File name: Pandora270s1_Warsaw-UW_20250113_L2Fit_fsus1c6d20231207p1-8.txt File generation date: 20250728T123241.2Z Data description: Level 2 spectral fitting results file Data file version: fsus1c6p1-8 Local principal investigator: Iwona Stachlewska Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 270 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora270_OF_v3d20230517.txt Instrument calibration file used: Pandora270s1_CF_v6d20231207.txt Level 1 file used: Pandora270s1_Warsaw-UW_20250113_L1_smca1c6d20231207p1-8.txt Full location name: Warsaw Observatory Station, Faculty of Physics, University of Warsaw Short location name: Warsaw-UW Country of location: Poland Location latitude [deg]: 52.2113 Location longitude [deg]: 20.9828 Location altitude [m]: 137 Local noon date: 20250113 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: None First and last pixel inside fitting window: 205 351 Nominal wavelengths inside fitting window [nm]: 306.0087 306.1492 306.2897 306.4301 306.5705 306.7110 306.8514 306.9918 307.1322 307.2726 307.4129 307.5533 307.6936 307.8339 307.9743 308.1146 308.2549 308.3951 308.5354 308.6757 308.8159 308.9561 309.0964 309.2366 309.3768 309.5169 309.6571 309.7973 309.9374 310.0776 310.2177 310.3578 310.4979 310.6380 310.7781 310.9181 311.0582 311.1982 311.3382 311.4782 311.6182 311.7582 311.8982 312.0382 312.1781 312.3181 312.4580 312.5979 312.7378 312.8777 313.0176 313.1575 313.2973 313.4372 313.5770 313.7168 313.8567 313.9965 314.1362 314.2760 314.4158 314.5555 314.6953 314.8350 314.9747 315.1144 315.2541 315.3938 315.5334 315.6731 315.8127 315.9524 316.0920 316.2316 316.3712 316.5108 316.6503 316.7899 316.9294 317.0690 317.2085 317.3480 317.4875 317.6270 317.7665 317.9059 318.0454 318.1848 318.3242 318.4636 318.6030 318.7424 318.8818 319.0212 319.1605 319.2999 319.4392 319.5785 319.7178 319.8571 319.9964 320.1357 320.2749 320.4142 320.5534 320.6926 320.8318 320.9710 321.1102 321.2494 321.3885 321.5277 321.6668 321.8059 321.9451 322.0842 322.2232 322.3623 322.5014 322.6404 322.7795 322.9185 323.0575 323.1965 323.3355 323.4745 323.6135 323.7524 323.8914 324.0303 324.1692 324.3081 324.4470 324.5859 324.7248 324.8636 325.0025 325.1413 325.2801 325.4190 325.5578 325.6965 325.8353 325.9741 326.1128 326.2516 326.3903 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Bromine oxide slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of bromine oxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of bromine oxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Bromine oxide effective temperature [K] Column 28: Independent uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of bromine oxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective bromine oxide fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for bromine oxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Formaldehyde slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of formaldehyde slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of formaldehyde slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Formaldehyde effective temperature [K] Column 39: Independent uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of formaldehyde effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective formaldehyde fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for formaldehyde [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Nitrous acid slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of nitrous acid slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of nitrous acid slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Nitrous