331 111 -49 31 -49 241 -232 167 130 -43 36 59 133 34 227 -135 -52 -148 52 -290 263 -13 -157 -22 -82 108 -123 -60 -177 246 29 134 247 -26 -422 -39 -160 -215 -42 21 129 90 304 -25 264 -242 115 -92 111 195 -36 -385 -52 208 249 90 -373 82 -24 14 -350 88 -176 15 112 132 -349 -235 91 373 63 -232 42 4 210 -127 69 -248 -183 148 483 27 157 -39 -377 SS 20220907T232541.0Z 8285.976168 234 1 42.71 2 53.26 112.83 159.65 307.90 0.00 1 0.00 1 0 66 1.960e-02 6.947e-03 1.837e-02 6.920e-03 -6.786170e-06 2.618257e-06 1.871835e-07 4.182389e-07 9.139232e-06 229.90 -2.00 3.41 -2.00 322.06 0.00e+00 3.910516e-03 9.727681e-04 1.237536e-04 1.189974e-05 2.405500e-03 291.15 -2.00 20.00 -2.00 322.06 0.00e+00 7.400387e-04 1.304411e-03 4.259584e-05 2.770101e-05 4.174303e-03 291.15 -2.00 20.00 -2.00 321.81 0.00e+00 -9.380746e-04 2.037933e-03 7.431000e-05 1.432083e-05 4.430269e-03 291.15 -2.00 20.00 -2.00 321.91 0.00e+00 2.345131e-01 1.057185e-02 2.098549e-04 2.320966e-03 2.456117e-02 226.73 10.81 0.00 2.23 42.73 318.37 0.00e+00 -8.719539e-04 6.396386e-04 4.453649e-05 7.566056e-06 6.585142e-04 291.15 -2.00 20.00 -2.00 317.06 0.00e+00 1.667 0.000 303.00 329.40 4 6.6291e+00 2.6389e-02 1.6174e-02 2.1412e-03 7.7567e-02 1.0107e-01 3.9402e-02 2.5967e-03 3.7727e-04 8.3342e-02 8.1755e-03 2.0817e-02 1.0075e-03 1.3546e-04 4.5856e-02 -1.3145e-02 8.5468e-03 9.2729e-04 4.7131e-05 1.7341e-02 -1.3909e-03 5.9190e-03 2.8328e-04 6.1569e-05 1.1588e-02 1.3167e-04 -1.0316e-02 6.1255e-03 5.6564e-04 2.6886e-05 7.3189e-03 1.3059e-03 2.1416e-04 1.1089e-05 8.5932e-07 5.8015e-04 -3.8841e-03 2.7375e-04 2.7927e+00 7.2775e-01 1.8291e-02 5.7857e-04 1.7096e+00 12 9 9 12 1 1 99.99 20.25 0.60 -0.00388 0.00608 21 6 1 5 0 1933.670 26.73 20.00 20.25 33.26 10.3 1038.70 900000 2233 -4982 -4462 -888 13536 -8039 -77 -2527 2107 2561 2568 1439 -2619 -410 917 1765 -4099 3566 -400 2463 -1616 624 3685 512 816 -1594 -1978 -1257 2079 -4189 4126 401 1981 -651 -710 -641 -125 358 541 -1477 -987 1040 -566 642 663 642 -1601 -373 -284 1045 420 -406 -1237 1346 1621 -387 -562 -1173 115 -969 1035 -2153 1827 -1704 1318 -763 743 49 -102 297 409 754 -1185 979 -895 1692 -625 252 -1235 1254 378 137 185 -806 219 -614 -869 291 -70 -142 749 184 928 -303 -344 92 -176 -1339 -326 -308 -172 299 888 311 -315 487 -25 -288 -948 129 -192 -484 236 336 654 206 -584 -313 -314 19 200 258 -450 17 -172 192 393 81 -390 -27 -300 274 -517 206 869 733 -932 120 -631 452 121 -97 344 79 -393 900000 251 -647 -588 -113 1610 -1299 -13 -481 404 500 518 302 -588 -90 200 399 -1034 876 -104 599 -379 137 796 121 205 -436 -532 -320 539 -1301 1399 166 899 -319 -358 -328 -63 180 268 -725 -469 477 -270 322 351 357 -944 -221 -172 629 251 -241 -750 838 1080 -279 -416 -827 73 -597 635 -1515 1377 -1402 1072 -619 566 35 -65 175 240 485 -871 776 -778 1495 -593 255 -1331 1369 420 150 191 -771 190 -504 -729 262 -70 -155 873 218 1040 -320 -342 91 -188 -1539 -386 -381 -220 400 1238 447 -446 647 -30 -332 -1072 149 -234 -634 320 456 869 265 -718 -368 -353 20 227 312 -577 22 -230 263 562 123 -612 -44 -487 437 -810 312 1278 1088 -1465 200 -1133 853 242 -200 718 165 -813 SS 20220908T023057.1Z 8286.104827 352 1 10.95 2 30.35 176.85 152.82 65.56 0.00 1 0.00 1 0 49 5.729e-03 3.713e-03 5.337e-03 3.635e-03 -3.958778e-06 1.424306e-06 8.685991e-08 4.180096e-07 2.688258e-06 229.89 -2.00 3.41 -2.00 320.66 0.00e+00 2.220736e-03 4.710175e-04 5.146486e-05 1.142170e-05 7.115445e-04 291.15 -2.00 20.00 -2.00 320.24 0.00e+00 -3.007537e-04 6.789439e-04 2.362222e-05 2.771412e-05 1.208858e-03 291.15 -2.00 20.00 -2.00 320.82 0.00e+00 1.618402e-03 8.760492e-04 4.065732e-05 1.429973e-05 1.295645e-03 291.15 -2.00 20.00 -2.00 320.57 0.00e+00 1.510024e-01 4.538004e-03 1.519035e-04 2.320341e-03 7.065538e-03 216.98 7.26 0.00 3.40 12.21 315.95 0.00e+00 7.443311e-05 2.011184e-04 6.784473e-06 7.313004e-06 1.871544e-04 291.15 -2.00 20.00 -2.00 314.85 0.00e+00 1.158 0.000 303.00 329.40 4 5.7706e+00 1.2388e-02 1.1258e-02 2.1382e-03 2.2681e-02 1.2622e-02 1.5629e-02 1.2783e-03 3.4926e-04 2.4041e-02 1.9436e-02 8.8330e-03 6.1641e-04 1.0622e-04 1.3497e-02 -8.9131e-03 3.2195e-03 1.5786e-04 2.4475e-05 4.8435e-03 -4.0497e-03 2.5405e-03 1.5037e-04 4.2182e-05 3.2882e-03 5.7881e-04 -7.4402e-03 2.9358e-03 2.1996e-04 2.1738e-05 3.1416e-03 4.1677e-04 1.0334e-04 4.5642e-06 7.8652e-07 1.6832e-04 -5.1745e-03 3.5156e-05 1.0914e+00 4.1392e-01 1.3528e-02 7.6649e-04 5.7776e-01 12 9 9 12 9 1 84.45 20.25 0.26 -0.00517 -0.00199 3 4 1 5 0 2693.610 26.73 20.00 20.25 33.37 10.4 1039.23 -811 -1186 635 -316 1193 871 841 -1505 728 269 1130 -1838 327 731 -22 -269 -921 275 -1063 151 -73 1075 -1100 -290 -2485 186 -535 372 1850 968 -29 661 522 -337 434 -272 1100 -371 195 378 528 516 227 -27 5 41 -242 -509 -400 65 -755 147 -330 -307 -921 169 81 -43 -773 57 -481 -637 447 128 554 -229 659 -244 278 -320 203 848 -169 278 -132 224 -255 304 6 67 -363 499 105 114 -445 151 253 -79 -103 -416 594 -26 -84 -333 173 -553 136 -410 -103 -40 177 -1 165 194 -201 83 -1 204 -260 344 -242 465 -289 269 -323 258 246 -250 -227 72 173 -239 208 -172 502 -689 87 16 -174 -213 374 -177 73 234 172 92 -314 223 -381 152 -407 -7 114 184 60 -32 -218 -350 196 -99 359 275 290 -577 295 113 474 -805 144 327 -10 -120 -426 131 -527 75 -35 477 -471 -123 -1115 86 -259 174 815 446 -15 382 342 -240 318 -204 826 -280 146 279 380 361 155 -19 3 31 -187 -403 -319 53 -614 117 -263 -247 -774 149 74 -40 -689 47 -380 -506 381 117 529 -222 627 -226 241 -259 154 633 -136 241 -123 219 -256 316 6 76 -423 584 121 127 -467 147 234 -73 -102 -438 661 -31 -99 -382 189 -581 143 -456 -120 -47 217 -1 213 258 -272 109 -2 243 -296 382 -275 549 -360 346 -418 329 306 -302 -266 82 190 -271 246 -209 620 -862 110 21 -236 -295 524 -252 104 325 235 125 -426 310 -557 231 -647 -12 190 311 101 -54