File name: Pandora150s1_Ulsan_20220426_L2Fit_fsus1c10d20210715p1-8.txt File generation date: 20240806T011452.4Z Data description: Level 2 spectral fitting results file Data file version: fsus1c10p1-8 Local principal investigator: Chang Keun Song Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 150 Spectrometer number: 1 Processing software version used: BlickP v1.8.59 Instrument operation file used: Pandora150_OF_v4d20210223.txt Instrument calibration file used: Pandora150s1_CF_v10d20210715.txt Level 1 file used: Pandora150s1_Ulsan_20220426_L1_smca1c10d20210715p1-8.txt Full location name: Ulsan National Institute of Science and Technology, UNIST Short location name: Ulsan Country of location: South Korea Location latitude [deg]: 35.5745 Location longitude [deg]: 129.1896 Location altitude [m]: 38 Local noon date: 20220426 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are dark map for dark correction (replaced by immediate dark method), latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 239 384 Nominal wavelengths inside fitting window [nm]: 306.0528 306.1936 306.3343 306.4751 306.6158 306.7565 306.8972 307.0379 307.1786 307.3192 307.4599 307.6005 307.7411 307.8818 308.0224 308.1630 308.3036 308.4441 308.5847 308.7253 308.8658 309.0063 309.1469 309.2874 309.4279 309.5684 309.7088 309.8493 309.9898 310.1302 310.2706 310.4111 310.5515 310.6919 310.8323 310.9726 311.1130 311.2533 311.3937 311.5340 311.6743 311.8147 311.9550 312.0952 312.2355 312.3758 312.5160 312.6563 312.7965 312.9367 313.0769 313.2171 313.3573 313.4975 313.6377 313.7778 313.9180 314.0581 314.1982 314.3383 314.4784 314.6185 314.7586 314.8986 315.0387 315.1787 315.3187 315.4588 315.5988 315.7388 315.8787 316.0187 316.1587 316.2986 316.4386 316.5785 316.7184 316.8583 316.9982 317.1381 317.2780 317.4178 317.5577 317.6975 317.8373 317.9771 318.1169 318.2567 318.3965 318.5363 318.6760 318.8158 318.9555 319.0952 319.2349 319.3746 319.5143 319.6540 319.7937 319.9333 320.0730 320.2126 320.3522 320.4918 320.6314 320.7710 320.9106 321.0501 321.1897 321.3292 321.4688 321.6083 321.7478 321.8873 322.0267 322.1662 322.3057 322.4451 322.5846 322.7240 322.8634 323.0028 323.1422 323.2816 323.4209 323.5603 323.6996 323.8390 323.9783 324.1176 324.2569 324.3962 324.5354 324.6747 324.8140 324.9532 325.0924 325.2316 325.3709 325.5100 325.6492 325.7884 325.9276 326.0667 326.2058 326.3450 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Temperature at electronics board [°C], 999=no temperature signal Column 155: Spectrometer control temperature [°C], 999=no temperature signal Column 156: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 