acid effective temperature [K] Column 50: Independent uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of nitrous acid effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective nitrous acid fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for nitrous acid [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 56: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 57: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 58: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 59: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 60: Nitrogen dioxide effective temperature [K] Column 61: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 62: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 63: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 64: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 65: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 66: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 67: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 68: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 69: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 70: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 71: Ozone effective temperature [K] Column 72: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 73: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 74: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 75: rms-based uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 76: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 77: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 78: Sulfur dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 79: Independent uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 80: Structured uncertainty of sulfur dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 81: Common uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 82: rms-based uncertainty of sulfur dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 83: Sulfur dioxide effective temperature [K] Column 84: Independent uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 85: Structured uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 86: Common uncertainty of sulfur dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 87: Effective sulfur dioxide fitting wavelength [nm], -9=fitting not successful Column 88: Diffuse correction applied before fitting at effective fitting wavelength for sulfur dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 89: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 90: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 91: Lower limit used for wavelength scaling [nm] Column 92: Upper limit used for wavelength scaling [nm] Column 93: Order of smoothing polynomial Column 94: Smoothing polynomial coefficient, order 0 Column 95: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 96: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 97: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 98: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 99: Smoothing polynomial coefficient, order 1 Column 100: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 101: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 102: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 103: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 104: Smoothing polynomial coefficient, order 2 Column 105: Independent uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 106: Structured uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 107: Common uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 