File name: Pandora232s1_Yongin_20230602_L2Fit_fwvt1c3d20221026p1-8.txt File generation date: 20250512T075024.7Z Data description: Level 2 spectral fitting results file Data file version: fwvt1c3p1-8 Local principal investigator: ---- Network principal investigator: Alexander Cede Instrument type: Pandora Instrument number: 232 Spectrometer number: 1 Processing software version used: BlickP v1.8.75 Instrument operation file used: Pandora232_OF_v1d20220714.txt Instrument calibration file used: Pandora232s1_CF_v3d20221026.txt Level 1 file used: Pandora232s1_Yongin_20230602_L1_smca1c3d20221026p1-8.txt Full location name: Hankuk University of Foreign Studies Short location name: Yongin Country of location: South Korea Location latitude [deg]: 37.3380 Location longitude [deg]: 127.2650 Location altitude [m]: 122 Local noon date: 20230602 Notes on s-number (L1 configuration): Corrections NOT applied although requested by the s-number are latency correction, matrix method stray light correction (replaced by simple method) Data caveats: offical since 20250506 First and last pixel inside fitting window: 1619 1768 Nominal wavelengths inside fitting window [nm]: 492.0362 492.1576 492.2789 492.4003 492.5216 492.6429 492.7642 492.8855 493.0067 493.1280 493.2492 493.3704 493.4916 493.6128 493.7339 493.8551 493.9762 494.0973 494.2184 494.3394 494.4605 494.5815 494.7026 494.8236 494.9446 495.0655 495.1865 495.3074 495.4284 495.5493 495.6701 495.7910 495.9119 496.0327 496.1535 496.2743 496.3951 496.5159 496.6366 496.7574 496.8781 496.9988 497.1195 497.2402 497.3608 497.4815 497.6021 497.7227 497.8433 497.9638 498.0844 498.2049 498.3254 498.4459 498.5664 498.6869 498.8073 498.9278 499.0482 499.1686 499.2890 499.4093 499.5297 499.6500 499.7703 499.8906 500.0109 500.1312 500.2514 500.3716 500.4918 500.6120 500.7322 500.8524 500.9725 501.0926 501.2128 501.3329 501.4529 501.5730 501.6930 501.8131 501.9331 502.0531 502.1730 502.2930 502.4129 502.5328 502.6528 502.7726 502.8925 503.0124 503.1322 503.2520 503.3718 503.4916 503.6114 503.7311 503.8509 503.9706 504.0903 504.2100 504.3296 504.4493 504.5689 504.6885 504.8081 504.9277 505.0473 505.1668 505.2864 505.4059 505.5254 505.6448 505.7643 505.8838 506.0032 506.1226 506.2420 506.3614 506.4807 506.6001 506.7194 506.8387 506.9580 507.0773 507.1965 507.3157 507.4350 507.5542 507.6734 507.7925 507.9117 508.0308 508.1499 508.2690 508.3881 508.5072 508.6262 508.7453 508.8643 508.9833 509.1023 509.2212 509.3402 509.4591 509.5780 509.6969 509.8158 509.9346 --------------------------------------------------------------------------------------- Column 1: Two letter code of measurement routine Column 2: UT date and time for center-time of measurement, yyyymmddThhmmssZ (ISO 8601) Column 3: Fractional days since 1-Jan-2000 midnight for center-time of measurement Column 4: Routine count (1 for the first routine of the day, 2 for the second, etc.) Column 5: Repetition count (1 for the first set in the routine, 2 for the second, etc.) Column 6: Total duration of measurement set in seconds Column 7: Data processing type index Column 8: Solar zenith angle for center-time of measurement in degree Column 9: Solar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 10: Lunar zenith angle for center-time of measurement in degree Column 11: Lunar azimuth for center-time of measurement in degree, 0=north, increases clockwise Column 12: Pointing zenith angle in degree, absolute or relative (see next column), 999=tracker not used Column 13: Zenith pointing mode: zenith angle is... 0=absolute, 1=relative to sun, 2=relative to moon Column 14: Pointing azimuth in degree, increases clockwise, absolute (0=north) or relative (see next column), 999=tracker not used Column 15: Azimuth pointing mode: like zenith angle mode but also fixed scattering angles relative to sun (3) or moon (4) Column 16: Fitting result index: 0=no error or warning, 1, 2=warning, >2=error Column 17: Number of function evaluations used, 0=linear fitting or fitting not successful or no fitting done Column 18: rms of unweighted fitting residuals, -9=fitting not successful Column 19: Normalized rms of fitting residuals weighted with independent uncertainty, -9=fitting not successful or no