157: Temperature in head sensor [°C], 999=no temperature signal Column 158: Humidity in head sensor [%], -9=no humidity signal Column 159: Pressure in head sensor [hPa], -9=no pressure signal Columns 160-305: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 306-451: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20220425T235453.8Z 8150.996456 201 1 47.36 2 51.17 102.05 49.70 180.75 0.00 1 0.00 1 0 49 1.433e-02 5.135e-03 1.197e-02 4.773e-03 -7.386050e-06 1.783364e-06 2.390608e-07 3.625887e-07 6.559722e-06 229.93 -2.00 3.40 -2.00 321.85 0.00e+00 2.884867e-03 6.483939e-04 1.568815e-04 1.874673e-05 1.734460e-03 284.80 -2.00 20.00 -2.00 321.87 0.00e+00 3.327530e-03 8.736773e-04 4.582534e-05 2.401893e-05 2.999010e-03 284.80 -2.00 20.00 -2.00 321.68 0.00e+00 1.148912e-03 1.345526e-03 1.210319e-04 1.053826e-05 3.168525e-03 284.80 -2.00 20.00 -2.00 321.74 0.00e+00 2.257246e-01 6.658355e-03 3.544835e-04 1.651424e-03 1.750997e-02 212.91 6.89 0.00 0.20 30.45 318.05 0.00e+00 -1.322415e-03 3.984403e-04 1.082116e-04 6.748755e-06 4.576187e-04 284.80 -2.00 20.00 -2.00 316.92 0.00e+00 1.591 0.000 303.00 329.40 4 6.3839e+00 1.5619e-02 1.5499e-02 1.8241e-03 5.5222e-02 1.9202e-02 2.2945e-02 3.9825e-03 2.4964e-04 5.9272e-02 2.6007e-02 1.2808e-02 1.0641e-03 9.3813e-05 3.2837e-02 -1.7898e-02 5.6418e-03 1.2131e-03 3.7135e-05 1.2591e-02 5.8700e-03 3.8787e-03 4.0682e-04 4.9180e-05 8.2574e-03 1.6287e-04 -1.3244e-02 3.8994e-03 5.3747e-04 1.6665e-05 5.4550e-03 5.2551e-04 1.4506e-04 9.9555e-06 8.2383e-07 4.1995e-04 1.2578e-02 -5.9845e-05 1.8424e+00 4.7675e-01 1.8844e-02 4.7676e-04 1.2103e+00 12 8 8 10 0 0 99.98 18.96 0.26 0.01258 0.01659 17 4 1 5 0 2785.560 21.69 15.02 18.96 27.86 17.1 1016.68 -8855 3417 1006 1093 -2669 -22 3651 1256 2462 -1795 3050 -1075 366 -5473 -886 -2273 1078 225 373 -1482 1465 -193 -360 3387 -2665 3568 1385 2650 3082 2152 1108 578 -2249 1572 -694 -294 761 363 -328 -1463 641 -1482 -438 712 -1199 -905 -68 517 124 -184 -258 -250 -48 766 -394 1619 -573 -1012 453 -355 248 -601 -397 248 -562 987 146 410 590 -859 -331 104 196 -463 -297 436 853 40 -175 28 724 -477 95 -450 -438 -1065 511 -492 -674 313 546 -47 360 338 -104 404 -253 -505 150 96 -213 219 413 -35 410 488 51 -35 -450 -883 -33 -835 -354 871 232 538 -488 -321 -759 76 -197 -89 -521 -223 318 385 -83 -159 -251 163 307 -238 106 332 27 -269 209 266 67 66 274 -171 -71 159 -218 -129 -1128 433 137 148 -383 -3 610 237 497 -388 646 -244 84 -1350 -210 -557 271 60 103 -412 374 -47 -86 815 -725 981 400 719 831 640 382 236 -1078 786 -367 -158 406 192 -174 -770 320 -745 -218 367 -666 -526 -41 319 78 -118 -165 -156 -30 488 -271 1165 -442 -776 317 -235 160 -414 -306 