108: rms-based uncertainty of smoothing polynomial coefficient, order 2, -9=fitting not successful Column 109: Smoothing polynomial coefficient, order 3 Column 110: Independent uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 111: Structured uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 112: Common uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 113: rms-based uncertainty of smoothing polynomial coefficient, order 3, -9=fitting not successful Column 114: Smoothing polynomial coefficient, order 4 Column 115: Independent uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 116: Structured uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 117: Common uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 118: rms-based uncertainty of smoothing polynomial coefficient, order 4, -9=fitting not successful Column 119: Mean value of measured data inside fitting window [same units as measurements] Column 120: Offset polynomial coefficient, order 0 Column 121: Independent uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 122: Structured uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 123: Common uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 124: rms-based uncertainty of offset polynomial coefficient, order 0, -9=fitting not successful Column 125: Wavelength change polynomial coefficient, order 0 Column 126: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 127: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 128: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 129: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 130: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 131: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 132: Resolution change polynomial coefficient, order 0 Column 133: Independent uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 134: Structured uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 135: Common uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 136: rms-based uncertainty of resolution change polynomial coefficient, order 0, -9=fitting not successful Column 137: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 138: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 139: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 140: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 141: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 142: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 143: Atmospheric variability [%], 999=no atmospheric variability was determined Column 144: Wavelength effective temperature [°C], 999=no effective temperature given Column 145: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 146: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 147: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 148: Number of bright count cycles Column 149: Number of dark count cycles Column 150: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 151: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 152: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 153: Integration time [ms] Column 154: Spectrometer control temperature [°C], 999=no temperature signal Column 155: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 156: Temperature in head sensor [°C], 999=no temperature signal Column 157: Temperature at electronics board 1 [°C], 999=no temperature signal Column 158: Temperature at electronics board 2 [°C], 999=no temperature signal Column 159: Humidity in head sensor [%], -9=no humidity signal Column 160: Pressure in head sensor [hPa], -9=no pressure signal Columns 