uncertainty used Column 20: Expected rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 21: Expected normalized weighted rms based on independent uncertainty, -9=fitting not successful or no uncertainty given Column 22: Water vapor slant column amount [moles per square meter], -9e99=fitting not successful Column 23: Independent uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 24: Structured uncertainty of water vapor slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 25: Common uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 26: rms-based uncertainty of water vapor slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 27: Water vapor effective temperature [K] Column 28: Independent uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 29: Structured uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 30: Common uncertainty of water vapor effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 31: Effective water vapor fitting wavelength [nm], -9=fitting not successful Column 32: Diffuse correction applied before fitting at effective fitting wavelength for water vapor [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 33: Nitrogen dioxide slant column amount [moles per square meter], -9e99=fitting not successful Column 34: Independent uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 35: Structured uncertainty of nitrogen dioxide slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 36: Common uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 37: rms-based uncertainty of nitrogen dioxide slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 38: Nitrogen dioxide effective temperature [K] Column 39: Independent uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 40: Structured uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 41: Common uncertainty of nitrogen dioxide effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 42: Effective nitrogen dioxide fitting wavelength [nm], -9=fitting not successful Column 43: Diffuse correction applied before fitting at effective fitting wavelength for nitrogen dioxide [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 44: Ozone slant column amount [moles per square meter], -9e99=fitting not successful Column 45: Independent uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 46: Structured uncertainty of ozone slant column amount [moles per square meter], -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 47: Common uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -6=no common uncertainty input was given, -7=not given since method "MEAS" was chosen, -9=spectral fitting not successful Column 48: rms-based uncertainty of ozone slant column amount [moles per square meter], -1=cross section is zero in this wavelength range, -3=spectral fitting was done, but no rms-based uncertainty could be retrieved, -9=spectral fitting not successful Column 49: Ozone effective temperature [K] Column 50: Independent uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no independent uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -5=no independent uncertainty input was given, -9=spectral fitting not successful Column 51: Structured uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -9=spectral fitting not successful Column 52: Common uncertainty of ozone effective temperature [K], -1=temperature fitting was requested, but cross section is zero in this wavelength range, -2=no temperature fitting was requested and output for effective temperature and structured uncertainty of it is based on f-code, -3=spectral fitting was done, but no common uncertainty could be retrieved, -4=temperature fitting was requested, but differential optical depth is too small to retrieve the temperature, -6=no common uncertainty input was given, -9=spectral fitting not successful Column 53: Effective ozone fitting wavelength [nm], -9=fitting not successful Column 54: Diffuse correction applied before fitting at effective fitting wavelength for ozone [%], 0=no diffuse correction applied or fitting not requested, >0=measured diffuse correction, <0=(negative value of) calculated diffuse correction Column 55: Molecular scattering air mass factor used for molecular scattering subtraction