205 -481 832 119 313 412 -557 -205 67 142 -374 -260 399 810 40 -188 32 816 -540 103 -456 -410 -929 431 -442 -663 332 629 -57 426 377 -108 405 -263 -568 175 117 -269 287 566 -49 585 669 66 -42 -516 -1017 -39 -1061 -472 1173 310 699 -615 -385 -877 84 -219 -105 -653 -289 419 512 -115 -231 -381 250 478 -374 163 496 39 -387 309 416 112 117 511 -333 -141 316 -431 -252 SS 20220426T011857.5Z 8151.054832 251 1 20.72 2 35.25 121.08 53.30 205.99 0.00 1 0.00 1 0 49 1.990e-03 1.412e-03 2.197e-03 1.499e-03 -9.818247e-07 5.766208e-07 2.874686e-08 3.624232e-07 9.200016e-07 229.94 -2.00 3.40 -2.00 320.64 0.00e+00 4.903347e-04 1.891551e-04 1.495524e-05 1.850153e-05 2.438869e-04 284.81 -2.00 20.00 -2.00 320.31 0.00e+00 6.183356e-04 2.766043e-04 1.101444e-05 2.397497e-05 4.185680e-04 284.81 -2.00 20.00 -2.00 320.81 0.00e+00 1.014916e-03 3.465433e-04 9.112486e-05 1.037029e-05 4.401654e-04 284.81 -2.00 20.00 -2.00 320.57 0.00e+00 1.619968e-01 1.873440e-03 1.848175e-04 1.650647e-03 2.419221e-03 227.38 2.88 0.00 0.25 4.24 316.00 0.00e+00 1.093921e-04 8.013258e-05 1.934541e-06 6.606457e-06 6.323435e-05 284.81 -2.00 20.00 -2.00 314.97 0.00e+00 1.224 0.000 303.00 329.40 4 4.6508e+00 5.4898e-03 1.1911e-02 1.8245e-03 7.7290e-03 5.4308e-03 6.7788e-03 1.5733e-03 2.4143e-04 8.2335e-03 6.0397e-03 3.7147e-03 3.7027e-04 7.9897e-05 4.6043e-03 -2.4886e-03 1.3417e-03 1.2016e-04 2.1278e-05 1.6733e-03 8.1451e-04 1.0282e-03 5.2630e-05 3.5777e-05 1.1301e-03 1.4526e-03 1.0346e-03 1.1758e-03 7.2002e-05 1.0156e-05 1.0144e-03 3.7358e-04 4.2200e-05 1.3665e-06 7.3854e-07 5.8316e-05 1.0148e-02 -5.7606e-05 -2.2233e-01 1.6070e-01 2.7909e-03 6.3130e-04 1.8952e-01 12 9 1 12 1 1 99.96 19.31 0.23 0.01015 0.01300 16 9 1 5 0 1208.180 21.88 15.02 19.31 30.08 17.3 1020.17 -8 649 -533 -538 -134 189 -11 -538 188 28 87 322 80 -300 -20 -246 54 89 -26 -551 563 76 39 -456 140 346 -206 105 584 199 78 363 -92 207 -8 37 -113 -9 213 57 -281 -126 -34 -316 -164 118 -340 -142 111 66 -117 193 163 86 188 63 77 -13 87 -113 40 -139 -237 39 183 -137 73 -135 -263 33 68 245 7 297 4 -197 -14 -376 107 -135 87 -114 17 37 102 4 -135 -9 -134 -22 -87 -81 34 207 73 70 104 -174 -3 265 -198 118 91 8 34 66 40 -62 179 -64 13 -157 8 64 78 55 -25 232 -177 -47 5 -141 150 -103 -57 -8 194 -28 44 40 -80 -71 -152 26 -177 -79 -100 -107 56 34 154 -55 46 57 -113 134 -2 192 -166 -163 -41 63 -4 -205 77 12 36 138 35 -135 -9 -109 25 43 -13 -274 257 32 16 -192 62 163 -100 48 257 96 44 226 -62 149 -6 28 -86 -7 159 41 -196 -85 -24 -218 -120 90 -270 -115 91 55 -96 156 131 71 157 56 73 -12 73 -93 32 -117 -211 38 173 -129 71 -122 -226 25 53 186 6 264 4 -194 -14 -409 118 -156 103 -134 19 41 101 4 -124 -8 -133 -24 -99 -96 39 238 77 72 112 -194 -4 322 -251 147 119 10 47 85 50 -71 201 -72 16 -190 10 81 97 71 -30 267 -206 -51 5 -165 175 -126 -70 -10 251 -37 60 57 -109 -99 -216 35 -236 -103 -135 -154 82 51 248 -89 76 95 -185 215 SS 20220426T012405.0Z 8151.058391 254 1 48.72 2 34.36 122.62 53.74 207.40 0.00 1 0.00 1 0 49 1.701e-03 1.047e-03 1.874e-03 1.102e-03 -1.123629e-06 4.188850e-07 2.389965e-08 3.624806e-07 7.861432e-07 229.94 -2.00 3.40 -2.00 321.07 0.00e+00 4.799545e-04 1.415362e-04 1.194395e-05 1.858106e-05 2.083378e-04 284.81 -2.00 20.00 -2.00 320.87 0.00e+00 1.682311e-04 2.049398e-04 7.408333e-06 2.397453e-05 3.580097e-04 284.81 -2.00 20.00 -2.00 321.11 0.00e+00 5.421872e-04 2.685449e-04 3.324280e-05 1.041106e-05 3.762628e-04 284.81 -2.00 20.00 -2.00 320.98 0.00e+00 1.618053e-01 1.449611e-03 6.131598e-05 1.651153e-03 2.067176e-03 229.01 2.23 0.00 0.25 3.62 316.70 0.00e+00 1.930091e-05 6.734872e-05 5.142163e-06 6.653729e-06 5.405278e-05 284.81 -2.00 20.00 -2.00 315.60 0.00e+00 1.211 0.000 303.00 329.40 4 4.4873e+00 4.1556e-03 1.1760e-02 1.8239e-03 6.6061e-03 1.0483e-02 5.3310e-03 1.2651e-03 2.4276e-04 7.0353e-03 5.1122e-03 2.8773e-03 1.8293e-04 8.5761e-05 3.9342e-03 -3.1947e-03 1.0389e-03 3.9104e-05 2.4493e-05 1.4285e-03 9.4483e-04 7.9160e-04 3.6302e-05 3.9602e-05 9.6615e-04 1.7475e-03 -1.5250e-03 9.4882e-04 5.5891e-05 1.2207e-05 8.7846e-04 3.4677e-04 3.1705e-05 1.3491e-06 7.7568e-07 4.9852e-05 1.0017e-02 -5.5772e-05 -2.1376e-01 1.2233e-01 2.6975e-03 5.3967e-04 1.6304e-01 11 8 0 10 0 0 99.98 19.34 0.26 0.01002 0.01266 95 22 1 5 0 512.770 21.98 15.03 19.34 30.59 17.3 1023.53 -43 169 -42 396 343 467 -228 273 -212 60 -418 144 -199 -419 68 -67 -258 -341 -362 -264 325 -133 373 -200 -25 52 414 235 648 78 312 164 -11 40 222 107 -14 97 -223 264 -88 -77 -109 78 -275 18 -174 -94 154 4 27 -87 -56 20 -134 127 64 -119 264 -160 -55 94 -126 34 -194 95 -74 -113 45 12 98 172 -107 32 -4 -136 50 -65 48 29 78 76 75 -106 -154 -78 106 -312 -59 -69 119 -88 156 197 49 17 -91 -45 -3 24 36 90 -10 79 -52 167 -112 56 -112 -194 4 5 -23 60 5 -60 50 -104 -3 -7 28 -115 23 -81 81 -2 47 25 49 -23 -22 -30 -35 43 -45 45 -44 115 -134 -18 106 12 27 -17 -95 54 -9 39 -10 93 81 120 -66 86 -72 21 -147 51 -74 -157 25 -25 -100 -139 -152 -109 124 -47 126 -70 -9 20 166 89 238 31 146 91 -7 27 144 71 -9 69 -159 181 -58 -49 -68 51 -191 13 -131 -72 119 3 21 -67 -43 15 -104 106 55 -102 204 -124 -41 74 -104 31 -180 87 -66 -94 36 8 68 123 -86 29 -3 -129 49 -69 54 34 94 92 87 -113 -149 -75 97 -277 -57 -74 139 -108 187 220 51 17 -95 -51 -4 30 46 121 -13 106 -70 214 -143 65 -123 -212 5 6 -30 82 6 -79 63 -123 -4 -8 29 -130 28 -101 103 -3 63 35 66 -32 -31 -43 -49 59 -65 64 -65 164 -207 -29 186 21 48 -30 -166 92 SS 20220426T014543.7Z 8151.073422 269 1 48.40 2 30.81 129.83 55.83 213.17 0.00 1 0.00 1 0 65 4.024e-03 2.463e-03 4.332e-03 2.529e-03 -4.394482e-06 9.642332e-07 7.054240e-08 3.624767e-07 1.865561e-06 229.94 -2.00 3.40 -2.00 321.12 0.00e+00 1.944289e-03 3.294937e-04 4.095316e-05 1.858364e-05 4.939231e-04 284.81 -2.00 20.00 -2.00 320.97 0.00e+00 7.976765e-04 4.674037e-04 5.754069e-06 2.397369e-05 8.472142e-04 284.81 -2.00 20.00 -2.00 321.15 0.00e+00 1.959037e-05 6.264784e-04 5.798616e-05 1.043135e-05 8.902487e-04 284.81 -2.00 20.00 -2.00 321.05 0.00e+00 1.646413e-01 3.258550e-03 2.052463e-04 1.651018e-03 4.883850e-03 219.52 4.81 0.00 0.26 8.57 316.74 0.00e+00 -3.728159e-05 1.566318e-04 1.099024e-05 6.648454e-06 1.278482e-04 284.81 -2.00 20.00 -2.00 315.65 0.00e+00 1.164 0.000 303.00 329.40 4 6.0179e+00 8.6960e-03 1.1305e-02 1.8236e-03 1.5649e-02 1.8110e-02 1.1422e-02 1.4311e-03 2.4186e-04 1.6629e-02 1.8817e-02 6.3704e-03 5.6477e-04 8.4909e-05 9.3079e-03 -9.7035e-03 2.3846e-03 1.5225e-04 2.4649e-05 3.3820e-03 1.0041e-03 1.8184e-03 1.1200e-04 3.9653e-05 2.2871e-03 4.0099e-04 -1.8488e-02 2.1439e-03 2.1402e-04 1.3257e-05 2.1921e-03 3.8835e-04 7.3701e-05 4.1499e-06 7.7506e-07 1.1821e-04 8.5291e-03 -3.1551e-05 7.3296e-01 2.8208e-01 1.0390e-02 5.9626e-04 3.8959e-01 12 8 8 10 0 0 99.99 19.45 0.35 0.00853 0.01149 23 5 1 5 0 2103.960 22.09 15.02 19.45 31.80 17.4 1026.88 990 -413 -695 671 1510 837 -1044 196 -415 -107 772 -40 -607 -795 406 -677 -61 -631 -843 -396 536 -82 1739 -139 471 168 563 -636 522 390 142 679 -370 458 -238 185 -189 284 -385 47 -534 167 150 329 -444 120 -399 -214 186 125 239 26 286 -253 343 -327 37 164 -76 24 31 6 -350 -126 -124 121 35 4 133 228 158 294 11 231 -536 -341 246 42 -47 57 -50 32 134 -244 144 -516 -360 -614 -41 -42 301 169 259 -103 305 211 124 -74 -493 -28 -18 533 249 51 -186 467 -33 -132 55 -230 95 -518 -3 -6 181 56 12 -130 -167 -148 -118 -109 -43 18 -131 -43 69 -67 -317 372 97 145 -68 103 -110 -408 97 -17 171 55 205 23 -33 108 -130 -119 207 -96 -168 157 355 213 -300 61 -138 -36 263 -14 -220 -292 147 -249 -23 -254 -349 -161 204 -29 590 -49 176 66 226 -246 195 159 66 364 -227 298 -160 127 -130 192 -261 31 -342 103 92 208 -297 83 -289 -157 137 94 179 19 210 -193 273 -278 32 143 -61 18 23 4 -297 -115 -116 113 31 3 104 164 109 208 9 197 -498 -332 245 44 -52 65 -60 38 154 -263 143 -472 -319 -568 -41 -45 348 203 305 -116 321 215 131 -83 -585 -35 -23 689 336 71 -259 624 -41 -155 62 -256 110 -637 -4 -8 237 71 15 -153 -191 -162 -129 -124 -52 23 -164 -54 89 -91 -448 531 142 213 -98 145 -153 -559 136 -25 264 90 352 40 -59 197 -234 -211 SS 