161-307: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 308-454: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SS 20250113T095712.9Z 9144.414733 372 1 54.09 2 74.34 168.49 101.43 354.91 0.00 1 0.00 1 0 177 9.875e-02 3.517e-02 9.219e-02 6.460e-03 -1.544069e-05 2.339548e-06 7.083190e-07 4.234686e-07 4.130023e-05 221.48 -2.00 3.84 -2.00 323.01 0.00e+00 6.138850e-03 9.909449e-04 3.980789e-04 5.353662e-05 1.147362e-02 266.02 -2.00 20.00 -2.00 323.49 0.00e+00 8.527858e-03 1.346631e-03 3.836863e-04 2.888881e-05 2.091798e-02 266.02 -2.00 20.00 -2.00 322.60 0.00e+00 4.043720e-02 2.423846e-03 1.343873e-03 1.876836e-05 2.119051e-02 266.02 -2.00 20.00 -2.00 322.87 0.00e+00 3.148788e-01 9.055787e-03 4.529954e-03 1.033894e-03 1.292679e-01 101.77 5.97 0.00 0.11 212.99 320.00 0.00e+00 -3.198223e-03 8.462216e-04 1.959088e-03 5.207708e-06 3.045974e-03 266.02 -2.00 20.00 -2.00 319.31 0.00e+00 3.641 0.001 303.00 329.40 4 5.4884e+00 3.0478e-02 3.8665e-02 2.1879e-03 3.8871e-01 8.4383e-02 2.3203e-02 3.5083e-02 3.0623e-04 4.2173e-01 -3.4656e-01 1.5481e-02 1.5267e-02 1.4026e-04 2.3162e-01 2.6760e-01 7.7242e-03 3.3748e-03 5.7138e-05 7.7482e-02 -6.5937e-02 6.0868e-03 1.0484e-03 6.4081e-05 5.4976e-02 2.6742e-05 3.5408e-01 1.4148e-02 1.3031e-08 6.5422e-11 1.0490e-07 -1.9743e-03 2.5091e-04 4.0244e-05 1.4098e-06 3.2347e-03 -4.4541e-04 0.0000e+00 7.8733e+00 4.6313e-01 4.5583e-02 1.0449e-03 5.3001e+00 12 9 8 11 40 0 99.98 25.48 -2.58 -0.00045 -0.01551 25 3 1 8 0 2163.500 20.00 25.48 7.71 34.50 33.50 3.3 883.81 -10839 -26776 -18039 7937 -3409 33300 -13501 20 37270 13041 13729 12823 8270 12057 13858 -7234 8728 26037 23862 -187 -9168 -5748 -26737 3291 -25372 1847 -13574 -9549 -10482 -15546 -17371 371 8296 14333 24678 8705 14610 14421 5883 -1657 12730 7953 -14418 4532 1935 19518 9829 3817 2228 8298 317 -4272 8299 -6150 -5064 6455 3523 2948 1460 87 2541 -5554 -7330 -6430 65 -3613 -6912 8759 -1126 -1597 -5348 -4267 -15108 5589 -2268 5729 2996 10803 -1018 4418 -369 49 3388 -4266 -8537 -2487 -7123 -5586 -9671 -1188 8182 5415 3889 -3534 3775 3990 -3991 -5913 -2542 -2663 253 6118 -1486 2757 1523 6855 3933 -2054 -1597 -1433 -5461 158 371 -508 2771 2703 4248 -770 -3371 -4832 2738 3643 -1684 2202 -874 -2347 -2887 -2271 649 -854 3125 -165 -1414 -1720 -1687 1610 2931 173 -1056 -97 0 -131 650 1425 -2247 1521 -176 -609 -3129 -1948 349 -249 204 -1946 3 2190 1924 1984 1806 1210 1461 1476 -1289 1111 2072 2147 -31 -1639 -774 -5140 276 -4769 201 -2493 -1631 -1758 -3141 -4254 80 1976 3641 5560 2633 3864 3611 1653 -519 2993 1982 -5199 1221 589 4779 3111 1418 874 2982 127 -1760 2728 -2586 -2263 2719 1715 1521 755 43 1163 -2856 -4209 -4078 40 -2356 -4557 4381 -588 -752 -2465 -1962 -9166 3052 -1602 4054 2322 7982 -846 3587 -321 42 2698 -3483 -6718 -1856 -5495 -4456 -8331 -1067 7555 5729 4294 -4052 3660 3555 -3734 -5749 -2498 -2792 277 6752 -1928 3684 2195 9473 5457 -2866 -2070 -1785 -7149 200 487 -700 3722 3574 5277 -949 -4053 -5771 2992 4115 -2192 2988 -1323 -3779 -4418 -3599 1051 -1468 5268 -290 -2463 -2877 -2721 2661 4719 295 -1794 -180 0 -291 1406 3175 -5293 3425 -402 SS 20250113T105144.8Z 9144.452602 397 1 54.45 2 73.62 181.67 101.39 6.76 0.00 1 0.00 1 0 49 6.562e-02 4.988e-03 1.100e-02 1.200e-03 -3.696715e-07 4.326555e-07 6.907565e-08 4.234028e-07 2.804035e-05 221.48 -2.00 3.84 -2.00 322.58 0.00e+00 -8.941881e-05 1.704055e-04 5.680332e-05 5.366534e-05 7.614843e-03 266.02 -2.00 20.00 -2.00 322.80 0.00e+00 2.190239e-04 2.240891e-04 1.102654e-05 2.894454e-05 1.413068e-02 266.02 -2.00 20.00 -2.00 322.26 0.00e+00 1.209529e-03 4.075684e-04 1.724293e-04 1.843789e-05 1.407961e-02 266.02 -2.00 20.00 -2.00 322.45 0.00e+00 4.701910e-01 2.068249e-03 5.932566e-04 1.033397e-03 8.619118e-02 213.76 0.98 0.00 0.08 143.19 319.81 0.00e+00 2.290160e-05 1.636756e-04 1.458077e-04 5.277761e-06 2.028529e-03 266.02 -2.00 20.00 -2.00 319.04 0.00e+00 3.490 0.001 303.00 329.40 4 3.6947e+00 4.1841e-03 3.3108e-02 2.1895e-03 2.6007e-01 -9.5676e-03 7.1923e-03 4.6346e-03 2.7965e-04 2.8149e-01 -1.3143e-02 4.0036e-03 1.8486e-03 1.5225e-04 1.5370e-01 1.6777e-02 2.7906e-03 1.0639e-03 1.3706e-04 5.5725e-02 -5.7428e-03 1.5352e-03 2.2831e-04 9.4539e-05 4.1674e-02 3.5548e-04 -1.0527e-03 3.5168e-04 6.1794e-05 1.2136e-05 1.4159e-03 -3.7354e-04 3.8782e-05 6.6347e-06 1.2939e-06 2.1475e-03 2.7738e-04 0.0000e+00 -2.2095e-01 7.8864e-02 4.1408e-03 6.7702e-04 3.6161e+00 12 9 8 11 8 0 99.91 25.50 0.34 0.00028 -0.00257 81 8 1 8 0 672.180 20.00 25.50 8.15 34.50 33.50 3.3 884.65 16522 -14098 -35099 25864 -1642 39408 -19619 -14310 11005 19514 -5447 1646 -4335 3497 4032 10048 2179 9046 7022 -3428 -6461 1603 -8899 5723 -6606 4688 -2909 -1252 -1086 -2962 -5097 -1731 775 482 1694 -1294 1301 926 424 779 2042 493 -3800 1778 -86 2546 987 -755 -642 941 -181 1463 708 -2158 1119 -275 -899 1284 213 -12 461 -471 -933 627 -28 -580 -1035 805 2 254 -756 436 -1493 783 -447 91 88 800 -535 -300 -297 -17 321 -155 -527 462 -7 -764 -529 -100 633 310 103 -552 35 173 631 -456 -211 157 -102 207 -255 199 81 607 114 -181 -57 69 -317 169 196 269 152 -3 215 28 -323 -512 180 264 -29 267 -7 -274 -332 -362 98 -172 376 15 -111 -100 -155 -82 153 5 -117 -75 24 120 154 48 -206 77 61 327 -414 -1377 603 -53 995 -1042 -863 606 1101 -422 126 -369 283 328 791 199 833 700 -389 -741 163 -1006 610 -901 646 -428 -183 -155 -455 -914 -358 187 134 461 -380 382 275 127 235 613 153 -1270 598 -32 1008 394 -326 -288 428 -84 656 314 -994 530 -146 -492 733 122 -6 252 -272 -601 414 -20 -419 -728 519 1 147 -422 250 -987 546 -337 75 74 702 -506 -282 -289 -17 306 -148 -468 405 -6 -650 -500 -101 679 350 120 -626 38 183 641 -490 -229 180 -117 252 -322 273 113 851 156 -245 -72 89 -397 221 271 365 204 -4 283 35 -411 -628 215 335 -39 372 -10 -409 -516 -568 156 -284 630 26 -186 -168 -247 -130 243 9 -196 -132 44 232 306 101 -425 158 127 SS 20250113T111032.6Z 9144.465655 408 1 54.32 2 73.81 186.23 101.00 10.83 0.00 1 0.00 1 0 33 3.113e-02 2.471e-03 5.747e-03 7.398e-04 8.417463e-07 2.671594e-07 6.374638e-08 4.233909e-07 1.362419e-05 221.48 -2.00 3.84 -2.00 322.49 0.00e+00 1.035156e-04 1.040993e-04 3.101152e-05 5.367200e-05 3.615855e-03 266.02 -2.00 20.00 -2.00 322.69 0.00e+00 4.090030e-04 1.372478e-04 1.061358e-05 2.894676e-05 6.815778e-03 266.02 -2.00 20.00 -2.00 322.19 0.00e+00 6.853002e-04 2.440020e-04 1.165546e-04 1.839811e-05 6.680226e-03 266.02 -2.00 20.00 -2.00 322.36 0.00e+00 4.781816e-01 1.264765e-03 3.064272e-04 1.033441e-03 4.097988e-02 216.66 0.59 0.00 0.08 69.13 319.62 0.00e+00 4.123295e-05 9.516896e-05 3.394633e-05 5.280000e-06 9.659586e-04 266.02 -2.00 20.00 -2.00 318.85 0.00e+00 3.529 0.001 303.00 329.40 4 2.7481e+00 2.6507e-03 3.3462e-02 2.1894e-03 1.2428e-01 4.5959e-04 4.4417e-03 3.8766e-03 2.8348e-04 1.3406e-01 -1.5572e-02 2.4397e-03 5.0196e-04 1.5291e-04 7.2953e-02 1.0511e-02 1.6472e-03 5.2181e-04 1.3120e-04 2.7964e-02 -2.6528e-03 9.2269e-04 1.4161e-04 9.2015e-05 2.1487e-02 8.7733e-04 -1.9853e-03 1.8514e-04 4.6220e-05 1.1087e-05 9.2480e-04 -2.6117e-04 2.3607e-05 3.2841e-06 1.3070e-06 1.0199e-03 7.7580e-04 0.0000e+00 -1.5306e-01 4.8028e-02 1.8817e-03 6.5593e-04 1.6973e+00 12 8 8 10 0 0 99.96 25.51 0.32 0.00078 -0.00122 249 26 4 8 0 218.110 20.00 25.51 8.29 34.50 33.50 3.3 886.69 7650 526 -20628 16746 -4261 11281 -7208 -8831 3085 7106 -5137 1252 1672 1999 2667 5144 -892 4841 3402 -1591 -3593 1208 -2938 1443 -3244 2757 -1423 -27 -1711 -1975 -2630 -615 120 -181 1109 -974 613 801 -193 92 678 356 -1626 552 -143 1169 144 -281 -190 185 -268 798 78 -989 453 -142 -357 403 -47 142 252 64 -132 225 193 -68 -371 305 -211 127 88 131 -501 514 -225 55 -73 131 -400 -219 -63 84 293 -222 -219 176 97 -153 -303 -92 303 97 7 -299 102 -3 390 -156 -79 37 -55 1 -57 44 29 163 93 -40 47 -23 -173 180 15 23 85 11 53 117 -150 -307 139 240 -46 40 -88 -125 -56 -81 21 -58 77 66 -45 8 -117 -12 3 115 -84 8 -36 37 89 28 -76 6 8 192 16 -803 493 -162 426 -385 -570 207 510 -446 109 151 186 249 481 -95 526 361 -182 -413 140 -357 167 -444 401 -235 -5 -280 -344 -527 -144 31 -53 347 -301 191 251 -62 29 219 117 -565 200 -57 500 62 -130 -91 91 -133 386 37 -483 232 -75 -210 234 -27 84 149 38 -86 153 140 -50 -266 203 -136 75 53 77 -335 370 -176 45 -64 121 -375 -216 -60 82 279 -211 -203 152 81 -135 -285 -93 330 111 8 -344 113 -3 399 -169 -86 43 -64 1 -74 59 39 227 126 -53 61 -28 -223 233 21 31 114 15 69 153 -187 -384 171 300 -61 55 -126 -187 -84 -125 34 -95 128 110 -74 13 -188 -19 5 180 -138 14 -67 72 178 58 -154 11 16 SS 20250113T121157.7Z 9144.508306 438 1 53.93 2 76.01 200.85 98.40 23.86 0.00 1 0.00 1 0 113 1.747e-01 1.156e-02 9.367e-02 2.212e-03 -5.023473e-06 8.053630e-07 1.711323e-07 4.234933e-07 7.307334e-05 221.49 -2.00 3.84 -2.00 323.13 0.00e+00 7.321986e-04 3.327249e-04 1.876549e-04 5.353835e-05 2.030231e-02 266.02 -2.00 20.00 -2.00 323.66 0.00e+00 -1.255373e-03 4.368677e-04 1.392343e-04 2.891337e-05 3.700621e-02 266.02 -2.00 20.00 -2.00 322.71 0.00e+00 8.311146e-03 9.102986e-04 1.019564e-03 1.858186e-05 3.748803e-02 266.02 -2.00 20.00 -2.00 323.00 0.00e+00 5.056570e-01 4.233010e-03 3.900981e-03 1.032952e-03 2.296666e-01 202.15 1.80 0.00 0.07 376.85 320.80 0.00e+00 -4.604994e-04 4.101698e-04 1.568552e-03 5.859256e-06 5.389429e-03 266.02 -2.00 20.00 -2.00 320.03 0.00e+00 4.046 0.001 303.00 329.40 4 4.1414e+00 7.7384e-03 3.9674e-02 2.1879e-03 6.8932e-01 -8.6364e-02 1.4192e-02 2.7843e-02 2.7410e-04 7.4758e-01 -1.0032e-01 8.9377e-03 1.2905e-02 1.3364e-04 4.1076e-01 1.8393e-01 6.8305e-03 3.4469e-03 9.1053e-05 1.3745e-01 -8.2107e-02 3.2679e-03 4.4660e-04 8.2061e-05 9.7257e-02 1.2676e-04 1.6866e-02 1.2964e-03 9.5829e-09 2.3865e-10 1.8547e-07 -2.3876e-04 7.6083e-05 3.6149e-05 1.2949e-06 5.7182e-03 6.5513e-04 0.0000e+00 2.7624e-02 1.3796e-01 3.3287e-02 1.0102e-03 8.7635e+00 12 8 8 10 0 0 99.98 25.51 0.32 0.00066 -0.00117 59 6 3 8 0 914.030 20.00 25.51 7.85 34.50 33.50 3.3 883.57 -2556 -50033 -75686 37554 -38045 118062 -42645 -32997 13873 67999 -11363 5634 7213 10276 15703 30721 2166 39900 24516 -4327 -20625 2872 -24346 29602 -17338 19417 -6836 -957 -6326 -11034 -12641 -851 7863 6719 10152 509 4946 8376 2096 3306 7074 4710 -8552 5760 2257 9775 3635 -827 -744 1760 -964 4682 3326 -4961 5090 -166 -831 5271 -420 -1367 1817 -1226 -2172 1154 -984 -2774 -4141 2034 -1731 -427 -1541 -126 -4633 1410 -1240 585 -234 2151 -1347 -630 -736 -860 1497 -1312 -2106 741 -803 -2596 -2262 -644 1667 530 281 -1273 120 680 2561 -1481 342 918 -319 808 -813 1006 196 1857 685 -134 -98 367 -886 554 601 658 700 -99 926 192 -684 -1315 408 968 -373 728 -325 -778 -746 -680 98 -288 324 -185 -397 -313 -433 -279 277 40 -173 -133 -244 -117 535 -44 -321 378 388 -31 -1437 -3299 307 -1156 247 -2020 -1701 480 1268 -643 274 354 489 691 1140 122 1547 1213 -304 -1673 167 -1924 1377 -1592 1347 -696 -91 -622 -1205 -1611 -115 1163 1156 1821 106 998 1627 436 683 1417 987 -1941 1323 535 2339 1000 -254 -238 564 -320 