before the fitting Column 56: Estimated uncertainty of molecular scattering air mass factor, -9=molecular scattering was not subtracted before the fitting Column 57: Lower limit used for wavelength scaling [nm] Column 58: Upper limit used for wavelength scaling [nm] Column 59: Order of smoothing polynomial Column 60: Smoothing polynomial coefficient, order 0 Column 61: Independent uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 62: Structured uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 63: Common uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 64: rms-based uncertainty of smoothing polynomial coefficient, order 0, -9=fitting not successful Column 65: Smoothing polynomial coefficient, order 1 Column 66: Independent uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 67: Structured uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 68: Common uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 69: rms-based uncertainty of smoothing polynomial coefficient, order 1, -9=fitting not successful Column 70: Mean value of measured data inside fitting window [same units as measurements] Column 71: Wavelength change polynomial coefficient, order 0 Column 72: Independent uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 73: Structured uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 74: Common uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 75: rms-based uncertainty of wavelength change polynomial coefficient, order 0, -9=fitting not successful Column 76: L1 based wavelength change coefficient, order 0, -9=no L1 wavelength change determination Column 77: L1 based wavelength change coefficient, order 1, -9=no L1 wavelength change determination Column 78: L2Fit data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 79: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ1 limit, 0=L1 data quality above 0, 1=Spectral fitting was not successful, 2=Wavelength shift too large, 3=Normalized rms of fitting residuals weighted with independent uncertainty too large Column 80: Sum over 2^i using those i, for which the corresponding L2Fit data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 81: L1 data quality flag: 0=assured high quality, 1=assured medium quality, 2=assured low quality, 10=not-assured high quality, 11=not-assured medium quality, 12=not-assured low quality Column 82: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ1 limit, 0=Saturated data, 1=Too few dark counts measurements, 2=No temperature given or effective temperature too different from the reference temperature, 3=Dark count too high, 4=Unsuccessful dark background fitting, 5=The dark count differs significantly from the dark map for too many pixels, 6=Absolute value of estimated average residual stray light level too high, 7=Although attempted, no wavelength change could be retrieved, 8=Absolute value of retrieved wavelength shift too large, 9=Retrieved wavelength shift differs too much from the shift predicted by the effective temperature Column 83: Sum over 2^i using those i, for which the corresponding L1 data quality parameter exceeds the DQ2 limit (same parameters as for DQ1) Column 84: Atmospheric variability [%], 999=no atmospheric variability was determined Column 85: Wavelength effective temperature [°C], 999=no effective temperature given Column 86: Estimated average residual stray light level [%] (only valid for stray light correction methods 2 and higher) Column 87: Retrieved wavelength shift from L1 data [nm], -9=no wavelength change determination Column 88: Retrieved total wavelength shift [nm], -9=no wavelength change fitting Column 89: Number of bright count cycles Column 90: Number of dark count cycles Column 91: Effective position of filterwheel #1, 0=filterwheel not used, 1-9 are valid positions Column 92: Effective position of filterwheel #2, 0=filterwheel not used, 1-9 are valid positions Column 93: Sum over 2^i, 0=spectra were interpolated in time, 1=spectra are corrected for off-target signal Column 94: Integration time [ms] Column 95: Spectrometer control temperature [°C], 999=no temperature signal Column 96: Auxiliary spectrometer temperature [°C], 999=no temperature signal Column 97: Temperature in head sensor [°C], 999=no temperature signal Column 98: Temperature at electronics board 1 [°C], 999=no temperature signal Column 99: Temperature at electronics board 2 [°C], 999=no temperature signal Column 100: Humidity in head sensor [%], -9=no humidity signal Column 101: Pressure in head sensor [hPa], -9=no pressure signal Columns 102-251: Unweighted slant column residuals for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting Columns 252-401: Normalized slant column residuals weighted with independent instrumental uncertainty for each pixel inside the fitting window multiplied by 1e5, 9e5=pixel was not used for fitting, 0=no independent instrumental uncertainty was given --------------------------------------------------------------------------------------- SO 20230602T054953.3Z 8553.242978 8874 1 19.14 2 33.89 253.44 124.17 87.84 0.00 1 0.00 1 15 0 -9.000e+00 -9.000e+00 -9.000e+00 -9.000e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 286.89 -2.00 20.00 -2.00 -9.00 0.00e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 286.89 -2.00 20.00 -2.00 -9.00 0.00e+00 -9.000000e+99 -9.000000e+00 -9.000000e+00 -9.000000e+00 -9.000000e+00 232.08 -2.00 3.44 -2.00 -9.00 0.00e+00 1.204 0.000 489.00 513.00 1 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -8.5712e-08 0.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 -9.0000e+00 0.0000e+00 0.0000e+00 12 11 10 11 16 0 95.45 24.46 168.51 0.00000 -9.00000 6 6 1 2 0 3189.350 20.00 24.46 32.70 26.73 26.83 6.0 1100.00 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 900000 SO 20230602T085843.8Z 8553.374118 11943 1 19.46 2 71.00 283.85 89.51 114.92 0.00 1 0.00 1 0 38 1.113e+00 4.873e-01 5.425e-01 2.842e-01 -3.933588e+04 1.374828e+04 1.473202e+03 -6.000000e+00 6.308215e+04 286.90 -2.00 20.00 -2.00 504.78 0.00e+00 2.867845e-02 7.750667e-03 1.154930e-03 -6.000000e+00 3.271296e-02 286.90 -2.00 20.00 -2.00 499.85 0.00e+00 6.732621e+00 5.959684e+00 3.002245e-01 -6.000000e+00 2.344241e+01 232.09 -2.00 3.44 -2.00 501.36 0.00e+00 3.035 0.000 489.00 513.00 1 1.3493e+01 4.5206e-01 3.1846e-02 -6.0000e+00 1.7780e+00 6.2161e-02 1.1764e-01 3.6119e-03 -6.0000e+00 4.8832e-01 4.6979e-07 1.1299e-01 1.6414e-02 1.8033e-04 -6.0000e+00 1.0477e-01 3.8237e-03 -1.0620e-03 12 12 8 10 0 0 -56.13 24.44 -261.41 0.00382 0.78754 5 5 2 2 0 3891.190 20.00 24.44 34.99 26.73 26.83 5.7 1100.00 900000 900000 -21283 900000 -30149 43082 -16292 86802 30929 900000 -37880 -23132 15647 171976 76641 -6640 39666 11832 52187 900000 -9081 27012 52047 182454 16603 41816 -52074 55102 72671 162366 84913 291371 13105 -4616 33474 401554 294572 900000 300281 164012 70475 50358 46828 9342 16888 98153 -9009 26245 41537 200235 30825 194244 -17924 54371 106271 54440 -65586 83477 107165 65452 303325 39660 -6816 -5263 174619 44319 -18314 102260 79772 72382 11741 3422 47189 900000 8952 201487 56253 39191 16349 54507 100782 74938 900000 58699 46242 182589 104398 59014 14817 86729 170287 -29888 -335 161021 11642 41230 -27476 2899 17819 6773 218593 69809 25449 -65677 104984 97132 28487 -289 -3278 54909 900000 403137 54542 -45886 -38691 109870 394995 126831 -5333 9923 61337 -33544 43625 900000 45870 29414 124557 103829 84790 50476 89888 -3852 88977 21792 18010 16103 -45305 131430 59479 118829 -12453 47178 84165 118571 900000 900000 66696 -6950 1739 -48509 900000 900000 -39432 900000 -58652 38913 -26036 48248 29369 900000 -70185 -36966 17032 47796 46151 -9073 33991 13428 39886 900000 -13250 27527 40984 50708 17304 32928 -104925 38285 43760 45125 47198 80978 14568 -6094 30235 111600 81868 900000 83455 45582 50599 44319 42298 12116 19948 50011 -13145 26745 36556 55650 32126 53985 -31549 46592 54147 46651 -188353 54133 54603 50024 84300 37660 -10104 -7557 48530 36952 -28418 47367 46188 45262 13325 4121 36066 900000 9952 55998 39085 31769 16282 36609 42014 39918 900000 36706 33200 50745 43522 41003 17158 52225 47326 -65068 -536 48481 14829 37241 -47090 3491 17745 7058 60752 33952 18861 -112327 36472 38243 23751 -349 -3995 41966 900000 112040 39159 -79459 -61210 43258 109778 44061 -6612 10607 39339 -55935 33575 900000 35303 26411 42606 42175 39879 32373 38434 -4282 39946 19101 16171 14458 -73610 36527 34332 38106 -14643 29249 34187 32954 900000 900000 32795 -7280 1673 -75705