20220426T022058.4Z 8151.097898 291 1 3.11 2 25.92 144.73 59.98 221.78 0.00 1 0.00 1 0 49 6.653e-03 5.043e-03 6.127e-03 4.829e-03 -7.730459e-07 1.891630e-06 8.635196e-08 3.624169e-07 3.073878e-06 229.94 -2.00 3.40 -2.00 320.13 0.00e+00 8.029352e-04 6.034749e-04 1.253217e-05 1.844087e-05 8.169703e-04 284.81 -2.00 20.00 -2.00 319.71 0.00e+00 -1.559799e-03 8.990098e-04 3.426956e-05 2.395791e-05 1.406797e-03 284.81 -2.00 20.00 -2.00 320.46 0.00e+00 2.687053e-03 1.096024e-03 1.382194e-04 1.026997e-05 1.472313e-03 284.81 -2.00 20.00 -2.00 320.07 0.00e+00 1.378139e-01 5.645260e-03 1.833656e-04 1.650068e-03 8.063241e-03 211.05 9.83 0.00 0.35 14.14 315.12 0.00e+00 1.781899e-04 2.238323e-04 5.617516e-05 6.567151e-06 2.114054e-04 284.81 -2.00 20.00 -2.00 314.21 0.00e+00 1.111 0.000 303.00 329.40 4 4.7633e+00 1.5400e-02 1.0951e-02 1.8250e-03 2.5806e-02 -2.0349e-02 1.8573e-02 2.0333e-03 2.3952e-04 2.7451e-02 2.6218e-02 1.0866e-02 4.3788e-04 7.5651e-05 1.5390e-02 -6.6246e-03 3.9751e-03 8.9336e-05 1.9327e-05 5.5138e-03 -2.7788e-03 3.1350e-03 9.6475e-05 3.0485e-05 3.7982e-03 1.4902e-03 5.5190e-03 3.7155e-03 8.7665e-05 1.0793e-05 3.7227e-03 2.8428e-04 1.3572e-04 2.1858e-06 7.2883e-07 1.9509e-04 8.5544e-03 -7.6121e-05 5.5792e-01 5.2018e-01 1.6179e-03 7.0685e-04 6.5936e-01 12 9 9 12 1 1 999.00 19.61 0.39 0.00855 0.01072 1 8 1 5 0 1469.150 22.19 15.01 19.61 32.07 17.3 1020.79 -1693 -931 -1327 511 2013 1221 -1845 2709 -310 472 -570 763 -1060 316 -255 388 -32 -69 -169 61 1526 400 369 -240 870 -1638 729 -912 7 -266 250 -951 404 392 -716 -670 240 -316 -664 1076 -965 967 -639 -141 -102 512 153 473 -528 -153 377 -724 939 146 260 729 475 -1085 515 -670 331 -871 334 237 178 570 -121 -198 -432 -641 -297 733 -332 -8 -339 -415 528 -109 -190 -121 305 -26 654 -307 494 -544 -312 -508 -87 -673 971 49 131 511 76 183 79 272 418 -185 -690 489 -19 -300 -177 221 25 -54 -343 222 23 -173 -50 -420 -214 -552 470 -505 774 -465 800 -749 414 3 -485 386 852 -149 -339 133 -422 466 -286 434 293 -169 -446 -78 -263 603 -202 286 345 -229 -296 -49 -632 -370 -547 203 791 514 -856 1302 -159 243 -299 403 -575 172 -138 210 -18 -40 -99 36 839 210 189 -125 466 -930 413 -501 4 -152 157 -668 307 311 -584 -553 198 -259 -543 856 -757 735 -485 -109 -81 418 128 401 -452 -132 324 -619 797 126 234 682 456 -1042 464 -576 276 -757 309 230 176 565 -118 -186 -383 -534 -239 598 -291 -8 -333 -422 547 -117 -213 -139 355 -30 740 -334 507 -531 -297 -498 -89 -732 1098 58 151 569 81 191 84 306 484 -220 -842 604 -24 -389 -230 277 30 -61 -378 245 26 -204 -62 -525 -265 -675 559 -584 865 -508 865 -845 480 3 -582 464 1042 -189 -441 176 -563 624 -380 566 377 -216 -580 -104 -366 868 -302 436 