1436 1011 -1656 1634 -63 -352 2247 -190 -604 777 -567 -1034 593 -551 -1600 -2339 1004 -879 -196 -694 -59 -2375 793 -822 424 -169 1606 -1108 -541 -653 -771 1279 -1087 -1633 527 -571 -1993 -1949 -580 1669 595 305 -1455 125 643 2453 -1434 348 978 -365 915 -1022 1278 268 2555 932 -174 -128 463 -1153 745 797 892 934 -129 1227 246 -846 -1575 475 1198 -488 1036 -473 -1196 -1197 -1154 166 -505 575 -334 -705 -530 -738 -454 448 69 -305 -245 -490 -244 1186 -99 -739 868 898 SS 20250113T144231.9Z 9144.612869 538 1 48.01 2 89.85 233.29 84.88 53.13 0.00 1 0.00 1 7 260 3.409e-01 1.467e-01 7.615e-02 5.022e-02 6.577625e-05 1.880429e-05 1.978132e-06 4.230304e-07 1.442145e-04 221.49 -2.00 3.84 -2.00 317.94 0.00e+00 -1.108093e-02 5.612619e-03 1.850658e-03 5.411899e-05 3.962635e-02 266.01 -2.00 20.00 -2.00 316.76 0.00e+00 7.801855e-02 1.021307e-02 5.223752e-04 2.887172e-05 7.336588e-02 266.01 -2.00 20.00 -2.00 318.91 0.00e+00 5.350525e-02 1.009612e-02 3.674044e-03 1.815859e-05 7.315517e-02 266.01 -2.00 20.00 -2.00 317.82 0.00e+00 8.250170e-02 6.526033e-02 6.820760e-03 1.032234e-03 4.627948e-01 -1046.66 1774.90 0.00 25.82 12520.53 314.68 0.00e+00 -2.639420e-04 1.584718e-03 6.336771e-05 5.847187e-06 1.049307e-02 266.01 -2.00 20.00 -2.00 311.96 0.00e+00 20.664 0.196 303.00 329.40 4 -8.8632e+00 1.9687e-01 2.7399e-01 2.1889e-03 1.3794e+00 1.5189e+00 2.1231e-01 4.3968e-02 3.1857e-04 1.4817e+00 -4.0312e-01 1.1713e-01 2.2213e-02 1.2941e-04 8.1341e-01 2.0527e-01 3.9176e-02 5.5368e-03 3.5300e-05 2.7396e-01 2.2472e-01 2.8401e-02 6.5574e-03 2.6218e-05 1.9624e-01 2.7602e-07 2.5891e+01 1.8991e-01 1.7494e-03 2.0815e-05 5.7123e-01 -5.0578e-03 1.5987e-03 3.4855e-05 1.6167e-06 1.1230e-02 -9.6873e-02 0.0000e+00 5.1005e+00 6.3281e-01 1.4223e-02 3.7229e-04 4.2352e+00 12 10 8 10 0 0 42.87 25.50 -51.96 -0.09687 -0.13546 12 1 2 8 0 4000.000 20.00 25.50 5.68 34.50 33.50 3.4 876.09 900000 -23753 -17287 -7495 1566 -315061 -3517 10585 20319 -71490 23269 18116 14363 13346 10868 5623 13390 5566 4837 8964 5057 8098 -7451 -10108 -17785 -19600 -17963 -11143 -14680 -21402 -24309 -4544 4756 9887 19772 13864 18031 19486 17652 18807 16838 9775 -10773 -2010 1130 -114860 9058 8499 5074 7510 174 -13192 -7414 -8580 -44046 6609 8021 -70040 12139 6877 3771 -11123 -15809 -707 5709 3971 -2604 -34458 9153 4926 -4830 -17252 -31724 -25385 1462 4420 14364 -10376 9053 21266 14498 11266 3086 4493 -1099 -9827 -13908 -25471 -22054 -929 -36856 23948 29022 8037 18574 12353 900000 511 6831 8288 13129 -4588 7708 24199 20031 -20342 25465 -1192 2325 -6052 -21838 139 -5069 -25684 16064 23300 21417 11065 -1766 -12814 3032 -35449 -2251 -2132 499 -3883 -4042 -277 2191 1829 6042 8374 -632 -3436 -12069 -3462 -8707 -9845 -12549 -6832 1767 9713 -79 19457 3602 -5434 7676 900000 -20677 -18652 -4128 1291 -41195 -4278 11533 11915 -17562 24064 18375 14398 12374 6287 2807 11512 3308 2817 9377 6191 7412 -10008 -5206 -21211 -11649 -18790 -9404 -13436 -23659 -33133 -4051 4297 10891 13788 16150 17504 14670 16576 16766 12543 7126 -15154 -1251 927 -25941 7752 8927 5529 6622 196 -7071 -4999 -10199 -16373 6399 9327 -20284 13695 8293 3505 -13846 -21457 -477 6342 4737 -3590 -13107 8110 3811 -4196 -12752 -47034 -12509 1719 2484 14528 -4664 11896 17557 17358 12661 1761 5535 -1392 -5820 -14849 -35231 -32029 -984 -13222 19461 28100 13514 16619 9024 900000 676 5492 6018 14471 -2003 12495 21652 24763 -7386 23445 -2030 2934 -8110 -40117 142 -2980 -10546 11457 22257 16201 11144 -2068 -19274 2372 -14097 -2286 -1419 591 -5573 -5556 -310 1553 2214 3865 8615 -801 -3935 -16224 -3670 -6086 -8941 -12172 -7082 2075 11869 -43 17762 5480 -2868 7007