File name: Pandora162s1_Utsteinen_20260525_L2Fit_fout2c24d20260115p1-8.txt File generation date: 20260608T141905.0Z Data description: Level 2 spectral fitting results file Data file version: fout2c24p1-8 Local principal investigator: Michel Van Roozendael Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 162 Spectrometer number: 1 Processing software version used: BlickP v1.8.88 Instrument operation file used: Pandora162_OF_v10d20191031.txt Instrument calibration file used: Pandora162s1_CF_v24d20260115.txt Level 1 file used: Pandora162s1_Utsteinen_20260525_L1_smca1c24d20260115p1-8.txt Full location name: Princess Elisabeth Antarctic Station Short location name: Utsteinen Country of location: Antarctica Location latitude [deg]: -71.9503 Location longitude [deg]: 23.3469 Location altitude [m]: 1397 Local noon date: 20260525 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 226 368 Nominal wavelengths inside fitting window [nm]: 305.0989 305.2396 305.3803 305.5209 305.6616 305.8022 305.9429 306.0835 306.2241 306.3647 306.5053 306.6458 306.7864 306.9270 307.0675 307.2080 307.3486 307.4891 307.6296 307.7700 307.9105 308.0510 308.1914 308.3319 308.4723 308.6127 308.7531 308.8935 309.0339 309.1743 309.3146 309.4550 309.5953 309.7357 309.8760 310.0163 310.1566 310.2969 310.4371 310.5774 310.7176 310.8579 310.9981 311.1383 311.2785 311.4187 311.5589 311.6991 311.8392 311.9794 312.1195 312.2596 312.3998 312.5399 312.6800 312.8200 312.9601 313.1002 313.2402 313.3802 313.5203 313.6603 313.8003 313.9403 314.0802 314.2202 314.3602 314.5001 314.6400 314.7800 314.9199 315.0598 315.1997 315.3395 315.4794 315.6192 315.7591 315.8989 316.0387 316.1785 316.3183 316.4581 316.5979 316.7377 316.8774 317.0172 317.1569 317.2966 317.4363 317.5760 317.7157 317.8553 317.9950 318.1347 318.2743 318.4139 318.5535 318.6931 318.8327 318.9723 319.1119 319.2514 319.3910 319.5305 319.6700 319.8095 319.9490 320.0885 320.2280 320.3675 320.5069 320.6464 320.7858 320.9252 321.0646 321.2040 321.3434 321.4828 321.6221 321.7615 321.9008 322.0401 322.1794 322.3188 322.4580 322.5973 322.7366 322.8759 323.0151 323.1543 323.2936 323.4328 323.5720 323.7112 323.8503 323.9895 324.1286 324.2678 324.4069 324.5460 324.6851 324.8242 324.9633 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Ozone effective temperature [K] Column 28: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Sulfur dioxide effective temperature [K] Column 39: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 45: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 46: Lower limit used for wavelength scaling [nm] Column 47: Upper limit used for wavelength scaling [nm] Column 48: Order of smoothing polynomial Column 49: Smoothing polynomial coefficient, order 0 Column 50: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 51: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 52: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 53: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 54: Smoothing polynomial coefficient, order 1 Column 55: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 56: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 57: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 58: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 59: Smoothing polynomial coefficient, order 2 Column 60: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 61: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 62: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 63: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 64: Smoothing polynomial coefficient, order 3 Column 65: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 66: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 67: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 68: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 69: Mean value of measured data inside fitting window [same units as measurements] Column 70: Wavelength change polynomial coefficient, order 0 Column 71: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 72: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 76: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 77: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 78: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 80: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 81: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 83: Atmospheric variability [%], 999=no atmospheric variability was determined Column 84: Wavelength effective temperature [°C], 999=no effective temperature given Column 85: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 86: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 87: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 88: Number of bright count cycles Column 89: Number of dark count cycles Column 90: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 91: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 92: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 93: Integration time [ms] Column 94: Spectrometer control temperature [°C], 999=no temperature signal Column 95: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 96: Temperature in head sensor [°C], 999=no temperature signal Column 97: Azimuth motor temperature [°C], 999=no temperature signal Column 98: Zenith motor temperature [°C], 999=no temperature signal Column 99: Temperature at electronics board 1 [°C], 999=no temperature signal Column 100: Temperature at electronics board 2 [°C], 999=no temperature signal Column 101: Humidity in head sensor [%], -9=no humidity signal Column 102: Pressure in head sensor [hPa], -9=no pressure signal Columns 103-245: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 246-388: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given ---------------------------------------------------------------------------------------