533 -356 -457 -74 SS 20220426T022520.5Z 8151.100932 294 1 3.69 2 25.42 146.90 60.55 222.78 0.00 1 0.00 1 0 49 4.010e-03 3.325e-03 4.433e-03 3.488e-03 -1.152507e-07 1.366996e-06 4.369525e-08 3.624079e-07 1.853174e-06 229.94 -2.00 3.40 -2.00 320.13 0.00e+00 2.798111e-04 4.334307e-04 1.178770e-05 1.844221e-05 4.913541e-04 284.81 -2.00 20.00 -2.00 319.72 0.00e+00 1.186419e-04 6.481956e-04 1.889244e-05 2.395730e-05 8.472342e-04 284.81 -2.00 20.00 -2.00 320.46 0.00e+00 1.476914e-03 7.846434e-04 7.977200e-05 1.027866e-05 8.872975e-04 284.81 -2.00 20.00 -2.00 320.08 0.00e+00 1.400600e-01 4.134877e-03 1.067857e-04 1.650094e-03 4.861813e-03 217.79 7.20 0.00 0.30 8.53 315.15 0.00e+00 -2.519696e-05 1.618466e-04 2.516132e-05 6.565298e-06 1.273918e-04 284.81 -2.00 20.00 -2.00 314.22 0.00e+00 1.107 0.000 303.00 329.40 4 4.5889e+00 1.1716e-02 1.0798e-02 1.8252e-03 1.5594e-02 -1.0307e-02 1.4098e-02 1.3997e-03 2.3943e-04 1.6559e-02 1.4719e-02 8.0379e-03 2.8996e-04 7.5686e-05 9.2729e-03 -8.7542e-03 2.9060e-03 5.1406e-05 1.9320e-05 3.3315e-03 4.1716e-03 2.2638e-03 5.8100e-05 3.0539e-05 2.2859e-03 1.8062e-03 -3.9993e-04 2.6498e-03 4.9609e-05 1.1039e-05 2.2657e-03 1.4536e-04 9.7306e-05 1.1443e-06 7.2991e-07 1.1753e-04 8.0664e-03 -1.2918e-04 -6.0383e-02 3.7636e-01 2.6565e-03 7.2890e-04 3.9683e-01 12 9 9 12 1 1 999.00 19.61 0.30 0.00807 0.00918 2 10 1 5 0 1171.200 22.19 15.03 19.61 32.23 17.4 1021.61 -694 -640 -800 491 174 1289 901 -298 -681 728 75 -845 -145 -160 547 -105 194 223 -70 -630 -369 487 -445 463 365 -233 512 -511 20 -443 492 68 -395 28 -237 924 514 584 -177 226 242 63 -249 -240 258 -73 -971 -325 -298 126 -534 12 59 -62 124 -280 -173 -48 -159 -619 498 282 480 84 474 -201 108 -498 729 -377 231 1016 207 -212 -255 253 195 -242 -566 195 -294 -140 -30 63 -238 188 -161 -106 -396 307 142 -326 -78 340 80 104 -45 -223 -249 42 682 -13 -223 418 -74 172 396 193 -160 239 -607 -164 97 747 32 81 -519 285 13 -721 -262 -133 112 -261 155 -380 265 82 -247 113 -377 155 1 82 122 -79 -161 250 -249 219 40 -19 153 186 -198 -61 -255 -252 -327 195 69 539 409 -145 -349 372 39 -448 -79 -87 293 -57 109 128 -41 -368 -205 254 -228 241 197 -132 293 -280 11 -253 308 47 -300 22 -192 755 422 474 -143 180 188 48 -187 -185 206 -59 -818 -278 -255 108 -461 10 50 -54 112 -265 -168 -46 -145 -533 415 245 445 81 471 -200 105 -469 641 -313 185 826 181 -198 -250 257 203 -260 -634 224 -344 -162 -34 69 -244 182 -153 -104 -407 331 161 -382 -90 378 85 108 -48 -253 -291 50 822 -16 -283 540 -96 217 474 220 -176 263 -691 -193 118 929 40 99 -622 327 15 -788 -286 -149 130 -312 185 -457 325 104 -322 149 -506 207 1 107 158 -101 -209 333 -349 317 60 -29 236 289 -305 -93